Rail Access Road Hardstand Detail Sections

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 21

CS075481/BPDG/1.

0 Appendix C/ – Standard
March 2015
Details

Appendix C – Standard Details


GENERAL NOTES:
152x152x37 UC POSTS WITH SPECIFICATION:
6000 POINTED TOP ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE
MAX 155 PALISADE FENCING SPECIFIED.
CENTRES GATE FRAME 90x50x3.5 RHS
ALL STEEL PALISADE FENCE SHALL BE SECURITY TYPE GP18 IN ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH
ACCORDANCE WITH BS 1722 : PART 12 AND HOT DIP GALVANISED IN THE REQUIREMENTS OF NETWORK RAIL COMPANY
ANTILIFT GATE HANGING ACCORDANCE WITH BS EN ISO 1461. PROCEDURES
DETAIL NR/SP/OHS/011: PREVENTION OF DAMAGE TO AND
ALL ROLLED STEEL SECTIONS SHALL BE OF STEEL GRADE S275 TO DANGER FROM SURFACE AND BURIED SERVICES.
SLIDING LOCKING BAR
1800

BS EN 10025 : 1993 UNLESS OTHERWISE SPECIFIED. NR/PRC/MPI/CI0024: CONTROL AND USE OF METAL
6mm THK SLAM PLATE PINS AND SPIKES ON NETWORK RAIL
TRIANGULAR GUSSET PLATE ALL BOLTS SHALL COMPLY WITH BS 3692 AND SHALL BE STRENGTH INFRASTRUCTURE
GROUND GRADE 8.8. NUTS SHALL BE STRENGTH GRADE 8 AND WASHERS NR/PRC/MPI/CIOO26 PROCESS: FOR LOCATING
LEVEL SHALL CONFORM TO BS 4320. ALL BOLTS, NUTS AND WASHERS BURIED SERVICES PRIOR TO GROUND PENETRATION.
SHALL BE ZINC COATED.
FENCES JOINED TO EXISTING FENCES, WALLS OR OTHER
525mm MINIMUM EMBEDMENT
DROP BOLT ALL CONNECTIONS SHALL BE BOLTED IN ACCORDANCE WITH BS 1722 STRUCTURES TO PROVIDE A COMPLETE BARRIER TO
INTO 600x600x1100mm
: PART 12. PERSONS OR ANIMALS AS APPROPRIATE.
1100

300
CONCRETE FOOTING
600 OPTIONAL ITEMS REQUIRED FOR ADDITIONAL SECURITY ARE TO BE FENCES SHALL BE ACCURATELY SET OUT AND ERECTED
SPECIFIED IN A PROJECT SPECIFIC FORM A/B TO PROVIDE A SMOOTH ALIGNMENT IN PLAN AND
ELEVATION, FOLLOWING THE CONTOURS OF THE GROUND
ALL BEDDING CONCRETE FOR VERTICAL FENCE POSTS TO BE MASS AS CLOSELY AS IS PRACTICABLE.
TYPICAL 1.8m HIGH 6m WIDE PALISADE GATE (1:50) CONCRETE MINIMUM GRADE ST2 TO BS 8500-1.
(TYPICAL EXTERNAL VIEW) THE LINE OF THE FENCING SHALL BE CLEARED OF ALL
INSTALLATION GUIDANCE: PALISADE FENCING IMPENDING VEGETATION AND TRIMMED TO REMOVE ANY
IRREGULARITIES TO ENABLE FENCE INFILL PANELS TO BE
TO LIMIT DEFLECTION IN FENCE RAILS, THE BOTTOM HORIZONTAL ERECTED AT A CONSTANT DISTANCE FROM THE GROUND.
RAIL SHALL BE SUPPORTED SO THAT AFTER TIGHTENING OF THE
102x44x7.5 RSJ WITH POINTED BOLTS, ALIGNING AND PLUMBING TO THE FENCE THERE IS A SLIGHT
2750
MAX 155 TOP UPWARD CAMBER. THIS SUPPORT SHOULD BE REMOVED ONLY ONCE
THE CONCRETE HAS SET.
102x44x7.5 RSJ CENTRES 40x40x6 RSA RAILS TOP AND
A BOTTOM CONCRETE
40x40x6 RSA RAIL
CONCRETE: C30/37, AC-4, DC-4, AGGREGATE: 20mm (MAX.)
3.0mm THICK CORRUGATED MINIMUM 3.0mm THICK x 70mm SULPHATE AND CHLORIDE RESISTANT 17.12.
PALES FIXED TO RAILS AT WIDE CORRUGATED 'W' 01 P.J. FIRST ISSUE S.C.
225

225

DISTANCE TO COAST: 2km, SITE ALTITUDE: 100m AMSL 2014


155mm CENTRES FENCING PALES AT EQUAL WIND SPEED: 25m/s, ENVIRONMENT: TYPICAL OPEN COUNTRYSIDE
1800

1800

CENTRES, WITH TRIPLE GROUND CONDITION: AVERAGE FOR PLANTED (ROOT) FOUNDATION Rev Date Name Description of Revisions
Rev'
Check
POINTED TOPS WITH SPLAYED WATER TABLE: WELL BELOW THE FOUNDATION, AND SITE IS NOT Client
40x40x6 RSA RAIL HEADS POINTING OUTWARDS SUSCEPTIBLE TO FLOODING
100

100

GROUND GROUND TABLE 1


LEVEL LEVEL
SAFETY, HEALTH & ENVIRONMENT RISK ASSESSMENT
525mm MINIMUM EMBEDMENT
525
50 MAX.

50 MAX.

INTO 600x600x1100mm DESIGNERS' NOTE - CDM REG. 13(2)(b)


1100

CONCRETE FOOTING
THE FOLLOWING ARE SIGNIFICANT HAZARDS WHICH MIGHT AFFECT THE HEALTH
600 AND SAFETY OF THOSE UNDERTAKING THE WORKS OUTLINED IN THIS SET OF
A DRAWINGS ON RAILWAY STRUCTURES OR THOSE AFFECTED BY THESE Property and infrastructure
ACTIVITIES. A SITE SPECIFIC RISK ASSESSMENT SHOULD ALWAYS BE Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
UNDERTAKEN PRIOR TO COMMENCING ANY OF THE WORKS DESCRIBED ON SITE.
SECTION A-A (1:50) TYPICAL 1.8m HIGH PALISADE FENCE (1:50) IT IS ASSUMED THAT A COMPETENT CONTRACTOR IS AWARE OF THE RISKS
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.


(TYPICAL EXTERNAL VIEW) ASSOCIATED WITH GENERAL CONSTRUCTION ACTIVITIES UNDERTAKEN WITHIN
THE RAILWAY ENVIRONMENT. Project Title
INFRASTRUCTURE ACCESS POINTS
RISK STAGE
BEST PRACTICE DESIGN GUIDE
CONTACT WITH OVERHEAD
SPECIFIC METHOD STATEMENT AND RISK STANDARD DETAILS
C ASSESSMENT TO IDENTIFY AND DETAIL
WIRES OR BURIED SERVICES PROTECTION TO ALL SERVICES, BURIED Drawing Title
AND OVERHEAD.

