Timer Unit: Type 1078-2
Timer Unit: Type 1078-2
Timer Unit: Type 1078-2
Advantages/Benefits
8 functions
3 reset functions
Protection against
unauthorised changes of
times and functions
Design/Function Applications
The timer unit Type 1078-2 can be The required switching functions and • Repeated valve timing
fitted to all valves with the cable response times can simply be control
plug to DIN 43 650. This standard, adjusted by means of two function • Irrigation systems
developed by Bürkert, is used keys. • Condensate drain of
internationally. compressors and pipeline
If other 1078-2 timer units are to be systems
The timer unit is micro-processor programmed at the same time with • Repeated timing control
operated. The device is mainly the same data, the unit can simply of unsupervised processes
used in applications where times be re-inserted, and the data trans- • Cost-effective alternative to
and functions are frequently mitted via a keystroke. The timer relays or PLC's for repeated
changed or where highly precise units have now been programmed valve operation
response times are required. with specific times and are protected
against unauthorised changes.
The timer can easily be program-
med or re-programmed in situ via When fitted the control unit provides
the control unit Type 1077-2. a continuous readout of the function
and response times programmed.
Technical Data
Poles 2-pole and earth When delivered, the timer unit Type 1078-2 does not
include the control unit Type 1077-2
Outlet connector pin standard to
DIN 43 650 The timers can be pre-set if required.
Rating IP 65
air gaps and leakage paths
to VDE 0100
Dimensions 32 x 90 x 41,5 mm
Weight approx. 50 g
The LED display is not visible when the control unit Type
1077-2 is fitted.
Timer Unit Type 1078-2
Functions
OFF
AUS
t
Signal:
Inverted cycler:
The circuit function of the cycler is reversed i.e.
“Inverted cycler” begins with toff.
Switch-on impulse
Once energized, the connected valve is
operated for the preset time (ton). Then the
valve switches off until it is energized again.
Switch-on delay
Once energized, the connected valve is operated
for the preset time (ton). Then the valve switches off
until it is energized again.
Dimensions in mm
Gasket 1.5
Voltage Order-No.
In case of special requirements We reserve the right to make technical 710-GB/ 2-0130