SITRAIN

Introduction to HMI

© Siemens AG 2009. All rights reserved.


Add a new device

Device information is
displayed

Create panel with the


support of the wizard

SITRAIN
ST-MICRO1 / Einführung in HMI Page 2 Siemens AG © 2009
Connect an HMI device to the network

This address must be set


Lock symbol manually on the touch
Connection symbol panel later

SITRAIN
ST-MICRO1 / Einführung in HMI Page 3 Siemens AG © 2009
Device settings - General properties

Select interface

IP address is assigned
automatically

SITRAIN
ST-MICRO1 / Einführung in HMI Page 4 Siemens AG © 2009
Communication between PLC and touch panel

DB_OP

PN

SITRAIN
ST-MICRO1 / Einführung in HMI Page 5 Siemens AG © 2009
Setting the interface for project transfer

Transfer Settings OK

Channel 1:
Ethernet X Enable Channel

Advanced X Remote Control

Profinet Settings OK

Loader V01.00.00.01_19 Control Panel OK IP address

Specify an IP address
Transfer

IP address 192 168 111 101


Start
Transfer Subnet mask 255 255 255 0
Control
Panel

SITRAIN
ST-MICRO1 / Einführung in HMI Page 6 Siemens AG © 2009
WinCC Basic desktop for configuring

Project navigation Editing area Tools

Details view

Inspector window

SITRAIN
ST-MICRO1 / Einführung in HMI Page 7 Siemens AG © 2009
Input and output fields

SITRAIN
ST-MICRO1 / Einführung in HMI Page 8 Siemens AG © 2009
Buttons

Button

Action

Event

SITRAIN
ST-MICRO1 / Einführung in HMI Page 9 Siemens AG © 2009
Transfer configuration to the touch panel

PN

SITRAIN
ST-MICRO1 / Einführung in HMI Page 10 Siemens AG © 2009
Exercise 10-1:
Set IP address of touch panel

Loader V01.00.00.01_19 Control Panel OK Transfer Settings OK

Channel 1:
Transfer Ethernet X Enable Channel

Start
Advanced X Remote Control
Transfer
Control
Panel Profinet Settings OK

IP address

Specify an IP address

IP address 192 168 111 101

Subnet mask 255 255 255 0

SITRAIN
ST-MICRO1 / Einführung in HMI Page 11 Siemens AG © 2009
Exercise 10-2:
Insert touch panel in project from library

SITRAIN
ST-MICRO1 / Einführung in HMI Page 12 Siemens AG © 2009
Exercise 10-3:
Link touch panel to CPU

IP addresses -
show / hide

SITRAIN
ST-MICRO1 / Einführung in HMI Page 13 Siemens AG © 2009
Exercise 10-4:
Logically connect touch panel to CPU

1. Select connections

2. Drag and drop


connection

3. Rename
connection

SITRAIN
ST-MICRO1 / Einführung in HMI Page 14 Siemens AG © 2009
Exercise 10-5:
Check HMI tag interfacing

SITRAIN
ST-MICRO1 / Einführung in HMI Page 15 Siemens AG © 2009
Exercise 10-6:
Control conveyor model from touch panel

SITRAIN
ST-MICRO1 / Einführung in HMI Page 16 Siemens AG © 2009