DAMAGE TO ROOTS OR SPECIFIC METHOD STATEMENT TO DETAIL 1.8m HIGH 6m WIDE PALISADE
PROTECTED TREES C PROVISION FOR ROOT PROTECTION OF
TREES DURING WORKS. GATE & FENCE DETAILS -
INJURY TO ADJOINING
SECURITY LEVEL 1 & 2
ADJOINING LANDOWNERS TO BE
LANDOWNERS C INFORMED AHEAD OF WORKS.
Drawn By Name Sig. Date
P.JENYON 17.12.14
FAILURE OF FENCE DUE TO CERTIFICATE OF CONFORMITY IN Checked By Name Sig. Date
S.CHAMBERS 17.12.14
SUB-STANDARD MATERIALS D/C ACCORDANCE WITH BS 1722 TO BE
Approved By Name Sig. Date
PROVIDED BY FENCE MANUFACTURER. J.SHERIDAN 17.12.14
Scale Sheet of
AS SHOWN @ A3 1 1
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER FAILURE OF FENCE DUE TO D/C CERTIFICATE OF CONFORMITY IN Site Coordinates ELR Chainage

Signature: Title: SUB-STANDARD INSTALLATION ACCORDANCE WITH BS 1722 TO BE N/A N/A N/A
PROVIDED BY FENCE INSTALLER. Drawing No. Revision
Name: Date:
NOTE : C=CONSTRUCTION, D=DESIGN 075481/CV/001 01
GENERAL NOTES:
SPECIFICATION:
203x203x60 UC POSTS WITH ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE
6000 POINTED TOP PALISADE FENCING SPECIFIED.
MAX 155
CENTRES GATE FRAME 100x60x5.0 RHS ALL STEEL PALISADE FENCE SHALL BE SECURITY TYPE SP30 IN ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH
ACCORDANCE WITH BS 1722 : PART 12 AND HOT DIP GALVANISED IN THE REQUIREMENTS OF NETWORK RAIL COMPANY
ACCORDANCE WITH BS EN ISO 1461. PROCEDURES
NR/SP/OHS/011: PREVENTION OF DAMAGE TO AND
ALL ROLLED STEEL SECTIONS SHALL BE OF STEEL GRADE S275 TO DANGER FROM SURFACE AND BURIED SERVICES.
ANTILIFT GATE HANGING BS EN 10025 : 1993 UNLESS OTHERWISE SPECIFIED. NR/PRC/MPI/CI0024: CONTROL AND USE OF METAL
DETAIL PINS AND SPIKES ON NETWORK RAIL
ALL BOLTS SHALL COMPLY WITH BS 3692 AND SHALL BE STRENGTH INFRASTRUCTURE
SLIDING LOCKING BAR GRADE 8.8. NUTS SHALL BE STRENGTH GRADE 8 AND WASHERS NR/PRC/MPI/CIOO26 PROCESS: FOR LOCATING
3000

SHALL CONFORM TO BS 4320. ALL BOLTS, NUTS AND WASHERS BURIED SERVICES PRIOR TO GROUND
6mm THK SLAM PLATE SHALL BE ZINC COATED. PENETRATION.

ALL CONNECTIONS SHALL BE BOLTED IN ACCORDANCE WITH BS 1722 FENCES JOINED TO EXISTING FENCES, WALLS OR OTHER
: PART 12. STRUCTURES TO PROVIDE A COMPLETE BARRIER TO
TRIANGULAR GUSSET PLATE
PERSONS OR ANIMALS AS APPROPRIATE.
OPTIONAL ITEMS REQUIRED FOR ADDITIONAL SECURITY ARE TO BE
GROUND 300x300mm INSITU CONCRETE SPECIFIED IN A PROJECT SPECIFIC FORM A/B FENCES SHALL BE ACCURATELY SET OUT AND ERECTED
LEVEL SILL. MIX ST2 TO PROVIDE A SMOOTH ALIGNMENT IN PLAN AND
ALL BEDDING CONCRETE FOR VERTICAL FENCE POSTS TO BE MASS ELEVATION, FOLLOWING THE CONTOURS OF THE GROUND
CONCRETE MINIMUM GRADE ST2 TO BS 8500-1. AS CLOSELY AS IS PRACTICABLE.

100 DIA DUCT FOR EARTHING INSTALLATION GUIDANCE: PALISADE FENCING THE LINE OF THE FENCING SHALL BE CLEARED OF ALL
300

DROP BOLT
1300

TAPE ON INSIDE OF COMPOUND IMPENDING VEGETATION AND TRIMMED TO REMOVE ANY


TO LIMIT DEFLECTION IN FENCE RAILS, THE BOTTOM HORIZONTAL IRREGULARITIES TO ENABLE FENCE INFILL PANELS TO BE
RAIL SHALL BE SUPPORTED SO THAT AFTER TIGHTENING OF THE ERECTED AT A CONSTANT DISTANCE FROM THE GROUND.
925mm MINIMUM EMBEDMENT BOLTS, ALIGNING AND PLUMBING TO THE FENCE THERE IS A SLIGHT
INTO 900x900x1300mm UPWARD CAMBER. THIS SUPPORT SHOULD BE REMOVED ONLY ONCE
CONCRETE FOOTING THE CONCRETE HAS SET.
900
CONCRETE
TYPICAL 3.0m HIGH 6m WIDE PALISADE GATE (1:50) CONCRETE: C30/37, AC-4, DC-4, AGGREGATE: 20mm (MAX.)
(TYPICAL EXTERNAL VIEW) SULPHATE AND CHLORIDE RESISTANT 17.12.
01 P.J. FIRST ISSUE S.C.
DISTANCE TO COAST: 2km, SITE ALTITUDE: 100m AMSL 2014
WIND SPEED: 25m/s, ENVIRONMENT: TYPICAL OPEN COUNTRYSIDE
Rev'
GROUND CONDITION: AVERAGE FOR PLANTED (ROOT) FOUNDATION Rev Date Name Description of Revisions
Check

WATER TABLE: WELL BELOW THE FOUNDATION, AND SITE IS NOT Client
2750 127x76x13 UB POSTS WITH
MAX 155 SUSCEPTIBLE TO FLOODING
127x76x13 UB POINTED TOP
CENTRES A TABLE 1
50x50x6 RSA RAIL 50x50x6 RSA RAILS TOP AND
SAFETY, HEALTH & ENVIRONMENT RISK ASSESSMENT
475

475

BOTTOM
DESIGNERS' NOTE - CDM REG. 13(2)(b)
MINIMUM 3.0mm THICK x 70mm
THE FOLLOWING ARE SIGNIFICANT HAZARDS WHICH MIGHT AFFECT THE HEALTH
3.0mm THICK CORRUGATED WIDE CORRUGATED 'W'
AND SAFETY OF THOSE UNDERTAKING THE WORKS OUTLINED IN THIS SET OF
PALES FIXED TO RAILS AT FENCING PALES AT EQUAL
DRAWINGS ON RAILWAY STRUCTURES OR THOSE AFFECTED BY THESE Property and infrastructure
155mm CENTRES CENTRES, WITH TRIPLE
ACTIVITIES. A SITE SPECIFIC RISK ASSESSMENT SHOULD ALWAYS BE Special Projects, 2nd Floor Clemence House, Mellor Road,
3000

POINTED TOPS WITH SPLAYED Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
UNDERTAKEN PRIOR TO COMMENCING ANY OF THE WORKS DESCRIBED ON SITE.
HEADS POINTING OUTWARDS
3000

T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk


IT IS ASSUMED THAT A COMPETENT CONTRACTOR IS AWARE OF THE RISKS Capita Property and Infrastructure Ltd.
ASSOCIATED WITH GENERAL CONSTRUCTION ACTIVITIES UNDERTAKEN WITHIN
50x50x6 RSA RAILS 300x300mm INSITU CONCRETE THE RAILWAY ENVIRONMENT. Project Title
380

SILL. MIX ST2 INFRASTRUCTURE ACCESS POINTS


100

RISK STAGE
GROUND GROUND BEST PRACTICE DESIGN GUIDE
LEVEL LEVEL SPECIFIC METHOD STATEMENT AND RISK STANDARD DETAILS
CONTACT WITH OVERHEAD ASSESSMENT TO IDENTIFY AND DETAIL
WIRES OR BURIED SERVICES C
PROTECTION TO ALL SERVICES, BURIED Drawing Title
50 MAX.

