Turbo Engineering Services: Quality Plan Customer Description Inspection Agency Witness Signature/approval Remarks

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

Turbo Engineering Services

An ISO 9001, ISO 14001 & BS OHSAS 18001 Certified Company


Plot No. 17/B, Phase- IV, I.P., Pashamylaram, Sangareddy Dist,
Hyderabad - 502307, Telangana, India.

QUALITY PLAN

CUSTOMER : M/S.

DESCRIPTION : Repair & Reconditioning of 135MW Turbine Rotor.

Inspection Witness
S. No Description Ref. Doc Remarks
Agency signature/Approval
1 Cleaning of turbine rotor ---- TES ---- --
2 Dismantling of damaged R1 & R2 blades As per drawing TES ----
Dismantling of damaged sealing fins on front and
3 As per drawing TES -----
rear steam gland and BP gland area
NDT checks on R1 & R2 blade grooves and ASTM -709
4 TES TES
remaining shaft area standard
Chemical & Mechanical testing of R1 & R2 blade Review of Test
5 Lab. certificate TES
material and sealing fin material certificates by customer
Review of Test
6 Ultrasonic testing on new blades raw material ASTM A-388 TES
certificates by customer
7 Dimensional Inspection of New blades As per drawing TES Customer
Dimensional Inspection of new blades & sealing
8 As per drawing TES Customer
fins after assembly and final machining
Low speed & Rated speed balancing of turbine
9 API-612 TES Customer
rotor
10 Final run out checking. As per drawing TES Customer
Prepared by Approved by
Engr.: I/C QA

Page 1 of 2
Turbo Engineering Services
An ISO 9001, ISO 14001 & BS OHSAS 18001 Certified Company
Plot No. 17/B, Phase- IV, I.P., Pashamylaram, Sangareddy Dist,
Hyderabad - 502307, Telangana, India.

Page 2 of 2

You might also like