Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

IMPACT 4.00.51.

00-SNAPSHOT 07/11/17

‫ﻣﻌﺮﻑ ﺍﻟﺸﺎﺳﻴﻪ‬ ‫ﺍﻟﻤﺴﺎﺭ‬


7281/Diagnostics//MID 150 Electronically controlled suspension, fault codes

‫ﺍﻟﻄﺮﺍﺯ‬ ‫ﺍﻟﻤﻌﺮّﻑ‬
FH 131077817

‫ﺗﺎﺭﻳﺦ ﺍﻟﻨﺸﺮ‬ ‫ﺍﻟﺘﺸﻐﻴﻞ‬/‫ﺍﻟﻤﻌﺮّﻑ‬


17/04/12

MID 150 Electronically controlled suspension, fault codes


Note: More information about fault codes is available in Guided Diagnostics.

Fault Code Function FMI Error


PID152 Nr of ECU resets 12 Faulty unit or component

PPID111 Air Suspension Icon 7 Incorrect reply from mechanical


system.

PPID111 Air Suspension Icon 14 Unknow fault

SID1 Solenoid Valve axle 1 right 5 Abnormally low current or open


circuit

SID1 Solenoid Valve axle 1 right 6 Abnormally high current or short


circuit to ground

SID1 Solenoid Valve axle 1 right 7 Incorrect reply from mechanical


system.

SID2 Solenoid Valve axle 1 left 5 Abnormally low current or open


circuit

SID2 Solenoid Valve axle 1 left 6 Abnormally high current or short


circuit to ground

SID2 Solenoid Valve axle 1 left 7 Incorrect reply from mechanical


system.

SID3 Solenoid Valve axle 2 Right 5 Abnormally low current or open


circuit

SID3 Solenoid Valve axle 2 Right 6 Abnormally high current or short


circuit to ground

SID3 Solenoid Valve axle 2 Right 7 Incorrect reply from mechanical


system.

SID4 Solenoid Valve axle 2 Left 5 Abnormally low current or open


circuit

SID4 Solenoid Valve axle 2 Left 6 Abnormally high current or short


circuit to ground

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
‫يلصألا عيزوتلا تقو عم اًيلاح انه ةدراولا تامولعملا نمازتت‬، ‫رييغتلل ةضرع لظت اهنكلو‬. ‫اهيلع ةباقرلل عضخت ال ةعوبطملا خسنلا نأب ئراقلل هوننو‬.

1/7
IMPACT 4.00.51.00-SNAPSHOT 07/11/17

SID4 Solenoid Valve axle 2 Left 7 Incorrect reply from mechanical


system.

SID5 Solenoid Valve axle 3 Right 5 Abnormally low current or open


circuit

SID5 Solenoid Valve axle 3 Right 6 Abnormally high current or short


circuit to ground

SID5 Solenoid Valve axle 3 Right 7 Incorrect reply from mechanical


system.

SID6 Solenoid Valve axle 3 Left 5 Abnormally low current or open


circuit

SID6 Solenoid Valve axle 3 Left 6 Abnormally high current or short


circuit to ground

SID6 Solenoid Valve axle 3 Left 7 Incorrect reply from mechanical


system.

SID7 Solenoid Valve Central 5 Abnormally low current or open


circuit

SID7 Solenoid Valve Central 6 Abnormally high current or short


circuit to ground

SID7 Solenoid Valve Central 7 Incorrect reply from mechanical


system.

SID8 Block, axle 2/lifting axle 5 Abnormally low current or open


circuit

SID8 Block, axle 2/lifting axle 6 Abnormally high current or short


circuit to ground

SID8 Block, axle 2/lifting axle 7 Incorrect reply from mechanical


system.

SID10 Lift bellow control solenoid valve 5 Abnormally low current or open
circuit

SID10 Lift bellow control solenoid valve 6 Abnormally high current or short
circuit to ground

SID10 Lift bellow control solenoid valve 7 Incorrect reply from mechanical
system.

