0 Appendix C/ – Standard
March 2015
Details
BS EN 10025 : 1993 UNLESS OTHERWISE SPECIFIED. NR/PRC/MPI/CI0024: CONTROL AND USE OF METAL
6mm THK SLAM PLATE PINS AND SPIKES ON NETWORK RAIL
TRIANGULAR GUSSET PLATE ALL BOLTS SHALL COMPLY WITH BS 3692 AND SHALL BE STRENGTH INFRASTRUCTURE
GROUND GRADE 8.8. NUTS SHALL BE STRENGTH GRADE 8 AND WASHERS NR/PRC/MPI/CIOO26 PROCESS: FOR LOCATING
LEVEL SHALL CONFORM TO BS 4320. ALL BOLTS, NUTS AND WASHERS BURIED SERVICES PRIOR TO GROUND PENETRATION.
SHALL BE ZINC COATED.
FENCES JOINED TO EXISTING FENCES, WALLS OR OTHER
525mm MINIMUM EMBEDMENT
DROP BOLT ALL CONNECTIONS SHALL BE BOLTED IN ACCORDANCE WITH BS 1722 STRUCTURES TO PROVIDE A COMPLETE BARRIER TO
INTO 600x600x1100mm
: PART 12. PERSONS OR ANIMALS AS APPROPRIATE.
1100
300
CONCRETE FOOTING
600 OPTIONAL ITEMS REQUIRED FOR ADDITIONAL SECURITY ARE TO BE FENCES SHALL BE ACCURATELY SET OUT AND ERECTED
SPECIFIED IN A PROJECT SPECIFIC FORM A/B TO PROVIDE A SMOOTH ALIGNMENT IN PLAN AND
ELEVATION, FOLLOWING THE CONTOURS OF THE GROUND
ALL BEDDING CONCRETE FOR VERTICAL FENCE POSTS TO BE MASS AS CLOSELY AS IS PRACTICABLE.
TYPICAL 1.8m HIGH 6m WIDE PALISADE GATE (1:50) CONCRETE MINIMUM GRADE ST2 TO BS 8500-1.
(TYPICAL EXTERNAL VIEW) THE LINE OF THE FENCING SHALL BE CLEARED OF ALL
INSTALLATION GUIDANCE: PALISADE FENCING IMPENDING VEGETATION AND TRIMMED TO REMOVE ANY
IRREGULARITIES TO ENABLE FENCE INFILL PANELS TO BE
TO LIMIT DEFLECTION IN FENCE RAILS, THE BOTTOM HORIZONTAL ERECTED AT A CONSTANT DISTANCE FROM THE GROUND.
RAIL SHALL BE SUPPORTED SO THAT AFTER TIGHTENING OF THE
102x44x7.5 RSJ WITH POINTED BOLTS, ALIGNING AND PLUMBING TO THE FENCE THERE IS A SLIGHT
2750
MAX 155 TOP UPWARD CAMBER. THIS SUPPORT SHOULD BE REMOVED ONLY ONCE
THE CONCRETE HAS SET.
102x44x7.5 RSJ CENTRES 40x40x6 RSA RAILS TOP AND
A BOTTOM CONCRETE
40x40x6 RSA RAIL
CONCRETE: C30/37, AC-4, DC-4, AGGREGATE: 20mm (MAX.)
3.0mm THICK CORRUGATED MINIMUM 3.0mm THICK x 70mm SULPHATE AND CHLORIDE RESISTANT 17.12.
PALES FIXED TO RAILS AT WIDE CORRUGATED 'W' 01 P.J. FIRST ISSUE S.C.
225
225
1800
CENTRES, WITH TRIPLE GROUND CONDITION: AVERAGE FOR PLANTED (ROOT) FOUNDATION Rev Date Name Description of Revisions
Rev'
Check
POINTED TOPS WITH SPLAYED WATER TABLE: WELL BELOW THE FOUNDATION, AND SITE IS NOT Client
40x40x6 RSA RAIL HEADS POINTING OUTWARDS SUSCEPTIBLE TO FLOODING
100
100
50 MAX.
CONCRETE FOOTING
THE FOLLOWING ARE SIGNIFICANT HAZARDS WHICH MIGHT AFFECT THE HEALTH
600 AND SAFETY OF THOSE UNDERTAKING THE WORKS OUTLINED IN THIS SET OF
A DRAWINGS ON RAILWAY STRUCTURES OR THOSE AFFECTED BY THESE Property and infrastructure
ACTIVITIES. A SITE SPECIFIC RISK ASSESSMENT SHOULD ALWAYS BE Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
UNDERTAKEN PRIOR TO COMMENCING ANY OF THE WORKS DESCRIBED ON SITE.
