Download as pdf
Download as pdf
You are on page 1of 17
SIVNT User Manual Inverter pure sine wave withAC charger — Dear Customers a Its very grateful to you for trusting our company and selecting our products! Before using this product, please read carefully this user manual, including installation, using, failure investigation and other important information and suggestion, we also suggest you keep this manual well! Catalogue 1Product Features i 2installation and storage Guide ——-—-—--—— 4Product Features ‘Double CPU intelligent control technology, excellent performance «The grid mode/ battery mode could be set, application flexible ¢ Intelligent fan control, safe and reliable Pure sine wave AC output, and be adapt to alll kinds of loads; LCD display equipment parameter in real-time, operation status be clear at a glance Output overload, short circuit protection, various of automatic protection and alarm warning; 2Installation, Storage instruction () Unpacking Inspection 1.1 Open the package, inspect product accessories,including:1 host,1piece user manual | 1.2Inspect whether the machine have been damaged during the transport or not, If it have some damage, don't start the machine, contact the logistics company and dealer. lation, Storage Notes cl installation should be operated by professionals , or transport machine,please take proper protection chine from low temperature environment to high in damp, inflammable and explosive i. Don't cover and block vents, clearance so that having a equipment is not 3Equipment appearance graphical representation guide (1) Equipment appearance view (2) Guide @-- LCD display @- ON/OFF button, function key @-~ Battery input terminals @-RS232 communication interface(optional function) ©- AC output socket ©-- AC input/output termian! 4 Equipment wiring diagram (1) 12VDC series battery wiring diagram (2) Input/Output wiring diagram Hose EecicAppance Mains socket a Direction for using of wire diameter n for using of battery, AC Eeeafoutput wire diameter: Bemerectoclpower(W) _ Rated battery(V) x 5A/mm_ Rated power(W) Rated AC voltage(V) x 5A/mm_ 1000W => © 10(mni) 24V x 5A/mm fl Teh loUOS 4IO/NO Puog ei6uls sseid uo} yim epow Bupyom juewdinbe ou! Jajua ‘sseid YoYs yyIM UOeNue}e punos uojonu}sul ‘918 BuleM Wwe|e ‘Ayoeded peo| ‘Ayjoedeo Aieyeq “apoul JeHeAuUt ‘apow puB ‘Aouanbey ‘aBeyon yndino~ndul :se yons ‘snyeys Gupyom juauidinba ey) Aejdsip ued eoepejul shox uonouny pue Aeidsip GO Ft uononysu uonequasasdas jeorydes6 Aejdsip G97 yjoued (b) suononsjsul Bunesedog 1.3 LCD display instruction BBE BES GBB: Equipment parameter instruction Lep . , Function instruction display ; : 888. AC input voltage parameter AC output frequency parameter Equipment working mode selection Grid priority mode Battery priority mode O te o3= AC output voltage parameter = | ap Battery icon instruction Status Battery voltage values/12y, «a + AC Twinkle _ SALW, *A eee I N.SV) “A Lighten 11.6~11.8V; *A Lighten Lighten Pes) | | Error code and solution iM ea a Faulty Solution | Kindly contact sales if still EG} | Overcurrent of MOSFETS board having this issue after restarting Check whether i's overloaded | en2 Output short circuit seriously or shortcircuit inside applicances loaded | Check whether it's overloaded, £03 Applicance Overloaded and remove some loads not important Check whether fan is working well or the air dust for cooling be blocked Make sure battery be fully Check whether battery connection and configuration correct charged, or replace new battery Fix the two cables after they are interchanged Kindly contact sales if still having this issue after Load icon instruction moe Function instruction display = Output overload reminder fee | 0%~25% | 25%~50% | 50%~75% | 75%~100% 100% 100% 00% 00% 00% 2% 2% 2% x (2) Panel key/LCD setting instruction Function key Operating instructions | tne. Long press for 1 second, buzzing 1 time, start mute state; Long press for 1 second again, sy buzzing 2 times, close mute stage; Long press for 5s, 01,03 mode can be recurrent selection, it will take effect after restarting: Battery priority mode G3 ee | Long press for 2s, buzzing 1 time, equipment