EN HE Q-NCOV-01G 4. Press the nozzle cap tightly onto the tube.

STANDARDDQ Specimens in transport media]

COVID-19Ag TestAg
STANDARDQ COVID-19
1. Using a micropipette, collect the 350yl of specimen frorn the collection
or VTM. Mix the specimen with an extraction buffer.
2. Press the nozzle cap tightly onto the tube.
PLEAS BEA NARYTte REOR nu PERI ORM THE TEST SD BIOSENSOR
KIT CONTENTS

coViD-19 Ag Test

Test device
TAMDAD

(individually in
a foli pouch with desiccant)
Extraction buffer tube Nozzle capP
350ul

ANALYSIS OFSPECIMEN
1-7 Few times mix

1. Apply 3 drops of extracted specimen to the specimen well of the test de


2. Read the test result in 15-30 minutes.

Sterile swab Instructions for use

PREPARATION AND TEST PROCEDURE


drops Read
in 15-30 mins.
Do nat read
PREPARATION after 30 mins
Carefully read instructions for using the STANDARD Q COVID-19 Ag Test.
Check the expiry date at the back of the foil
15-30 mins
pouch. Do not use the kit, if
expiry date has passed.
3. Check the test device and the desiccant pack in the foil pouch.
covID-19
Do not read test results after 30 minutes. It
may give fal
TANDARD OCoVD-19 Yellow results.
L UResuIt windoW CAUTION
Green

S D BIOSENsOR
-.
2
Specimen well AYellow: Valid INTERPRETATION OF TEST RESULT
Green: Invalid

Foil pouch> Test device> <Desiccant> *"C"Control Line "T" Test

COLLECTION OF SPECIMEN Negative


[Nasopharyngeal swab]
1. Inserta sterile swab into the nostril of the
patient, swab over the surface of the posterior
nasopharyrnx. Withdraw the sterile swab from the Positive
nasal cavity.

2. Insert the swab into an extraction buffer T C T


tube. Invalid
While squeezing the buffer tube, stir the swab more
than 5tirmes x5
1. A colored band will
appear in the top section of the result window to s
that the test is working
2. A colored band will
properly. This band is control line (C).
appear in the lower section of the result window.
band is test line of SARS
3. 3 Even it the control line is
COV- 2 antigen ().
Remove the swab while faint, or the test line isn't uniform, the test
the tube to extract the
squeezing the sides of be considered to be sh
liquid from the swab. pertormed properly and the test result shoulc
interpreted as a positive result.
*The presence of any line no matter how faint the result is conside
positive
Positive results should be considered in conjunction with the clin
history and other data available.