Industrial IT

For bay control solutions


BCS 590 / BCS 593 GIS above 170 kV

............. ...
..............

. ......... .. ...........
... . . ......
...... .. .......
The essential first improvement step

The benefits of advanced power system


management require the automation of local
operations and the collection, evaluation and
forwarding of data from the primary equipment
to higher level systems.

In this context, the BCS590 and BCS593


solutions for bay-level control functions are
an integral part of systems for substation
automation mainly for sub-transmission and
transmission level substations. They belong
to the BCS family of modular pre-engineered
solutions and are dedicated for single and double-
busbar configurations. The ABB intelligent
electronic device REC316*4 with its
comprehensive control library is used as
the bay controller.

Typical applications of BCS590 and BCS593: Highlights

■ High safety standards


Power utilities, transmission level gas Examples:
■ Modular scalable solutions
isolated switchgear above 170kV
BCS593 modern control: ■ Fully integrated into the ABB SA System
High voltage substations above 170kV for local control cubicle for a new double- ■ Proven function packages
installations with severe space constraints busbar indoor GIS substation with ■ Premium functionality
or high aesthetic requirements, such as: numerical protection including remote
■ Metropolitan areas connection to a Network Control Center.
■ Resort or environmentally protected areas
BCS590 modern control:
High voltage substations for installations local control cubicle to refurbish the
in heavily polluted environments, such as: older generation secondary equipment
■ Petrochemical plants for a single busbar indoor GIS 220kV
■ Cement plants transformer substation with numerical
■ Coastal Areas protection and control equipment.

High voltage substations for installations BCS590 conventional control:


with high reliability requirements, such as: control panel for a new conventionally
■ Chip manufacturers controlled single busbar indoor GIS
■ Petrochemical plants substation. Remote control from the
■ Critical consumers (hospitals, hotels Network Control Center is made via a
casinos etc.) remote terminal unit RTU.

Industrial IT is the ABB commitment to the real time


integration of automation and information systems
across the business enterprise.

2 ABB ABB 3
Bay control solution concept for BCS590 and BCS593 Modern and conventional control versions
of BCS590 and BCS593
The bay Control Solution Concept is a For both of the applications, two control Single busbar Double busbar
GIS >170 kV GIS >170 kV
standardized comprehensive solution for control cubicle executions are defined:
cubicles for all the types of switchgear that can ■ Modern control Modern BCS590 BCS593
occur in transmission and subtransmission and ■ Conventional control
Conventional BCS590 BCS593
busbar configurations.

Features

Common Features Specific features The modern control cubicle BCS590 modern control BCS593 modern control
is equipped with a microprocessor based Bay
BCS590 and BCS593 are two versions of ■ The BCS590 is designed for a
Controller REC316*4 and a BCM800 mimic.
the Bay Control Solution concept comprising single busbar configuration
The performance characteristics of this solution are:
control cubicles for high voltage gas isolated
■ The BCS593 is designed for a ■ high functionality
switchgear (GIS) for voltage levels higher than ■ simple integration in the ABB SA system via the
double busbar configuration.
170kV. LON bus
■ The main functional differences are in the ■ maximum reliability and availability.
The layout of the control cubicles and the
complexity of the interlocking logic and in
configuration of the devices as well as the main
the quantity of the high-voltage switchgear.
functionality are identical for both solutions.

The conventional control cubicle BCS590 conventional control BCS593 conventional control
mainly differs from the modern by the replacement

of the REC316*4 Bay Controller by conventional


relay logic. The most important characteristics

of this solution are:


■ the basic functionality for the secure operation

of the plant,
■ local operation from the BCM800 mimic,

■ a parallel terminal block for the connection of

the remote controls.

4 ABB ABB 5
Technical concept of the modern control Technical concept of the conventional control

The diagram shows the structure of the control In LOCAL Mimic HMI mode the BCM800 The diagram shows the structure of the
cubicle in the modern control. The data mimic is used as an input device for the conventional control. The main difference to the
exchange between the components is shown REC316*4. Operator actions are first transmitted modern control is the lack of the REC316*4 bay
diagrammatically. The arrows represent the data to the REC316*4, and are checked there for controller. In place of the REC316*4 a parallel
flow. The beginning and end of an arrow plausibility and for interlocking conditions. The terminal block is available that is used for the
represent an interface. Interfaces can be logical control command then goes from the REC316*4 remote connection to an RTU or station mimic.
or terminal blocks. The "Primary Interface via BCM800 to the Primary Interface Solution. The parallel interface uses exactly the same
Solution" also comprises electromechanical The Primary Interface Solution comprises the terminals on the BCM800 as the REC316*4 bay
relays and the marshalling of the cables. The output contactors for the control of the high controller. The switching dialogs correspond to
concept is very flexibly and modularly designed voltage switching devices. the dialogs of the EMERGENCY Mimic HMI
and permits customer specific adaptations to be mode for the modern control. Because of the
integrated very easily. In EMERGENCY Mimic HMI mode, the lack of the REC316*4 bay controller, all the
switching commands go directly to the Primary functions, with the exception of the alarm
Interface Solution. The REC316*4 is bypassed. handling and the Synchrocheck function are
The operator's comfort is therefore limited. conventionally implemented in the primary
In this mode, the interlocking logic is made interface solution block.
conventionally in the Primary Interface Solution
with cabling.

