Professional Documents
Culture Documents
Bone Level Implants: Product Catalog
Bone Level Implants: Product Catalog
2
INTRODUCTION P 4
SHORT IMPLANTS P 47
BABY M AND BABY 8 IMPLANTS P 48
3
AN IMPLANT SOLUTION...
The choice of implant technique, specific to each user,
must match the clinical situation requiring treatment.
1 2 M 8
This is why TBR provides different implant ranges that not only
facilitate the daily practice of implantology, but also -
and above all - satisfy the periodontal requirements.
4
... FOR EVERY PATIENT.
1 STAGE IMPLANTS - SOFT TISSUE LEVEL
The Zirconia Y-TZP collar technology has proven to be a real aesthetic anti-bacterial shield.
BABY IMPLANTS
5
A PROSTHETIC SOLUTION...
1st step of the implant treatment, the design of the prosthetic project will provide the
specifications for the implant rehabilitation.
The aim is to restore a function and obtain an aesthetic result compatible with the
patient’s expectations.
Whatever your choice, whatever the case to be treated, TBR offers a fully comprehensive
range of prosthetic components.
6
...FOR EVERY PATIENT.
Unit Plural Total
Cemented
Removable
7
SOME GUIDELINES...
Make surgery and prostheses easier!
TBR implant and prosthetic systems have a multitude of benefits and tools to simplify your daily practice.
Drilling sequence Ø 5 mm
L. 10.5 mm
8
... FOR BETTER ORIENTATION.
Packaging and text
Each product is checked and packaged individually, in an ultra-clean environment.
You and all TBR users expect your manufacturer to provide a product with
guaranteed origin and quality. All our products, sterile or non-sterile, carry
the CE mark and therefore meet the regulatory requirements associated
with all medical devices.
Ø4.7 Implant
L11.5 mm PACKAGING FOR STERILE IMPLANTS
Z1- Ø3.9
L11.5 Hc 1.5 mm
Ø4.7
L11.5 mm
M511 Double sterile blister with tube and cover/closing Dental implant
ZM411screw 15/9999 Ø4.7
L11.5 mm
Z1- Ø3.9
Ø4.7
L11.5
L11.5mm
Hc 1.5 mm
Z1- Ø3.9
Ø4.7
L11.5
L11.5 Hc 1.5 mm
mm
Tube holder
M511 M511
ZM411 15/9999 ZM411 15/99
Cover screw
2020.01.01 2020.01.01
0459 0459
its container to get a grip on All implants are packaged with Ø4.7 Hc 1.5 mm
L11.5
L11.5 mm
Z1- Ø3.9
Ø4.7
L11.5
L11.5
Hc 1.5 mm
L11.5mm
Hc 1.5 mm
Z1- Ø3.9
Ø4.7
L11.5
L11.5
L11.5
Hc 1.5 mm
Hc 1.5 mm
mm
Prosthesis
PACKAGING FOR NON-STERILE PROSTHETIC COMPONENTS
Individual sachet with 3 detachable and repositionable labels
Rev. 2019/03
M-MT410
M-MT410
*+ESUDMT4101/$20I9999
manufacture
/16D20200203M*
2020-02-03
Manufacturer
Contents must be sterilized prior to use (134°C-18min)
M-MT410
Specifications 20-30N.cm-Qty:1
*+ESUDMT4101/$20I9999
/16D20200203M* contact details
-- Platform Ø Storage conditions
-- Connection type EN Titanium screw-retained abutment + long screw
-- Quantity
PT Pilar titânio con parafuso longo protocol available at
PL Łącznik tytanowy przykręcany + długa śruba
TR Titanyum vida muhafaza dayanak + uzun vida
http://ifu.tbr.dental
MD 鈦螺絲固基台+長螺旋
Product name
9 languages
9
10
Implant systems with
8 Connection
F l a t f r ic tion &
Internal octagon
8 2
11
infinity
SWISSCLIP TECHNOLOGY
Clipping system between the implant and the screw
tools for contra-angle or for torque wrench
Gripping and direct positioning of the implant with-
out digital contact
Real time-saving and high accuracy
Available for direct technique transfers and for the
angulation kit
MATERIALS
Grade 4 Titanium: T60 commercially pure
Grade 4 T60 commercially pure titanium meets the
requirements of ISO 5832-2 and the American Society
for Testing and Materials (ASTM F67 3.7065)
12
2 2 STAGE IMPLANTS - BONE LEVEL
The perfect implant/abutment fit with Platform Switching
releases a new biological space for better tissue stability.
