TECHNICAL REPORT
ON

VIBRATION MONITORING
OF SHIPBOARD MACHINERY
ONBOARD
‘CSC DYNAMIC VISION’

for

Chevron Shipping Company LLC


by

DiagnoVeritas Pte Ltd


July 4, 2007

Report No: REP-07-057


Revision 0

ACTION REPORT

file://C:\Users\DiagnoVeritas\Desktop\CSC Dynamic Vision\Dynamic Vision\000 - Cover... 17/3/2008


Spectrum Page 1 of 1

Report No: REP-07-071

Chevron Shipping Company LLC


PO BOX 9032, Section 323
Concord, CA US
94524-1932
Attention: Mr. Shantanu Vinekar
Repair Superintendent

Dear Sir

Subject: Vibration Analysis of Shipboard Machinery - CSC Dynamic Vision

The following report presents the results of the vibration survey for the shipboard machinery onboard CSC Dynamic
Vision at anchorage in Fujairah dated 5th January 2008. The objective of the survey is to assess the service condition of
surveyed equipment and diagnose those found to be unsatisfactory with corrective actions. The survey also enables
clients to satisfy requirements of Special Survey of Machinery in accordance with American Bureau of Shipping (ABS)
Guide for Survey based on Preventive Maintenance Techniques.

The survey was conducted between the 4th to 7th January 2008 and was assisted by the Chief Engineer of CSC Dynamic
Vision. Most equipment were surveyed and four (4) equipment were found to have bearing fault which have persisted
over the years. However, fault signature was found to be stable and equipment is deemed fit for continued service.

The entire report has been expressed and documented without prejudice. The arrival of the executive summary, results &
recommendations herein are solely limited to vibration analysis, and is based on related experiences, empirical
references and expertise during the course of our professional consultancy services.

Reported by: Mr Sarafian Salleh (Vibration Specialist)

file://C:\Users\DiagnoVeritas\Desktop\CSC Dynamic Vision\Dynamic Vision\000 - Introd... 17/3/2008


Spectrum Page 1 of 1

1.0 Introduction
DiagnoVeritas Pte Ltd was commissioned by ChevronTexaco Shipping Company to perform a vibration condition monitoring assessment
onboard CSC Dynamic Vision during anchorage in Fujairah on the 4th to 7th January 2008.

The objective of the survey is to assess the service condition of surveyed equipment and diagnose those found to be unsatisfactory with
corrective actions. The survey also enables clients to satisfy requirements of Special Survey of Machinery in accordance with American
Bureau of Shipping (ABS) Guide for Survey based on Preventive Maintenance Techniques.The survey was assisted by Mr. Mike Frost, Chief
Engineer of CSC Dynamic Vision.

2.0 Instrumentation
The following instrumentation were used to perform the vibration measurement:

• Vibration Analyzer - EntekIRD Datapac 1500


• Vibration Transducer - ICP Accelerometer 100mV/g
• Force Response Hammer - Entek.

3.0 Vibration Criteria

A: Excellent B: Satisfactory C: Improvement Required D: Unsatisfactory


The vibration criteria of the equipment will be compared against the International Standard Organization, ISO 10816 for acceptance. The vibration criteria will be classified in accordance to the power rating of the
equipment as shown in the Class 1 to 4.

file://C:\Users\DiagnoVeritas\Desktop\CSC Dynamic Vision\Dynamic Vision\000 - Introd... 17/3/2008


 
022 Page 1 of 1

Client : ChevronTexaco Shipping Corporation


Vessel : Dynamic Vision
Date :5th January 2008
Equipment (022) : Main Engine Camshaft LO Pump
Remarks : Fujairah
Equipment Status : Marginal (Bearing Condition)

Measurement Overall Vibration in mm/sec


Points Jan-08 Jul-08
A - 1L 0.073
A - 1T 0.035
A - 1V 0.024
B - 2L 0.034
B - 2T 0.045
B - 2V 0.029
C - 3L 0.058
C - 3T 0.044
C - 3V 0.037

Summary of Result : Equipment condition is satisfactory at time of survey. The vibration was
dominated by the operating frequency of the motor. Bearings condition
exhibited intermediate fault at motor and pump end bearings. Fault condition
has indicated signs of deterioration.

Equipment is deemed fit for continued service.


Trend Further. Monitor bearing condition during the next survey.
Recommendation:

file://C:\Users\DiagnoVeritas\Desktop\CSC Dynamic Vision\Dynamic Vision\022 - ME C... 17/3/2008


023 Page 1 of 1

Client : ChevronTexaco Shipping Corporation


Vessel : Dynamic Vision
Date : 5th January 2008
Equipment (023) : Main Engine Camshaft LO Pump - AFT #2
Remarks : Fujairah
Equipment Status : Marginal (Bearing Condition)

Measurement Overall Vibration in mm/sec


Points Jan-08 Jul-08
A - 1L 0.043
A - 1T 0.030
A - 1V 0.020
B - 2L 0.023
B - 2T 0.024
B - 2V 0.028
C - 3L 0.051
C - 3T 0.062
C - 3V 0.021

Summary of Result : Equipment condition is satisfactory at time of survey. The vibration was
dominated by the operating frequency of the motor. Bearings condition were
satisfactory at time of survey with the exception of the pump drive end which
exhibited intermediate fault.

Equipment is deemed fit for continued service.


Trend Further. Monitor pump drive end bearing during the next survey.
Recommendation:

file://C:\Users\DiagnoVeritas\Desktop\CSC Dynamic Vision\Dynamic Vision\023 - ME C... 17/3/2008


030 Page 1 of 1

Client : ChevronTexaco Shipping Corporation


Vessel : Dynamic Vision
Date :5th January 2008
Equipment (030) : #1 Stern-tube LO Pump
Remarks : Fujairah
Equipment Status : Marginal (Bearing Condition)

Measurement Overall Vibration in mm/sec


Points Jan-08 Jul-08
A - 1L 0.089
A - 1T 0.022
A - 1V 0.021
B - 2L 0.033
B - 2T 0.043
B - 2V 0.027
C - 3L 0.028
C - 3T 0.021
C - 3V 0.020

Summary of Result : Equipment condition is satisfactory at time of survey. The vibration was
dominated by the operating frequency of the motor. Bearings condition show
signs of deterioration as compared to the last survey.

Equipment is deemed fit for continued service.


Trend Further. Monitor bearing condition during the next survey.
Recommendation:

file://C:\Users\DiagnoVeritas\Desktop\CSC Dynamic Vision\Dynamic Vision\030 - No1 ... 17/3/2008


031 Page 1 of 1

Client : ChevronTexaco Shipping Corporation


Vessel : Dynamic Vision
Date : 5th January 2008
Equipment (031) : #2 Stern-tube LO Pump
Remarks : Fujairah
Equipment Status : Marginal (Bearing Condition)

Measurement Overall Vibration in mm/sec


Points Jan-08 Jul-08
A - 1L 0.019
A - 1T 0.027
A - 1V 0.022
B - 2L 0.024
B - 2T 0.028
B - 2V 0.024
C - 3L 0.024
C - 3T 0.028
C - 3V 0.022

Summary of Result : Equipment condition is satisfactory at time of survey. The vibration was
dominated by the operating frequency of the motor. Bearings condition show
signs of deterioration as compared to the last survey, similar to that of Stern-
tube LO Pump #1.

Replace motor and pump bearings at conveniece.