6 ABB ABB 7
Function packaging for BCS590 and BCS593 The modern control version for BCS590 and BCS593

The Bay Control Solution concept is based on The Modules


packaging. This enables customer specific
The REC316*4 Bay Controller
solutions to be made from predefined function
The functionality of the controls is significantly
packages. A standardized interface concept
increased by the use of the REC316*4 bay
guarantees that the individual packages fit
controller, and at the same time the number of
together seamlessly.
terminals, cables, and electromechanical relays is
reduced, which contributes significantly to the
Types of Packages
reliability of the complete control cubicle.
REC316*4
Base Package Customized Package
The predefined scope of the functionality is The customized package comprises any BCM800 Bay Control Mimic.
sufficient in order to locally control and monitor customer specific functions and extensions that ■ Intuitive operator guidance

is designed for maximum security; the status of


a GIS station safely. This is the basic execution are not in the Base Package or one of the Add-
the plant is clearly displayed in a singleline
to which extensions and modifications can be On Packages. The flexible interface concept
diagram.
made. allows customer specific functions to be
■ Mimic Layout
integrated, without influencing the functions
The inscriptions on the mimic are made with
Add-On Package of the Base Package or one of the Add-On
multi-color screen printing. The colors,
The Add-On Packages extend the functionality Packages.
inscriptions, and the arrangement of the objects
of the Base Package and can be used in any are tailored for each customer. An easy to use
combination.The predefined functions are editor supports the user for the creation of the
designed such that, starting from the basic mimic layout.

functionality, solutions can be made that fulfil ■ LOCAL Mimic HMI Mode
the highest requirements. In LOCAL Mode the BCM800 mimic serves as the
input device for the REC313*4 controller. Inputs
are monitored by the REC316*4 controller and
checked for plausibility. Incorrect operation that
could lead to damage to the primary elements is Mimic BCM800
prevented both in own bay itself and also between
different bays by an interlocking and blocking
logic, that is implemented in the REC316*4.

■ EMERGENCY Mimic HMI Mode

If the REC316*4 bay controller is out of service


because of a fault, a change can be made at any
time to Emergency Mode. In this operation mode,
all the HV switching devices can be controlled.
The interlocking and blocking is conventionally
made with auxiliary contacts.

RIO580 (option)
To extend the number of the inputs and outputs
of the REC316*4 controller, a separate RIO580
device is used. This can be equipped with both
digital or analog inputs and outputs. This
concept enables any number of inputs and RIO580

outputs to be used with the REC316*4.

8 ABB ABB 9
The modern control version for BCS590 and BCS593

Touchscreen (option) Features Characteristics


The BCS590 and BCS593 cubicles can be exten- ■ Protection and control information on one
■ The hybrid combination LOCAL Mimic Mode and
screen.
ded with an additional touchscreen to make EMERGENCY Mimic Mode
■ Singleline diagram representation of the status
maintenance and fault finding easier. The forms a secure solution, that enables both the
of the plant
touchscreen is provided with a comprehensive ■ Object orientated comprehensive alarm handling;
leaded operation by the bay controller, and also

application library. operation of the bay on the failure of the bay


e.g. an SF6 gas alarm would be presented in the
controller.
gas compartment diagram physically related
visually and with text. ■ The hybrid controls REC316*4 with BCM800
■ Clear presentation of measurands form a logical bay control unit with which up to 7
■ Customer specific representation of protection high voltage switching devices can be monitored
fault data, e.g. distance to the fault location and controlled in the basic version. As an option,
■ Execution of control sequences up to 8 high voltage switching devices are
– earthing of a bay supported.
– changing bus bars
■ Integration in the ABB station controls

is made via the LON BUS. This flexible concept


also supports the later connection to a remote
gateway or station control workplace without
additional engineering effort in the bay controller.
Therefore, the investment is secure for the future
in the case of a later extension of the station.
With this concept, benefits arise from the modern
ABB Station Automation and the higher-level
systems (ABB Advanced Power System
Management) both today and in future.

