Professional Documents
Culture Documents
GEP62SP-3 (Single Phase)
GEP62SP-3 (Single Phase)
GEP62SP-3 (Single Phase)
G E N E R A T O R S E T
GEP62SP-3
(Single Phase)
50 HZ
STANDBY 62 kVA / 62 kW
PRIME 56 kVA / 56 kW
60 HZ
STANDBY 70 kVA / 70 kW
PRIME 64 kVA / 64 kW
FEATURES
GENERATOR SET COOLING SYSTEM
● Complete system designed and built at ISO9001 ● Standard ambient temperatures up to 50° C (122° F)
certified facility ● Fan, fan drive and charging alternator fully guarded
● Factory tested to design specifications at full load ● Antifreeze protection coolant
conditions
● Fully engineered with a range of options CIRCUIT BREAKER
and accessories ● 3-pole miniature circuit breaker (mcb) < 160 amps
and 3-pole molded case circuit breaker (mccb)
ENGINE >= 160 amps
● Industrial water cooled diesel engine ● Vibration isolated sheet steel enclosure with
● Governor, mechanical removable cover plate
● Electrical system, 12 VDC ● Outgoing cable stub-up area directly below circuit
● Cartridge type fuel and oil filters breaker
● Air filter AUTOMATIC VOLTAGE REGULATOR
● Battery(s), rack and cables ● Voltage regulation ±0.5 %
GENERATOR ● Provides fast recovery from transient load changes
● Self excited brushless generator EQUIPMENT FINISH
● Insulation system, class H ● All electroplated hardware
● Drip proof generator air intake (IP23) ● Anticorrosive paint protection
● Electrical design in accordance with BS5000 Part 99, ● High gloss polyurethane paint for durability and
IEC34-1, VDE0530, UTE51100
scuff resistance
CONTROL SYSTEM QUALITY STANDARDS
● 1001 keystart control panel ● BS4999, BS5000, BS5514, IEC34, VDE0530
● Vibration isolated sheet steel enclosure with hinged
lockable door DOCUMENTATION
● Operation and maintenance manuals provided
MOUNTING ARRANGEMENT
● Wiring diagrams included
● Heavy-duty fabricated steel base with lifting points
● Anti-vibration pads to ensure vibration isolation WARRANTY
● Engine coupled to generator with flexible ● 12 months from date of initial start-up or 18 months
disc coupling from shipping, whichever occurs first
● Baseframe incorporates integral plastic fuel tank, 8
hours running capacity
EXHAUST SYSTEM
● Heavy duty industrial capacity exhaust silencer
(approximately 10 dB reduction) supplied loose
W H E R E T H E W O R L D T U R N S F O R P O W E R
5 0 H z S T A N D B Y 6 2 k V A / 6 2 k W
P R I M E 5 6 k V A / 5 6 k W
6 0 H z S T A N D B Y 7 0 k V A / 7 0 k W
P R I M E 6 4 k V A / 6 4 k W
L W
60 Hz
Standby Prime
Voltage
Code Voltage kVA kW kVA kW
V621 240 70 70 64 64
V622 240/120 70 70 64 64
V623 230 70 70 64 64
V624 230/115 70 70 64 64
V625 220 70 70 64 64
V626 220/110 70 70 64 64
Ratings at 27° C (80° F), 152.4 m (500 ft), 60% humidity, 0.8 pf
RATING DEFINITIONS
STANDBY PRIME POWER
These ratings are applicable for supplying These ratings are applicable for supplying
continuous electrical power (at variable load) in continuous power (at variable load) in lieu of
the event of a utility power failure. No overload commercially purchased power. There is no
is permitted on these ratings. When used at limitation to the annual hours of operation and
standby rating the alternator will be peak this model can supply 10% overload power for
continuous rated (as defined in ISO8528-3). 1 hour in 12 hours.
www.CAT-ElectricPower.com