Air Conditioning

Technical Data

FXZQ-A

> FXZQ15A2VEB
> FXZQ20A2VEB
> FXZQ25A2VEB
> FXZQ32A2VEB
> FXZQ40A2VEB
> FXZQ50A2VEB
• Indoor Unit • FXZQ-A

TABLE OF CONTENTS
FXZQ-A

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Safety device settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5 Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Cooling Capacity Tables ............................................. 9
Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

7 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Dimensional Drawings with Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

8 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
9 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

10 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
11 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Sound Pressure Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

12 Air flow patterns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18


Air Flow Pattern - Cooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Air Flow Pattern - Heating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

• VRV Systems • FXZQ-A 1


• Indoor Unit • FXZQ-A

1 Features

c t s t im a ne lUt f s rAy yoS- loQ dlZV nXuR Unique


FVI design in the market that integrates fully flat into the ceiling
• Fully flat integration in standard architectural ceiling tiles, leaving only • Individual flap control: flexibility to suit every room layout without
8mm changing the location of the unit!
• Remarkable blend of iconic design and engineering excellence with • Reduced energy consumption thanks to specially developed small
an elegant finish in white or a combination of silver and white tube heat exchanger, DC fan motor and drain pump
• Two optional intelligent sensors improve energy efficiency and • Optional fresh air intake
1 comfort • Standard drain pump with 630mm lift increases flexibility and
• 15 class unit especially developed for small or well-insulated rooms, installation speed
such as hotel bedrooms, small offices, etc.

Inverter Presence & Home leave Fan only Draught Auto cooling- Whisper quiet Ceiling soiling Individual flap
floor sensor operation prevention heating prevention control
changeover

Vertical auto Fan speed Dry programme Air filter Weekly timer Infrared remote Wired remote Centralised Auto-restart
swing steps control control control

Self diagnosis Multi tenant Drain pump kit

2 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

2 Specifications

2-1 Technical Specifications


Cooling capacity Sensible capacity Nom. kW
FXZQ15A
1.40
FXZQ20A
1.70
FXZQ25A
2.00
FXZQ32A
2.40
FXZQ40A
3.30
FXZQ50A
4.10
3
Latent capacity Nom. kW 0.300 0.500 0.800 1.20 1.50
Total capacity Nom. kW 1.70 2.20 2.80 3.60 4.50 5.60
Heating capacity Total capacity Nom. kW 1.90 2.50 3.20 4.00 5.00 6.30
Power input - 50Hz Cooling Nom. kW 0.043 0.045 0.059 0.092 2
Heating Nom. kW 0.036 0.038 0.053 0.086
Dimensions Unit Height mm 260
Width mm 575
Depth mm 575
Packed unit Height mm 280
Width mm 686
Depth mm 597
Weight Unit kg 15.5 16.5 18.5
Packed unit kg 17 18 19
Casing Material Galvanised steel plate
Decoration panel Model BYFQ60C2W1W
Colour White (N9.5)
Dimensions Height mm 46
Width mm 620
Depth mm 620
Weight kg 2.8
Decoration panel 2 Model BYFQ60C2W1S
Colour SILVER
Dimensions Height mm 46
Width mm 620
Depth mm 620
Weight kg 2.8
Decoration panel 3 Model BYFQ60B2W1
Colour White (RAL9010)
Dimensions Height mm 55
Width mm 700
Depth mm 700
Weight kg 2.7
Decoration panel 4 Model BYFQ60B3W1
Colour WHITE (RAL9010)
Dimensions Height mm 55
Width mm 700
Depth mm 700
Weight kg 2.7
Heat exchanger Inside length mm 1,295 1,248
Outside length mm 1,342
Rows Quantity 2 3
Fin pitch mm 1.20
Passes Quantity 4 5 7
Face area m² 0.218 0.290 0.300
Stages Quantity 12 16
Empty tubeplate Quantity 0
hole
Fin Type Cross fin coil (multi slit fins and hi-XA tubes)
Fan Type Turbo fan
Quantity 1
Air flow rate - 50Hz Cooling High m³/min 8.5 8.7 9.0 10.0 11.5 14.5
Mediu m³/min 7.00 7.50 8.00 8.50 9.50 12.5
m
Low m³/min 6.5 7.0 8.0 10.0
Heating High m³/min 8.5 8.7 9.0 10.0 11.5 14.5
Mediu m³/min 7.0 7.5 8.0 8.5 9.5 12.5
m
Low m³/min 6.5 7.0 8.0 10.0

