EJ 41700382-03 AC TMA1 (ETMA PSTN) Maintenance
Summary This manual provides instructions for the maintenance of embedded telemonitoring and
alarming (ETMA PSTN) equipment and covers the ETMA PSTN releases 03.00 and later.
Page 1/9
Table of Contents
1 Safety Advice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.1 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Safety Warnings Used in this Manual . . . . . . . . . . . . . . . . . . 3
2 Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
A1 * Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
A2 Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
The following types of safety warnings are used in the present manual.
DANGER
The safety warning with the signal word “Danger” is used to indicate a hazardous situation
which, if not avoided, will result in death or serious injury.
Overview
E8 E3 E2
PSTN
ETMA TACC
ETMA-MR
CO
ETMA-LND-FF JBF
UPS
ETMA-CAR
COP
IL ETMA-TRI ETMA-TRI E1
Task List
Interval Description Refer to
Every Visit Trigger a test alarm call in order to check that the ETMA -
equipment functions correctly.
DANGER
Hazardous Voltage from the Phone Line (PSTN line)
Phone lines feature a ringing voltage of up to 150 VAC peak to peak. Contact with the live
parts of a phone circuit during ringing will result in electric shock causing serious injury or
death.
Exercise great care when working on equipment which is connected to a phone line.
Preparatory
Steps No Step
1 Put signs “Out of Service” in front of each landing door.
2 Make sure that during maintenance work the car is empty of persons and goods.
3 Switch on the hoistway lights.
4 Check for any roll back or out of level conditions.
5 Check if there are any vibrations or excessive jerk or noise during travel.
6 While riding in the car, check if any excessive noise has developed in the
machine room / hoistway head.
7 Check that all landing doors close and lock securely.
8 Record the number of trips from the trip counter in the installation record book.
9 Report any problems to the service department.
Replacement
1 Replace the ETMA device.
2 After the replacement, trigger a test alarm call in order to check that the ETMA
equipment functions correctly.
Refer to paragraph "Test Alarm Call" in chapter "Preventive Maintenance".
Waste Disposal
Pos Part Disposal Code
1 ETMA device (the complete unit) WEEE
Disposal Codes See J 630009 Waste Disposal Instructions for more details.
Spare Parts
ID No. Image Description
59700884 ETMA kit Induction loop with UPS
Refer to J 41700744 instruction for
installation
[41700382_003; 16.12.2016]
59700474 ETMA-TRI
Triphonie module
Located on the car roof or underneath
the car
Connected to ETMA-CAR-T via 8-wire
cable (not shielded) with
RJ48 connector
[35401; 20.05.2010] Features:
– Push buttons ALARM and
INTERCOM
– LEDs POWER ON, LAGC and
LARC
– Microphone
– Speaker.
59700563 ETMA-CAR
Slave ETMA module
Interfaces to master module
ETMA-PSTN via ETMA-link
Interfaces to COP:
– Alarm input
– Power to LEDs LAGC and LARC
– Microphone
[35398; 20.05.2010]
– Speaker.
Form factor identical to TM2-TAM2.
59700564 ETMA-CAR-T
Same as ETMA-CAR but additionally:
Interfaces to triphonie modules on the
car roof and underneath the car
Interfaces to induction loop amplifier.
[35397; 20.05.2010]
59700570 ETMA-MR-PSTN-1
Master module
Interfaces to PSTN
Interfaces to elevator controller via
RS232
Interfaces to 1 slave module via
ETMA-link.
[35400; 20.05.2010]
[35399; 20.05.2010]
59700572 ETMA-MR-PSTN-2-I
Master module
Interfaces to PSTN
Interfaces to elevator controller via
RS232
Interfaces to up to 2 slave modules via
ETMA-link.
Features intercom capability
[36338; 03.08.2011]
59700569 ETMA-LND-FF
Slave ETMA module
Interfaces to master module
ETMA-PSTN via ETMA-link
Interfaces to JBF
Features intercom capability.
Delivered with a premounted cable
(ID.No. 55520703).
[36339; 23.07.2010]
59712993 ETMA fire fighter intercom kit 03.00
Faceplate material: Stainless steel with
hairline finish
[41700382_002; 16.12.2016]
59700483 - PCBA CAR 11
Programmed for fixtures
59700484 PCBA CAR 12
Programmed for fixtures
59700485 PCBA CART 1
Programmed for fixtures
Abbreviations
Abbreviation Description
AMD Alarm misuse discrimination (alarm filtering)
CO Elevator controller
COP Car operating panel
DAKI, DAKA Alarm button in the car, alarm button outside the car
ETMA Embedded telemonitoring and alarming
FF Firefighter
JBF Firefighter key switch
LDU Landing door unit
MR Machine room (installation with machine room)
MRL Machine room less (installation without machine room)
NC Normally closed (contact)
PSTN Public switched telephone network
PTT Push-to-talk (button)
TACC Telealarm call center
UPS Uninterruptible power supply