Professional Documents
Culture Documents
Microbiology Lab Equipment
Microbiology Lab Equipment
MICROBIOLOGY LABORATORY
The Microbiology & Molecular Biology laboratory has facilities to work with different types
of biological samples for clinical, microbiological and genetic studies.
It has three main areas: Conventional Microbiology, Clinics, and Molecular Biology.
In the microbiology area, researchers can isolate microorganisms such as fungi and bacteria
from different kind of samples. In the clinic area, investigators can process blood samples,
feces, urine and organs from various animal species and humans for research or health
purposes. Finally, in the Molecular Biology area, scientists can extract DNA or RNA from a
variety of samples (biological, environmental, etc.). In addition, they can perform basic
molecular techniques such as polymerase chain reaction (PCR).
Equipment Catalog
Allows obtaining DI
water from potable
Water Distiller 1 water-extracting
metals and ions
from it.
Incubation of
microbiological
cultures and
Incubator 2
different kind of
samples from 20° C
to 50° C.
1|Page
Seals
Quantity Tray microbiological
1
Sealer water samples for
Colillert Kits.
Allows measuring
samples and
Analytical
1 materials with a
balance
precision of 5
digits.
Regulate incubation
Sand Bath 1 of samples until
400°C.
Incubation of
samples for DNA
Block heater 1 and RNA extraction
from 5°C
to 130°C.
2|Page
8 units
(2 from 100 to
1000 ul) Measure different
(2 from 0.5 to 10 volumes of samples
Micropipettes ul) or solutions
(2 from 20 to 200 from 0 ul through
ul) 1000 ul.
(2 from 2 to 20 ul)
Allows
Electrophoresis electrophoretic
chamber and 1 separation of DNA
Power supply or RNA for its
visualization.
3|Page
Gel Visualization of
Documentation DNA
1
System or RNA after
BIO-RAD electrophoresis.
Measures the
NanoDrop 2000 1 concentration and
quality of DNA.
Measures DNA
Qubit concentration and
1
Fluorimeter quality for
sequencing.
4|Page
Performs as a
spectrophotometer,
which measures
intensity as a
Microplate function of the color
1
reader ELX808 or more specifically
the wavelength of
light. Principally for
ELISAs.
3units
(1 for tubes from Allows separation
Centrifuge 5ml trough 50 ml) of samples due to
(2 for tubes of centipede force.
1.5ml)
Disrupts material
Mini Bead
1 for DNA or RNA
Beater
extraction.
Prevents
cross-contamination
DNA Carry
inside the working
over Blocking 1
chamber that is used
Cabinet
to prepare PCR
Mater mix.
5|Page
Incubation of
Water Bath
1 samples from 25°C
GEMMY
to 90° C.
Provides
Biological environmental and
Safety Cabinet 1 personnel protection
IIAZ for performing
biological cultures.
6|Page
Amplifies DNA
Thermal Cycler
1 and RNA due to
Biometra
PCR reaction.
Electric device
used to measure
pH Metter hydrogen-ion
1
Toledo activity (acidity
or alkalinity)
in solution.
Allows
homogenization of
Tissue
1 various materials
homogenizer
such as tissue, plant,
food, soil, etc.
7|Page
Limits exposure
to hazardous or
Fume hood 1
toxic fumes,
vapors or dust.
Spectrophotometer
that determines
biological
Vet Test 8008 metabolite values
1
IDEXX like glucose,
creatinine, urea, etc.
Exclusively for
veterinary use.
8|Page