Nokia Siemens Networks Flexi

BSC, S15, Site Documentation,


issue 01

Jumper Settings of the Cartridges in Flexi


BSC
DN70589297

Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010/10/29. All rights reserved

f Important Notice on Product Safety


Elevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.

The same text in German:


Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangsläufig bestimmte Teile der Geräte unter Span-
nung. Einige Teile können auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Körperverlet-
zungen und Sachschäden führen.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Geräte müssen die zutreffenden Sicherheitsbestimmungen erfüllen.

2 Id:0900d8058054cc72 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC

Table of Contents
This document has 19 pages.

Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

1 Overview of jumper settings for the cartridges in Flexi BSC . . . . . . . . . . 8

2 Jumper Settings of the Cartridges in Flexi BSC. . . . . . . . . . . . . . . . . . . . 9


2.1 CLOC-B Clock and synchronisation cartridge, C104222. . . . . . . . . . . . . 9
2.2 CLAC-B Clock and alarm cartridge, C104250 . . . . . . . . . . . . . . . . . . . . 11

3 SGC1C-A GSW and general TDM cartridge, C111459 . . . . . . . . . . . . . 14

4 ADMODD Address coding module connector with DIP switches, C108892


17
4.1 Setting of the address data in first delivery Flexi BSC . . . . . . . . . . . . . . 17
4.2 Setting of the address data in upgraded Flexi BSC . . . . . . . . . . . . . . . . 18

DN70589297 Id:0900d8058054cc72 3
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC

List of Figures
Figure 1 Jumper blocks of cartridge CLOC-B in upgraded Flexi BSC . . . . . . . . . . 9
Figure 2 Jumper blocks of the CLAC-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 3 Jumper block W1 on SGC1C-A cartridge in Flexi BSC . . . . . . . . . . . . . 14
Figure 4 DIP switch locations on ADMODD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

4 Id:0900d8058054cc72 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC

List of Tables
Table 1 Settings of the CL3TG (W1 and W2) . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 2 Biasing of switch side selection signal (W2) . . . . . . . . . . . . . . . . . . . . 11
Table 3 Adapting external frequency standard (W3 and W4) . . . . . . . . . . . . . . 11
Table 4 Setting the leading phase displacement (W1) . . . . . . . . . . . . . . . . . . . 12
Table 5 Unit address settings in the BSCC cabinet . . . . . . . . . . . . . . . . . . . . . . 13
Table 6 Unit address settings in the BSCD cabinet. . . . . . . . . . . . . . . . . . . . . . 13
Table 7 Jumper block W1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 8 Jumper settings on W1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 9 ADMODD connections for LOC_ID bits . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 10 ADMODD connections for SLOT_ID bits . . . . . . . . . . . . . . . . . . . . . . . 18
Table 11 ADMODD connections for LOC_ID bits . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 12 ADMODD connections for SLOT_ID bits . . . . . . . . . . . . . . . . . . . . . . . 18

DN70589297 Id:0900d8058054cc72 5
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC

6 Id:0900d8058054cc72 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Summary of changes

Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.

Changes between issues 1-0 and 1-1


Minor editorial changes made.

Issue 1-0
This the first issue of Jumper Settings of the Cartridges in Flexi BSC. It describes the
jumper settings in the first-delivery and in the upgrade delivery Flexi BSC.

DN70589297 Id:0900d8058055c620 7
Issue 1-1
Overview of jumper settings for the cartridges in Flexi Jumper Settings of the Cartridges in Flexi BSC
BSC

1 Overview of jumper settings for the car-


tridges in Flexi BSC
The Jumper Settings for the Cartridges in Flexi BSC provides the basic information
needed for setting the jumper settings of the cartridge which has jumpers to set in Flexi
BSCi. The settings are referred to as standard when no changes are required, and alter-
native if reconfiguration is needed.
Jumper settings are presented by the following:
CLOC-B
CLAC-B
SGC1C-A
ADMODD
The setting instructions for the plug-in-units in the CLOC-B, CLAC-B and SGC1C-A car-
tridges are described in Jumper Settings of the Plug-in Units in Flexi BSC.

