Munters Data Center Cooling Solutions
Munters Data Center Cooling Solutions
Vision
• Your Perfect Climate
Mission
• Munters' mission is to be a globally leading supplier of energy efficient
solutions for air treatment and climate control technologies.
2
Over 60 years of experience in Evaporative Cooling technology
4
World of data
The Facts:
This year, we will have 4.9 billion
connected things....some predict that In 2015, over 1.4 billion smart
by 2020, the number of Internet- phones will be shipped and by 2020
connected things will reach or even we will have a staggering 6.1 billion
exceed 50 billion. smartphone users.
Machine-to-machine (M2M)
connections will grow from 5 billion at CISCO believes the IoT could
the beginning of this year to 27 billion generate $4.6 trillion over the next
by 2024, with China taking a 21% ten years for the public sector, and
share and the U.S. 20%. $14.4 trillion for the private sector.
8
From Modular to Hyperscale
9
Climate Conditions
10
Oasis IEC Family Product Evolution
2007 2008 2009 2010 2011 2012 2013 2014 2015 2016 2017
OASIS DCIE
GLOBAL
PRODUCT
Next Generation
Oasis IEC 2.0
• Flexible
• Efficient
• Suitable for all climates
• Resilient
• Global product / Global reach
• Configurable
• Scalable
12
ASHRAE
(Guidelines for Data Processing Environments)
Allowable
Allowable
+ DX Condenser Coil
Evaporative Cooling
Water Sprays
Hot Aisle Return
Room Supply 38°C
26°C
-
Room-Side Fans
DX
Polymer Heat
Top-Up Cooling Pack (DX Exchanger
or ChW) Cooling Water
Pump
Ambient Air Intake
Sump
Hours per year that Oasis™ IEAC can provide 23°C or
below for locations around EMEA
Based on Hot Aisle return air temperature of 35DegC
London (Gatwick)
Paris
Berlin
Barcelona Hours run with
EPX only
Madrid
Stockholm
Vienna
Moscow
Rome Hours run with
Istanbul EPX and
supplementary
Abu Dhabi cooling
0 1000 2000 3000 4000 5000 6000 7000 8000
London (Gatwick)
Paris
Berlin
Stockholm
Vienna
Moscow
18
Where is Energy Consumed?
Annual Energy Consumption
Typical Site: Chillers + CRACs
IT Load
PUE: 2.0
Data Hall Lighting
UPS Losses
Transformer Losses
VSD Losses
Generator Ancillaries
Tx no load losses
Miscellaneous
Fan Power
Chiller Power
Pump Power
Humidification Power
Compressor Energy
(kWh)
The largest energy consuming element apart from the IT load is the Compressor
no.
19
Where is Energy Consumed?
Even when Free Cooling
Chillers are used, the largest
energy consuming element
apart from the IT load
remains the Compressor
Compressor
Energy (kWh)
no.
20
Where is Energy Consumed?
Annual Energy Consumption
Best Practice: Indirect Air Optimisation IT Load
Compressor
Energy (kWh)
Compressor Energy may be significantly reduced by use of IAO
no.
21
pPUE Comparisons IEC vs Free cooling chiller
22
Oasis Capital cost won’t cost you more
no.
23
Financial Outcome - CAPEX
Capital Costs (CAPEX)
– When considering the lower capacity requirement of the electrical to mechanical power loads,
the plant, equipment and machinery power infrastructure can be reduced:
27
Indirect Evaporative Cooling
28
Dison video
29
Data Centre Test Facility
• Leakage testing.
• Controls and alarm simulation testing.
• Variable load performance testing, in a climate controlled
chamber 2°C up to 33°C WB, 45°C DB.
• 60,000m3/hr airflow capacity
• Real server rack simulation with up to 300kW load.
• Tests in accordance with ASHRAE Std 143-2015.
• Fully calibrated & certified by LEUVEN University. Climate Chamber - Dison
External Test Facility - Virginia White Space with Load Banks - Dison
31
•DigiPlex