• VRV Systems • FXZQ-A 3


• Indoor Unit • FXZQ-A

2 Specifications

2-1 Technical Specifications FXZQ15A FXZQ20A FXZQ25A FXZQ32A FXZQ40A FXZQ50A


Fan motor Model QTS32D15M
Speed Steps 3
Air filter Type Resin net
Sound power level Cooling High dBA 49 50 51 54 60
Sound pressure level Cooling Medium dBA -
2
High dBA 31.5 32.0 33.0 33.5 37.0 43.0
Nom. dBA 28.0 29.5 30.0 32.0 40.0
Low dBA 25.5 26.0 28.0 33.0
Heating High dBA 31.5 32.0 33.0 33.5 37.0 43.0
Nom. dBA 28.0 29.5 30.0 32.0 40.0
Low dBA 25.5 26.0 28.0 33.0
Refrigerant Type R-410A
GWP 2,087.5
Piping connections Liquid Type Flare connection
OD mm 6,35
Gas Type Flare connection
OD mm 12.7
Drain VP20 (I.D. 20/O.D. 26)
Heat insulation Foamed polystyrene / Foamed polyethylene
Sound absorbing insulation Foamed polyurethane
Control systems Infrared remote control BRC7EB530W (standard panel) / BRC7F530W (white panel) / BRC7F530S (grey panel)
Wired remote control BRC1H519W/S/K / BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52
Simplified wired remote control for hotel -
applications
Standard Accessories : Operation manual; Quantity : 1;
Standard Accessories : Installation manual; Quantity : 1;
Standard Accessories : Drain hose; Quantity : 1;
Standard Accessories : Metal clamp for drain hose; Quantity : 1;
Standard Accessories : Washer for hanger bracket; Quantity : 8;
Standard Accessories : Screws; Quantity : 4;
Standard Accessories : Insulation for fitting; Quantity : 2;
Standard Accessories : Sealing pad; Quantity : 4;
Standard Accessories : Clamps; Quantity : 7;

2-2 Electrical Specifications FXZQ15A FXZQ20A FXZQ25A FXZQ32A FXZQ40A FXZQ50A


Power supply Name VE
Phase 1~
Frequency Hz 50/60
Voltage V 220-240/220
Current - 50Hz Minimum circuit amps (MCA) A 0.3 0.4 0.6
Maximum fuse amps (MFA) A 16
Full load amps Total A 0.2 0.3 0.5
(FLA)

4 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

2 Specifications

Notes
3
Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB
Dimensions do not include control box
The sound power level is an absolute value indicating the power which a sound source generates.
Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
2
Maximum allowable voltage range variation between phases is 2%.
MCA/MFA: MCA = 1.25 x FLA
MFA ≤ 4 x FLA
Next lower standard fuse rating minimum 16A
Contains fluorinated greenhouse gases
Instead of a fuse, use a circuit breaker
Select wire size based on the value of MCA

• VRV Systems • FXZQ-A 5


• Indoor Unit • FXZQ-A

3 Electrical data
3-1 Electrical Data

FXZQͲA

3
Unit Powersupply IFM Powerinput[W]
Model Hz Voltage Voltagerange MCA MFA FLA Cooling Heating
FXZQ15A2VEB 0,3 16 0,2 43 36
FXZQ20A2VEB 0,3 16 0,2 43 36
FXZQ25A2VEB MAX.264/MAX.242 0,3 16 0,2 43 36
50/60 220Ͳ240/220
FXZQ32A2VEB MIN.198/MIN.198 0,4 16 0,3 45 38
FXZQ40A2VEB 0,4 16 0,3 59 53
FXZQ50A2VEB 0,6 16 0,5 92 86

Notes
1) Voltagerange
Theunitsaresuitableforusewithelectricalsystemsinwhichthevoltagesuppliedtotheunitterminalsisnotbeloworabove thelistedrangelimits.