PLATFORM SWITCHING
Gingival ring-shaped sleeve around the implant
Absolute imperviousness to bacterial attacks
Reduction of micro-movements and
inflammatory infiltration on the peri-implant
crestal bone
Long-lasting aesthetics, bone tissue stability
and soft tissue preservation
CCS BIOSHAPE
Conical cruciform apex with a wide thread
diameter
Cylindrical body to maintain close bone contact
Spherical collar with a bevelled top to limit
bone stress and preserve the crestal bone
Optimal primary stability and insertion safety
SURFACE TREATMENT
The implants incorporate a sandblasting
and hydrofluoric acid-etching
surface treatment that promotes the
osseointegration process.
00
SEM x25
SEM x500
0
ATRAUMATIC APEX
Apex with atraumatic convexity
Ideal for sinus lifts
Self-tapping claw
13
Connect
CC BIOSHAPE
Self-tapping conical cruciform apex
Cylindrical body to maintain close bone contact
Optimal primary stability and insertion safety
SWISSCLIP TECHNOLOGY
Clipping system between the implant and the
screw tools for contra-angle or for torque wrench
Gripping and direct positioning of the implant
without digital contact
Real time-saving and high accuracy
Available for direct technique transfers and for
the angulation kit
MATERIALS
Grade 4 Titanium: T60 commercially pure
Grade 4 T60 commercially pure titanium meets the
requirements of ISO 5832-2 and the American Society for
Testing and Materials (ASTM F67 3.7065)
14
2 2 STAGE IMPLANTS - BONE LEVEL
The perfect implant/abutment fit with Platform Switching
releases a new biological space for better tissue stability.
PLATFORM SWITCHING
Gingival ring-shaped sleeve around the implant
Absolute imperviousness to bacterial attacks
Reduction of micro-movements and
inflammatory infiltration on the peri-implant
crestal bone
Long-lasting aesthetics, bone tissue stability
and soft tissue preservation
MICROTHREADED COLLAR
Limits the effects of micro-movements
Drastically reduces inflammatory infiltration
on the peri-implant crestal bone, and
preserves the vertical integrity of the bone
ridge
Improved vascularisation of the area, thus
protecting the peri-implant periodontal tissue
SURFACE TREATMENT
The implants incorporate a sandblasting
and hydrofluoric acid-etching
surface treatment that promotes the
osseointegration process.
00
SEM x25
SEM x500
0
ATRAUMATIC APEX
Apex with atraumatic convexity
Ideal for sinus lifts
Self-tapping claw
15
IMPLANT SURGERY & MANAGEMENT
OF GINGIVAL TISSUES
15.5 mm
I313
I315
I413
I415
I513
I515
• Ø3.5 • Ø4 • Ø5
15.5 mm
X313
X315
X413
X415
X513
X515
• Ø3.5 • Ø4 • Ø5
16
infinity
Connect 2
Baby 8
Cover screw
Ø Øem Product
Hg (mm) Preview Technical pattern Manual
implant (mm) code Øem screwing
Øem: Emergence diameter
Ø3.5 Ø3.5 O-VIO350 Hg
17
COMPONENTS FOR THE IMPRESSION-
TAKING AND MASTER CAST-MAKING
Impression Transfer - Direct Technique “Pick-up”
Ø Øem Hr Hc Product Platform switching
Profile Preview
implant (mm) (mm) (mm) code Technical pattern Manual
L=21.1 screwing
Standard O-TD300 Hc
Øem Hc: Cylindrical height Delivered with a
Ø3.5 Ø4.25
PS O-TDS300 Øem: Emergence diameter screw Ref. VTD185
Hr Hr: Radial height
Standard O-TD400 PS: Platform switching
Ø4 Ø5 2 2 Standard
PS O-TDS400
Indication
Hc
• • •
Standard O-TD500 Øem
Ø5 Ø6 Colour code Ø3.5 Ø4 Ø5
PS O-TDS500
Hr
• • •
Standard O-TI500 Øem
Ø5 Ø6 Colour code Ø3.5 Ø4 Ø5
PS O-TIS500 Hr
• • •
Ø5 Ø6 TDP500
Colour code Ø3.5 Ø4 Ø5
18
Colour code • Ø3.5 • Ø4 • Ø5
infinity
Connect 2
Baby 8
Tips for use For multi-unit abutment restorations, use the PEEK
scanbodies sheaths provided for this purpose (P27).