SID16 Height sensor axle 1 right 3 Abnormally high voltage or short


circuit to higher voltage

SID16 Height sensor axle 1 right 4 Abnormally low voltage or short


circuit to lower voltage

SID17 Height sensor axle 1 left 3 Abnormally high voltage or short


circuit to higher voltage

SID17 Height sensor axle 1 left 4 Abnormally low voltage or short


circuit to lower voltage

SID17 Height sensor axle 1 left 7 Incorrect reply from mechanical


system.
Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
‫يلصألا عيزوتلا تقو عم اًيلاح انه ةدراولا تامولعملا نمازتت‬، ‫رييغتلل ةضرع لظت اهنكلو‬. ‫اهيلع ةباقرلل عضخت ال ةعوبطملا خسنلا نأب ئراقلل هوننو‬.

2/7
IMPACT 4.00.51.00-SNAPSHOT 07/11/17

SID18 Height sensor axle 2 right 3 Abnormally high voltage or short


circuit to higher voltage

SID18 Height sensor axle 2 right 4 Abnormally low voltage or short


circuit to lower voltage

SID18 Height sensor axle 2 right 7 Incorrect reply from mechanical


system.

SID19 Height sensor axle 2 left 3 Abnormally high voltage or short


circuit to higher voltage

SID19 Height sensor axle 2 left 4 Abnormally low voltage or short


circuit to lower voltage

SID19 Height sensor axle 2 left 7 Incorrect reply from mechanical


system.

SID20 Height sensor axle 3 right 3 Abnormally high voltage or short


circuit to higher voltage

SID20 Height sensor axle 3 right 4 Abnormally low voltage or short


circuit to lower voltage

SID20 Height sensor axle 3 right 7 Incorrect reply from mechanical


system.

SID21 Height sensor axle 3 left 3 Abnormally high voltage or short


circuit to higher voltage

SID21 Height sensor axle 3 left 4 Abnormally low voltage or short


circuit to lower voltage

SID21 Height sensor axle 3 left 7 Incorrect reply from mechanical


system.

SID23 Pressure sensor axle 1 left 3 Abnormally high voltage or short


circuit to higher voltage

SID23 Pressure sensor axle 1 left 4 Abnormally low voltage or short


circuit to lower voltage

SID23 Pressure sensor axle 1 left 7 Incorrect reply from mechanical


system.

SID24 Pressure sensor axle 2 right 3 Abnormally high voltage or short


circuit to higher voltage

SID24 Pressure sensor axle 2 right 4 Abnormally low voltage or short


circuit to lower voltage

SID24 Pressure sensor axle 2 right 7 Incorrect reply from mechanical


system.

SID25 Pressure sensor axle 2 left 3 Abnormally high voltage or short


circuit to higher voltage

SID25 Pressure sensor axle 2 left 4 Abnormally low voltage or short


circuit to lower voltage

SID25 Pressure sensor axle 2 left 7 Incorrect reply from mechanical


system.
Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
‫يلصألا عيزوتلا تقو عم اًيلاح انه ةدراولا تامولعملا نمازتت‬، ‫رييغتلل ةضرع لظت اهنكلو‬. ‫اهيلع ةباقرلل عضخت ال ةعوبطملا خسنلا نأب ئراقلل هوننو‬.

3/7
IMPACT 4.00.51.00-SNAPSHOT 07/11/17

SID26 Pressure sensor axle 3 right 3 Abnormally high voltage or short


circuit to higher voltage

SID26 Pressure sensor axle 3 right 4 Abnormally low voltage or short


circuit to lower voltage

SID26 Pressure sensor axle 3 right 7 Incorrect reply from mechanical


system.

SID27 Pressure sensor axle 3 left 3 Abnormally high voltage or short


circuit to higher voltage

SID27 Pressure sensor axle 3 left 4 Abnormally low voltage or short


circuit to lower voltage

SID27 Pressure sensor axle 3 left 7 Incorrect reply from mechanical


system.

SID28 Pressure sensor lift bellow 3 Abnormally high voltage or short


circuit to higher voltage

SID28 Pressure sensor lift bellow 4 Abnormally low voltage or short


circuit to lower voltage

SID33 Remote control unit 7 Incorrect reply from mechanical


system.