2) Themaximumallowablevoltagethatisunbalancedbetweenphasesisͼ2ͼ%.
3) MCA/MFA
MCA=1.25xFLA
MFAч4xFLA
Thenextlowerstandardfuseratingisminimumͼ16ͼampere.
4) SelectthewiresizeaccordingtotheMCA.
5) Useacircuitbreakerinsteadofafuse.

Symbols
MCA: MinimumCircuitAmpere[A]
MFA: MaximumFuseAmpere[A]
FLA: FullLoadAmpere[A]
IFM: Indoorfanmotor

3D103218

6 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

4 Safety device settings


4-1 Safety Device Settings

• VRV Systems • FXZQ-A 7


• Indoor Unit • FXZQ-A

5 Options
5-1 Options

FXZQͲA

Availability
Compatibility VRV SA
FXZQ15A2VEB FFQ25C2VEB
FXZQ20A2VEB FFQ35C2VEB

BYFQ60C2W1W
New/Existing

BYFQ60C2W1S
BYFQ60B2W1
BYFQ60B3W1
FXZQ25A2VEB FFQ50C2VEB
FXZQ32A2VEB FFQ60C2VEB
Optionkit Productname
5
FXZQ40A2VEB
FXZQ50A2VEB

DecorationpanelͲ Standard BYFQ60B2W1 New Ͳ Ͳ Ͳ ‫ض‬ ‫ض‬


DecorationpanelͲ Standard BYFQ60B3W1 New Ͳ Ͳ Ͳ ‫ض‬ ‫ض‬
DecorationpanelͲ White BYFQ60C2W1W New Ͳ Ͳ Ͳ ‫ض‬ ‫ض‬
DecorationpanelͲ Silver BYFQ60C2W1S New Ͳ Ͳ Ͳ ‫ض‬ ‫ض‬
SensorkitͲ White BRYQ60A2W༅ New No Yes No ‫ض‬ ‫ض‬
SensorkitͲ Silver BRYQ60A2S༅ New No No Yes ‫ض‬ ‫ض‬
Airdischargeoutletsealingmember BDBHQ44C60 New Yes Yes Yes ‫ض‬ ‫ض‬
Panelspacer KDBQ44B60 Existing Yes No No ‫ض‬ ‫ض‬
LongͲlifereplacementfilter KAFQ441BA60 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Freshairintakekit KDDQ44XA60 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Remotecontrol|Infraredtype|HP BRC7EB530W༃༄ New Yes No No ‫ض‬ ‫ض‬
Remotecontrol|Infraredtype|ͼHPͼ|White BRC7F530W༃༄ New No Yes No ‫ض‬ ‫ض‬
Remotecontrol|Infraredtype|ͼHPͼ|Silver BRC7F530S༃༄ New No No Yes ‫ض‬ ‫ض‬
Wiredremotecontrol BRC1D528༄ Existing Yes Yes Yes ‫ض‬ ‫ض‬
Wiredremotecontrol BRC1E53A7༊/BRC1E53B7་/BRC1E53C7༌། Existing Yes Yes Yes ‫ض‬ ‫ض‬
Simplifiedremotecontrol(withoperationmodeselectorbutton) BRC2E52C༇། New Yes Yes Yes ‫ض‬ ‫ض‬
Simplifiedremotecontrol(withoutoperationmodeselectorbutton) BRC3E52C༇། New Yes Yes Yes ‫ض‬ ‫ض‬
Centralremotecontrol DCS302B51 Existing Yes Yes Yes ‫ض‬ ‫ض‬
UnifiedON/OFFcontroller DCS301B51 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Scheduletimer DST301B51 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Wiringadaptorforelectricalappendices KRP1B57 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Wiringadaptorforelectricalappendices KRP2A526 Existing Yes Yes Yes ‫ض‬ ‫ظ‬
Wiringadaptorforelectricalappendices KRP4A53 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Wiringadaptor(hourmeter) EKRP1B2 Existing Yes Yes Yes ‫ض‬ ‫ض‬
InstallationboxforadaptorPCB KRP1B101,KRP1BA101 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Remotesensor KRCS01Ͳ4B Existing Yes Yes Yes ‫ض‬ ‫ض‬
PCBformultiͲtenantindoorunits DTA114A61 Existing Yes Yes Yes ‫ض‬ ‫ظ‬
iTouchController DCS601C51 Existing Yes Yes Yes ‫ض‬ ‫ض‬
Digitalinputadaptor BRP7A53༈ New Yes Yes Yes ‫ض‬ ‫ض‬