Implant analogue
Ø Ø implant
Product code Preview Technical pattern
implant
Ø implant: Implant platform diameter
Ø3.5 O-RL300
Ø4 O-RL400 Indication
Ø4 1 HPS400 Indication
Ø5 HPS500
Colour code • Ø3.5 • Ø4 • Ø5
Ø3.5 HLOC400
Ø3.5
Ø4 (8530) TDLOC100
Ø4
(8505)
Ø5
Ø5 HLOC500 (8516)
19
Standard prosthetic solutions
Cemented Screw-retained
prosthesis prosthesis
Secondary
elements
20
8 GENERAL PROSTHETIC SYNOPSIS
Removable
prosthesis
Spherical attachment +
Cap or O-ring
P. 28
infinity
Connect
Secondary
Baby 8
elements
Straight or angulated
multi-unit abutment +
Castable sheath P. 27
COMPONENT THAT
SINGLE-
UNIT FIXED
FULL-ARCH
FIXED 2 2 STAGE IMPLANT
BONE LEVEL
CAN BE USED BY
YOUR CAD / CAM
RESTORATION RESTORATION
SYSTEM
MULTIPLE-
REMOVABLE REFER TO THE RECOMMENDED
UNIT FIXED
RESTORATION SPECIFIED PAGES TIGHTENING TORQUE
RESTORATION
2
The final prosthetic components are gradually being delivered with 2 screws:
- 1 laboratory screw,
- 1 final screw.
21
FIXED CEMENTED PROSTHESIS
SOLUTIONS
0° O-MP300
Ø3.5 Ø4.25 α° Technical pattern Screwing
30 N.cm
15° O-MP301
Hg: Gingival height Delivered with a screw
L=7.3
0° O-MP400 Øem: Emergence diameter Ref. VIM052
Ø4 Ø5 2 α°: Angulation
Hg Øem
15° O-MP401
Indication
0° O-MP500
Ø5 Ø6
15° O-MP501
Ø4 Ø4 O-MC400 Øem
Ø5 Ø5 O-MC500 Indication
Ø4 Ø4 O-MCR400
Øem
Ø5 Ø5 O-MCR500 Indication
22
infinity
Connect 2
Baby 8
CEREC®-compatible Ti-base
(*) Shoulder
(1) These references require “S” blocks, unlike the others which use “L” blocks.
23
FIXED CEMENTED PROSTHESIS
SOLUTIONS
Ø Øem Product
α°
implant (mm)
α° Hg (mm)
code
Preview
0 O-MT300
L=7.3
0° 2 O-MT320
4 O-MT340 Øem
Hg
0 O-MT301 Ø implant
Ø3.5 Ø4.25 15° 2 O-MT321
Standard emergence profile
4 O-MT341
0 O-MT302
Technical pattern Screwing
25° 2 O-MT322 30 N.cm
Hg: Gingival height Delivered with
4 O-MT342 Øem: Emergence diameter 2 screws
α°: Angulation Ref. VIM052
0 ZC-MT000
0° 2 O-MT420 Indication
4 O-MT440
0 ZC-MT001
Ø4 Ø5 15° 2 O-MT421
4 O-MT441
0 ZC-MT002
25° 2 O-MT422
4 O-MT442
0 O-MT500
0° 2 O-MT520
4 O-MT540
0 O-MT501
Ø5 Ø6 15° 2 O-MT521
4 O-MT541
0 O-MT502
25° 2 O-MT522
4 O-MT542
24
infinity
Connect 2
Baby 8
Ø Øem Product
α°
implant (mm)
α° Hg (mm)
code
Preview
1 O-MTS310
0° L=7.3
2 O-MTS320
Øem
Hg
1 O-MTS311
Ø3.25
Ø4.25 15°
2 O-MTS321 Platform switching emergence profile
1 O-MTS312
25° Technical pattern Screwing
30 N.cm
2 O-MTS322
Ø3.5 Hg: Gingival height Delivered with
Ø4 Øem: Emergence diameter 2 screws
Ø5 α°: Angulation Ref. VIM052
1 O-MTS410
0°
2 O-MTS420
Indication
1 O-MTS411
Ø5 15°
2 O-MTS421
1 O-MTS412
25°
2 O-MTS422
25
FIXED SCREW-RETAINED
PROSTHESIS SOLUTIONS
Colour code
Ø5 Ø6 HO-CP500
• Ø3.2 • Ø3.9 • Ø4.7
26
infinity
Connect 2
Baby 8
3 O-PCS530
Tips
for use Taking impressions for angulated multi-unit abutments Ø3.5 / Ø4 / Ø5 is
done using transfer Ref. TDP400 for direct technique or Ref. TIP400 for indirect technique. Indication
The model will be cast with an analogue Ref. HP400.