AND OVERHEAD.
925

925mm MINIMUM ENBEDMENT


100
50
1300

INTO 600x600x1300mm DAMAGE TO ROOTS OR SPECIFIC METHOD STATEMENT TO DETAIL 3.0m HIGH 6m WIDE PALISADE
CONCRETE FOOTING PROTECTED TREES C PROVISION FOR ROOT PROTECTION OF
600 A INTERMEDIATE SUPPORTS TREES DURING WORKS. GATE & FENCE DETAILS -
WITH 100mm EMBEDMENT
INJURY TO ADJOINING
SECURITY LEVEL 3
INTO CONCRETE SILL ADJOINING LANDOWNERS TO BE
LANDOWNERS C INFORMED AHEAD OF WORKS.
SECTION A-A (1:50) TYPICAL 3m HIGH PALISADE FENCE (1:50)
Drawn By Name
P.JENYON
Sig. Date
17.12.14
FAILURE OF FENCE DUE TO CERTIFICATE OF CONFORMITY IN Checked By Name Sig. Date
(TYPICAL EXTERNAL VIEW) S.CHAMBERS 17.12.14
SUB-STANDARD MATERIALS D/C ACCORDANCE WITH BS 1722 TO BE
Approved By Name Sig. Date
PROVIDED BY FENCE MANUFACTURER. J.SHERIDAN 17.12.14
Scale Sheet of
AS SHOWN @ A3 1 1
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER FAILURE OF FENCE DUE TO D/C CERTIFICATE OF CONFORMITY IN Site Coordinates ELR Chainage

Signature: Title: SUB-STANDARD INSTALLATION ACCORDANCE WITH BS 1722 TO BE N/A N/A N/A
PROVIDED BY FENCE INSTALLER. Drawing No. Revision
Name: Date:
NOTE : C=CONSTRUCTION, D=DESIGN 075481/CV/002 01
GENERAL NOTES:
SPECIFICATION:
ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE
152x152x37 UC POSTS WITH PALISADE FENCING SPECIFIED.
1500 POINTED TOP
MAX 155
CENTRES ALL STEEL PALISADE FENCE SHALL BE SECURITY TYPE GP18/SP30 IN ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH
GATE FRAME 90x50x3.6 RHS ACCORDANCE WITH BS 1722 : PART 12 AND HOT DIP GALVANISED IN THE REQUIREMENTS OF NETWORK RAIL COMPANY
ACCORDANCE WITH BS EN ISO 1461. PROCEDURES
NR/SP/OHS/011: PREVENTION OF DAMAGE TO AND
ALL ROLLED STEEL SECTIONS SHALL BE OF STEEL GRADE S275 TO DANGER FROM SURFACE AND BURIED SERVICES.
BS EN 10025 : 1993 UNLESS OTHERWISE SPECIFIED. NR/PRC/MPI/CI0024: CONTROL AND USE OF METAL
ANTILIFT GATE HANGING DETAIL PINS AND SPIKES ON NETWORK RAIL
ALL BOLTS SHALL COMPLY WITH BS 3692 AND SHALL BE STRENGTH INFRASTRUCTURE
GRADE 8.8. NUTS SHALL BE STRENGTH GRADE 8 AND WASHERS NR/PRC/MPI/CIOO26 PROCESS: FOR LOCATING
SLIDING LOCKING BAR SHALL CONFORM TO BS 4320. ALL BOLTS, NUTS AND WASHERS BURIED SERVICES PRIOR TO GROUND PENETRATION.
3000

SHALL BE ZINC COATED.


FENCES JOINED TO EXISTING FENCES, WALLS OR OTHER
ALL CONNECTIONS SHALL BE BOLTED IN ACCORDANCE WITH BS 1722 STRUCTURES TO PROVIDE A COMPLETE BARRIER TO
6mm THK SLAM PLATE : PART 12. PERSONS OR ANIMALS AS APPROPRIATE.
TRIANGULAR GUSSET PLATE
OPTIONAL ITEMS REQUIRED FOR ADDITIONAL SECURITY ARE TO BE FENCES SHALL BE ACCURATELY SET OUT AND ERECTED
SPECIFIED IN A PROJECT SPECIFIC FORM A/B TO PROVIDE A SMOOTH ALIGNMENT IN PLAN AND
GROUND 300x300mm INSITU CONCRETE ELEVATION, FOLLOWING THE CONTOURS OF THE GROUND
LEVEL SILL. MIX ST2 ALL BEDDING CONCRETE FOR VERTICAL FENCE POSTS TO BE MASS AS CLOSELY AS IS PRACTICABLE.
CONCRETE MINIMUM GRADE ST2 TO BS 8500-1.
THE LINE OF THE FENCING SHALL BE CLEARED OF ALL
INSTALLATION GUIDANCE: PALISADE FENCING IMPENDING VEGETATION AND TRIMMED TO REMOVE ANY
100 DIA DUCT FOR EARTHING IRREGULARITIES TO ENABLE FENCE INFILL PANELS TO BE
300
1300

TAPE ON INSIDE OF COMPOUND TO LIMIT DEFLECTION IN FENCE RAILS, THE BOTTOM HORIZONTAL ERECTED AT A CONSTANT DISTANCE FROM THE GROUND.
RAIL SHALL BE SUPPORTED SO THAT AFTER TIGHTENING OF THE
925mm MINIMUM EMBEDMENT BOLTS, ALIGNING AND PLUMBING TO THE FENCE THERE IS A SLIGHT
600 UPWARD CAMBER. THIS SUPPORT SHOULD BE REMOVED ONLY ONCE
INTO 600x600x1300mm
CONCRETE FOOTING THE CONCRETE HAS SET.

CONCRETE
TYPICAL 3.0m HIGH 1.5m WIDE PALISADE CONCRETE: C30/37, AC-4, DC-4, AGGREGATE: 20mm (MAX.)
GATE (1:50) SULPHATE AND CHLORIDE RESISTANT
DISTANCE TO COAST: 2km, SITE ALTITUDE: 100m AMSL
01
17.12.
2014 P.J. FIRST ISSUE S.C.
(TYPICAL EXTERNAL VIEW) WIND SPEED: 25m/s, ENVIRONMENT: TYPICAL OPEN COUNTRYSIDE
Rev'
GROUND CONDITION: AVERAGE FOR PLANTED (ROOT) FOUNDATION Rev Date Name Description of Revisions
Check

WATER TABLE: WELL BELOW THE FOUNDATION, AND SITE IS NOT Client
SUSCEPTIBLE TO FLOODING

TABLE 1

SAFETY, HEALTH & ENVIRONMENT RISK ASSESSMENT

178x102x19 UB POSTS WITH DESIGNERS' NOTE - CDM REG. 13(2)(b)


1500 POINTED TOP
MAX 155
THE FOLLOWING ARE SIGNIFICANT HAZARDS WHICH MIGHT AFFECT THE HEALTH
CENTRES
AND SAFETY OF THOSE UNDERTAKING THE WORKS OUTLINED IN THIS SET OF
GATE FRAME 90x50x3.6 RHS
DRAWINGS ON RAILWAY STRUCTURES OR THOSE AFFECTED BY THESE Property and infrastructure
ANTILIFT GATE HANGING DETAIL ACTIVITIES. A SITE SPECIFIC RISK ASSESSMENT SHOULD ALWAYS BE Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
UNDERTAKEN PRIOR TO COMMENCING ANY OF THE WORKS DESCRIBED ON SITE.
SLIDING LOCKING BAR T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
IT IS ASSUMED THAT A COMPETENT CONTRACTOR IS AWARE OF THE RISKS
1800

Capita Property and Infrastructure Ltd.