༃: Thesensingfunctionisnotavailable.
༄: TheindependentlyͲcontrollableͲflapsfunctionisnotavailable.
༅: ThisoptioncannotbeusedwithͼRRͼandͼRQͼmodels.
༆: TheindependentlyͲcontrollableͲflapsfunctionisnotavailableincombinationwithͼRRͼandͼRQͼmodels.
༇: Includedlanguagesare:
Languagepackͼ1ͼ:English,German,French,Dutch,Spanish,Italian,andPortuguese.
WithPCcableͼEKPCCAB3ͼincombinationwiththeUpdaterPCsoftware,youcanadditionallychangethelanguageto:
Languagepackͼ2ͼ:English,Bulgarian,Croatian,Czech,Hungarian,Romanian,andSlovenian.
Languagepackͼ3ͼ:English,Greek,Polish,Russian,Serbian,Slovak,andTurkish.
༈: OnlypossibleincombinationwithremotecontrolͼBRC2/3E52C,BRC1E53A/B/C7ͼ.
༉: RequiresinstallationboxforadaptorPCB
༊: Includedlanguagesare:English,German,French,Italian,Spanish,Portuguese,andDutch.
་: Includedlanguagesare:English,Czech,Croatian,Hungarian,Slovenian,Romanian,andBulgarian.
༌: Includedlanguagesare:English,Russian,Greek,Turkish,Polish,Albanian,andSlovak.
།: Languagepackͼ3ͼofcontrollerͼBRC1E53C7ͼisdifferentfromthatofcontrollerͼBRC2/3E52C7ͼ.
༎: EditabledataforthisdrawingareavailableintheͼGDE(EͲBOM)ͼsystem.
3D102205

8 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

6 Capacity tables
6-1 Cooling Capacity Tables

• VRV Systems • FXZQ-A 9


• Indoor Unit • FXZQ-A

6 Capacity tables
6-2 Heating Capacity Tables

10 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

7 Dimensional drawings
7-1 Dimensional Drawings with Accessories

FXZQ-A 㻣㻜㻜
Note ·2·
·300· or less
㻡㻤㻡䡚 㻢㻢㻜 㻌 Ceiling opening 㻤㻥
㻞㻝㻜 3
㻡㻟㻟 㻌 Suspension position

㻤㻥
Piping side 㻟㻞㻜
Service access panel
·450 x 450mm· or more 㻝
㻜㻜

㻝㻡㻜

㻡㻟㻟 㻌Suspension position


㻣㻜㻜

㻡㻤㻡䡚 㻢㻢㻜 㻌Ceiling opening


㹀 4-M4 Hole Outdoor air intake
7

㻟㻝

䠔 (direct connection)
View ·B·
Drain side
Required space
·1500mm· or more
View ·A·
 㹼

㻟㻞㻜
䠏 䠍 㻟㻠㻡
㻡㻥㻜
䠑 㻢㻞㻚㻡 㻡㻣㻡 㻢㻞㻚㻡 ·1500mm· or more
㻝㻥㻢 㻢㻟 When closing the air outlet, the required

Adjustable


㻤㻡㻜

space is ·200·mm or more.

·295· or more
㻞㻢㻜

㻞㻤㻡

View ·C· 㹁 Item. Part name

Required space 


㻞㻜㻡

㻝㻤㻟
㻝㻠㻡
㻞㻡


1 Liquid pipe connection ·Ø 6.4·

·45· or less 2 Gas pipe connection ·Ø 12.7·

·1500· or more
·45· or less

·2500· or more
Ceiling height
㻟㻜
㻡㻡

㻝㻣㻞 Note ·4·


Suspension position 㻞㻝㻝 㻢㻞㻚㻡 㻡㻣㻡 Note ·4· 㻢㻞㻚㻡 Drain outlet ·VP20·
3 Outer: ·Ø26·
㻠㻙㻹㻤䡚㻹㻝㻜