8 Id:0900d80580555ecb DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC

2 Jumper Settings of the Cartridges in Flexi


BSC

2.1 CLOC-B Clock and synchronisation cartridge, C104222


The CLOC-B cartridge is used in the BSCC cabinet in upgrade deliveries when BSC3i
network elements are upgraded to Flexi BSC and when the upgraded Flexi BSC is used
as the BSC-part of the combined BSC/TCSM installation option.

D0V 11 10 9 8 7 6 5 4 3 2 1
R05 R04 R03 R02 R01 R00 0
W1 1
2
3 1

13 12 11 10 9 8 7 6 5 4 3 2 1
10
W2 2
31

R 3
W3 2
1

1
W4 2
3
D0V
UB UB

PP2 PP1

B0V B0V
X
W2 W1

S
W3

S05 S04 S03 S02 S01 S00 W4

DN98619018
Figure 1 Jumper blocks of cartridge CLOC-B in upgraded Flexi BSC

Standard settings
Jumpers for the standard settings (shown in figure Jumper blocks of cartridge CLOC-B
in upgraded Flexi BSC) are set at the factory, and normally there is no need to change
them.
The CLOC-B cartridge accepts two CL3TG plug-in units, a primary active unit and a
redundant passive unit in reserve.
The additional wirings are made using (U) jumper connectors.

Setting the operating mode of the CL3TG plug-in unit


The operating mode of the CL3TG is set using jumpers in the jumper blocks W1 and W2.
When not set, the signals are in the normal state (state 1). The 0-state is obtained by

DN70589297 Id:0900d805803c7c9e 9
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC

placing a jumper between pins 1 and 2 or by interconnecting the pins by wiring. Nor-
mally, the jumpers are installed between pins 2 and 3 (state 1).
The unused basic timing outputs can be closed in both the active and the passive unit
in groups of 5 pairs by means of _CLOFF1 to 3 signals (0-state). Normally, however, all
basic timing outputs of the active unit are set active (1-state).
The basic timing bus outputs of the passive unit to the CLAB-S units can be closed with
the CLOFF4 signal (0-state). Normally, the bus outputs of the passive unit are active (1-
state). The basic timing outputs of the passive unit can be activated with the BUEN
signal (0-state). Normally, the basic timing outputs of the passive unit are closed (1-
state).
Settings of the CL3TG (W1 and W2) are presented in the following table.

Pins Signal State Meaning


W1: 1, W2: 1 _TG0FF 0 PCM time slots 0 to 23 closed
1 PCM time slots 0 to 23 open (default
setting)
W1: 2, W2: 2 BU 0 No backup unit
1 Backup unit exists (default setting)
W1: 3, W2: 3 PCM 0 PCM interface 2Mbit/s (RSS use)
1 PCM interface 4 Mbit/s (default setting)
W1: 4, W2: 4 CGCL 0 Independent changeover disabled
1 Independent changeover enabled
(default setting)
W1: 5, W2: 5 BUEN 0 8MU1 to 15, FPU1 to 15 open in
passive unit if CLOFFn = 1
1 8MU1 to 15, FPU1 to 15 closed in
passive unit (default setting)
W1: 6, W2: 6 _CLOFF4 0 16MCB1 to 4, FPCB1 to 4 closed in
passive unit.
1 16MCB1 to 4, FPCB1 to 4 open in
passive unit (default setting).
W1: 7, W2: 7 _CLOFF3 0 8MU11 to 15, FPU11 to 15 closed in
active and in passive unit
1 8MU11 to 15, FPU11 to 15 open in
active unit (default setting)
W1: 8, W2: 8 _CLOFF2 0 8MU6 to 10, FPU 6 to 10 closed in
active and passive unit
1 8MU6 to 10, FPU6 to 10 open in active
unit (default setting)
W1: 9, W2: 9 _CLOFF1 0 8MU1 to 5, FPU1 to 5 closed in active
and in passive unit
1 8MU1 to 5, FPU 1 to 5 open in active
unit (default setting)

