This document outlines the electrical specifications and requirements for a project. It specifies that all electrical work must comply with the Philippine Electrical Code and local regulations. The electrical service will be 1-phase, 2-wire, 230V AC power. Approved wiring methods include intermediate metallic conduit for feeders and risers, and PVC conduit for lighting and receptacles. Wires must be copper and thermoplastic insulated for a minimum size of 3.5mm2. Grounding must be provided per code. Mounting heights are specified for various devices.
This document outlines the electrical specifications and requirements for a project. It specifies that all electrical work must comply with the Philippine Electrical Code and local regulations. The electrical service will be 1-phase, 2-wire, 230V AC power. Approved wiring methods include intermediate metallic conduit for feeders and risers, and PVC conduit for lighting and receptacles. Wires must be copper and thermoplastic insulated for a minimum size of 3.5mm2. Grounding must be provided per code. Mounting heights are specified for various devices.
This document outlines the electrical specifications and requirements for a project. It specifies that all electrical work must comply with the Philippine Electrical Code and local regulations. The electrical service will be 1-phase, 2-wire, 230V AC power. Approved wiring methods include intermediate metallic conduit for feeders and risers, and PVC conduit for lighting and receptacles. Wires must be copper and thermoplastic insulated for a minimum size of 3.5mm2. Grounding must be provided per code. Mounting heights are specified for various devices.
ALL ELECTRICAL WORKS SHALL COMPLY IN ACCORDANCE WITH THESE PLANS
AND SPECIFICATIONS. THE APPLICABLE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE (PEC). THE RULES AND REGULATION OF THE LOCAL ENFORCING AUTHORITY AND THE REQUIREMENTS OF THE LOCAL POWER COMPANY. THE ELECTRICAL WORKS SHALL BE UNDER IMMEDIATE SUPERVISION OF A DULY REGISTERED ELECTRICAL ENGINEER. 2. THE ELECTRICAL SERVICE POWER IS 1-PHASE, 2-WIRE, 230V AC, 60Hz. 3. WIRING METHOD SHALL BE AS FOLLOWS: a. FEEDERS AND RISERS - INTERMEDIATE METALLIC CONDUIT b. LIGHTING, POWER RECEPTACLE - POLYVINYL CHLORIDE CONDUIT BRANCH CIRCUIT., & AUXILIARY SCH. 40 4. ALL WIRES SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THW" UNLESS OTHERWISE INDICATED IN THE PLAN. THE MINIMUM SIZE OF WIRE FOR POWER AND LIGHTING CIRCUIT HOMERUN SHALL BE 3.5sq.mm. AND INSULATED FOR 600 VOLTS. SMALLEST RACEWAY SHALL BE 15mm diameter TRADE/NOMINAL SIZE. A COMPUTATION OF LOADS 5. ALL OUTLET BOXES SHALL BE GALVANIZED GAGE NO. 16 DEEP TYPE WITH E1 SCALE NTS FACTORY KNOCKOUTS. 6. ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND APPROVED TYPE FOR THE PARTICULAR LOCATION AND PURPOSE OF USAGE. 7. GROUNDING SYSTEM SHALL BE PROVIDED TO ALL LIGHTING AND POWER CIRCUIT AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT. 8. MOUNTING HEIGHT OF WIRING DEVICES SHALL BE AS FOLLOWS: a. LIGHT SWITCH - 1.20m ABOVE FINISH FLOOR b. CONVENIENCE OUTLET - 0.30m ABOVE FINISH FLOOR c. CONVENIENCE OUTLET (T&B) - 1.10m ABOVE FINISH FLOOR d. CONVENIENCE OUTLET (KITCHEN) - 0.40m ABOVE KITCHEN COUNTER e. PANELBOARD - 1.80m ABOVE FINISH FLOOR
FLOOR PLAN
B RISER DIAGRAM C GROUND FLOOR PLAN
E1 SCALE NTS SCALE NTS E1
SHTNo.
NAME ENGR. RACHELLE ANNE L. FERRAN ELECTRICAL PLAN E