■ High functionality
Touchscreen integration concept
The modern REC316*4 controller is provided with
a comprehensive library of functions. The
synchrocheck, the programming possibilities, and
various protection functions offer special
potential for applications.

Touchscreen

BCS 593 base package

10 ABB ABB 11
The conventional control version for BCS 590 and BCS 593 Functional description of the base package

BCM800 Mimic Terminal block for the protection recorded with mechanical counters. A total of 6
The BCM800 mimic is the key component of In the control cubicle, there is a terminal block counters are available. For the modern control,
the conventional control. In the basic execution for the connection of Trip Main1, Trip Main2, the switching operations and pump starts are
up to 7 high voltage switching devices can be and Autoreclosure (AR). This simplifies the additionally acquired in the REC316*4 controller
monitored and controlled. As an option, up to protection cubicle. and are transmitted via the LON interface.
8 high voltage switching devices can be
monitored and controlled. Operations counters for circuit Pump control
breakers and pumps Automatic control of the hydraulic pump or
Characteristics The single or three pole switching operations of compressor for maintaining the necessary
■ Local control
the power switches and the start-up of the operating pressure.
is identical with the EMERGENCY Mimic mode
pump in the case of a hydraulic drive are
of the modern controls.

■ Remote control

the higher level components are connected via


a terminal block.

■ The functionality

is designed to control and monitor the main


equipment safely and reliably. Interlocking, alarm
annunciation, display of measurands and
operation counters for the power switches and List of functions of the base package for BCS590 and BCS593
the pumps are all part of the basic functionality.
The following list gives the functionality of the base package for both types of controls:

BCS 590 base package Function Modern Conventional


control control
Terminal block for the protection Yes Yes
Operations counters for circuit breakers and pumps Yes Yes

Benefits of the BCS590 and BCS593 concept Pump control Yes Yes
Anti-pumping Yes Yes
Pump start cascading Yes Yes
■ Proven packages ■ Seamless integration in the ABB station controls
Pump supervision Yes Yes
there are proven packages that can be assembled (modern control only)
Operating pressure supervision Yes Yes
to form a solution based on modular principles. and in the ABB advanced power system
Pole discrepancy monitoring and trip function Yes Yes
This reduces the commissioning time to a minimum. management higher level systems enable unlimited
Alarm annunciation Yes Yes
access to process data and its processing into
■ Clear scope of supply
Interlocking and blocking Yes Yes
information that is of vital significance for the
already at the offer stage, the exact scope of the Mechanics RESP 97 series Yes Yes
efficient operation of a power network.
functionality is defined and documented. Measurand display Yes Yes
The bay control solutions (BCS) are integrated via
This saves the customer time and resoures for LOCAL mimic HMI mode Yes No
a LON BUS in one of the ABB SAS systems from
project management. EMERGENCY mimic HMI mode Yes Yes*
SAS510 to SAS570.
SA integration Yes No**.
■ Standardized interfaces Interlocking and blocking display Yes No
■ Modifications are possible later
enable the integration of application specific Synchrocheck Yes No***
(modern control only)
extensions without the need to make corresponding Event list Yes No
if for operational reasons, e.g. a manned station
modifications to the standard packages. Breaker position indication per phase Yes No
is to be converted to a remote controlled station,
this does not require any modifications to the Transmission of measurands
■ Scalable solutions from conventional to modern
control cubicle configuration. to the higher station level (SA system) Yes No
support a very wide range of applications.
A later upgrade of the functionality is very easily
■ High quality standards *) The local mimic HMI of the conventional control is the same as the EMERGENY mimic HMI mode
possible. In this way, a conventional control can be
every component used such as auxiliary relays of the modern control.
upgraded to a modern one later.
and intelligent electronic devices IEDs are proved **) A parallel terminal interface is available.
and fulfil the high ABB quality requirements. ***) The synchrocheck is implemented with a synchrocheck relay. This is available as an add-on package.