SECTION A-A (1:50) TYPICAL 1.8m HIGH PALISADE FENCE (1:50) IT IS ASSUMED THAT A COMPETENT CONTRACTOR IS AWARE OF THE RISKS
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
DAMAGE TO ROOTS OR SPECIFIC METHOD STATEMENT TO DETAIL 1.8m HIGH 6m WIDE PALISADE
PROTECTED TREES C PROVISION FOR ROOT PROTECTION OF
TREES DURING WORKS. GATE & FENCE DETAILS -
INJURY TO ADJOINING
SECURITY LEVEL 1 & 2
ADJOINING LANDOWNERS TO BE
LANDOWNERS C INFORMED AHEAD OF WORKS.
Drawn By Name Sig. Date
P.JENYON 17.12.14
FAILURE OF FENCE DUE TO CERTIFICATE OF CONFORMITY IN Checked By Name Sig. Date
S.CHAMBERS 17.12.14
SUB-STANDARD MATERIALS D/C ACCORDANCE WITH BS 1722 TO BE
Approved By Name Sig. Date
PROVIDED BY FENCE MANUFACTURER. J.SHERIDAN 17.12.14
Scale Sheet of
AS SHOWN @ A3 1 1
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER FAILURE OF FENCE DUE TO D/C CERTIFICATE OF CONFORMITY IN Site Coordinates ELR Chainage
Signature: Title: SUB-STANDARD INSTALLATION ACCORDANCE WITH BS 1722 TO BE N/A N/A N/A
PROVIDED BY FENCE INSTALLER. Drawing No. Revision
Name: Date:
NOTE : C=CONSTRUCTION, D=DESIGN 075481/CV/001 01
GENERAL NOTES:
SPECIFICATION:
203x203x60 UC POSTS WITH ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE
6000 POINTED TOP PALISADE FENCING SPECIFIED.
MAX 155
CENTRES GATE FRAME 100x60x5.0 RHS ALL STEEL PALISADE FENCE SHALL BE SECURITY TYPE SP30 IN ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH
ACCORDANCE WITH BS 1722 : PART 12 AND HOT DIP GALVANISED IN THE REQUIREMENTS OF NETWORK RAIL COMPANY
ACCORDANCE WITH BS EN ISO 1461. PROCEDURES
NR/SP/OHS/011: PREVENTION OF DAMAGE TO AND
ALL ROLLED STEEL SECTIONS SHALL BE OF STEEL GRADE S275 TO DANGER FROM SURFACE AND BURIED SERVICES.
ANTILIFT GATE HANGING BS EN 10025 : 1993 UNLESS OTHERWISE SPECIFIED. NR/PRC/MPI/CI0024: CONTROL AND USE OF METAL
DETAIL PINS AND SPIKES ON NETWORK RAIL
ALL BOLTS SHALL COMPLY WITH BS 3692 AND SHALL BE STRENGTH INFRASTRUCTURE
SLIDING LOCKING BAR GRADE 8.8. NUTS SHALL BE STRENGTH GRADE 8 AND WASHERS NR/PRC/MPI/CIOO26 PROCESS: FOR LOCATING
3000
SHALL CONFORM TO BS 4320. ALL BOLTS, NUTS AND WASHERS BURIED SERVICES PRIOR TO GROUND
6mm THK SLAM PLATE SHALL BE ZINC COATED. PENETRATION.
ALL CONNECTIONS SHALL BE BOLTED IN ACCORDANCE WITH BS 1722 FENCES JOINED TO EXISTING FENCES, WALLS OR OTHER
: PART 12. STRUCTURES TO PROVIDE A COMPLETE BARRIER TO
TRIANGULAR GUSSET PLATE
PERSONS OR ANIMALS AS APPROPRIATE.
