Jumper Settings of the Cartridges in Flexi BSC
The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTA-
TION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDI-
RECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright © Nokia Siemens Networks 2010/10/29. All rights reserved
2 Id:0900d8058054cc72 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC
Table of Contents
This document has 19 pages.
Summary of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DN70589297 Id:0900d8058054cc72 3
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC
List of Figures
Figure 1 Jumper blocks of cartridge CLOC-B in upgraded Flexi BSC . . . . . . . . . . 9
Figure 2 Jumper blocks of the CLAC-B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Figure 3 Jumper block W1 on SGC1C-A cartridge in Flexi BSC . . . . . . . . . . . . . 14
Figure 4 DIP switch locations on ADMODD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4 Id:0900d8058054cc72 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC
List of Tables
Table 1 Settings of the CL3TG (W1 and W2) . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Table 2 Biasing of switch side selection signal (W2) . . . . . . . . . . . . . . . . . . . . 11
Table 3 Adapting external frequency standard (W3 and W4) . . . . . . . . . . . . . . 11
Table 4 Setting the leading phase displacement (W1) . . . . . . . . . . . . . . . . . . . 12
Table 5 Unit address settings in the BSCC cabinet . . . . . . . . . . . . . . . . . . . . . . 13
Table 6 Unit address settings in the BSCD cabinet. . . . . . . . . . . . . . . . . . . . . . 13
Table 7 Jumper block W1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 8 Jumper settings on W1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Table 9 ADMODD connections for LOC_ID bits . . . . . . . . . . . . . . . . . . . . . . . . 17
Table 10 ADMODD connections for SLOT_ID bits . . . . . . . . . . . . . . . . . . . . . . . 18
Table 11 ADMODD connections for LOC_ID bits . . . . . . . . . . . . . . . . . . . . . . . . 18
Table 12 ADMODD connections for SLOT_ID bits . . . . . . . . . . . . . . . . . . . . . . . 18
DN70589297 Id:0900d8058054cc72 5
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC
6 Id:0900d8058054cc72 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Summary of changes
Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.
Issue 1-0
This the first issue of Jumper Settings of the Cartridges in Flexi BSC. It describes the
jumper settings in the first-delivery and in the upgrade delivery Flexi BSC.
DN70589297 Id:0900d8058055c620 7
Issue 1-1
Overview of jumper settings for the cartridges in Flexi Jumper Settings of the Cartridges in Flexi BSC
BSC
8 Id:0900d80580555ecb DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC
D0V 11 10 9 8 7 6 5 4 3 2 1
R05 R04 R03 R02 R01 R00 0
W1 1
2
3 1
13 12 11 10 9 8 7 6 5 4 3 2 1
10
W2 2
31
R 3
W3 2
1
1
W4 2
3
D0V
UB UB
PP2 PP1
B0V B0V
X
W2 W1
S
W3
DN98619018
Figure 1 Jumper blocks of cartridge CLOC-B in upgraded Flexi BSC
Standard settings
Jumpers for the standard settings (shown in figure Jumper blocks of cartridge CLOC-B
in upgraded Flexi BSC) are set at the factory, and normally there is no need to change
them.
The CLOC-B cartridge accepts two CL3TG plug-in units, a primary active unit and a
redundant passive unit in reserve.
The additional wirings are made using (U) jumper connectors.
DN70589297 Id:0900d805803c7c9e 9
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC
placing a jumper between pins 1 and 2 or by interconnecting the pins by wiring. Nor-
mally, the jumpers are installed between pins 2 and 3 (state 1).
The unused basic timing outputs can be closed in both the active and the passive unit
in groups of 5 pairs by means of _CLOFF1 to 3 signals (0-state). Normally, however, all
basic timing outputs of the active unit are set active (1-state).
The basic timing bus outputs of the passive unit to the CLAB-S units can be closed with
the CLOFF4 signal (0-state). Normally, the bus outputs of the passive unit are active (1-
state). The basic timing outputs of the passive unit can be activated with the BUEN
signal (0-state). Normally, the basic timing outputs of the passive unit are closed (1-
state).
Settings of the CL3TG (W1 and W2) are presented in the following table.
10 Id:0900d805803c7c9e DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC
DN70589297 Id:0900d805803c7c9e 11
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC
UB UB
W1 D0V STANDARD SETTINGS
W2
PP1
B0V
X 1 0
B0V 3 2 1
PP2 LD0
W3 LD1
LD2
LD3
LD4 W1
ALTERNATIVE SETTINGS
S
1 0
UA5
UA7
UA6
UA4
UA3
UA2
UA1
3 2 1 1 0
UA1 2
UA2 3 1
UA3
W3
D0V
UA4
S04 S03 S02 S01 S00 UA5
UA6
UA7 W2
DN98619006
Jumper Setting
W1: LD0 2-3 ON
W1: LD1 2-3 ON
W1: LD2 2-3 ON
W1: LD3 2-3 ON
W1: LD4 2-3 ON
The transfer delay compensation of the basic timing bus is set automatically with the
wiring connector AWM03 placed on the motherboard in position B01S1. The setting of
the wiring connector passes by these jumper settings.