27
STABILISATION OF REMOVABLE
PROSTHESIS SOLUTIONS
Spherical attachment
Ø H1 Hg Product
Type Preview
implant (mm) (mm) code
5 1.5 + cap O-ASC350
Ø2.7 Technical pattern Screwing
6.5 3 + cap O-ASC360 H1 20 N.cm
Ø3.5
5 1.5 + O-ring O-ASO350 Øem: Emergence diameter Delivered with:
6.5 3 + O-ring O-ASO360 H1: Collar height - one titani-
Hg um cap Ref.
5 1.5 + cap O-ASC450 ASC100
Øem Indication
6.5 3 + cap O-ASC460 and spacer
Ø4 Ø4 rings
5 1.5 + O-ring O-ASO450 Ø 5.2 Ref. PRO100
6.5 3 + O-ring O-ASO460 or
5 1.5 + cap O-ASC550 H=4
H=2 - one O-ring
6.5 3 + cap O-ASC560 Ref. ASO200
Ø5
5 1.5 + O-ring O-ASO550
6.5 3 + O-ring O-ASO560
28
infinity
Connect 2
Baby 8
Titanium cap - O-ring Ref.ASO200 is used when the implant axis is straight
ASC100 H=4
+ spacer rings and the occlusal height is reduced.
Ø2.3 Ø3.3 - Cap Ref.ASC100 is used when the implant axis needs to be
Spacer rings PRO100
corrected.
H=1.5 H=2
Ø 5.2 - The spacer rings Ref. PRO100 can be resized.
O-ring ASO200
- The O-ring retention joints Ref.ASJ200 should be changed
Silicon joint H=2 every year.
ASJ200
for O-ring (x5)
STANDARD retention joint ASJEQU400 EXTRA LIGHT nylon 20° Div max ASJLOC400
1.6 kg
(x4) clear (140CET) retention joint (x4) blue / 0.68 kg (8529)
Equator® multi-function A-CEQU100 STANDARD nylon reten- 20° Div Max / ASJLOC600
N/A
core tool (485IC) tion joint (x4) clear 2.27 kg
(8524)
29
30
Implant systems with
M Connection
Morse taper &
hexagonal indexing
M 2
31
M
SWISSCLIP TECHNOLOGY
Clipping system between the implant and the
screw tools for contra-angle or for torque wrench
Gripping and direct positioning of the implant
without digital contact
Real time-saving and high accuracy
Available for direct technique transfers and for
the angulation kit
MATERIALS
Grade 4 Titanium: T60 commercially pure
Grade 4 T60 commercially pure titanium meets the
requirements of ISO 5832-2 and the American Society for
Testing and Materials (ASTM F67 3.7065)
32
2 2 STAGE IMPLANTS - BONE LEVEL
The perfect implant/abutment fit with Platform Switching
releases a new biological space for better tissue stability.
