Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Maintenance

ETMA-MR-PSTN-1 ETMA-MR-PSTN-1-I ETMA-MR-PSTN-2-I

ETMA-CAR ETMA-CAR-T ETMA-LND-FF-I ETMA-TRI

Summary This manual provides instructions for the maintenance of embedded telemonitoring and
alarming (ETMA PSTN) equipment and covers the ETMA PSTN releases 03.00 and later.

Modification 00 01 02 03 Prepared 16.12.2016 pandeyjy


KA No. 154137 154155 154212 154695 Reviewed 16.12.2016 nguyenk3
KA Date 23.12.10 01.09.11 07.06.14 25.02.17 Norms Chkd 16.12.2016 naidura
Released 25.02.2017 hugenema
AC TMA 1 (ETMA PSTN)
Format
Maintenance A4
Classification Lead Office
INVENTIO AG CH-6052 Hergiswil
11250 EB7
EJ 41700382 EN
Copyright © 2017 INVENTIO AG All rights reserved.
INVENTIO AG, Seestrasse 55, CH-6052 Hergiswil, owns and retains all copyrights and other intellectual property rights in this manual. It shall only be used by
SCHINDLER personnel or authorized SCHINDLER agents for purposes which are in the interest of SCHINDLER. Any reproduction, translation, copying or storing
in data processing units in any form or by any means without prior permission of INVENTIO AG is regarded as infringement and will be prosecuted.

Page 1/9
Table of Contents

1 Safety Advice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Safety Warnings Used in this Manual . . . . . . . . . . . . . . . . . . 3
2 Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
A1 * Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
A2 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 2/9
1 Safety Advice

1.1 Safety Instructions

 Exclusively for competent professionals.


 Current version of the safety manual and any local safety requirements must be
consulted and followed before initiating works.
 Wear appropriate personal protective equipment.

1.2 Safety Warnings Used in this Manual

The following types of safety warnings are used in the present manual.

DANGER

The safety warning with the signal word “Danger” is used to indicate a hazardous situation
which, if not avoided, will result in death or serious injury.

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 3/9
2 Preventive Maintenance

Overview

E8 E3 E2

PSTN

ETMA TACC
ETMA-MR
CO
ETMA-LND-FF JBF

UPS

ETMA-CAR
COP

IL ETMA-TRI ETMA-TRI E1

ETMA Configuration (simplex, duplex, multiplex) [35410; 20.07.2010]


Basic System

COP Car operating panel


E1, E2, ..., E8 Elevator installation 1, 2, 3 (simplex, duplex, multiplex)
EC Elevator controller
ETMA ETMA system (the shaded part in the graphic above)
ETMA-CAR ETMA device on the car (slave)
ETMA-MR-PSTN ETMA device in the machine room (master)
PSTN Public switched telephone network
TACC Telealarm call center
UPS Uninterrupted power supply (part of elevator controller)
Optional Parts

ETMA-LND-FF ETMA device (for firefighters) on the landing (optional, slave)


IL Inductive loop amplifier (optional)
JBF Firefighter switch (optional)
ETMA-TRI Triphonie module on the car roof/underneath the car (optional)

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 4/9
Related
Number Description
Documents
J 630009 Waste Disposal Instructions
EJ 604713 Diagnostics Telealarm Device TM2-TAM2 Rel. 3.3
EJ 41700383 Diagnostics AC TMA 1 (ETMA PSTN)

Refer to Schindler Application Portal PNC to view the documents.

Task List
Interval Description Refer to
Every Visit Trigger a test alarm call in order to check that the ETMA -
equipment functions correctly.

Test Alarm Call


No Step
1 In the car, trigger a test alarm call as follows:
In case of capacitive COP:
1) Press the alarm button (DAKI) five times within 10 seconds.
This preparatory step identifies the alarm call to TACC as "test alarm call from
a technician".
2) After the beep-beep sound, press the alarm button (DAKI) to trigger the actual
test alarm call.
For all other COPs:
1) Disable alarm filtering if necessary.
2) Release a normal alarm call.
If there is no response, refer to:
 EJ 604713 Diagnostics Telealarm Device TM2-TAM2 Rel. 3.3
 EJ 41700383 Diagnostics AC TMA 1 (ETMA PSTN).

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 5/9
3 Replacement

DANGER
Hazardous Voltage from the Phone Line (PSTN line)
Phone lines feature a ringing voltage of up to 150 VAC peak to peak. Contact with the live
parts of a phone circuit during ringing will result in electric shock causing serious injury or
death.
Exercise great care when working on equipment which is connected to a phone line.

Preparatory
Steps No Step
1 Put signs “Out of Service” in front of each landing door.
2 Make sure that during maintenance work the car is empty of persons and goods.
3 Switch on the hoistway lights.
4 Check for any roll back or out of level conditions.
5 Check if there are any vibrations or excessive jerk or noise during travel.
6 While riding in the car, check if any excessive noise has developed in the
machine room / hoistway head.
7 Check that all landing doors close and lock securely.
8 Record the number of trips from the trip counter in the installation record book.
9 Report any problems to the service department.

Replacement
1 Replace the ETMA device.
2 After the replacement, trigger a test alarm call in order to check that the ETMA
equipment functions correctly.
Refer to paragraph "Test Alarm Call" in chapter "Preventive Maintenance".

Waste Disposal
Pos Part Disposal Code
1 ETMA device (the complete unit) WEEE

Disposal Codes See J 630009 Waste Disposal Instructions for more details.

Code Component/Material Disposal Instruction Type of Disposal


WEEE Electrical and  Collect separately. Recycling/disposal by
electronic waste  Return to collecting station, authorized specialist
manufacturer or specialist. firm
Printed Circuit Boards disposer.  Recycling/disposal
(PCBAs)  Do not dispose of with by authorized
garbage. specialist firm
 Do not dispose of in landfill.  Recycling by LOC
free of charge. 1)
1) Return to: Schindler Electronics Ltd., CH-6600 Locarno, Switzerland
Indicate "Material for Disposal" on the packaging.

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 6/9
A1 * Spare Parts

Spare Parts
ID No. Image Description
59700884 ETMA kit Induction loop with UPS
Refer to J 41700744 instruction for
installation

[41700382_003; 16.12.2016]
59700474 ETMA-TRI
 Triphonie module
 Located on the car roof or underneath
the car
 Connected to ETMA-CAR-T via 8-wire
cable (not shielded) with
RJ48 connector
[35401; 20.05.2010]  Features:
– Push buttons ALARM and
INTERCOM
– LEDs POWER ON, LAGC and
LARC
– Microphone
– Speaker.
59700563 ETMA-CAR
 Slave ETMA module
 Interfaces to master module
ETMA-PSTN via ETMA-link
 Interfaces to COP:
– Alarm input
– Power to LEDs LAGC and LARC
– Microphone
[35398; 20.05.2010]
– Speaker.
 Form factor identical to TM2-TAM2.
59700564 ETMA-CAR-T
Same as ETMA-CAR but additionally:
 Interfaces to triphonie modules on the
car roof and underneath the car
 Interfaces to induction loop amplifier.

[35397; 20.05.2010]
59700570 ETMA-MR-PSTN-1
 Master module
 Interfaces to PSTN
 Interfaces to elevator controller via
RS232
 Interfaces to 1 slave module via
ETMA-link.
[35400; 20.05.2010]

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 7/9
ID No. Image Description
59700571 ETMA-MR-PSTN-1-I
Same as ETMA-PSTN-1 but additionally:
 Features intercom capability.

[35399; 20.05.2010]
59700572 ETMA-MR-PSTN-2-I
 Master module
 Interfaces to PSTN
 Interfaces to elevator controller via
RS232
 Interfaces to up to 2 slave modules via
ETMA-link.
 Features intercom capability
[36338; 03.08.2011]
59700569 ETMA-LND-FF
 Slave ETMA module
 Interfaces to master module
ETMA-PSTN via ETMA-link
 Interfaces to JBF
 Features intercom capability.
 Delivered with a premounted cable
(ID.No. 55520703).
[36339; 23.07.2010]
59712993 ETMA fire fighter intercom kit 03.00
Faceplate material: Stainless steel with
hairline finish

[41700382_002; 16.12.2016]
59700483 - PCBA CAR 11
Programmed for fixtures
59700484 PCBA CAR 12
Programmed for fixtures
59700485 PCBA CART 1
Programmed for fixtures

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 8/9
A2 Abbreviations

Abbreviations
Abbreviation Description
AMD Alarm misuse discrimination (alarm filtering)
CO Elevator controller
COP Car operating panel
DAKI, DAKA Alarm button in the car, alarm button outside the car
ETMA Embedded telemonitoring and alarming
FF Firefighter
JBF Firefighter key switch
LDU Landing door unit
MR Machine room (installation with machine room)
MRL Machine room less (installation without machine room)
NC Normally closed (contact)
PSTN Public switched telephone network
PTT Push-to-talk (button)
TACC Telealarm call center
UPS Uninterruptible power supply

AC TMA 1 (ETMA PSTN)


EJ 41700382 03
Maintenance
Copyright © 2017 INVENTIO AG 9/9

You might also like