6mm THK SLAM PLATE ASSOCIATED WITH GENERAL CONSTRUCTION ACTIVITIES UNDERTAKEN WITHIN
THE RAILWAY ENVIRONMENT. Project Title

TRIANGULAR GUSSET PLATE INFRASTRUCTURE ACCESS POINTS


GROUND RISK STAGE
LEVEL
BEST PRACTICE DESIGN GUIDE
CONTACT WITH OVERHEAD
SPECIFIC METHOD STATEMENT AND RISK STANDARD DETAILS
C ASSESSMENT TO IDENTIFY AND DETAIL
WIRES OR BURIED SERVICES PROTECTION TO ALL SERVICES, BURIED
525mm MINIMUM EMBEDMENT Drawing Title
1100

INTO 600x600x1100mm AND OVERHEAD.


CONCRETE FOOTING DAMAGE TO ROOTS OR
600 SPECIFIC METHOD STATEMENT TO DETAIL 3.0m & 1.8m HIGH 1.5m WIDE
PROTECTED TREES C PROVISION FOR ROOT PROTECTION OF
TREES DURING WORKS. PALISADE ACCESS GATE DETAILS

TYPICAL 1.8m HIGH 1.5m WIDE PALISADE INJURY TO ADJOINING


LANDOWNERS C
ADJOINING LANDOWNERS TO BE
INFORMED AHEAD OF WORKS.
GATE (1:50) Drawn By Name
P.JENYON
Sig. Date
17.12.14
FAILURE OF FENCE DUE TO CERTIFICATE OF CONFORMITY IN Checked By Name Sig. Date
(TYPICAL EXTERNAL VIEW) S.CHAMBERS 17.12.14
SUB-STANDARD MATERIALS D/C ACCORDANCE WITH BS 1722 TO BE
Approved By Name Sig. Date
PROVIDED BY FENCE MANUFACTURER. J.SHERIDAN 17.12.14
Scale Sheet of
AS SHOWN @ A3 1 1
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER FAILURE OF FENCE DUE TO D/C CERTIFICATE OF CONFORMITY IN Site Coordinates ELR Chainage

Signature: Title: SUB-STANDARD INSTALLATION ACCORDANCE WITH BS 1722 TO BE N/A N/A N/A
PROVIDED BY FENCE INSTALLER. Drawing No. Revision
Name: Date:
NOTE : C=CONSTRUCTION, D=DESIGN 075481/CV/003 01
GENERAL NOTES:
5. THE VERTICAL EDGE OF THE CONCRETE 1. ALL DIMENSIONS IN MILLIMETRES UNLESS NOTED
FOUNDATION SHALL BE FORMED TO A CLASS F2 OTHERWISE.
6m LIGHTING 8m LIGHTING FINISH IN ACCORDANCE WITH SECTION 80 CLAUSE
80.033 OF THE SPECIFICATION. THE TOP OF THE 2. DO NOT SCALE THIS DRAWING.
FOUNDATION SHALL HAVE A SWEPT BRUSH FINISH
A A B B
WITH FLOATED EDGES, 100mm WIDE. 3. GROUND UNDER CONCRETE FOUNDATION TO BE
WELL COMPACTED PRIOR TO LAYING CONCRETE.
6. THE TOP SURFACE OF THE FOUNDATIONS SHALL ANY SOFT SPOTS TO BE EXCAVATED OUT AND
BE SET TO LEVEL WITH A TOLERANCE OF +/- 5mm. BACKFILLED WITH TYPE 1 FILL WELL COMPACTED IN
DUCT DUCT
PLAN (1:20) PLAN (1:20) NO POINT SHALL HAVE A SAG GREATER THAN 3mm
FROM A 2m STRAIGHT EDGE.
150MM LAYERS.

NOTE: LIGHTING POSITION MAY VARY 4. CONCRETE TO BE DESIGNED MIX IN ACCORDANCE


TO SUIT SITE LOCATION 7. REFER TO ABACUS DRAWINGS FOR DETAILS WITH BS8500-2.
COMPRESSIVE STRENGTH CLASS C32/40
DESIGN CHEMICAL CLASS DC-2Z
HINGED COLUMN TO BE INSTALLED 8. FOR FURTHER DETAILS OF CIVIL ENGINEERING MAX. AGGREGATE SIZE 20mm
TO FALL AWAY FROM TRACK FOR WORKS REFER TO :- NR/L3/CIV/140-MODEL CHLORIDE CLASS CI 0.40
MAINTENANCE PURPOSES. CLAUSES. FOR FURTHER DETAILS OF TECHNICAL CONSISTENCE CLASS S3
APPROVAL OF DESIGN, CONSTRUCTION & CONCRETE BLINDING TO BE DESIGNATED MIX GEN 1
MAINTENANCE OF CIVIL ENGINEERING IN ACCORDANCE WITH BS 8500-2.
INFRASTRUCTURE REFER TO :- NR/SP/CIV/003. REINFORCEMENT TO BE GRADE 500 BAR IN
4910

6880
ACCORDANCE WITH BS4449, OR MESH FABRIC IN
ACCORDANCE WITH BS4483.
COVER TO ALL REINFORCEMENT TO BE 50MM.
MASS CONCRETE FILL TO BASE TO BE
COMPRESSIVE STRENGTH CLASS C16/20.

APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER


Signature: Title:
Name: Date:

6m LIGHTING 8m LIGHTING

17.12.
01 P.J. FIRST ISSUE S.C.
2014
1000

1000
Rev'
Rev Date Name Description of Revisions
Check

Client

GROUND GROUND
LEVEL LEVEL

Property and infrastructure


500

500
Special Projects, 2nd Floor Clemence House, Mellor Road,
1000

Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure


1250

CABLE ENTRY (150X50) CABLE ENTRY (150X50) T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.


1200
1450

Project Title
MASS CONCRETE FOUNDATION GRADE MASS CONCRETE FOUNDATION GRADE INFRASTRUCTURE ACCESS POINTS
ST2. CONCRETE TO BE RAMMED AS ST2. CONCRETE TO BE RAMMED AS
FILLING PROCEEDS. FILLING PROCEEDS.
BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title

WITH CONCRETE ON 25mm


SAND BLINDING 6m & 8m LIGHT DUTY HINGED LIGHTING
300
WITH CONCRETE ON 25mm COLUMN FOUNDATION DETAILS
SAND BLINDING
300
SECTION A-A (1:20) SECTION B-B (1:20)
Drawn By Name
P.JENYON
Sig. Date
17.12.14
Checked By Name Sig. Date
S.CHAMBERS 17.12.14

TYPICAL 6m ABACUS T061RLS LIGHT Approved By Name Sig. Date

TYPICAL 8m ABACUS T081RLS LIGHT J.SHERIDAN


Sheet of
17.12.14
AS SHOWN @ A3 1 1
DUTY LIGHTING COLUMN DUTY LIGHTING COLUMN Site Coordinates
N/A
ELR
N/A
Chainage
N/A
FOUNDATION DETAILS FOUNDATION DETAILS Drawing No. Revision