PLATFORM SWITCHING
Gingival ring-shaped sleeve around the
implant
Absolute imperviousness to bacterial attacks
Reduction of micro-movements and
inflammatory infiltration on the peri-implant
crestal bone
Long-lasting aesthetics, bone tissue stability
and soft tissue preservation
CCS BIOSHAPE
Conical cruciform apex with a wide thread
diameter
Cylindrical body to maintain close bone contact
Spherical collar with a bevelled top to limit bone
stress and preserve the crestal bone
Optimal primary stability and insertion safety
SURFACE TREATMENT
The implants incorporate a sandblasting
and hydrofluoric acid-etching
surface treatment that promotes the
osseointegration process.
00
SEM x25
SEM x500
0
ATRAUMATIC APEX
Apex with atraumatic convexity
Ideal for sinus lifts
Self-tapping claw
33
IMPLANT SURGERY
& MANAGEMENT OF GINGIVAL TISSUES
15 mm
M313
M315
M413
M415
M513
M515
• Ø3.2 • Ø3.9 • Ø4.7
Cover screw
Ø Øem Product
Hg (mm) Preview
implant (mm) code
Colour code
• • •
Ø3.9 Ø3.1 0.3 M-VIO400
Ø3.2 Ø3.9 Ø4.7
34
M 2
Baby M
Ø Øem Product
Hg (mm) Preview
implant (mm) code
3.5 M-VT330
Ø4.55 5 M-VT350 Øem Technical pattern Manual
Ø3.2 7 M-VT370 Øem: Emergence diameter screwing
3.5 M-VTL330 Hg: Gingival height
Ø6 Hg
5 M-VTL350
Colour code
Ø5.3
3.5
5
M-VT430
M-VT450 • Ø3.2 • Ø3.9 • Ø4.7
Ø3.9 7 M-VT470
3.5 M-VTL430
Ø6.3
5 M-VTL450
Tips for use
3.5 M-VT530
Ø6.3 5 M-VT550 The wide healing screw is useful in the case
Ø4.7 7 M-VT570 of a gingival preparation for receiving a large
crown (e.g. posterior sector) and to facilitate
3.5 M-VTL530 the installation of the impression transfer.
Ø7.3
5 M-VTL550
35
COMPONENTS FOR THE IMPRESSION-
TAKING AND MASTER CAST-MAKING
Impression Transfer - Direct Technique “Pick-up”
Ø Øem Hr Hc Product Technical pattern Manual
Preview L=20.6 screwing
implant (mm) (mm) (mm) code
Hc: Cylindrical height Delivered with a screw
Ø3.2 1.5 M-TDS300 Øem: Emergence diameter Ref. VTD186
Hc Hr: Radial height
Ø3.2 1.5 M-TD300 Øem
Ø4.25
2.5 M-TD350 Indication
Hr
• • •
1.5 2.5 M-TD400
Ø3.9 Ø5 Colour code Ø3.2 Ø3.9 Ø4.7
2.5 M-TD450
1.5 M-TD500 M-TDS300 for an M-MTS310 / 311 / 312
Ø4.7 Ø6 Tips for use abutment. M-TD350 / 450 / 550 for
2.5 M-TD550 abutments with 3 and 5 mm shoulder.
• • •
2.5 M-TI450
Colour code Ø3.2 Ø3.9 Ø4.7
1.5 M-TI500
Ø4.7 Ø6
2.5 M-TI550 Tips for use M-TI350 / 450 / 550 for abutments with
3 and 5 mm shoulder.
• • •
Ø4.7 Ø6 TDP500
Colour code Ø3.2 Ø3.9 Ø4.7
36
Colour code • Ø3.2 • Ø3.9 • Ø4.7
M 2
Baby M
Implant analogue
Ø Ø implant
Product code Preview Technical pattern
implant
Ø implant: Implant platform diameter
Ø3.2 M-RL300
Ø3.5 HLOC400
Ø3.5
Ø4 (8530) TDLOC100
Ø4
(8505)
Ø5
Ø5 HLOC500 (8516)
37
Standard prosthetic solutions
Cemented Screw-retained
prosthesis prosthesis
Secondary
elements
38
M GENERAL PROSTHETIC SYNOPSIS
Removable
prosthesis
Spherical attachment
+ Cap or O-ring
P. 44
M
Secondary
elements
Baby M
Retention, accessories Equator® abutment
and instrumentation
P. 44
Straight or angulated
multi-unit abutment
+ Castable sheath P. 42
COMPONENT THAT
SINGLE-
UNIT FIXED
FULL-ARCH
FIXED 2 2 STAGE IMPLANT
BONE LEVEL
CAN BE USED BY
YOUR CAD / CAM
RESTORATION RESTORATION
SYSTEM
MULTIPLE-
REMOVABLE REFER TO THE RECOMMENDED
UNIT FIXED
RESTORATION SPECIFIED PAGES TIGHTENING TORQUE
RESTORATION
2
The final prosthetic components are gradually being delivered with 2 screws:
- 1 laboratory screw,
- 1 final screw.