SID43 Central 3/2 Solenoid Valve Axle 3 5 Abnormally low current or open
circuit

SID43 Central 3/2 Solenoid Valve Axle 3 6 Abnormally high current or short
circuit to ground

SID43 Central 3/2 Solenoid Valve Axle 3 7 Incorrect reply from mechanical
system.

SID231 SAE J1939 Data Link 2 Intermittent or faulty data

SID240 Programme memory 13 Calibration values outside the


limits

SID250 SAE J1708/J1587 data link 2 Intermittent or faulty data

SID253 Calibration memory EEPROM 0 Data applicable, but above normal


working range.

SID253 Calibration memory EEPROM 1 Data applicable, but below normal


working range.

SID253 Calibration memory EEPROM 2 Intermittent or faulty data

SID253 Calibration memory EEPROM 3 Abnormally high voltage or short


circuit to higher voltage

SID253 Calibration memory EEPROM 13 Calibration values outside the


limits

SID253 Calibration memory EEPROM 14 Unknow fault

PSID1 Power supply, level sensor 3 Abnormally high voltage or short


circuit to higher voltage

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
‫يلصألا عيزوتلا تقو عم اًيلاح انه ةدراولا تامولعملا نمازتت‬، ‫رييغتلل ةضرع لظت اهنكلو‬. ‫اهيلع ةباقرلل عضخت ال ةعوبطملا خسنلا نأب ئراقلل هوننو‬.

4/7
IMPACT 4.00.51.00-SNAPSHOT 07/11/17

PSID1 Power supply, level sensor 4 Abnormally low voltage or short


circuit to lower voltage

PSID2 Power supply, pressure sensor 3 Abnormally high voltage or short


circuit to higher voltage

PSID2 Power supply, pressure sensor 4 Abnormally low voltage or short


circuit to lower voltage

PSID2 Power supply, pressure sensor 14 Unknow fault

PSID3 Bogie switch 7 Incorrect reply from mechanical


system

PSID4 Trailer pressure sensor right front 3 Abnormally high voltage or short
circuit to higher voltage

PSID4 Trailer pressure sensor right front 4 Abnormally low voltage or short
circuit to lower voltage

PSID5 Trailer pressure sensor left front 3 Abnormally high voltage or short
circuit to higher voltage

PSID5 Trailer pressure sensor left front 4 Abnormally low voltage or short
circuit to lower voltage

PSID6 Trailer pressure sensor right rear 3 Abnormally high voltage or short
circuit to higher voltage

PSID6 Trailer pressure sensor right rear 4 Abnormally low voltage or short
circuit to lower voltage

PSID7 Trailer pressure sensor left rear 3 Abnormally high voltage or short
circuit to higher voltage

PSID7 Trailer pressure sensor left rear 4 Abnormally low voltage or short
circuit to lower voltage

PSID8 Load indicatior calibration memory 13 Calibration values outside the


limits

PSID9 Solenoid valve tridem axle 5 Abnormally low current or open


circuit

PSID9 Solenoid valve tridem axle 6 Abnormally high current or short


circuit to ground

PSID9 Solenoid valve tridem axle 7 Incorrect reply from mechanical


system.

PSID10 Solenoid valve tridem lift bellow 5 Abnormally low current or open
circuit

PSID10 Solenoid valve tridem lift bellow 6 Abnormally high current or short
circuit to ground

PSID10 Solenoid valve tridem lift bellow 7 Incorrect reply from mechanical
system.

PSID11 Central solenoid valve tridem axle 5 Abnormally low current or open
circuit

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
‫يلصألا عيزوتلا تقو عم اًيلاح انه ةدراولا تامولعملا نمازتت‬، ‫رييغتلل ةضرع لظت اهنكلو‬. ‫اهيلع ةباقرلل عضخت ال ةعوبطملا خسنلا نأب ئراقلل هوننو‬.