start output (3) Working mode instruction Fe Working ; Running state Icon | mode g After starting the inverter and the electricity input working well, inverter supply power to i id bypass regulated, and | The grid loads via the grid bypa: 9 ‘ charge battery;When the grid happened 0 oe preferred abnormal such as overvoltage, mode low-voltage,massive distortion etc, inverter can supply high quality power via inner modules to loads ef With the grid working well and battery be charged fully, the grid works standby, inverter supply power from battery to loads. When battery power drops too low to supply power, | inverter supply power to loads via the grid bypass regulated but not charge battery. This _— |mode is designed for new energy power system such as wind or solar power system. (4) Working mode state (Battery working status) When the grid input abnormal or under battery preferred mode, supply Power to load by battery storage power convert to AC power via inverter or under battery preferred(but low battery), d regulated voltage via inverter bypass ——— ——i—t (5) Audible alarm reminder instruction Buzzing Buzzer is no tweet under default prohibit state Equipment Buzzer tweet 4 times every 15s, | running normal | Buzzer | dicate the equipment operated sams under battery inverter state Battery high | Buzzer tweets 4 times per second, alarms high voltage alarm | voltage | Battery low Buzzer tweets 2 times per second, alarms low voltage alarm | voltage my crete crete Buzzer alarm 2 seconds pause 1 second alarm (6) Electric generator connection announcements ct electric generator, it needs operating as below: up electric generator and after it running stable, make electric ‘output power supply be connected into the equipment input ‘sure the equipment output is no-load, then start up the uipment starting, then connect load one by one ctric generator capacity should be 2~3 times of 6Care and Maintenance ©1) This series need rarely care battery only Need ae Keeping charging so that can 9et expected lifetime. or <2) Ifthe equipment will not be USed for long-term, we suggest it should 3 be charged 1 time every 4-6 month, Usually, the battery can be Used for mo 3-5 years, if it has some Problem, then the battery should be changed as T Soon as possible. When Changing battery, it must be Operated by lero Professional and obey battery Supplier indicate ‘3) Before changing the battery, it must be closed equipment and break ‘away from the grid, close the battery switch.Take off the metal objects a Such as rings. (4) Connect the battery line, tiny spark in joint belongs to the normal Phenomenon, and will not cause harm to the personal safety and hess “quipment. Never connect the battery positive and negative into short or Pe the reverse. s Buzz Far s ie 2 Vv infor prob! conn zJudgment and treatment for simple faults 4 warning :High voltage inside the device! Do not open it by yourself or try to do maintenance, so as not to be in danger! d Fault Possible causes | solution a = = 4 Strong out of Press again the str S ‘The grid ional Ee uae restoration fuse holder part y oa Make sure battery be full of | Battery undercharge | one charging normally k s Machine connect load 5 Time degradation of | Move away non-key loads a. overcharge | Machine with loads - | umin and cant | PlC2s© Contact with CSR Battery burn-in and can’ | and get battery need charge enough power changing module The grid input line or battery input line is in. | Check and reconnection bad connect Make sure battery be full of Low battery charge normally Move away non-key loads Check fan and hear dissipation whether be blocked Normal engineers, please provide the following _ date/complete description of the battery specification, all of the —_ Perecnmology baeMercte hie pene a 1000w ~~ lea t 12/24VDC Rated voltage Battery «| aaa a 145-275VAC | ines ae 45-65Hz re ice 220VAC; 45%( Inverter mode) pay 50/60H241%* Inverter mode) aes | Pure sine wave ~ Switchi <10ms( typical oad) >85% (80% Resistance load) 110-120%/308; >160%/300ms: overvoltage/lowvoltage, overload, short circuit Protection, overtemperature protection, etc.

You might also like