12 ABB ABB 13
Functional description of the base package

Anti-pumping Pole discrepancy monitoring Mechanics


Anti-pumping control prevents the repeated, and trip function
Terminal blocks
undesired closing of a circuit breaker in the case The circuit breaker pole discrepancy monitoring
The base package is equipped with terminal
of a persisting CLOSE command followed by function detects a discrepancy in the pole
blocks for bolted cable connections (1.5 sq. mm).
an OPEN command. The circuit breaker positions during a closing operation and after a
If plugs or other cross sections are used the
remains in the OPEN position, and the close defined time delay, it actuates the three-phase
corresponding add-on package has to be selected.
command is ignored. opening operation of the breaker poles that are
in the closed position. If the three CB poles are The RESP 97 series supports many additional
Pump-start cascading mechanically coupled such that pole discrepancy features that can be selected by using the
Too many simultaneous pump starts would cannot occur, this function is not operational. Customized Package, e.g. color, hygrostatic or
drain the station DC battery too much. thermal heating etc.
Therefore, only one pump can run at a time. Alarm annunciation
In the modern control the 14 LEDs of the Paneling
Pump supervision REC316*4 are used to indicate alarms. For the The standard door at the front of the cubicles has
The number of pump or compressor starts and conventional control, an alarm annunciation a glass window so that the front of the REC316*4
the running time is supervised in order to device is provided. The alarm add-on package is always visible for the alarm LEDs and display,
obtain an early indication of problems with the extends the alarm handling functions of the base the tapchanger REGSys TM HMI and the
hydraulic or pneumatic circuits. In the case of an package. BCM800 HMI.
oil or air leak, the pump starts more frequently
to restore the operating pressure. If the pump Interlocking and blocking Features
running time until the oil pressure is restored is In order to prevent incorrect operation by the ■ Dimensions 2200x800x800

(height, width, depth) (used if the primary cables


shorter, this may be an indication of a nitrogen operator, a blocking and interlocking logic is
are connected via terminal connectors)
gas leak in the gas compartment of the hydraulic implemented. Blocking conditions are defined
■ Standard protection conforming to class IP 40
accumulator. In this case, preventive for all types of switching device. For example, a according to EN 60529. Other protection classes
maintenance can be made before the gas circuit breaker must not be closed as long as a are available with the customized package IP 43,
pressure is too low for safe CB operation. protection trip exists, or a disconnector must IP50, IP54.
not be switched, as long as the associated circuit ■ Normally with convection cooling via louvres

in the lower part of the door and the outlet around


Operating pressure supervision breaker is closed or the manual operation crank
the roof.
The operating pressure control functions are is in position. The interlocking logic determines
■ Can be supplied with a right or left opening door.
executed in the REC316*4, to supervise the the release of the switching operations based on ■ Lighting is activated by a door switch, lamp E27
operating pressure of a hydraulic or pneumatic the high-voltage switchgear position signals. ■ Colors NCS 1704-Y15R, RAL7032, RAL7035

operating mechanism. It is a basic safety rule, For this, both the positions of the high-voltage (other colors are available by selecting the
that a CB operating mechanism must have switching devices in its own bay (bay customized package)

sufficient operating pressure for opening if it interlocking) and also the positions of the other
was accidentally closed onto a fault. In the case bays (interbay interlocking) are taken into BCS 593 modern bay control solution
of low pressure, first the AUTO-RECLOSURE account. An example of interbay interlocking is:
operation is blocked, and then the closing a busbar disconnector must not be closed if the
operation and finally the opening operation are corresponding busbar earthing switch is closed.
blocked. In order that the interlocking is also provided in
emergency operation if the Bay Controller has
failed, the blocking logic and the interlocking
logic are made conventionally with relay logic
and cabling.

14 ABB ABB 15
Functional description of the base package Functional description of the add-on packages

Measurand display Transmission of measurands to the Plug connection


A digital instrument display is integrated in the higher station level (SA system) The plug connection package is designed to
BCM800 mimic. All the measurands that are The REC316*4 Bay Controller acquires all the connect the primary equipment with plugs
important for operation, such as currents, currents, voltages, frequencies, and phase angles instead of terminals. It contains all the parts and
voltages, and active and reactive power are and calculates the active and reactive power. All material that are necessary for the plug
displayed. these values are transmitted via the LON bus connection. An important requirement is the
interface, and are therefore available to the increased space requirements for the plugs.
Interlocking and blocking display higher level applications. The control cubicle is therefore extended by an
In LOCAL Mimic HMI mode, the operator is additional half cubicle and has the dimensions
informed about possible interlocking and 2200x1200x800 (height, width, depth).
blocking conditions when the corresponding
high voltage switchgear is selected. In the case SF 6 alarm Features / Benefits
of an interlock condition, the execution of the The base package includes two group alarms ■ Up to 30 alarms for SF 6 alarms per cubicle,