5/7
IMPACT 4.00.51.00-SNAPSHOT 07/11/17

PSID11 Central solenoid valve tridem axle 6 Abnormally high current or short
circuit to ground

PSID11 Central solenoid valve tridem axle 7 Incorrect reply from mechanical
system.

PSID12 Pressure sensor tridem axle 3 Abnormally high voltage or short


circuit to higher voltage

PSID12 Pressure sensor tridem axle 4 Abnormally low voltage or short


circuit to lower voltage

PSID12 Pressure sensor tridem axle 7 Incorrect reply from mechanical


system.

PSID13 Pressure sensor tridem axle lift 3 Abnormally high voltage or short
bellow circuit to higher voltage

PSID13 Pressure sensor tridem axle lift 4 Abnormally low voltage or short
bellow circuit to lower voltage

PSID14 Tridem axle switch 7 Incorrect reply from mechanical


system.

PSID15 Falim calibration memory 13 Calibration values outside the


limits

PSID16 Added function switch 7 Incorrect reply from mechanical


system.

PSID17 Falim level sensor 7 Incorrect reply from mechanical


system.

PSID19 Air Suspension channel front axle 7 Incorrect reply from mechanical
system.

PSID20 Air Suspension channel drive axle 7 Incorrect reply from mechanical
left system.

PSID21 Air Suspension channel drive axle 7 Incorrect reply from mechanical
right system.

PSID22 Air Suspension channel drive axle 7 Incorrect reply from mechanical
system.

PSID23 Air Suspension channel extra axle 7 Incorrect reply from mechanical
system.

PSID24 Air Suspension channel lift bellow 7 Incorrect reply from mechanical
system.

PSID27 Solenoid valve axle 4 Right 5 Abnormally low current or open


circuit

PSID27 Solenoid valve axle 4 Right 6 Abnormally high current or short


circuit to ground

PSID27 Solenoid valve axle 4 Right 7 Incorrect reply from mechanical


system.

PSID28 Pressure sensor axle 4 Right 3 Abnormally high voltage or short


Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
‫يلصألا عيزوتلا تقو عم اًيلاح انه ةدراولا تامولعملا نمازتت‬، ‫رييغتلل ةضرع لظت اهنكلو‬. ‫اهيلع ةباقرلل عضخت ال ةعوبطملا خسنلا نأب ئراقلل هوننو‬.

6/7
IMPACT 4.00.51.00-SNAPSHOT 07/11/17

circuit to higher voltage

PSID28 Pressure sensor axle 4 Right 4 Abnormally low voltage or short


circuit to lower voltage

PSID28 Pressure sensor axle 4 Right 7 Incorrect reply from mechanical


system.

PSID30 Solenoid valve Central fourth axle 5 Abnormally low current or open
circuit

PSID30 Solenoid valve Central fourth axle 6 Abnormally high current or short
circuit to ground

PSID30 Solenoid valve Central fourth axle 7 Incorrect reply from mechanical
system.

PSID32 Air Suspension channel tridem axle 7 Incorrect reply from mechanical
system.

PSID200 SAE J1939 Data Link, MID128 9 Abnormal update rate

PSID201 SAE J1939 Data Link, MID144 9 Abnormal update rate

PSID202 SAE J1939 Data Link, MID140 9 Abnormal update rate

PSID204 SAE J1939 Data Link, MID136 9 Abnormal update rate

PSID206 SAE J1939 Data Link, MID222 9 Abnormal update rate

PSID210 SAE J1939 Data Link, MID216 9 Abnormal update rate

PSID215 SAE J1939 Data Link, MID184 9 Abnormal update rate

Copyright to this documentation belongs to the Volvo Group. No reproduction, copying, change, amendment or other similar disposal is entitled without prior written consent by
the Volvo Group
‫يلصألا عيزوتلا تقو عم اًيلاح انه ةدراولا تامولعملا نمازتت‬، ‫رييغتلل ةضرع لظت اهنكلو‬. ‫اهيلع ةباقرلل عضخت ال ةعوبطملا خسنلا نأب ئراقلل هوننو‬.

7/7