Table 1 Settings of the CL3TG (W1 and W2)

10 Id:0900d805803c7c9e DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC

Pins Signal State Meaning


W1: 10, W2: 10 L2M 0 Sending to PCM circuit delayed by 61
ns
1 Sending to PCM circuit is not delayed
(default setting)
W1: 11, W2: 11 RSS 0 Used in RSS
1 Used in upgraded Flexi BSC / BSC3i
(default setting)

Table 1 Settings of the CL3TG (W1 and W2) (Cont.)

Biasing of the switch changeover selection signal


No biasing is applied to the upgraded Flexi BSC application. The biasing is made using
jumpers in jumper block W2 on vertical rows 12 and 13.

Use Row Jumper Meaning


Flexi BSC / W2: 12 2-3 No biasing
BSC3i
W2: 13 2-3 No biasing

Table 2 Biasing of switch side selection signal (W2)

Adaptation of external frequency standards with CL3TG equipment


The synchronisation signals of an external frequency standard are adapted at jumper
blocks W3 and W4.

Jumper block Jumper Meaning


W3, W4 2-3 120 ohm balanced connection
W3, W4 1-2 75 ohm unbalanced connection

Table 3 Adapting external frequency standard (W3 and W4)

2.2 CLAC-B Clock and alarm cartridge, C104250


The CLAC-B cartridge is used in upgrade deliveries when BSC3i elements are
upgraded to Flexi BSC and when the upgraded Flexi BSC is used as the BSC-part of
the combined BSC/TCSM installation option.

DN70589297 Id:0900d805803c7c9e 11
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC

R04 R03 R02 R01 R00


D0V

UB UB
W1 D0V STANDARD SETTINGS

W2
PP1
B0V
X 1 0
B0V 3 2 1
PP2 LD0
W3 LD1
LD2
LD3
LD4 W1

ALTERNATIVE SETTINGS
S
1 0

UA5
UA7
UA6

UA4
UA3
UA2
UA1
3 2 1 1 0
UA1 2
UA2 3 1
UA3
W3
D0V

UA4
S04 S03 S02 S01 S00 UA5
UA6
UA7 W2
DN98619006

Figure 2 Jumper blocks of the CLAC-B


The CLAC-B cartridge accepts two CLAB-S plug-in units: Even CLAB-S plug-in unit in
slot 00 is the primary or active unit, and odd CLAB-S plug-in unit in slot 03 is the redun-
dant or passive unit.

Standard settings (W1)


Jumpers for the standard settings (as shown in figure Jumper blocks of the CLAC-B, and
presented in the following table) are set at the factory with W1. In normal operation,
there is no need to change them.

Jumper Setting
W1: LD0 2-3 ON
W1: LD1 2-3 ON
W1: LD2 2-3 ON
W1: LD3 2-3 ON
W1: LD4 2-3 ON

Table 4 Setting the leading phase displacement (W1)

The transfer delay compensation of the basic timing bus is set automatically with the
wiring connector AWM03 placed on the motherboard in position B01S1. The setting of
the wiring connector passes by these jumper settings.

12 Id:0900d805803c7c9e DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC

Unit address settings in the BSCC cabinet (W2, W3)


The CLAC-B cartridge is installed in position 5.4 of the BSCC cabinet.

Cabinet Position Setting Note


BSCC 5.4 W2/UA1:1-2 Unit address settings of the
W3/UA1:1-2 CLAB-S plug-in unit,
addresses 0 (00H) and 1
W2/UA2:1-2 (01H).
W3/UA2:1-2
W2/UA3:1-2
W3/UA3:1-2
W2/UA4:1-2
W3/UA4:1-2
W2/UA5:1-2
W3/UA5:1-2
W2/UA6:1-2
W3/UA6:1-2
W2/UA7:1-2
W3/UA7:1-2

Table 5 Unit address settings in the BSCC cabinet

Unit address settings in the BSCD cabinet (W2, W3)


The CLAC-B cartridge is installed in position 1.10 of the BSCD cabinet.

