This document summarizes the load analysis of foundation bolts for an SRP skid structure. It provides the bolt size, material properties, loads from analysis, and calculates the shear and tensile capacities of the bolts. It determines that the bolts are safe based on the utility ratios and combined load ratio being less than specified limits.
This document summarizes the load analysis of foundation bolts for an SRP skid structure. It provides the bolt size, material properties, loads from analysis, and calculates the shear and tensile capacities of the bolts. It determines that the bolts are safe based on the utility ratios and combined load ratio being less than specified limits.
This document summarizes the load analysis of foundation bolts for an SRP skid structure. It provides the bolt size, material properties, loads from analysis, and calculates the shear and tensile capacities of the bolts. It determines that the bolts are safe based on the utility ratios and combined load ratio being less than specified limits.
Node No - 35 UNIT Reference Bolt size = M20 Area of bolt, Ab = 169 mm² Tensile force, Fy = 43 KN STAAD analysis Shear force, Fx = 54 KN STAAD analysis Shear force, Fz = 0 KN STAAD analysis Resultant Shear force, V = 54.00 KN Tensile force, T = 43.00 KN No of bolt, n = 2 Material = Gr 8.8 Yield strength, Fy = 640 N/mm² futa = min(fu, 1.9*fy, 125 [ksi]) Sec. D.5.1.2 futa = 800 N/mm² Tensile Strength, Fu = 800 N/mm² Shear Capacity, Vc = n x Φ x Ab x 0.5 x Fu Eq. D-20 Vc = 101.4 KN Utility Ratio = 0.53 HENCE SAFE = V < Vc Tensile Capacity, Tc = n x Φ x Ab x 0.75 x Futa Eq. D-3 Tc = 152.10 KN Utility Ratio = 0.28 HENCE SAFE = T < Tc Combined Ratio V/Vc+T/Tc = 0.82 < 1.4 = HENCE SAFE