Mark 96C Series: Sanitary Pressure Regulators (1/2"-1")
Mark 96C Series: Sanitary Pressure Regulators (1/2"-1")
Sanitary Valves
Sanitary Pressure Regulators (1/2"–1")
FEATURES
• CRN Registration Number Available
AVAILABLE FINISHES
• Soft seat capability for ANSI Class VI shutoff Body
• No guiding surfaces in the fluid – prevents particulate • Standard: 20 Ra µ in (.5 Ra µm) mechani-
generation cal finish and electropolish on inside wetted
• 100% 316L barstock body and metal trim surfaces; machine finish and electropolish
on exterior
SPECIFICATIONS
Corrosion resistant
316SST housing and
T-handle
Guiding above diaphragm
eliminates particulate generation
Proprietary Jorlon
diaphragm for unsurpassed
Protects diaphragm performance and life
from overstroking
316L barstock
body/trim
Clamped body
design for easy
disassembly Body/ferrule heat numbers
Soft seat for ANSI Class
on bottom surface for
VI shutoff available
material traceability
-3-
MARK 96C SERIES SANITARY PRESSURE REGULATORS
-4-
MARK 96C SERIES SANITARY PRESSURE REGULATORS 96C/0721
ORDERING SCHEMATIC
1 2 3 4 5 6 7 8 9 10 11 12
— — 1
1 Model 8 O-Ring/Diaphragm
96C Standard EE EPDM/EPDM Diaphragm 1.5-5.5Cv
JE O-Ring EPDM/Jorlon Diaphragm 1.5-5.5Cv
JK O-Ring Kalrez/Jorlon Diaphragm 1.5-5.5Cv
2 Size JS O-Ring Silicon/Jorlon Diaphragm 1.5-5.5Cv
050 1/2" (DN15) JV O-Ring Viton/Jorlon Diaphragm 1.5-5.5Cv
075 3/4" (DN20) TY Teflon Encaps. Viton/Jorlon Diaphragm 1.5-5.5Cv
100 1" (DN25) B5 Buna-N/Jorlon 0.3-1.2Cv
E5 EPDM/EPDM Diaphragm 0.3-1.2Cv
J5 O-Ring EPDM/Jorlon Diaphragm 0.3-1.2Cv
3 Body Material K5 O-Ring USP-Kalrez/Jorlon Diaphragm 0.3-1.2 Cv
6L ASME SA479 316L (UNS 31603) S5 Silicon/Jorlon Diaphragm 0.3-1.2Cv
6E EN 10272:2000 GR 1.4435 V5 Viton/Jorlon Diaphragm 0.3-1.2Cv
12 Actuator Finish
7 Trim – Cv (Kv) & Seat AA Standard
3 0.3 (0,24) Hard Seat B 2.5 (2,15) Hard Seat
4 0.3 (0,24) PEEK Seat C 2.5 (2,2) Teflon Seat
5 0.5 (0,43) Hard Seat D 2.5 (2,15) Jorlon Seat 13 PED Compliance
6 0.5 (0,43) PEEK Seat L 5.5 (4,7) Hard Seat 00 Not Required
Y 1.2 (1,03) Hard Seat M 5.5 (4,7) Teflon Seat 0G SEP Compliant
1 1.2 (1,03) PEEK Seat N 5.5 (4,7) Jorlon Seat ZZ Non-Standard
A 1.5 (1,3) Hard Seat
Note: Steriflow does not recommend using metal seated
trim on any service where the flow will be deadheaded
downstream of the pressure reducing regulator. Use an
appropriate Teflon, Jorlon or Peek soft seat for the trim
instead.