5 chambers * 2 alarms * 3 phases


switching command is blocked in order to only (refill and urgent) for the entire bay. The
■ Integrated in the SA interface (LON interface)
prevent damage to the switchgear and SF6 alarm package allows the SF6 gas alarm
(option for the modern solution only)
endangering personnel. The complete operator functionality to be extended by monitoring each ■ Display of the alarms on the alarm unit
guidance is designed for maximum comfort and gas compartment separately. Two alarm levels
safety. per gas compartment are defined, (refill and
urgent). Refill is a low-pressure warning and
Synchrocheck signifies the need for gas replenishment. The
The Synchrocheck is included in the Base insulation capability and switching capacity of
Package and is implemented in the REC316*4 the GIS is still maintained. The urgent alarm
controller. Therefore, an additional relay for the indicates an unsafe operating condition, which
Synchrocheck is not required. The integrated causes the corresponding switchgear to be
Synchrocheck increases the reliability and blocked.
therefore the availability, as the fewer the
number of components that are required for a
function, the higher is the total availability.

Event list
The REC316*4 maintains an event list where all List of the add-on packages for BCS590 and BCS593
the events are stored with millisecond accuracy.
The event list can be presented on the
Name Available for the modern Available for the conventional
REC316*4 display. control control
Plug connection Yes Yes
Breaker position indication perphase SF6 alarm Yes Yes
The REC316*4 receives the circuit breaker Tap changer Yes Yes*

position signals separately for each phase. Not integrated in the SA system

Touchscreen Yes No
Changes of position are stored with millisecond
Comfort Yes No
accuracy in the internal event list and are also Protection and recording Yes No
sent to the LON interface. They are therefore
available to the higher level SA applications.

16 ABB ABB 17
Functional description of the add-on packages

Tap changer Functions: Protection and Recording Scope of the Protection Functions
The tap changer package is designed for ■ Regulation of tap-changer transformers This package uses the different possibilities of ■ Definite time over/ undervoltage protection

■ Integrated statistical function of all tap-changer ■ High set over/ undervoltage protection
transformer regulation. The kernel of this the REC316*4 bay controller. This function
TM movements (total number of changes, number of ■ Definite time overcurrent protection with inrush
package is the REGSys tapchanger controller package comprises various protection and
changes under load / per tap) detection
that is equipped with a LON interface and that ■ Recording of voltage and visualization via the
monitoring functions. ■ High set overcurrent protection
can be easily integrated in the higher level SA regulator display or PC ■ Inverse time overcurrent protection

System with the modern control. ■ Dynamic transformer group assignment according ■ Thermal overload protection

to the busbar image ■ Frequency protection

■ up to 3 transformers ■ Rate-of-frequency change

■ double busbar ■ The product range of the complete function

■ 1 bus coupler, 2 section couplers library of the RE.316 is available for customer
■ Current inputs (-20mA...0…+20mA) for specific solutions
transformer monitoring (J, P, ...) ■ Four independent, user-selectable setting groups

■ Current output (-20mA...0…+20mA) for set point ■ Multi-activation facility for the available functions

output, strip chart recorder


■ Interface to the SA IBB bus (LON Bus)
Disturbance Recording
Disturbance recording of freely selectable analog
REGSys tapchanger controller inputs

Sequence of events recorder


With a resolution of 1 ms

Comfort Functions:
This package comprises a complete range of ■ 8 BCM800 mimic LEDs

The BCM800 is equipped with 8 LEDs. These


functions that are a useful extension of the
LEDs are used for alarm annunciation for the high
functions of the base package. The kernel of the
voltage switching devices. The LEDs are
package is an RIO580 that extends the positioned on the mimic such that there is a clear
REC316*4 by an additional 32 digital inputs / association of the alarm to the switching device.
outputs.

Position indication
and alarm LEDs

■ Three-pole Position Acquisition for the Fast

Earthing Switch.
In the Base Package the position of the fast
earthing switch is acquired for each fast earthing
switch. With this option the position signal is
acquired for each pole and is made available to
the SA interface (LON interface).

■ Pump alarm indicator and acknowledgement

pushbutton on the BCM800 mimic.


An additional alarm indicator and
acknowledgement pushbutton for the pump
alarms is installed on the BCM800 mimic. The
pushbutton indicates a pump alarm. By pressing
the button, the alarm is acknowledged and the
control of the pumps is enabled.

18 ABB ABB 19
2000 - 12.01 - Printed in Switzerland

ABB Switzerland Ltd


Utility Automation
Brown Boveri Strasse 6
1KHA - 000 732 - SEN

CH-5400 Baden/Switzerland
Phone +41- 58 - 585 77 44
Fax +41- 58 - 585 55 77
e.Mail substation.automation@ch.abb.com

www.abb.com/substationautomation

The Industrial IT wordmark and all mentioned


product names in the form XXXXXX IT are registered or
pending trademarks of ABB.

You might also like