Cabinet Position Setting Note


BSCD 1.10 W2/UA1:2-3 Unit address settings of the
W3/UA1:2-3 CLAB-S plug-in unit,
addresses 2 (02H) and 3
W2/UA2:1-2 (03H).
W3/UA2:1-2
W2/UA3:1-2
W3/UA3:1-2
W2/UA4:1-2
W3/UA4:1-2
W2/UA5:1-2
W3/UA5:1-2
W2/UA6:1-2
W3/UA6:1-2
W2/UA7:1-2
W3/UA7:1-2

Table 6 Unit address settings in the BSCD cabinet.

DN70589297 Id:0900d805803c7c9e 13
Issue 1-1
SGC1C-A GSW and general TDM cartridge, C111459 Jumper Settings of the Cartridges in Flexi BSC

3 SGC1C-A GSW and general TDM cartridge,


C111459
On 14 level, the SGC1C-A cartridge is used in the first-delivery Flexi BSC cabinet
(BSCC).

A A A A A A A A A A A A A A A A A A A A

1
B B B B B B B B B B B B B B B B B B B B

2
1 23
16
A A A A A A A A A A A A A A A A A
PP5 PP4 PP3
W1

A 1 A A

B B A A A A A A A A A B A A A A A A A A

39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19

A A A A A A A A A A A A A A A A A A
A
C
1 E
G
B B B B B B B B B B B B B B B B B B
J
L
2 N
P
R
PP1
A A A A A A A A
PP1
A A A A A A A A T
V
3 X
A A
Z
B
B B B B B B B B
D
F
4
H
B A A A A A A A A B
K
M
8 7 6 5 4 3 2 1 O
Q
S
18 17 16 15 14 13 12 11 10 9 U
W
DN70596663 Y

Figure 3 Jumper block W1 on SGC1C-A cartridge in Flexi BSC


Settings on jumper block W1 are used for setting the operating mode of the CL3TG-UA
plug-in unit. Normally, the jumpers are installed between pins 2 and 3 (state 1). The 0-
state is obtained by placing a jumper between pins 1 and 2 or by interconnecting the pins
by wiring.
The settings of the CL3TG-UA (W1) on the SGC1C-A cartridge are presented in the fol-
lowing tables.

14 Id:0900d80580276800 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC SGC1C-A GSW and general TDM cartridge, C111459

Signals
Row Pin 1 Pin 2 Pin 3
16 FS2B GND GND
15 FS1B GND GND
14 CCL0 AL000 -
13 CSW B CS1 -
12 CSW A GND GND
11 _RSS GND GND
10 _L2M GND GND
9 _CLOFF1 GND GND
8 _CLOFF2 GND GND
7 _CLOFF3 GND GND
6 _CLOFF4 GND GND
5 _BUEN GND GND
4 CGCL GND GND
3 PCM GND GND
2 BU GND GND
1 _TGOFF GND GND

Table 7 Jumper block W1

Position State Jumper Meaning Note


External reference signal 2, termination 75 ohm
W1 - row 16 0 1-2 for unbalanced interface
External reference signal 2, termination 120 ohm; default
1 2-3 for balanced interface setting
External reference signal 1, termination
W1 - row 15 0 1-2 for unbalanced interface 75 ohm
External reference signal 1, termination 120 ohm; default
1 2-3 for balanced interface setting
Set in the upper
Routing card control loop to alarm SGC1C-A cartridge in
W1 - row 14 0 1-2 system which CLS 0 is located
Set in the lower
Routing card control loop to alarm SGC1C-A cartridge in
1 2-3 system which CLS 1 is located
W1 - row 13 and Group switch changeover signal is set
W1 - row 12 0 1-2 permanently for GSW 0 side
Group switch changeover signal follows
the GSW side changes; that is, no
1 2-3 biasing is applied to Flexi BSC Default setting

