Professional Documents
Culture Documents
Beams & Columns & Slabs According To ECP
Beams & Columns & Slabs According To ECP
C1 3.05284 Tension
If Tension Failure Put Failure
The Value Of ( J ) From The Table
J 0.71
C/d C1 J
0.125 4.854 0.826
0.1375 4.64 0.821
0.15 4.455 0.817
s
0.1625 4.291 0.813
0.175 4.146 0.808
0.1875 4.016 0.804
0.2 3.899 0.8
The Table 0.2125 3.793 0.795
O.K
0.225 3.697 0.791
0.2375 3.608 0.786
0.25 3.526 0.782
0.2625 3.451 0.778
16
0.275 3.381 0.773
0.2875 3.316 0.769
0.3 3.255 0.765
0.3125 3.199 0.76
0.325 3.146 0.756
0.3375 3.096 0.752
0.35 3.049 0.747
0.3625 3.004 0.743
0.375 2.963 0.739
0.3875 2.923 0.734
0.4 2.885 0.73
0.4125 2.85 0.726
0.425 2.816 0.721
0.4375 2.784 0.717
0.45 2.753 0.713
0.4625 2.724 0.708
0.475 2.696 0.704
0.4875 2.67 0.7
0.5 2.645 0.695
e
J
0.826
0.821
0.817
0.813
0.808
0.804
0.8
0.795
0.791
0.786
0.782
0.778
0.773
0.769
0.765
0.76
0.756
0.752
0.747
0.743
0.739
0.734
0.73
0.726
0.721
0.717
0.713
0.708
0.704
0.7
0.695
Shear R.F.T in Beams
ENG / Mohamed M
Fcu Mpa 25
b mm 120
t mm 700
Qu max 12 ton
qu concrete 1.538462 N/mm2
Allowable Stresses
Calculated R.F.T
Min R.F.T
hamed Magdy
n 2
Fy Mpa 240 Ast / s 0.30146
Assume f 8 S 166.654 mm
7 f 8 / m\
Calculate R.F.T
For Slabs
ts mm
ENG / Mohamed Magdy
220
Cover mm 25
Fy MPA 360
As min 330
Assume f 12 3 f 12
Assume Mesh
Additional R.F.T.
Mu t.m
med Magdy
7 f 12
f
4.44
Design Of Columns
ENG / Mohamed M
Width mm 300
Length mm 1200
Horizontal 2 O.K
Vertical 6
Ʃ Stirrup Length 3800
D mm 500
O.K
Circular Columns ( Spiral )
O.K
P 95.9 mm