075481/CV/004 01
NOTES:
5. THE VERTICAL EDGE OF THE CONCRETE 1. ALL DIMENSIONS IN MILLIMETRES UNLESS NOTED
FOUNDATION SHALL BE FORMED TO A CLASS F2 OTHERWISE.
6m LIGHTING FINISH IN ACCORDANCE WITH SECTION 80 CLAUSE
COLUMN 80.033 OF THE SPECIFICATION. THE TOP OF THE 2. DO NOT SCALE THIS DRAWING.
8m LIGHTING
FOUNDATION SHALL HAVE A SWEPT BRUSH FINISH
COLUMN
WITH FLOATED EDGES, 100mm WIDE. 3. GROUND UNDER CONCRETE FOUNDATION TO BE
A A B B WELL COMPACTED PRIOR TO LAYING CONCRETE.
6. THE TOP SURFACE OF THE FOUNDATIONS SHALL ANY SOFT SPOTS TO BE EXCAVATED OUT AND
BE SET TO LEVEL WITH A TOLERANCE OF +/- 5mm. BACKFILLED WITH TYPE 1 FILL WELL COMPACTED IN
NO POINT SHALL HAVE A SAG GREATER THAN 3mm 150MM LAYERS.
RIGID DUCT DUCT FROM A 2m STRAIGHT EDGE.
PLAN (1:25) PLAN (1:25) 7. REFER TO ABACUS DRAWINGS FOR DETAILS
4. CONCRETE TO BE DESIGNED MIX IN ACCORDANCE
WITH BS8500-2.
COMPRESSIVE STRENGTH CLASS C32/40
DESIGN CHEMICAL CLASS DC-2Z
8. FOR FURTHER DETAILS OF CIVIL ENGINEERING MAX. AGGREGATE SIZE 20mm
WORKS REFER TO :- NR/L3/CIV/140-MODEL CHLORIDE CLASS CI 0.40
2370

3175
CLAUSES. FOR FURTHER DETAILS OF TECHNICAL CONSISTENCE CLASS S3
APPROVAL OF DESIGN, CONSTRUCTION & CONCRETE BLINDING TO BE DESIGNATED MIX GEN 1
NOTE: LIGHTING POSITION MAY VARY MAINTENANCE OF CIVIL ENGINEERING IN ACCORDANCE WITH BS 8500-2.
TO SUIT SITE LOCATION INFRASTRUCTURE REFER TO :- NR/SP/CIV/003. REINFORCEMENT TO BE GRADE 500 BAR IN
ACCORDANCE WITH BS4449, OR MESH FABRIC IN
ACCORDANCE WITH BS4483.
HINGED COLUMN TO BE INSTALLED COVER TO ALL REINFORCEMENT TO BE 50MM.
TO FALL AWAY FROM TRACK FOR MASS CONCRETE FILL TO BASE TO BE
MAINTENANCE PURPOSES. COMPRESSIVE STRENGTH CLASS C16/20.
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER
Signature: Title:
2035

3200
Name: Date:

17.12.
01 P.J. FIRST ISSUE S.C.
2014
6m LIGHTING 8m LIGHTING
Rev'
Rev Date Name Description of Revisions
Check

Client
1505

1505
DOOR DOOR
Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
GROUND GROUND Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
LEVEL LEVEL
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.

Project Title
500

500

INFRASTRUCTURE ACCESS POINTS


BEST PRACTICE DESIGN GUIDE
CABLE ENTRY (150x50) CABLE ENTRY (150x50)
STANDARD DETAILS
1200

1200
1450

1450

Drawing Title
MASS CONCRETE FOUNDATION GRADE
ST2. CONCRETE TO BE RAMMED AS
MASS CONCRETE FOUNDATION GRADE FILLING PROCEEDS. 6m & 8m HEAVY DUTY HINGED LIGHTING
ST2. CONCRETE TO BE RAMMED AS
FILLING PROCEEDS.
COLUMN FOUNDATION DETAILS

Drawn By Name Sig. Date


ON 25mm SAND BLINDING ON 25mm SAND BLINDING P.JENYON 17.12.14
Checked By Name Sig. Date
600 600 S.CHAMBERS 17.12.14
Approved By Name Sig. Date
J.SHERIDAN 17.12.14
SECTION A-A (1:25) SECTION B-B (1:25) AS SHOWN @ A3
Sheet
1
of
1

TYPICAL 6m ABACUS T067RLH HEAVY DUTY TYPICAL 8m ABACUS T087RLH HEAVY DUTY Site Coordinates
N/A
ELR
N/A
Chainage
N/A
Drawing No. Revision

LIGHTING COLUMN FOUNDATION DETAILS LIGHTING COLUMN FOUNDATION DETAILS 075481/CV/005 01


NOTES
1. ALL DIMENSIONS IN MILLIMETRES UNLESS NOTED
OTHERWISE. DO NOT SCALE THIS DRAWING.

2. GUARD RAIL TO BE IN ACCORDANCE WITH


NETWORK RAIL DOCUMENT NR/GN/SIG/11210
APPENDIX 2G05

3. ALL COMPONENTS TO BE SECURED WITH EPOXY IN


ACCORDANCE WITH MANUFACTURERS
SPECIFICATION.
1000
4. GUARD RAIL TO BE GREY - RAL 7047

5. FOR FURTHER DETAILS OF CIVIL ENGINEERING


WORKS REFER TO :- NR/L3/CIV/140-MODEL
50mm OD (40mm ID) CLAUSES. FOR FURTHER DETAILS OF TECHNICAL
50mm OD (40mm ID)
GRP POSTS. APPROVAL OF DESIGN, CONSTRUCTION &
GRP POSTS. MAINTENANCE OF CIVIL ENGINEERING
INFRASTRUCTURE REFER TO :- NR/SP/CIV/003.
A A B B
6. HANDRAIL SHALL BE CAPABLE OF WITHSTANDING A
PLAN ON FOUNDATION (1:20) PLAN ON FOUNDATION - HORIZONTAL FORCE OF 400N/m ACTING AT THE
HEIGHT OF HANDRAILS IN ACCORDANCE WITH
ALTERNATIVE POST FIXING NETWORK RAIL COM[ANY STANDARD
NR/SP/OHS/069
50mm OD (40MM ID) DETAIL (1:20)
GRP RAILS.

50mm OD (40mm ID)


GRP POSTS.
17.12.
BASE MOUNTED GRP POST FIXED 01 P.J. FIRST ISSUE S.C.
2014
WITH 4 NO. M12 GALVANISED
1100

STEEL RESIN ANCHORS, OR IN Rev Date Name Description of Revisions


Rev'
Check
MASS CONCRETE FOUNDATION ACCORDANCE WITH
MANUFACTURERS Client
GRADE ST2, 400x400x700mm DEEP.
SPECIFICATION.
CONCRETE TO BE RAMMED AS
500

FILLING PROCEEDS & TOP TO BE


GROUND CHAMFERED AT 1:40. GROUND
LEVEL LEVEL

FORMATION LEVEL

DEPTH TO SUIT
DEPTH TO SUIT
Property and infrastructure
600 Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.