Table 8 Jumper settings on W1

DN70589297 Id:0900d80580276800 15
Issue 1-1
SGC1C-A GSW and general TDM cartridge, C111459 Jumper Settings of the Cartridges in Flexi BSC

Position State Jumper Meaning Note


W1 - row 11 0 1-2 Used in RSS
1 2-3 Used in Flexi BSC Default setting
W1 - row 10 0 1-2 Sending to PCM circuit delayed by 61 ns
1 2-3 Sending to PCM circuit is not delayed Default setting
8MU1 - 8MU5, FPU1 - FPU5 closed in
W1 - row 9 0 1-2 the active and in the passive unit
8MU1 - 8MU5, FPU 1 - FPU5 open in the Default setting
1 2-3 active unit
8MU6 - 8MU10, FPU6 - FPU10 closed in
W1 - row 8 0 1-2 the active and in the passive unit
8MU6 - 8MU10, FPU6 - FPU10 open in Default setting
1 2-3 the active unit
8MU11 - 8MU15, FPU11 - FPU15 closed
W1 - row 7 0 1-2 in the active and in the passive unit
8MU11 - 8MU15, FPU11 - FPU15 open Default setting
1 2-3 in the active unit
16MCB1 - 16MCB4, FPCB1 - FPCB4
W1 - row 6 0 1-2 closed in the passive unit
16MCB1 - 16MCB4, FPCB1 - FPCB4 Default setting
1 2-3 open in the passive unit
8MU1 - 8MU15, FPU1 - FPU15 open in
W1 - row 5 0 1-2 the passive unit if CLOFFn is set to 2-3
8MU1 - 8MU15, FPU1 - FPU15 closed in Default setting
1 2-3 the passive unit
W1 - row 4 0 1-2 Independent changeover disabled
1 2-3 Independent changeover enabled Default setting
W1 - row 3 0 1-2 PCM interface 2Mbit/s
1 2-3 PCM interface 4 Mbit/s Default setting
W1 - row 2 0 1-2 No backup unit
1 2-3 Backup unit exists Default setting
W1 - row 1 0 1-2 PCM time slots 0 to 23 closed
1 2-3 PCM time slots 0 to 23 open Default setting

Table 8 Jumper settings on W1 (Cont.)

16 Id:0900d80580276800 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC ADMODD Address coding module connector with DIP
switches, C108892

4 ADMODD Address coding module connector


with DIP switches, C108892

LOCATION ID SLOT ID
(11)10 9 8 7 6 5 4 3 2 1 0 3 2 1 0

1 1

J1
0 0
S1 S2 S3 S4

DN03485537
Figure 4 DIP switch locations on ADMODD
The purpose of the Address Coding Module (ADMODD) is to set the address data to the
ESB plug-in units.
With the ADMODD module, it is possible to set LOCATION ID bits (11 DIP switches
equals to 11 LOC_ID bits) and SLOT ID bits (4 DIP switches equals to SLOT_ID bits).
There are four miniature DIP switch blocks on the ADMODD module (S1, S2, S3, and
S4).

4.1 Setting of the address data in first delivery Flexi BSC


In Flexi BSC S14-level first deliveries, the ADMODD is installed on the rear side of the
computer cartridge DC3C-B housing two MCMUs.
The following tables show setting of the address data in Flexi BSC. Note that DIP switch
numbers refer directly to the corresponding LOD_ID and SLOT_ID bits. If bit value is “0”,
switch setting 0 is selected; and if bit value is “1”, switch setting 1 is selected.