39
FIXED CEMENTED PROSTHESIS
SOLUTIONS
Narrow titanium final abutment
α°
Ø Øem Hg Product Technical pattern Screwing
implant (mm)
α° (mm) code
Preview 30 N.cm
L=7.9
Hg: Gingival height Delivered with
0° M-MTS310 Øem: Emergence diameter 2 screws Ref. VIM064
α°: Angulation
Ø3.2 Ø3.2 15° 1.5 M-MTS311 Hg Øem
Indication
25° M-MTS312
Tips for use Narrow abutments Ref. M-MTS 310 / 311 / 312 are indicated in the case of reduced interdental space [e.g. central mandibular incisors]
0° M-MP500
Ø4.7 Ø6
15° M-MP501
40
M 2
Baby M
CEREC®-compatible Ti-base
Ø Gingival height (mm) Ø Ø
Im- Block S Block L Preview
0.7 1.5 Shldr*S Shldr*L
plant
M-TBSS307 (1)
M-TBSS310 (1) FX 3.4 S Ø3.9 N/A N/A Emergence
Ø3.2 Ø4.4 mm
AT OS BLOCK S
M-TBS307 M-TBS310 N/A N/A Ø4.4
3.5/4.0 BLOCK L
AT OS
Ø3.9 M-TBS407 M-TBS410 N/A N/A Ø4.4
3.5/4.0
AT OS Emergence Emergence Emergence
Ø4.7 M-TBS507 M-TBS510 N/A N/A Ø5.0 Ø4.4 mm Ø4.4 mm Ø5 mm
4.5/5.0
L=6.6
Technical pattern Screwing
Tips for use 30 N.cm
Hg Hg: Gingival height Delivered with
The CEREC®-compatible Ti-bases are used with SIRONA® scanbodies: Øem
Øem: Emergence diameter 2 screws Ref. VIM051
if Hg = 0.7 mm
Product code for Omnicam Product code for Bluecam or
6431311 block S 6431295 block S L=7.9
Special CAD / CAM Ref. VIM064
6431329 block L 6431303 block L if Hg = 1.5 mm
Indication
(*) Shoulder
(1) These references require “S” blocks, unlike the others which use “L” blocks.
41
FIXED SCREW-RETAINED
PROSTHESIS SOLUTIONS
Colour code
Ø5 Ø6 HO-CP500
• Ø3.2 • Ø3.9 • Ø4.7
42
M 2
Baby M
3 M-PCS530
Tips
for use Taking impressions for Angulated Multi-Unit Abutments Ø3.2 / Ø3.9 /
Ø4.7 is done using transfer Ref. TDP400 for direct technique or Ref. TIP400 for indirect Indication
technique.The model will be cast with an analogue Ref. HP400.
43
STABILISATION OF REMOVABLE
PROSTHESIS SOLUTIONS
Spherical attachment
Ø Hg Product Technical pattern Screwing
Type Preview L=3.4 Ø2.7 20 N.cm
implant (mm) code
Øem: Emergence diameter Delivered with:
+ cap M-ASC350 Hg: Gingival height - one titanium
Ø3.2 cap Ref. ASC100
+ O-ring M-ASO350 and spacer rings
+ cap M-ASC450 Indication Ref. PRO100
or
Ø3.9 1.5 Hg
+ O-ring M-ASO450 Ø4 - one O-ring
Ø 5.2 Ref. ASO200
+ cap M-ASC550
Ø4.7 H=4
+ O-ring M-ASO550 H=2
44
M 2
Baby M
Titanium cap - O-ring Ref.ASO200 is used when the implant axis is straight
ASC100 H=4
+ spacer rings and the occlusal height is reduced.