OPTIONAL ITEMS REQUIRED FOR ADDITIONAL SECURITY ARE TO BE
GROUND 300x300mm INSITU CONCRETE SPECIFIED IN A PROJECT SPECIFIC FORM A/B FENCES SHALL BE ACCURATELY SET OUT AND ERECTED
LEVEL SILL. MIX ST2 TO PROVIDE A SMOOTH ALIGNMENT IN PLAN AND
ALL BEDDING CONCRETE FOR VERTICAL FENCE POSTS TO BE MASS ELEVATION, FOLLOWING THE CONTOURS OF THE GROUND
CONCRETE MINIMUM GRADE ST2 TO BS 8500-1. AS CLOSELY AS IS PRACTICABLE.
100 DIA DUCT FOR EARTHING INSTALLATION GUIDANCE: PALISADE FENCING THE LINE OF THE FENCING SHALL BE CLEARED OF ALL
300
DROP BOLT
1300
WATER TABLE: WELL BELOW THE FOUNDATION, AND SITE IS NOT Client
2750 127x76x13 UB POSTS WITH
MAX 155 SUSCEPTIBLE TO FLOODING
127x76x13 UB POINTED TOP
CENTRES A TABLE 1
50x50x6 RSA RAIL 50x50x6 RSA RAILS TOP AND
SAFETY, HEALTH & ENVIRONMENT RISK ASSESSMENT
475
475
BOTTOM
DESIGNERS' NOTE - CDM REG. 13(2)(b)
MINIMUM 3.0mm THICK x 70mm
THE FOLLOWING ARE SIGNIFICANT HAZARDS WHICH MIGHT AFFECT THE HEALTH
3.0mm THICK CORRUGATED WIDE CORRUGATED 'W'
AND SAFETY OF THOSE UNDERTAKING THE WORKS OUTLINED IN THIS SET OF
PALES FIXED TO RAILS AT FENCING PALES AT EQUAL
DRAWINGS ON RAILWAY STRUCTURES OR THOSE AFFECTED BY THESE Property and infrastructure
155mm CENTRES CENTRES, WITH TRIPLE
ACTIVITIES. A SITE SPECIFIC RISK ASSESSMENT SHOULD ALWAYS BE Special Projects, 2nd Floor Clemence House, Mellor Road,
3000
POINTED TOPS WITH SPLAYED Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
UNDERTAKEN PRIOR TO COMMENCING ANY OF THE WORKS DESCRIBED ON SITE.
HEADS POINTING OUTWARDS
3000
RISK STAGE
GROUND GROUND BEST PRACTICE DESIGN GUIDE
LEVEL LEVEL SPECIFIC METHOD STATEMENT AND RISK STANDARD DETAILS
CONTACT WITH OVERHEAD ASSESSMENT TO IDENTIFY AND DETAIL
WIRES OR BURIED SERVICES C
PROTECTION TO ALL SERVICES, BURIED Drawing Title
50 MAX.
AND OVERHEAD.
925
INTO 600x600x1300mm DAMAGE TO ROOTS OR SPECIFIC METHOD STATEMENT TO DETAIL 3.0m HIGH 6m WIDE PALISADE
CONCRETE FOOTING PROTECTED TREES C PROVISION FOR ROOT PROTECTION OF
600 A INTERMEDIATE SUPPORTS TREES DURING WORKS. GATE & FENCE DETAILS -
WITH 100mm EMBEDMENT
INJURY TO ADJOINING
SECURITY LEVEL 3
INTO CONCRETE SILL ADJOINING LANDOWNERS TO BE
LANDOWNERS C INFORMED AHEAD OF WORKS.
SECTION A-A (1:50) TYPICAL 3m HIGH PALISADE FENCE (1:50)
Drawn By Name
P.JENYON
Sig. Date
17.12.14
FAILURE OF FENCE DUE TO CERTIFICATE OF CONFORMITY IN Checked By Name Sig. Date
(TYPICAL EXTERNAL VIEW) S.CHAMBERS 17.12.14
SUB-STANDARD MATERIALS D/C ACCORDANCE WITH BS 1722 TO BE
Approved By Name Sig. Date
PROVIDED BY FENCE MANUFACTURER. J.SHERIDAN 17.12.14
Scale Sheet of
AS SHOWN @ A3 1 1
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER FAILURE OF FENCE DUE TO D/C CERTIFICATE OF CONFORMITY IN Site Coordinates ELR Chainage
Signature: Title: SUB-STANDARD INSTALLATION ACCORDANCE WITH BS 1722 TO BE N/A N/A N/A
PROVIDED BY FENCE INSTALLER. Drawing No. Revision
Name: Date:
NOTE : C=CONSTRUCTION, D=DESIGN 075481/CV/002 01
GENERAL NOTES:
SPECIFICATION:
ALL DIMENSIONS IN MILLIMETRES UNLESS OTHERWISE
152x152x37 UC POSTS WITH PALISADE FENCING SPECIFIED.