Project Title
INFRASTRUCTURE ACCESS POINTS
ALL EXCAVATED 450
1000 MATERIAL TO BE 225 225 BEST PRACTICE DESIGN GUIDE
FILLED WITH CONCRETE REINSTATED IN 150mm STANDARD DETAILS
ON 25mm SAND 2000 COMPACTED LAYERS
BLINDING SECTION B-B ALTERNATIVE Drawing Title

SECTION A-A GRP GUARD RAIL ELEVATION (1:20) POST FIXING DETAIL (1:20) HEAVY DUTY GRP HANDRAIL DETAILS

Drawn By Name Sig. Date


P.JENYON 17.12.14
Checked By Name Sig. Date
S.CHAMBERS 17.12.14
Approved By Name Sig. Date
J.SHERIDAN 17.12.14
Sheet of
AS SHOWN @ A3 1 1
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER
Site Coordinates ELR Chainage

Signature: Title: N/A N/A N/A


Drawing No. Revision
Name: Date:
075481/CV/006 01
GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

Road width varies

Type 3 granular sub-base material


(subject to designers requirement)
Existing Finished Existing
Ground road level Ground

17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check

Client

Tensar TriAx used to create Geotextile weed Proof rolled formation


mechanically stabilized layer membrane
(subject to detailed design) Overall depth of
access road to
be site specific

Property and infrastructure


STONE ACCESS ROAD DETAILS Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
(Subject to site specific design) T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.


Note:
Project Title
All soft spots encountered are to be removed and
replaced by 6F2/6F5 material in accordance with INFRASTRUCTURE ACCESS POINTS
specification for Highway Works' series 600.
BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title
Alternate option
N.R. approved manufacturer surfacing
(i.e. Truck Pave). TYPICAL ROLLED STONE ACCESS
ROAD DETAILS

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:10 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 007 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

30mm thick AC 10 close surf 100/150 to BS EN 13108-1


50mm thick HRA 30/14 f surf 40/60 chip 8/14 to BA EN 13108-4
60mm thick AC 20 dense bin 100/150 to BS EN 13108-1
for sub-base and

60mm thick AC 20 dense bin 100/150 to BS EN 13108-1


Refer to table A

capping layer

Type 1 granular sub-base material to S.H.W. 800 150mm thick AC 32 dense base 100/150 to BS EN 13108-1

for sub-base and


Refer to table A
Type 1 granular sub-base material to S.H.W. 800

capping layer
Capping layer - class 6F5 (or 6F2) capping material

Lotrack 2800 geotextile (or equivalent) Capping layer - class 6F5 (or 6F2) capping material

Sub formation level Lotrack 2800 geotextile (or equivalent)


Subgrade CBR (%)
Sub formation level
Subgrade CBR (%)

ACCESS TYPE 2 ACCESS TYPE 3/4


17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check

Client

Table A: Foundation thickness based on selected subgrade CBR values -


pavement and track form designed in accordance with HD26/06
foundation class 2. Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
SUB BASE ONLY DESIGN Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

SUBGRADE CBR (%) 2.5 3 4 5 7 10 15 T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.


SUB BASE (TYPE 1) mm 450 420 360 320 290 250 200
Project Title
TOTAL THICKNESS mm 450 420 360 320 290 250 200 INFRASTRUCTURE ACCESS POINTS
SUB BASE AND CAPPING DESIGN BEST PRACTICE DESIGN GUIDE
SUBGRADE CBR (%) 2.5 3 4 5 7 10 15
STANDARD DETAILS
SUB BASE (TYPE 1) mm 350 320 270 240 220 180 150 Drawing Title

CAPPING (SERIES 600) mm 250 240 220 210 190 170 150
TYPICAL ASPHALT CONCRETE
TOTAL THICKNESS mm 600 560 490 450 410 350 300
ACCESS ROAD DETAILS

NEW CARRIAGEWAY CONSTRUCTION Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
STANDARD DETAIL Checked By Name Sig. Date
17.12.14
J.W. J.WHITE
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:20 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 008 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

Finished level

Pavement
Depth of

Concrete slab Grade PAV2


Proof rolled formation
1200g polyethylene
Type 1 GSBM
Capping (6F2 or 6F5)

17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check

Client

Subject to detail design.

Property and infrastructure


Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.

Project Title
INFRASTRUCTURE ACCESS POINTS
BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title

TYPICAL CONCRETE
HARDSTANDING / ACCESS ROAD
DETAILS
Drawn By Name Sig. Date
L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
NTS @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 009 Rev 01


GENERAL NOTES:

Galvanized mild steel barrier guard ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH
rail complete with guard rail system Galvanized mild steel barrier guard THE REQUIREMENTS OF NETWORK RAIL COMPANY
to be installed strictly in accordance rail complete with 127x76UB post PROCEDURES
with manufacturers details. and base plate. Guard rail system to
100mm wide 8mm be installed strictly in accordance
Thick stiffener with manufacturers details.

600
600
Notes:
1. Fishtailed end unit to be fixed to
all barrier ends.

412
412
127x76 UB
2. Post centres as per
manufacturers detail, but a
minimum of 2m centres. A A
12mm Thick
base plate - see detail

formation level
Mass concrete foundation grade

formation level
Mass concrete foundation grade

Depth to suit
Depth to suit
ST2. Concrete to be rammed as ST2. Concrete to be rammed as
filling proceeds. filling proceeds.

25mm sand blinding on 25mm sand blinding

17.12.
450 450 01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions

ROOTED ARMCO BARRIER DETAIL ARMCO BARRIER RIDGID DUCT DETAIL Client
Check

(PREFERRED OPTION)

Galvanized mild steel barrier guard


rail complete with 127x76UB post
and base plate. Guard rail system to
be installed strictly in accordance
with manufacturers details. 12mm Thk. base plate c/w Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

SECTION A-A
600

Capita Property and Infrastructure Ltd.

PLAN ON FOUNDATION Project Title


412

127x76 UB INFRASTRUCTURE ACCESS POINTS


BEST PRACTICE DESIGN GUIDE
12mm Thick 330

45
B base plate - see detail B 60 STANDARD DETAILS
Drawing Title

250
100mm wide
8mm Thick ARMCO BARRIER DETAILS
stiffener

Concrete
Base/Apron

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
SECTION B-B Checked By
J.W.
Name
J.WHITE
Sig. Date
17.12.14
ARMCO BARRIER BASE Approved By
J.W.
Name
J.WHITE
Sig. Date
17.12.14

ARMCO BARRIER DETAIL FIXED PLATE DETAIL


Scale
NTS @ A3
Site Coordinates ELR
Sheet
1
Chainage
of
1
N/A N/A N/A
TO CONCRETE BASE/APRON Drawing No.

075481 / CV / 010 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES
Bollards installed at YPL Street Furniture
Bollards installed at 1.5m centres Unit 9 Royal Business Park
1.5m centres King Street
Pontefract
YPL Economy Telescopic Post Lifting handle
WF8 4AH
Heavy duty galvanised 100x100
steel section (YPLECO) Tel: 00(44) 1977 600999
Email: Sales@ypl-streetfurniture.co.uk
Removable steel bollard
(YPL889 Galvanised or

610

1000
YPL010m powder coated)

G.L. top bollard

Hinged cover plate


Bollard
450 minimum
G.L.

of concrete
50mm Grass: +50mm (with 50mm chamfer)
200 200 chamfer Asphalt conc.: -60mm
Concrete: integral with slab
785 G.L.

300
Concrete to be grade ST4
to BS 8500 and BSEN 206.
20mm clean

150
5mm box section,
galvanised. chippings
6mm base plate complete compacted Concrete to be grade ST4 200 200 Concrete to be grade ST4
150

with water outlet to BS 8500 and BSEN 206. to BS 8500 and BSEN 206.