Ø2.3 Ø3.3 - Cap Ref.ASC100 is used when the implant axis needs to be
Spacer rings PRO100
corrected.
H=1.5 H=2
Ø 5.2 - The spacer rings Ref. PRO100 can be resized.
O-ring ASO200
- The O-ring retention joints Ref.ASJ200 should be changed
Silicon joint H=2 every year.
ASJ200
for O-ring (x5)
STANDARD retention joint ASJEQU400 EXTRA LIGHT nylon 20° Div max ASJLOC400
1.6 kg
(x4) clear (140CET) retention joint (x4) blue / 0.68 kg (8529)
Equator® multi-function A-CEQU100 STANDARD nylon reten- 20° Div Max / ASJLOC600
N/A
core tool (485IC) tion joint (x4) clear 2.27 kg
(8524)
45
46
B a b y
Implant Systems
adapted to
sp ec if ic a na tomica l
requirements
2 M 8
47
Baby-M
M 2
6 MM SHORT IMPLANTS - MORSE TAPER CONNECTION
Baby M implants with a Morse taper connection combine the benefits of the Platform
Switching technique with a reduced height of 6 mm.
CYLINDRICAL BIOSHAPE
Cylindrical body to maintain close bone
contact
Slightly conical atraumatic cruciform apex
with a wide thread diameter
Optimal primary stability and insertion safety
MATERIALS
Grade 4 Titanium: T60 commercially pure
Grade 4 T60 commercially pure titanium meets the
requirements of ISO 5832-2 and the American Society for
Testing and Materials (ASTM F67 3.7065)
48
Baby 8
8 2 6 MM SHORT IMPLANTS - OCTAGONAL CONNECTION
The use of Baby 8 implants with an octagonal connection offers the advantages of reducing
the number of surgical procedures and respecting the integrity of the periodontium.
PLATFORM SWITCHING
Gingival ring-shaped sleeve around the
implant
Absolute imperviousness to bacterial attacks
Reduction of micro-movements and
inflammatory infiltration on the peri-implant
crestal bone
Long-lasting aesthetics, bone tissue stability
and soft tissue preservation
SURFACE TREATMENT
The implants incorporate a sand-
blasting and hydrofluoric acid-etching
surface treatment that promotes the
osseointegration process.
0
SEM x250
SEM x500
0
ATRAUMATIC APEX
Apex with atraumatic convexity
Ideal for sinus lifts
Self-tapping claw
49
50
Instrumentation
& Accessories
8 Connection / M Connection
2 M 8
51
INSTRUMENTATION
& ACCESSORIES
Surgical kit
All the essential elements for your implant surgery practice are
gathered in the surgical kit depending on the system you have
chosen: M, 8 or infinity.
Ergonomic
A compact and complete kit design.
Easy-to-use
Components available in different sizes to suit
all clinical cases.
Safety
Easy to clean and steam sterilisable.
11 Torque wrench
8 Short and
Dual function long screw tools
for contra-angle
7
Torque 10
wrench position 10 Location
(10 to 45 N.cm) to stabilise the
internal blister
15
Radel® box
11 Short and
Sterilisable
14 13 12 11
long hexagonal
134°/18 min
screwdrivers
Safety
Easy to clean and steam sterilisable.