1500 POINTED TOP
MAX 155
CENTRES ALL STEEL PALISADE FENCE SHALL BE SECURITY TYPE GP18/SP30 IN ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH
GATE FRAME 90x50x3.6 RHS ACCORDANCE WITH BS 1722 : PART 12 AND HOT DIP GALVANISED IN THE REQUIREMENTS OF NETWORK RAIL COMPANY
ACCORDANCE WITH BS EN ISO 1461. PROCEDURES
NR/SP/OHS/011: PREVENTION OF DAMAGE TO AND
ALL ROLLED STEEL SECTIONS SHALL BE OF STEEL GRADE S275 TO DANGER FROM SURFACE AND BURIED SERVICES.
BS EN 10025 : 1993 UNLESS OTHERWISE SPECIFIED. NR/PRC/MPI/CI0024: CONTROL AND USE OF METAL
ANTILIFT GATE HANGING DETAIL PINS AND SPIKES ON NETWORK RAIL
ALL BOLTS SHALL COMPLY WITH BS 3692 AND SHALL BE STRENGTH INFRASTRUCTURE
GRADE 8.8. NUTS SHALL BE STRENGTH GRADE 8 AND WASHERS NR/PRC/MPI/CIOO26 PROCESS: FOR LOCATING
SLIDING LOCKING BAR SHALL CONFORM TO BS 4320. ALL BOLTS, NUTS AND WASHERS BURIED SERVICES PRIOR TO GROUND PENETRATION.
3000
TAPE ON INSIDE OF COMPOUND TO LIMIT DEFLECTION IN FENCE RAILS, THE BOTTOM HORIZONTAL ERECTED AT A CONSTANT DISTANCE FROM THE GROUND.
RAIL SHALL BE SUPPORTED SO THAT AFTER TIGHTENING OF THE
925mm MINIMUM EMBEDMENT BOLTS, ALIGNING AND PLUMBING TO THE FENCE THERE IS A SLIGHT
600 UPWARD CAMBER. THIS SUPPORT SHOULD BE REMOVED ONLY ONCE
INTO 600x600x1300mm
CONCRETE FOOTING THE CONCRETE HAS SET.
CONCRETE
TYPICAL 3.0m HIGH 1.5m WIDE PALISADE CONCRETE: C30/37, AC-4, DC-4, AGGREGATE: 20mm (MAX.)
GATE (1:50) SULPHATE AND CHLORIDE RESISTANT
DISTANCE TO COAST: 2km, SITE ALTITUDE: 100m AMSL
01
17.12.
2014 P.J. FIRST ISSUE S.C.
(TYPICAL EXTERNAL VIEW) WIND SPEED: 25m/s, ENVIRONMENT: TYPICAL OPEN COUNTRYSIDE
Rev'
GROUND CONDITION: AVERAGE FOR PLANTED (ROOT) FOUNDATION Rev Date Name Description of Revisions
Check
WATER TABLE: WELL BELOW THE FOUNDATION, AND SITE IS NOT Client
SUSCEPTIBLE TO FLOODING
TABLE 1
Signature: Title: SUB-STANDARD INSTALLATION ACCORDANCE WITH BS 1722 TO BE N/A N/A N/A
PROVIDED BY FENCE INSTALLER. Drawing No. Revision
Name: Date:
NOTE : C=CONSTRUCTION, D=DESIGN 075481/CV/003 01
GENERAL NOTES:
5. THE VERTICAL EDGE OF THE CONCRETE 1. ALL DIMENSIONS IN MILLIMETRES UNLESS NOTED
FOUNDATION SHALL BE FORMED TO A CLASS F2 OTHERWISE.