7RÀRRU
㸿
4 Power supply

5 Remote control wiring intake

6 Air discharge grille


NOTES
7 Air suction grille
1. Location of nameplate
The indoor unit nameplate is located on the bell mouth inside the suction grille. Drain hose
8 Inner: ·Ø25·
The decoration panel nameplate is located on the inner frame inside the suction grille.
2. When installing a wireless controller, there will be a receiver on this location. For details, see the drawing of the wireless controller.
3. ,IDQ\RIWKHIROORZLQJFRQGLWLRQVDUHPHWDGGLWLRQDOLQVXODWLRQ JODVVZRRORUSRO\HWK\OHQHIRDPWKLFNQHVV•āāPP LVUHTXLUHG Decoration panel
$PELHQWFRQGLWLRQVLQWKHFHLOLQJ•āāƒ&DQGāāUHODWLYHKXPLGLW\ BYFQ60B2W1 WHITE Ral 9010
Fresh air is inducted into the ceiling.
The unit operates continuously. BYFQ60B3W1 WHITE Ral 9010
4. Though the installation is acceptable up to maximum ·660·mm square ceiling opening, keep the clearance of ·45·mm or less
between the indoor unit and the ceiling opening, so that the panel overlap allowance can be ensured. 3D082161C

• VRV Systems • FXZQ-A 11


• Indoor Unit • FXZQ-A

8 Centre of gravity
8-1 Centre of Gravity

12 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

9 Piping diagrams
9-1 Piping Diagrams

• VRV Systems • FXZQ-A 13


• Indoor Unit • FXZQ-A

10 Wiring diagrams
10 - 1 Wiring Diagrams - Single Phase

10

14 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

11 Sound data
11 - 1 Sound Pressure Spectrum

FXZQ15-20A 3
Cooling mode Heating mode

11
Sound pressure level [dB]

Sound pressure level [dB]


Octave band center frequency [Hz] Octave band center frequency [Hz]

Cooling Total db Heating Total dB


LEGEND

dBA = A-weighted sound pressure level (A scale according to IEC). A B C D A B C D


FXZQ/20A2VEB
dBA 33 30 25.5 dBA 33 30 25.5
A Scale
B High NOTES
C Medium
1. Data is valid at free field condition.
D Low
2. Data is valid at nominal operation condition.
3. dBA = A-weighted sound pressure level (A scale according to IEC).
Location of microphone
4. Editable data for this drawing are available in the GDE (E-BOM) system.
5. Sound power [dBA]

P
High 49 dBA

0LQP

3D082566A
FXZQ25A Applicable models
FXZQ25A2VEB
Cooling mode Heating mode
Sound pressure level [dB]

Sound pressure level [dB]

Octave band center frequency [Hz] Octave band center frequency [Hz]

Cooling Total db Heating Total dB


LEGEND

dBA = A-weighted sound pressure level (A scale according to IEC). A B C D A B C D


dBA 33 30 25.5 dBA 33 30 25.5
A Scale
B High NOTES
C Medium
1. Data is valid at free field condition.
D Low
2. Data is valid at nominal operation condition.
3. dBA = A-weighted sound pressure level (A scale according to IEC).
Location of microphone
4. Editable data for this drawing are available in the GDE (E-BOM) system.
5. Sound power [dBA]

P
High 50 dBA

0LQP

3D082567A
• VRV Systems • FXZQ-A 15
• Indoor Unit • FXZQ-A

11 Sound data
11 - 1 Sound Pressure Spectrum

FXZQ32A Applicable models


FXZQ32A2VEB
Cooling mode Heating mode

11
Sound pressure level [dB]

Sound pressure level [dB]


Octave band center frequency [Hz] Octave band center frequency [Hz]

Cooling Total db Heating Total dB


LEGEND

dBA = A-weighted sound pressure level (A scale according to IEC). A B C D A B C D


dBA 33.5 30 26 dBA 33.5 30 26
A Scale
B High NOTES
C Medium
1. Data is valid at free field condition.
D Low
2. Data is valid at nominal operation condition.
3. dBA = A-weighted sound pressure level (A scale according to IEC).
Location of microphone
4. Editable data for this drawing are available in the GDE (E-BOM) system.
5. Sound power [dBA]

