Professional Documents
Culture Documents
WorleyParsons Vertical 2 Phase Separator Sizing
WorleyParsons Vertical 2 Phase Separator Sizing
CLIENT PROJ No
PROJECT CALC No
SUBJECT SHEET OF
Height to top tan line = 191 mm 150 mm 0.15 x diameter or specified min
Demister (Y/N) = Y
Inlet nozzle height = 500 mm inlet nozzle ID
Height to inlet from LAHH = 381 mm 300 mm 0.3 x diameter or specified min
Specified Min.
Height LAH to LAHH = 150 mm 150 mm specified hold up time or specified min
Height NLL to LAH = 200 mm 200 mm half specified holdup or specified min, and slug volume
Height LAL to NLL = 200 mm 200 mm half specified holdup or specified min
Height LALL to LAL = 200 mm 200 mm specified hold up time or specified min
Note
Slug Volume is 0.0 % of Control Volume between NLL and LAH.
555285493.xls
11/08/2021
file:///conversion/tmp/activity_task_scratch/555285493.xls
Min. liquid outlet = 100 mm
555285493.xls
11/08/2021
file:///conversion/tmp/activity_task_scratch/555285493.xls
Vertical Two-Phase Separator Sizing (English Units)
Standard Calculation WS-CA-PR-008, Rev. 3, "Re-Issued for Use", 12-Feb-03
Verified: Verification of WS-CA-PR-008, Rev. 3, "Re-Issued for Use", 12-Feb-03
CLIENT PROJ No
PROJECT CALC No
SUBJECT SHEET OF
Demister (Y/N) = Y
Inlet nozzle height = 20 in. inlet nozzle ID
Height to inlet from LAHH = 13 in. 12 in. 0.3 x diameter or specified min
Specified Min.
Height LAH to LAHH = 15.5 in. 6 in. specified hold up time or specified min
Height NLL to LAH = 23.3 in. 8 in. half specified holdup or specified min, and slug volume
Height LAL to NLL = 23.3 in. 8 in. half specified holdup or specified min
Height LALL to LAL = 15.5 in. 6 in. specified hold up time or specified min
Note
Slug Volume is 94.6 % of Control Volume between NLL and LAH.
555285493.xls
Date}
file:///conversion/tmp/activity_task_scratch/555285493.xls
Min. liquid outlet = 4 in.
555285493.xls
Date}
file:///conversion/tmp/activity_task_scratch/555285493.xls