6m LIGHTING 8m LIGHTING FINISH IN ACCORDANCE WITH SECTION 80 CLAUSE
80.033 OF THE SPECIFICATION. THE TOP OF THE 2. DO NOT SCALE THIS DRAWING.
FOUNDATION SHALL HAVE A SWEPT BRUSH FINISH
A A B B
WITH FLOATED EDGES, 100mm WIDE. 3. GROUND UNDER CONCRETE FOUNDATION TO BE
WELL COMPACTED PRIOR TO LAYING CONCRETE.
6. THE TOP SURFACE OF THE FOUNDATIONS SHALL ANY SOFT SPOTS TO BE EXCAVATED OUT AND
BE SET TO LEVEL WITH A TOLERANCE OF +/- 5mm. BACKFILLED WITH TYPE 1 FILL WELL COMPACTED IN
DUCT DUCT
PLAN (1:20) PLAN (1:20) NO POINT SHALL HAVE A SAG GREATER THAN 3mm
FROM A 2m STRAIGHT EDGE.
150MM LAYERS.
6880
ACCORDANCE WITH BS4449, OR MESH FABRIC IN
ACCORDANCE WITH BS4483.
COVER TO ALL REINFORCEMENT TO BE 50MM.
MASS CONCRETE FILL TO BASE TO BE
COMPRESSIVE STRENGTH CLASS C16/20.
6m LIGHTING 8m LIGHTING
17.12.
01 P.J. FIRST ISSUE S.C.
2014
1000
1000
Rev'
Rev Date Name Description of Revisions
Check
Client
GROUND GROUND
LEVEL LEVEL
500
Special Projects, 2nd Floor Clemence House, Mellor Road,
1000
CABLE ENTRY (150X50) CABLE ENTRY (150X50) T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
Project Title
MASS CONCRETE FOUNDATION GRADE MASS CONCRETE FOUNDATION GRADE INFRASTRUCTURE ACCESS POINTS
ST2. CONCRETE TO BE RAMMED AS ST2. CONCRETE TO BE RAMMED AS
FILLING PROCEEDS. FILLING PROCEEDS.
BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title
075481/CV/004 01
NOTES:
5. THE VERTICAL EDGE OF THE CONCRETE 1. ALL DIMENSIONS IN MILLIMETRES UNLESS NOTED
FOUNDATION SHALL BE FORMED TO A CLASS F2 OTHERWISE.
6m LIGHTING FINISH IN ACCORDANCE WITH SECTION 80 CLAUSE
COLUMN 80.033 OF THE SPECIFICATION. THE TOP OF THE 2. DO NOT SCALE THIS DRAWING.
8m LIGHTING
FOUNDATION SHALL HAVE A SWEPT BRUSH FINISH
COLUMN
WITH FLOATED EDGES, 100mm WIDE. 3. GROUND UNDER CONCRETE FOUNDATION TO BE
A A B B WELL COMPACTED PRIOR TO LAYING CONCRETE.
6. THE TOP SURFACE OF THE FOUNDATIONS SHALL ANY SOFT SPOTS TO BE EXCAVATED OUT AND
BE SET TO LEVEL WITH A TOLERANCE OF +/- 5mm. BACKFILLED WITH TYPE 1 FILL WELL COMPACTED IN
NO POINT SHALL HAVE A SAG GREATER THAN 3mm 150MM LAYERS.
RIGID DUCT DUCT FROM A 2m STRAIGHT EDGE.
PLAN (1:25) PLAN (1:25) 7. REFER TO ABACUS DRAWINGS FOR DETAILS
4. CONCRETE TO BE DESIGNED MIX IN ACCORDANCE
WITH BS8500-2.
COMPRESSIVE STRENGTH CLASS C32/40
DESIGN CHEMICAL CLASS DC-2Z
8. FOR FURTHER DETAILS OF CIVIL ENGINEERING MAX. AGGREGATE SIZE 20mm
WORKS REFER TO :- NR/L3/CIV/140-MODEL CHLORIDE CLASS CI 0.40
2370
3175
CLAUSES. FOR FURTHER DETAILS OF TECHNICAL CONSISTENCE CLASS S3
APPROVAL OF DESIGN, CONSTRUCTION & CONCRETE BLINDING TO BE DESIGNATED MIX GEN 1
NOTE: LIGHTING POSITION MAY VARY MAINTENANCE OF CIVIL ENGINEERING IN ACCORDANCE WITH BS 8500-2.