P
High 51 dBA

0LQP

3D082568A
FXZQ40A Applicable models
FXZQ40A2VEB
Cooling mode Heating mode
Sound pressure level [dB]

Sound pressure level [dB]

Octave band center frequency [Hz] Octave band center frequency [Hz]

Cooling Total db Heating Total dB


LEGEND

dBA = A-weighted sound pressure level (A scale according to IEC). A B C D A B C D


dBA 37 32 28 dBA 37 32 28
A Scale
B High NOTES
C Medium
1. Data is valid at free field condition.
D Low
2. Data is valid at nominal operation condition.
3. dBA = A-weighted sound pressure level (A scale according to IEC).
Location of microphone
4. Editable data for this drawing are available in the GDE (E-BOM) system.
5. Sound power [dBA]

P
High 54 dBA

0LQP

3D082569A
16 • VRV Systems • FXZQ-A
• Indoor Unit • FXZQ-A

11 Sound data
11 - 1 Sound Pressure Spectrum

FXZQ50A Applicable models


3
FXZQ50A2VEB
Cooling mode Heating mode

11
Sound pressure level [dB]

Sound pressure level [dB]


Octave band center frequency [Hz] Octave band center frequency [Hz]

Cooling Total db Heating Total dB


LEGEND

dBA = A-weighted sound pressure level (A scale according to IEC). A B C D A B C D


dBA 43 40 33 dBA 43 40 33
A Scale
B High NOTES
C Medium
1. Data is valid at free field condition.
D Low
2. Data is valid at nominal operation condition.
3. dBA = A-weighted sound pressure level (A scale according to IEC).
Location of microphone
4. Editable data for this drawing are available in the GDE (E-BOM) system.
5. Sound power [dBA]

P
High 60 dBA

0LQP

3D082570A

• VRV Systems • FXZQ-A 17


• Indoor Unit • FXZQ-A

12 Air flow patterns


12 - 1 Air Flow Pattern - Cooling

FXZQ15A
Cooling air velocity distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

12

Cooling air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083823

FXZQ20A
Cooling air velocity distribution
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

Cooling air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083824

18 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

12 Air flow patterns


12 - 1 Air Flow Pattern - Cooling

FXZQ25A
Cooling air velocity distribution
3
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

12

Cooling air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083825

FXZQ32A
Cooling air velocity distribution
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

Cooling air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083826

• VRV Systems • FXZQ-A 19


• Indoor Unit • FXZQ-A

12 Air flow patterns


12 - 1 Air Flow Pattern - Cooling

FXZQ40A
Cooling air velocity distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

12

Cooling air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083827

FXZQ50A
Cooling air velocity distribution
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

Cooling air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083828

20 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

12 Air flow patterns


12 - 2 Air Flow Pattern - Heating

FXZQ15A
Heating air velocity distribution
3
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

12

Heating air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083833

FXZQ20A
Heating air velocity distribution
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

Heating air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083834

• VRV Systems • FXZQ-A 21


• Indoor Unit • FXZQ-A

12 Air flow patterns


12 - 2 Air Flow Pattern - Heating

FXZQ25A
Heating air velocity distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

12

Heating air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083835

FXZQ32A
Heating air velocity distribution
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

Heating air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083836

22 • VRV Systems • FXZQ-A


• Indoor Unit • FXZQ-A

12 Air flow patterns


12 - 2 Air Flow Pattern - Heating

FXZQ40A
Heating air velocity distribution
3
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

12

Heating air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083837

FXZQ50A
Heating air velocity distribution
$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

Heating air temperature distribution

$OOURXQGDLUGLVFKDUJHDLUÀRZGLUHFWLRQKRUL]RQWDO

4D083838

• VRV Systems • FXZQ-A 23


Daikin Europe N.V. Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

EEDEN19 12/19
The present leaflet is drawn up by way of information only and does not constitute an offer binding
upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its
knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fit-
ness for particular purpose of its content and the products and services presented therein. Specifica-
tions are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for
any direct or indirect damage, in the broadest sense, arising from or related to the use and/or inter-
pretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

You might also like