12 Id:0900d805803c7c9e DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC Jumper Settings of the Cartridges in Flexi BSC
DN70589297 Id:0900d805803c7c9e 13
Issue 1-1
SGC1C-A GSW and general TDM cartridge, C111459 Jumper Settings of the Cartridges in Flexi BSC
A A A A A A A A A A A A A A A A A A A A
1
B B B B B B B B B B B B B B B B B B B B
2
1 23
16
A A A A A A A A A A A A A A A A A
PP5 PP4 PP3
W1
A 1 A A
B B A A A A A A A A A B A A A A A A A A
39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19
A A A A A A A A A A A A A A A A A A
A
C
1 E
G
B B B B B B B B B B B B B B B B B B
J
L
2 N
P
R
PP1
A A A A A A A A
PP1
A A A A A A A A T
V
3 X
A A
Z
B
B B B B B B B B
D
F
4
H
B A A A A A A A A B
K
M
8 7 6 5 4 3 2 1 O
Q
S
18 17 16 15 14 13 12 11 10 9 U
W
DN70596663 Y
14 Id:0900d80580276800 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC SGC1C-A GSW and general TDM cartridge, C111459
Signals
Row Pin 1 Pin 2 Pin 3
16 FS2B GND GND
15 FS1B GND GND
14 CCL0 AL000 -
13 CSW B CS1 -
12 CSW A GND GND
11 _RSS GND GND
10 _L2M GND GND
9 _CLOFF1 GND GND
8 _CLOFF2 GND GND
7 _CLOFF3 GND GND
6 _CLOFF4 GND GND
5 _BUEN GND GND
4 CGCL GND GND
3 PCM GND GND
2 BU GND GND
1 _TGOFF GND GND
DN70589297 Id:0900d80580276800 15
Issue 1-1
SGC1C-A GSW and general TDM cartridge, C111459 Jumper Settings of the Cartridges in Flexi BSC
16 Id:0900d80580276800 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC ADMODD Address coding module connector with DIP
switches, C108892
LOCATION ID SLOT ID
(11)10 9 8 7 6 5 4 3 2 1 0 3 2 1 0
1 1
J1
0 0
S1 S2 S3 S4
DN03485537
Figure 4 DIP switch locations on ADMODD
The purpose of the Address Coding Module (ADMODD) is to set the address data to the
ESB plug-in units.
With the ADMODD module, it is possible to set LOCATION ID bits (11 DIP switches
equals to 11 LOC_ID bits) and SLOT ID bits (4 DIP switches equals to SLOT_ID bits).
There are four miniature DIP switch blocks on the ADMODD module (S1, S2, S3, and
S4).
SLOT_ID bits
Logical cartridge position on shelf Cartridge shelf Cabinet index Cabinet row
ADMODD DIP (11 not 10 9 8 7 6 5 4 3 2 1 0 MSB
swith values for used) LSB MSB MS LSB MS LSB
B B
ESBxx in logical cartridge position 2 / on cartridge shelf 3 / in cabinet A / in cabinet row 1 / in cartridge slot
02 *)
0 0 1 0 1 1 0 0 0 0 1 0
ESBxx in logical cartridge position 2 / on cartridge shelf 3 / in cabinet A / in cabinet row 1 / in cartridge slot
07 *)
0 1 1 0 1 1 0 0 0 0 1 0
Notes:
*) The logical cartridge position 0 that is switched by DIP switch equals to the real cartridge position 0 or 1.
DN70589297 Id:0900d805804e6ad5 17
Issue 1-1
ADMODD Address coding module connector with DIP Jumper Settings of the Cartridges in Flexi BSC
switches, C108892
Both in Table ADMODD connections for LOC_ID bits and in Table ADMODD connec-
tions for SLOT_ID bits, the logical cartridge position 0 (for MCMU), which is switched by
the DIP switch, equals to the real cartridge position 0 or 1. In addition, the logical car-
tridge position 1 (for MCMU), which is switched by the DIP switch, equals to the real car-
tridge position 2 or 3.
18 Id:0900d805804e6ad5 DN70589297
Issue 1-1
Jumper Settings of the Cartridges in Flexi BSC ADMODD Address coding module connector with DIP
switches, C108892
If the bits value is 0, then a switch setting 0 is selected. If the bits value is 1, then a switch
setting 1 is selected.
The DIP switch numbers refer directly to the corresponding LOD_ID and SLOT_ID bits.
DN70589297 Id:0900d805804e6ad5 19