TO SUIT SITE LOCATION INFRASTRUCTURE REFER TO :- NR/SP/CIV/003. REINFORCEMENT TO BE GRADE 500 BAR IN
ACCORDANCE WITH BS4449, OR MESH FABRIC IN
ACCORDANCE WITH BS4483.
HINGED COLUMN TO BE INSTALLED COVER TO ALL REINFORCEMENT TO BE 50MM.
TO FALL AWAY FROM TRACK FOR MASS CONCRETE FILL TO BASE TO BE
MAINTENANCE PURPOSES. COMPRESSIVE STRENGTH CLASS C16/20.
APPROVED FOR CONSTRUCTION - NETWORK RAIL CIVIL ENGINEER
Signature: Title:
2035
3200
Name: Date:
17.12.
01 P.J. FIRST ISSUE S.C.
2014
6m LIGHTING 8m LIGHTING
Rev'
Rev Date Name Description of Revisions
Check
Client
1505
1505
DOOR DOOR
Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
GROUND GROUND Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
LEVEL LEVEL
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
Project Title
500
500
1200
1450
1450
Drawing Title
MASS CONCRETE FOUNDATION GRADE
ST2. CONCRETE TO BE RAMMED AS
MASS CONCRETE FOUNDATION GRADE FILLING PROCEEDS. 6m & 8m HEAVY DUTY HINGED LIGHTING
ST2. CONCRETE TO BE RAMMED AS
FILLING PROCEEDS.
COLUMN FOUNDATION DETAILS
TYPICAL 6m ABACUS T067RLH HEAVY DUTY TYPICAL 8m ABACUS T087RLH HEAVY DUTY Site Coordinates
N/A
ELR
N/A
Chainage
N/A
Drawing No. Revision
FORMATION LEVEL
DEPTH TO SUIT
DEPTH TO SUIT
Property and infrastructure
600 Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
Project Title
INFRASTRUCTURE ACCESS POINTS
ALL EXCAVATED 450
1000 MATERIAL TO BE 225 225 BEST PRACTICE DESIGN GUIDE
FILLED WITH CONCRETE REINSTATED IN 150mm STANDARD DETAILS
ON 25mm SAND 2000 COMPACTED LAYERS
BLINDING SECTION B-B ALTERNATIVE Drawing Title
SECTION A-A GRP GUARD RAIL ELEVATION (1:20) POST FIXING DETAIL (1:20) HEAVY DUTY GRP HANDRAIL DETAILS
17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check
Client
capping layer
Type 1 granular sub-base material to S.H.W. 800 150mm thick AC 32 dense base 100/150 to BS EN 13108-1
capping layer
Capping layer - class 6F5 (or 6F2) capping material
Lotrack 2800 geotextile (or equivalent) Capping layer - class 6F5 (or 6F2) capping material
Client
SUBGRADE CBR (%) 2.5 3 4 5 7 10 15 T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
CAPPING (SERIES 600) mm 250 240 220 210 190 170 150
TYPICAL ASPHALT CONCRETE
TOTAL THICKNESS mm 600 560 490 450 410 350 300
ACCESS ROAD DETAILS
Finished level
Pavement
Depth of
17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check
Client
Project Title
INFRASTRUCTURE ACCESS POINTS
BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title
TYPICAL CONCRETE
HARDSTANDING / ACCESS ROAD
DETAILS
Drawn By Name Sig. Date
L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
J.W. J.WHITE 17.12.14
Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
NTS @ A3 1 1
Site Coordinates ELR Chainage
N/A N/A N/A
Drawing No.
Galvanized mild steel barrier guard ALL WORKS TO BE COMPLETED IN ACCORDANCE WITH
rail complete with guard rail system Galvanized mild steel barrier guard THE REQUIREMENTS OF NETWORK RAIL COMPANY
to be installed strictly in accordance rail complete with 127x76UB post PROCEDURES
with manufacturers details. and base plate. Guard rail system to
100mm wide 8mm be installed strictly in accordance
Thick stiffener with manufacturers details.
600
600
Notes:
1. Fishtailed end unit to be fixed to
all barrier ends.
412
412
127x76 UB
2. Post centres as per
manufacturers detail, but a
minimum of 2m centres. A A
12mm Thick
base plate - see detail
formation level
Mass concrete foundation grade
formation level
Mass concrete foundation grade
Depth to suit
Depth to suit
ST2. Concrete to be rammed as ST2. Concrete to be rammed as
filling proceeds. filling proceeds.
17.12.
450 450 01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
ROOTED ARMCO BARRIER DETAIL ARMCO BARRIER RIDGID DUCT DETAIL Client
Check
(PREFERRED OPTION)
SECTION A-A
600
45
B base plate - see detail B 60 STANDARD DETAILS
Drawing Title
250
100mm wide
8mm Thick ARMCO BARRIER DETAILS
stiffener
Concrete
Base/Apron
610
1000
YPL010m powder coated)
of concrete
50mm Grass: +50mm (with 50mm chamfer)
200 200 chamfer Asphalt conc.: -60mm
Concrete: integral with slab
785 G.L.
300
Concrete to be grade ST4
to BS 8500 and BSEN 206.
20mm clean
150
5mm box section,
galvanised. chippings
6mm base plate complete compacted Concrete to be grade ST4 200 200 Concrete to be grade ST4
150
with water outlet to BS 8500 and BSEN 206. to BS 8500 and BSEN 206.
Client
Bollard constructed
Property and infrastructure
1300
Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
with concrete. Painted
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
with yellow and black
915
Existing landscape
50mm
200mm
150mm
min.
ST2 Concrete 200mm 200mm
EDGING KERB
17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check
Client
150
60
125mm
70
125x150mm dropped
75
150
Bullnosed lightweight Property and infrastructure
recycled polymer kerb Special Projects, 2nd Floor Clemence House, Mellor Road,
25
150 min
approved product) For road construction T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
150
details
Project Title
ST2 Concrete
275
INFRASTRUCTURE ACCESS POINTS
ST2 Concrete 350 BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
DROPPED KERB Drawing Title
Not for use on public highways
HALF BATTER KERB
LIGHTWEIGHT KERBING DETAILS -
(DURAKERBS)
60
125
Kerb face
60
60
15 125 x 150mm P.C.C. bull nosed
125 x 255mm P.C.C. kerb type BN to BS EN 1340
15
200
150
150
ST1 concrete half battered kerb type 15mm min mortar
15
bed and haunch HB2 to BS EN 1340 (see note 4)
300 15mm min mortar 300
ST1 concrete bed 125
(see note 4) 305
and haunch
555
70
50
1340
160
15
230
25
C'way
415
17.12.
100
100
60
60
01 L.Z. First issue J.W.
2014
115
250 250
445
bed and haunch bed and haunch Rev Date Name Description of Revisions
Rev'
Check
Project Title
INFRASTRUCTURE ACCESS POINTS
NOTES BEST PRACTICE DESIGN GUIDE
1. Do not scale off this drawing. STANDARD DETAILS
2. All dimensions in millimetres unless otherwise stated.
3. Unless specified otherwise steel dowel bars shall be used where Drawing Title
kerb bedding / backing is laid separately. If used dowel bars shall be
300mm long 20mm diameter mild steel at 450mm centres.
4. Mortar only to be used when kerb laid on cured concrete. PRE-CAST CONCRETE KERBING
Designation (i) mortar to be used. DETAILS
5. All kerbs to be precast concrete.
AQUA.
Belmont House,
Garnett Place,
Skelmersdale,
Lancashire,
WN8 9UB.
Tel 01695 51933.
Email. sales@aquafab.co.uk.
Fax. 01695 51891.
Web. www.aquafab.co.uk
Entry to be
Galvanised solid site specific
lid with frame Finished ground
CL (Cover Level) level
HDPE chamber
Incoming
backfill.
site specific
Entry to be
pipes
17.12.