DROP BOLLARD REMOVABLE BOLLARD TYPICAL CONCRETE BASE 01


17.12.
L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check

Client

Bollards installed at Bollards installed at


1.5m centres 1.5m centres

Bollard constructed
Property and infrastructure

1300
Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
with concrete. Painted
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
with yellow and black
915

Marshalls banding. Capita Property and Infrastructure Ltd.


Bridgford
Project Title
INFRASTRUCTURE ACCESS POINTS
Ground
level BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Bottom 500mm to be Drawing Title
given 3 coats of RIW
NOTES and set into C25
500
455

1. All dimensions in millimetres. concrete bases 200mm BOLLARD DETAILS


minimum surround.
2. Concrete markers and bollards to be ST4
concrete to BS.5328 PT2
3. Bollards to have smooth plain white concrete
finish or beadalite finish if required.
Drawn By Name Sig. Date
270 dia L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
PRECAST CONCRETE BOLLARD PERMANENT STEEL BOLLARD Scale
NTS @ A3
Sheet
1
of
1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 011 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

50x150mm Flat top P.C.C


edging kerb each side of
road

Proposed Road level

Existing landscape

50mm
200mm
150mm
min.
ST2 Concrete 200mm 200mm

EDGING KERB
17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check

Client
150

125 125x255mm half battered


50 lightweight recycled polymer
20

50 Finished road level kerb (Durakerb or similar


approved product)

60

125mm
70

Finished road level


150

125x150mm dropped
75

150
Bullnosed lightweight Property and infrastructure
recycled polymer kerb Special Projects, 2nd Floor Clemence House, Mellor Road,
25
150 min

(Durakerb or similar Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

approved product) For road construction T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

details refer to typical Capita Property and Infrastructure Ltd.

150
details
Project Title
ST2 Concrete
275
INFRASTRUCTURE ACCESS POINTS
ST2 Concrete 350 BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
DROPPED KERB Drawing Title
Not for use on public highways
HALF BATTER KERB
LIGHTWEIGHT KERBING DETAILS -
(DURAKERBS)

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:10 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 012 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
305 x 150mm CD PROCEDURES
150 dished channel ST1 concrete
150
Kerb face -25mm as vehicular crossing bed and haunch
- 6mm as pedestrian crossing

60

125
Kerb face

60

60
15 125 x 150mm P.C.C. bull nosed
125 x 255mm P.C.C. kerb type BN to BS EN 1340

15

200
150
150
ST1 concrete half battered kerb type 15mm min mortar

15
bed and haunch HB2 to BS EN 1340 (see note 4)
300 15mm min mortar 300
ST1 concrete bed 125
(see note 4) 305
and haunch
555

KERB TYPE HB2 KERB TYPE BN


(BULL NOSED KERB DISHED CHANNEL TYPE
(HALF BATTERED KERB
125x150mm) CD
125x255mm)

NB. Where insufficient haunching/backing is available, vertical dowel


holes are moulded into the unit. dowel bars should then be put into the
unit & anchored securely. 50 x 200mm P.C.C. flat top
edging type EF to BS EN 50 x 150mm P.C.C. flat top
180 200
1340 edging type EF to BS EN
80

70

50
1340
160

15
230
25

C'way
415

17.12.

100

100
60

60
01 L.Z. First issue J.W.
2014
115

ST1 concrete ST1 concrete


X

250 250
445

bed and haunch bed and haunch Rev Date Name Description of Revisions
Rev'
Check

X = min 25 15mm min mortar 15mm min mortar Client


max 65 (see note 4) (see note 4)
dowel holes
15mm min mortar
230 380 (see note 4)

HIGH CONTAINMENT EDGING TYPE EF EDGING TYPE EF


KERB WITH DOWEL 50mm upstand Flush
(Edging 50x200mm) (Edging 50x150mm) Property and infrastructure
HOLES Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.

Project Title
INFRASTRUCTURE ACCESS POINTS
NOTES BEST PRACTICE DESIGN GUIDE
1. Do not scale off this drawing. STANDARD DETAILS
2. All dimensions in millimetres unless otherwise stated.
3. Unless specified otherwise steel dowel bars shall be used where Drawing Title
kerb bedding / backing is laid separately. If used dowel bars shall be
300mm long 20mm diameter mild steel at 450mm centres.
4. Mortar only to be used when kerb laid on cured concrete. PRE-CAST CONCRETE KERBING
Designation (i) mortar to be used. DETAILS
5. All kerbs to be precast concrete.

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:20 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 013 Rev 01


NOTES:
1. All dimensions in millimetres unless noted otherwise.
Do not scale this drawing.

2. For futher details, refer to manufacturer.

AQUA.
Belmont House,
Garnett Place,
Skelmersdale,
Lancashire,
WN8 9UB.
Tel 01695 51933.
Email. sales@aquafab.co.uk.
Fax. 01695 51891.
Web. www.aquafab.co.uk

Entry to be
Galvanised solid site specific
lid with frame Finished ground
CL (Cover Level) level

HDPE chamber

Incoming
backfill.

site specific
Entry to be
pipes

17.12.
Depth to be site specific

01 L.Z. First issue J.W.


2014
Rev'

X X Rev

Client
Date Name Description of Revisions
Check

100 Incoming
pipes

site specific
Entry to be
Incoming
100

pipes
IL

300
Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
Clean 20/40mm single
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
sized aggregate or 40mm
100

gravel surround Capita Property and Infrastructure Ltd.

PLAN ON SOAKAWAY Project Title


Concrete base INFRASTRUCTURE ACCESS POINTS
slab
BEST PRACTICE DESIGN GUIDE
SECTION X-X STANDARD DETAILS
Drawing Title

TYPICAL SOAKWAY DETAIL


TYPICAL AQUA SOAKWAY DETAILS NON TRAFFICKED AREAS
For non-vehicle traffic only. Subject to detail design & liason with
manufacture based on Aqua Thieel chamber.

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:20 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 014 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

Class B solid engineering bricks,


concrete blocks or precast concrete 750mm sq clear opening D400 (min)
cover frame seating rings ductile iron cover and frame bedded
on mortar with a mortar haunch

GL

750

1050 diameter manhole rings Geotextile filter membrane shall be


changing to 1050 soakaway 750
provided to the top, bottom and all
rings sides of the soak away pit. Geotextile
membrane to be Lotrak 2300 or
Polyfelt TS50 or approved equivalent.

Clean 20/40mm single sized


aggregate or 40mm gravel
Top stone surround / base infill to 17.12.
Geotextile Geotextile soakaway. 01 L.Z. First issue J.W.
2014
IL
Rev'
Rev Date Name Description of Revisions
Check

Client

Geotextile
Geotextile

3500
Geotextile

Geotextile
BL Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
1050mm diameter PCC
Soakaway rings with 75mm T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

diameter holes Capita Property and Infrastructure Ltd.


450

Project Title
INFRASTRUCTURE ACCESS POINTS
Geotextile Geotextile Geotextile BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
GEN 3 concrete ring Drawing Title
foundations for the 300 (min) 300 (min)
soakaway rings
Clean 20/40mm single sized aggregate
or 40mm gravel surround / base infill to
TYPICAL SOAKWAY DETAIL
soakaway. TRAFFICKED AREAS

TYPICAL SECTION THROUGH SOAKAWAY


Drawn By Name Sig. Date
L.Z. L.ZEMAN 17.12.14
Subject to detail design. Checked By Name Sig. Date
17.12.14
J.W. J.WHITE
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:20 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 015 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES
Vertical saw cut to
Kerb existing Binder course
Existing Carriageway Vertical saw cut to existing
Surface course. Joint to be
painted with hot bitumin (Cl 706)
Surface course
Binder course
300 300
Base course Existing material to be planed Existing Carriageway
Or as directed by Engineer Proposed carriageway profile

100

130
or removed with hand tools

40

60
Sub-base Surface course
Binder course
Base course
L
FIL

Existing Carriageway to be planed

min
100
CUT

Capping layer The edge of existing carriageway to


Sub-base
be cut back 300mm to sound face or Surface course regulating material
as directed by the Engineer
Binder course regulating material
Where this dimension is in a taper section and varies Existing carriageway profile
425
from 0 to 750mm then concrete may be used in lieu of Base course regulating material
Base course Concrete to be C7.5, wet lean concrete to Cl
1030 with 75mm slump, placed with vibrating poker

CONSTRUCTION DETAILS ADJACENT TO EXISTING REGULATING COURSE IN AREA OF BUILD


CARRIAGEWAY (LONGITUDINAL TIE-IN DETAIL) UP ON EXISTING CARRIAGEWAY
CLAUSES REFER TO THE SPECIFICATION FOR HIGHWAY WORKS
(TRANSVERSE TIE-IN DETAIL)
17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check

Client

Transition joint location


Shown on plan Existing
Footway 75 75
Surface course 3000 Reinforcement
Binder course 1000
Concrete surface Surface Property and infrastructure
Base course 300 course Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
Sub-base
Binder course T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Sub Base Capita Property and Infrastructure Ltd.

1 Project Title
10
All joints to be saw INFRASTRUCTURE ACCESS POINTS
Detail design 200mm cut and sealed
Sub-base Transition slab 20mm mild steel bars BEST PRACTICE DESIGN GUIDE
1m long at 300 centres.
STANDARD DETAILS
TRANSITION JOINT BETWEEN CONCRETE FOOTWAY TIE-IN DETAIL Drawing Title

AND ASPHALT CONCRETE SURFACING


TIPICAL HARDSTANDING / ACCESS
ROAD TIE-IN DETAILS

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
NTS @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 016 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

Dimensions marked thus *


Top of channel 100 - load class A15
3mm below 150 - load class B125
Slotted ductile iron grating 200 - load class D400
pavement 185 Top of channel
refer to loading classes Channel
3mm below Slotted ductile iron grating
150 pavement width
Dimensions marked thus * * * refer to loading classes

35
100 - load class A15
150 - load class B125 Concrete Concrete

Varies
* 200 - load class D400 hardstanding hardstanding
60

Linear drainage channel


Linear drainage channel (subjec to detail design)
* (subjec to detail design)

*
Min C25/30 concrete Min C25/30 concrete
bedding and haunch. bedding and haunch.

LINEAR DRAINAGE UNIT LINEAR DRAINAGE UNIT


DETAIL ASPHALT DETAIL CONCRETE
PAVEMENT PAVEMENT 17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check

Client

Property and infrastructure


Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.

Project Title
INFRASTRUCTURE ACCESS POINTS
BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title

TYPICAL LINEAR DRAINAGE


CHANNEL DETAILS

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:20 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 017 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY

150

160
PROCEDURES

210

430
750

330

150
400
800

500
150

210

160
150
150 375 150
150 350 150 Formation
Formation
drainage slot drainage slot
375
650

PLAN OF P.C. COVER SLAB FOR PLAN OF P.C. COVER SLAB FOR
500mm * 350mm GRATING AND FRAME 430mm * 370mm GRATING AND FRAME 01
17.12.
L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions

NOTES
Check

Joint between kerb and frame filled and Client


pointed with polyester resin mortar See Note 1 1. End hinged ductile iron gully grating and frame to
BS EN 124:1994 Class D400 (see note 5) bedded
Concrete ST4 cast in-situ raising piece on polyester resin mortar 10 to 20mm thick.
Formation drainage slot
rebated as necessary and finised smooth and
10

even. Portland cement is to be used when the 2. Gratings shall be available with either left or right
Carriageway
ambient temperature can be expected to fall hand hinges as viewed when facing the kerb.
Hinged end to be nearest on-coming traffic. The
grating shall be captive within the frame.
330 min
Varies

Property and infrastructure


50

Formation 3. All in-situ concrete to be medium workability / Special Projects, 2nd Floor Clemence House, Mellor Road,
150

Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure


Level 75mm slump.
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
Bend as required
4. Precast concrete gully cover slab ST4 with Capita Property and Infrastructure Ltd.

Flexcell minimum cement content 300 kg/m3 and 0.60 Project Title
joint maximum water/cement ratio. Workability to suit
method of manufacture. INFRASTRUCTURE ACCESS POINTS
BEST PRACTICE DESIGN GUIDE
150mm diameter 5. Dimensions of opening on upper face of PC cover
outlet STANDARD DETAILS
slab shall be the same as the clear opening at the
450*750*150 concrete street underside of the frame. Tolerance is permitted on Drawing Title
gully to BS5911 Part 6 all other cover slab dimensions
CONCRETE ROAD GULLY
Stopper &
chain FOR ACCESS ROAD
Flexcell
joint
Drawn By Name Sig. Date
L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
150mm bed and J.W. J.WHITE 17.12.14
150mm bed and surround
concrete ST4 surround concrete ST4 Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1 :10 @ A3 1 1
CONCRETE Site Coordinates
N/A
ELR
N/A
Chainage
N/A

ROAD GULLY Drawing No.

075481 / CV / 018 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

Additional access shafts dependent


upon Separator size and manufacturer 1500 diameter PCC rings required for maintenance access
on separators with a cover of 1.25m and over
1220*685 multiple cover required
Manhole cover classification
dependant upon location
Finished Level
construction
External

17.12.
01 L.Z. First issue J.W.
2014
Positioned on
filter access Rev Date Name Description of Revisions
Rev'
Check
unit
200mm thick R.C. capping slab Client
reinforced with 2 layers of A393
mesh 1 top + 1 bottom (40mm cover)
1000 over hang 1000 over hang
all round 75mm thick layer of all round
polystyrene

Profile of P.I. is indicative only. NOTE


Concrete surround to tank in
accordance with manufacturers
Concrete to capping slab to be grade
C35/20 with a minimum cement content
Property and infrastructure
installation instructions Special Projects, 2nd Floor Clemence House, Mellor Road,
of 330kg/m3 and a maximum free Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
water/cement ratio of 0.55.
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk

Capita Property and Infrastructure Ltd.

Project Title
TYPICAL SECTION THROUGH OIL INFRASTRUCTURE ACCESS POINTS
SEPARATOR IN TRAFFICKED AREA BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title

TYPICAL OIL SEPARATOR

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:50 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 019 Rev 01


GENERAL NOTES:

ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH


THE REQUIREMENTS OF NETWORK RAIL COMPANY
PROCEDURES

Surface to be reinstated
to match existing
Finished ground
level

500
20mm Single size stone

17.12.
01 L.Z. First issue J.W.
2014

Rev'
Rev Date Name Description of Revisions
Check

Client

150
pipe (pipes to be laid with
perforations at invert). Terram 1000 lining or similar approved product.

Filter material 10mm clean pea gravel.

Property and infrastructure


Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure

T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk


150

Capita Property and Infrastructure Ltd.

Project Title
INFRASTRUCTURE ACCESS POINTS
50

150
BEST PRACTICE DESIGN GUIDE
150
STANDARD DETAILS
Geotextile filter membrane on Drawing Title
600 50mm thick layer of sand bedding.

FILTER DRAIN DETAILS


FILTER DRAIN DETAIL

Drawn By Name Sig. Date


L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1:10 @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.

075481 / CV / 020 Rev 01

You might also like