SLOT_ID bits
Logical cartridge position on shelf Cartridge shelf Cabinet index Cabinet row
ADMODD DIP (11 not 10 9 8 7 6 5 4 3 2 1 0 MSB
swith values for used) LSB MSB MS LSB MS LSB
B B
ESBxx in logical cartridge position 2 / on cartridge shelf 3 / in cabinet A / in cabinet row 1 / in cartridge slot
02 *)
0 0 1 0 1 1 0 0 0 0 1 0
ESBxx in logical cartridge position 2 / on cartridge shelf 3 / in cabinet A / in cabinet row 1 / in cartridge slot
07 *)
0 1 1 0 1 1 0 0 0 0 1 0
Notes:
*) The logical cartridge position 0 that is switched by DIP switch equals to the real cartridge position 0 or 1.

Table 9 ADMODD connections for LOC_ID bits

DN70589297 Id:0900d805804e6ad5 17
Issue 1-1
ADMODD Address coding module connector with DIP Jumper Settings of the Cartridges in Flexi BSC
switches, C108892

Plug-in unit slot in cartridge


SLOT_ID bits
ADMODD DIP swith values for 3 MSB 2 1 0 LSB
ESBxx in logical cartridge position 2 / on 0 0 1 0
cartridge shelf 3 / in cabinet A / in cabinet
row 1 / in cartridge slot 02 *)
ESBxx in logical cartridge position 2 / on 0 1 1 1
cartridge shelf 3 / in cabinet A / in cabinet
row 1 / in cartridge slot 07 *)
Notes:
*) The logical cartridge position 0 that is switched by DIP switch equals to the real car-
tridge position 0 or 1.

Table 10 ADMODD connections for SLOT_ID bits

4.2 Setting of the address data in upgraded Flexi BSC


In Flexi BSC S14-level upgrade deliveries when BSC3i 660/1000/2000 is upgraded to
Flexi BSC , the ADMODD is installed to the rear side of the computer cartridge CC4C-
A (that is, the MCMU) of the DX 200 M98 mechanics cabinets.

Logical cartridge position on Cartridge shelf Cabinet index Cabinet row


shelf
11 10 9 8 7 6 5 4 3 2 1 0
(not in (LSB) (MSB) (LSB) (MSB) (LSB) (MSB) (LSB) (MSB)
use)
ESBxx in logical cartridge position 0/ on cartridge shelf 2/ in cabinet A/ on cabinet row 1
0 0 0 0 0 1 0 0 0 0 1 0
ESBxx in logical cartridge position 1/ on cartridge shelf 2/ in cabinet A/ on cabinet row 1
0 1 0 0 0 1 0 0 0 0 1 0

Table 11 ADMODD connections for LOC_ID bits

Both in Table ADMODD connections for LOC_ID bits and in Table ADMODD connec-
tions for SLOT_ID bits, the logical cartridge position 0 (for MCMU), which is switched by
the DIP switch, equals to the real cartridge position 0 or 1. In addition, the logical car-
tridge position 1 (for MCMU), which is switched by the DIP switch, equals to the real car-
tridge position 2 or 3.

PIU slot in cartridge


SLOT_ID bits
ADMODD DIP 3 2 1 0
switch values for (MSB) (LSB)

Table 12 ADMODD connections for SLOT_ID bits

18 Id:0900d805804e6ad5 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC ADMODD Address coding module connector with DIP
switches, C108892

PIU slot in cartridge


SLOT_ID bits
in MCMU 0 cartridge 0 0 1 0
slot 02
in MCMU 0 cartridge 0 0 1 1
slot 03
in MCMU 1 cartridge 0 0 1 0
slot 02
in MCMU 1 cartridge 0 0 1 1
slot 03

Table 12 ADMODD connections for SLOT_ID bits (Cont.)

If the bits value is 0, then a switch setting 0 is selected. If the bits value is 1, then a switch
setting 1 is selected.
The DIP switch numbers refer directly to the corresponding LOD_ID and SLOT_ID bits.

DN70589297 Id:0900d805804e6ad5 19
Issue 1-1