Depth to be site specific
X X Rev
Client
Date Name Description of Revisions
Check
100 Incoming
pipes
site specific
Entry to be
Incoming
100
pipes
IL
300
Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
Clean 20/40mm single
T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
sized aggregate or 40mm
100
GL
750
Client
Geotextile
Geotextile
3500
Geotextile
Geotextile
BL Property and infrastructure
Special Projects, 2nd Floor Clemence House, Mellor Road,
Cheadle Hulme. SK8 5AT Web: www.capita.co.uk/infrastructure
1050mm diameter PCC
Soakaway rings with 75mm T: +44 (0) 161 488 1500 E: Special.Projects@Capita.co.uk
Project Title
INFRASTRUCTURE ACCESS POINTS
Geotextile Geotextile Geotextile BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
GEN 3 concrete ring Drawing Title
foundations for the 300 (min) 300 (min)
soakaway rings
Clean 20/40mm single sized aggregate
or 40mm gravel surround / base infill to
TYPICAL SOAKWAY DETAIL
soakaway. TRAFFICKED AREAS
100
130
or removed with hand tools
40
60
Sub-base Surface course
Binder course
Base course
L
FIL
min
100
CUT
Client
1 Project Title
10
All joints to be saw INFRASTRUCTURE ACCESS POINTS
Detail design 200mm cut and sealed
Sub-base Transition slab 20mm mild steel bars BEST PRACTICE DESIGN GUIDE
1m long at 300 centres.
STANDARD DETAILS
TRANSITION JOINT BETWEEN CONCRETE FOOTWAY TIE-IN DETAIL Drawing Title
35
100 - load class A15
150 - load class B125 Concrete Concrete
Varies
* 200 - load class D400 hardstanding hardstanding
60
*
Min C25/30 concrete Min C25/30 concrete
bedding and haunch. bedding and haunch.
Client
Project Title
INFRASTRUCTURE ACCESS POINTS
BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title
150
160
PROCEDURES
210
430
750
330
150
400
800
500
150
210
160
150
150 375 150
150 350 150 Formation
Formation
drainage slot drainage slot
375
650
PLAN OF P.C. COVER SLAB FOR PLAN OF P.C. COVER SLAB FOR
500mm * 350mm GRATING AND FRAME 430mm * 370mm GRATING AND FRAME 01
17.12.
L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
NOTES
Check
even. Portland cement is to be used when the 2. Gratings shall be available with either left or right
Carriageway
ambient temperature can be expected to fall hand hinges as viewed when facing the kerb.
Hinged end to be nearest on-coming traffic. The
grating shall be captive within the frame.
330 min
Varies
Formation 3. All in-situ concrete to be medium workability / Special Projects, 2nd Floor Clemence House, Mellor Road,
150
Flexcell minimum cement content 300 kg/m3 and 0.60 Project Title
joint maximum water/cement ratio. Workability to suit
method of manufacture. INFRASTRUCTURE ACCESS POINTS
BEST PRACTICE DESIGN GUIDE
150mm diameter 5. Dimensions of opening on upper face of PC cover
outlet STANDARD DETAILS
slab shall be the same as the clear opening at the
450*750*150 concrete street underside of the frame. Tolerance is permitted on Drawing Title
gully to BS5911 Part 6 all other cover slab dimensions
CONCRETE ROAD GULLY
Stopper &
chain FOR ACCESS ROAD
Flexcell
joint
Drawn By Name Sig. Date
L.Z. L.ZEMAN 17.12.14
Checked By Name Sig. Date
150mm bed and J.W. J.WHITE 17.12.14
150mm bed and surround
concrete ST4 surround concrete ST4 Approved By Name Sig. Date
J.W. J.WHITE 17.12.14
Scale Sheet of
1 :10 @ A3 1 1
CONCRETE Site Coordinates
N/A
ELR
N/A
Chainage
N/A
17.12.
01 L.Z. First issue J.W.
2014
Positioned on
filter access Rev Date Name Description of Revisions
Rev'
Check
unit
200mm thick R.C. capping slab Client
reinforced with 2 layers of A393
mesh 1 top + 1 bottom (40mm cover)
1000 over hang 1000 over hang
all round 75mm thick layer of all round
polystyrene
Project Title
TYPICAL SECTION THROUGH OIL INFRASTRUCTURE ACCESS POINTS
SEPARATOR IN TRAFFICKED AREA BEST PRACTICE DESIGN GUIDE
STANDARD DETAILS
Drawing Title
Surface to be reinstated
to match existing
Finished ground
level
500
20mm Single size stone
17.12.
01 L.Z. First issue J.W.
2014
Rev'
Rev Date Name Description of Revisions
Check
Client
150
pipe (pipes to be laid with
perforations at invert). Terram 1000 lining or similar approved product.
Project Title
INFRASTRUCTURE ACCESS POINTS
50
150
BEST PRACTICE DESIGN GUIDE
150
STANDARD DETAILS
Geotextile filter membrane on Drawing Title