Professional Documents
Culture Documents
c311 AAT2 en
c311 AAT2 en
AAT2
Tina-quant α1-Antitrypsin ver.2
• Indicates cobas c systems on which reagents can be used
Order information Roche/Hitachi cobas c systems
Tina-quant α1-Antitrypsin ver.2 cobas c 311 cobas c 501/502
100 tests Cat. No. 03005771 322 System-ID 07 9008 7 • •
Calibrator f.a.s. Proteins (5 x 1 mL) Cat. No. 11355279 216 Code 656
Calibrator f.a.s. Proteins (5 x 1 mL, for USA) Cat. No. 11355279 160 Code 656
Precinorm Protein (3 x 1 mL) Cat. No. 10557897 122 Code 302
Precinorm Protein (3 x 1 mL, for USA) Cat. No. 10557897 160 Code 302
Precipath Protein (3 x 1 mL) Cat. No. 11333127 122 Code 303
Precipath Protein (3 x 1 mL, for USA) Cat. No. 11333127 160 Code 303
Diluent NaCl 9 % (50 mL) Cat. No. 04489357 190 System-ID 07 6869 3
AAT2
Tina-quant α1-Antitrypsin ver.2
Specific performance data References
Representative performance data on the analyzers are given below. 1. Lievens M, Bienvenu J, Buitrago JMG et al. Evaluation of four
Results obtained in individual laboratories may differ. new Tina-quant assays for determination of α1-acid glycoprotein,
α1-antitrypsin, haptoglobin and prealbumin. Clin Lab 1996;42:515-520.
Precision 2. Greiling H, Gressner AM, eds. Lehrbuch der klinischen Chemie und
Precision was determined using human samples and controls in an Pathobiochemie, 3rd ed. Stuttgart/New York: Schattauer 1995:231-232.
internal protocol. Repeatability* (n = 21), intermediate precision** 3. Schneider M, Pott G, Gerlach U. Alpha-1-Antitrypsin Mangel.
(3 aliquots per run, 1 run per day, 21 days). Klin Wschr 1986;64:197-205.
The following results were obtained: 4. Tietz NW, ed. Clinical Guide to Laboratory Tests, 3rd ed.
Repeatability* Mean SD CV Philadelphia, PA: WB Saunders 1995:66-67.
g/L g/L % 5. Johnson AM, Alper CA. Deficiency of α1-antitrypsin in childhood
(µmol/L, mg/dL) (µmol/L, mg/dL) liver disease. Pediatrics 1970;46:921-925.
Precinorm Protein 1.14 (21.0, 114) 0.01 (0.2, 1) 0.8 6. Silverman EK, Pierce JA, Province MA et al. Variability of pulmonary
Precipath Protein 1.89 (34.8, 189) 0.02 (0.4, 2) 0.9 function in alpha-1-antitrypsin deficiency: Clinical correlation.
Ann Intern Med 1989;111:982-991.
Human serum 1 1.04 (19.1, 104) 0.01 (0.2, 1) 0.8
7. Use of Anticoagulants in Diagnostic Laboratory Investigations. WHO
Human serum 2 1.58 (29.1, 158) 0.01 (0.2, 1) 0.8
Publication WHO/DIL/LAB/99.1 Rev.2. 2002.
Intermediate Mean SD CV 8. Baudner S, Bienvenu J, Blirup-Jensen S, et al. The Certification of a Matrix
precision** g/L g/L % Reference Material for Immunochemical Measurement of 14 Human
(µmol/L, mg/dL) (µmol/L, mg/dL) Serum Proteins, CRM470, Report EUR 15243 EN, 1993:1-186.
9. Young DS, Huth EJ. SI Units For Clinical Measurement.
Precinorm Protein 1.12 (20.6, 112) 0.01 (0.2, 1) 1.1 American College of Physicians, 1998.
Precipath Protein 1.86 (34.2, 186) 0.02 (0.4, 2) 1.2 10. Glick MR, Ryder KW, Jackson SA. Graphical Comparisons of Interferences
Human serum 3 1.05 (19.3, 105) 0.01 (0.2, 1) 1.4 in Clinical Chemistry Instrumentation. Clin Chem 1986;32:470-475.
Human serum 4 1.76 (32.4, 176) 0.03 (0.6, 3) 1.5 11. Breuer J. Report on the Symposium “Drug effects in Clinical Chemistry
* repeatability = within-run precision Methods”. Eur J Clin Chem Clin Biochem 1996;34:385-386.
** intermediate precision = total precision / between run precision / between day precision 12. Sonntag O, Scholer A. Drug interference in clinical chemistry:
recommendation of drugs and their concentrations to be used in drug
Method comparison interference studies. Ann Clin Biochem 2001;38:376-385.
α1-Antitrypsin values for human serum and plasma samples obtained on a 13. Nielsen CH, Poulsen HK, Teisner B, et al. Changes in blood levels
Roche/Hitachi cobas c 501 analyzer (y) were compared with those determined of proteinase inhibitors, pregnancy zone protein, steroid carriers
using the same reagent on a Roche/Hitachi 917 analyzer (x). and complement factors induced by oral contraceptives. Eur J
Sample size (n) = 119 Obstet Gynecol Reprod Biol 1993; 51:63-71.
Passing/Bablok15 Linear regression 14. Consensus values of the “Deutsche Gesellschaft für
y = 0.972x - 0.029 g/L y = 0.979x - 0.043 g/L Laboratoriumsmedizin”, the “Deutsche Gesellschaft für Klinische
τ = 0.976 r = 0.998 Chemie” and the “Verband der Diagnostica-Industrie e.V.” (VDGH).
DG Klinische Chemie Mitteilungen 1995;26:119-122.
The sample concentrations were between 0.880 and 3.35 g/L
15. Passing H, Bablok W, Bender R, et al. A General
(16.2 and 61.6 µmol/L, 88.0 and 335 mg/dL).
Regression Procedure for Method Transformation.
J Clin Chem Clin Biochem 1988;Nov:26(11);783-790.
A point (period/stop) is always used in this Method Sheet as the decimal
separator to mark the border between the integral and the fractional parts
of a decimal numeral. Separators for thousands are not used.
FOR US CUSTOMERS ONLY: LIMITED WARRANTY
Roche Diagnostics warrants that this product will meet the specifications
stated in the labeling when used in accordance with such labeling and
will be free from defects in material and workmanship until the expiration
date printed on the label. THIS LIMITED WARRANTY IS IN LIEU OF ANY
OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE. IN NO EVENT SHALL ROCHE DIAGNOSTICS BE LIABLE FOR
INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES.