Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Alarm List Page 15 of 52

ME Alarm Codes Version 01.00 (G4)

Cable break The slider voltage is in the cable break area.


Check the cabling to this angle transducer.
Hints for troubleshooting:
• The angle transducer may not be supplied with power or has moved
out of position too far. A cable break on the power supply is possible
too.
Use the PC service software to measure the voltage on the
corresponding analogue input.
• Voltage > 4.8 V:
- Short circuit of the slider to 24 V.
- Angle transducer too far out of position?
- Cable break of the ground signal
• Voltage < 0.2 V:
- Short circuit of the slider to ground or against vehicle mass
- Cable break between slider and angle transducer.
- Cable break between power supply and angle transducer.
- Angle transducer too far out of position?
• Potentiometric transducers “530 xxx”:
For precise localization, measure the following resistances with the
steering computer unplugged:
- Between terminal +5V-Ref and ground. As min. 2 tracks are
connected in each case, approx. 1000 Ohm (750 – 1250 Ohm)
should be measured. In the event of deviations, there is a cable
break / short circuit of the output "5V-Ref." or of "0V-Signal".

Short circuit Short circuit between the two angle transducer tracks.
Check the cabling to this angle transducer.
Parameter prog Parameter P_64 programmed incorrectly.
Signal failure Both signals of the angle transducer are instable or erroneous. This
occurs in conjunction with other errors at this angle transducer.

Hints for troubleshooting:


• The other errors give more detailed information about the kind of the
signal failures.
• Observe the signal voltages and check them for irregularities.

EHLA_Manual_Part 4_V0100_G4 2 Alarm list

You might also like