2 Choice of
2
1 Laser implant length
marking of the
implant range
1
3 Drill No. 2
intermediate
3
6 Sequence
of removable 6 4 Drilling
stops to use 4 sequence
according to the
diameter of the
5 Surgical 5 implant to be
stainless fitted
steel box
Sterilisable M
Ref. A-TF004
8
Ref. A-TF003
8
Ref. A-TF005
134°/18 min M implants 8 implants infinity implants
I-
Pack of removable stops for drill No. 2 - 8 A-PCB200
Pack of removable stops for drill No. 3 - 8 A-PCB300
Pack of removable stops for drill No. 4 - 8 A-PCB400
Pack of removable stops for drill No. 5 - 8 A-PCB500
Pack of removable stops for drill No. 2 - M A-PMB200
Pack of removable stops for drill No. 3 - M A-PMB300
Pack of removable stops for drill No. 4 - M A-PMB400
Pack of removable stops for drill No. 5 - M A-PMB500
53
INSTRUMENTATION
& ACCESSORIES
Surgical instrumentation
Surgical instrumentation
M
Ø3.2 Ø3.9 Ø4.7
M / BABY M IMPLANTS
8
Ø3.5 Ø4.0 Ø5.0
A-TS600
8.0 6.0 6.0
6.0 8.0 8.0 8.0
M
Ø 4.4 / H 1.5 Ø 5.0 / H 1.5 Ø 6.0 / H 1.5
Ø3.2 Ø3.9 Ø4.7
15.0
13.0
8.0 8.0 8.0
11.5 10.0 10.0 10.0
10.0 11.5 11.5 11.5
13.0 13.0 13.0
8.0 15.0 15.0 15.0
6.0
IMPLANTS
8
Ø 5.0 / HC 1.5 Ø 5.0 / HC 1.5 Ø 6.0 / HC 1.5
Ø3.5 Ø4.0 Ø5.0
55
INSTRUMENTATION
& ACCESSORIES
Prosthetic kit
All the essential elements for your practice of implant-supported
prosthesis are gathered in the M and 8 prosthetic kits.
Ergonomic
New design for a compact and complete kit.
Easy-to-use
Components available in different sizes to suit all clinical cases.
Safety
Easy to clean and steam sterilisable.
1 8
Ratchet
wrench position 9 Short tip for torque
(symbol ∞)
wrench
M For M abutment:
14 Angulation kit 13 Shoulder height selector 11 Short abutment extractor
For M abutment with shoulder < or = 0.7 mm
α° H
4 12 Long abutment extractor
3 For Z1-M and M abutment with shoulder > or = 1.5 mm
1.5
Maintenance
56
infinity
Connect 2 M 2
Baby 8 Baby M
Main screws sold per unit and tightening torque
Product name Range Product code Preview Maintenance
1 helical extractor drill
Screw extraction kit 1 reverse claw extractor M A-KEV600
For any other
Range 8 - 4 elements 1 screw extractor guide
1 universal screw tool adaptor 8 A-KEV800 screw product
code request,
Product name Range Tightening torque Product code Preview please contact us.
Prosthetic instrumentation
Product name Kit M Kit 8 Product code Preview
✓ Aesthetic solutions* :
Lumineers® thin veneers
✓ Implant solutions :
BL implants systems
Z1® implant systems
✓ Equipment solutions* :
NSK® Surgical Motor [MD Class IIa - Manufacturer Nakanishi Inc.]
Perioptix® Optical Systems [MD Class I and custom-made - Manufacturer Denmat LLC]
SleeperOne® Electronic Anaesthetic Injection [MD Class IIa - Manufacturer Dental HiTec SARL]
Sapphire® Curing Light [MD Class IIa - Manufacturer DenMat LLC.]
Carestream® Imaging Solutions [MD Class I & IIa - Manufacturer Carestream Health Inc.]
NV PRO3® Laser [DM de classe IIb - Manufacturer DenMat LLC.]
* Availability according to country.
58
The TBR® team
Unique, like your smile.
30
A multidisciplinary manufacturer
TBR is an international company with headquarters based
years
✓ Aesthetic solutions
Quality
✓ Implant solutions
✓ Equipment solutions
Made in
We aim to become an irreplaceable partner for dental
professionals around the world. We share the same
ambitions - to offer patients the best possible functional and
aesthetic restorations - and are here to support your services
France
with high quality products.
Authentic products
International We aim to help you meet patient expectations with our
Presence
authentic products and technologies. We are also keen to
help you communicate to patients in order to grow your
practice.
Find us online
www.tbr.dental
The products mentioned in this document are medical devices intended for aesthetic or
functional smile rehabilitation, by authorized health professionals. These medical devices
are regulated health products that, under this regulation, bear the CE marking. Read the
instructions carefully before using the products. All the essential information for correct use of
these devices is available from SUDIMPLANT SAS (TBR Group).