Office of the President

NATIONAL HOUSING AUTHORITY


Elliptical Road, Diliman, Quezon City

STA. MONICA HOMES


BRGY. STA. ASUNCION, SAN NICOLAS, ILOCOS NORTE

HOUSE PLANS

CSE BUILDERS
Phase 6, Blk 1, Lot 10, Eastwood, Greenview Subd. San Isidro, Rodriguez, Rizal
(Unit 308, F&L Building, #2211, Commonwealth Ave, Quezon City - Office Address)

PROPOSED SITE

LUZON
PROPOSED SITE

N N
DRAWN NOT TO SCALE LOCATION MAP DRAWN NOT TO SCALE VICINITY MAP
TABLE OF CONTENTS Republic of the Philippines
OFFICE OF THE BUILDING OFFICIAL
SHEET
SHEET TITLE / CONTENTS
NUMBER

ARCHITECTURAL

A - 01 SITE DEVELOPMENT OF TWO UNITS / PERSPECTIVE


/ VICINITY MAP
District / City / Municipality
A - 02 FLOOR PLANS & ELEVATIONS

A - 03 SECTIONS / ROOF PLAN /


REFLECTED CEILING PLANS

FLOOR PATTERN LAYOUT / OPENING SCHEDULE


A - 04 TOILET DETAILS / SCHEDULE OF FLOOR FINISHES

A - 05 STAIR DETAILS

STRUCTURAL LAND USE & ZONING


GENERAL CONSTRUCTION NOTES
S - 01 MIN. EMBEDMENT & LAP SPLICES
STANDARD END HOOK DETAILS
COLUMN SPLICES & SPECIAL TIES
S - 02 COLUMN DETAIL / FOOTING DETAILS
STANDARD HOOK DETAILS

S - 03 BEAM DETAIL / RC BARS SCHEDULE


CANTILEVER SLAB DETAILS

S - 04 TYPICAL DETAIL OF CONTINUOS BEAM


TYPICAL DETAIL OF SLAB
FOUNDATION PLAN LINE & GRADE
S - 05 ROOF FRAMING PLAN
2F FLOOR FRAMING PLAN, DETAILED SECTION
WALL FOOTING DETAILS
TYPICAL WALL FOOTING COLUMN
S - 06 CONNECTIONS / TYPICAL BEAM TO COLUMN CONNECTION
SCHEDULE OF BEAMS / CONCRETE LEDGE DETAIL
DOOR JAMB DETIAL
SECTION DETAILS OF TYPICAL WALLS & OPENING REINFORCEMENT
DETAILED PLAN OF VERTICAL REINFORCEMENTAT SIDES OF OPENING
S - 07 WALLS & OPENING SECTION
PLAN OF WINDOW OPENING
SECTION DETAIL ABOVE OPENING
SECTION DETIAL OF CONCRETE SILL BELOW OPENING

S - 08 ROOFING DETAILS

ARCHITECTURAL

ELECTRICAL
A PERSPECTIVE ELECTRICAL NOTES/ELECTRICAL LAYOUT
E - 01
A 01 SCALE NTS PLAN/SINGLE LINE DIAGRAM/ LOAD SCHEDULE

1 2 3 PLUMBING
STRUCTURAL
16000 P - 01 SANITARY LAYOUT/ SANITARY ISOMETRIC
LAYOUT/ GENERAL NOTES/ SEPTIC VAULT DETAIL
8000 8000
STORM DRAINAGE LAYOUT/ STORM DRAINAGE
2100 5900 5900 2100 P - 02 ISOMETRIC LAYOUT/ WATER LINE LAYOUT/
900 5000 5000 900 WATER LINE ISOMETRIC

PROPERTY LINE
FORT ILOCANDIA
ER
RESORT AND CASINO OP
1100

PR

1100
AS
PROPERTY LINE

LA FELIZA BED PROPOSED SITE ICOL NORTHWESTERN


NN
AND BREAKFAST SA UNIVERSITY
GUTTER GUTTER (STA. MONICA HOMES) TO
ECOTOURISM SANITARY
900

900

A SOUTH PARK

AD
CHINA SEA

RO
BRGY. STA. ASUNCION,

AY

AD
RO
SAN NICOLAS, ILOCOS NORTE

AO

EXC
6,34

LUD
ARE
3.00

ED
A
SQM
-P
G
B

OA
LA
ASUNCION
ELEMENTARY
10000
7800
6000

10000
7800
6000

SCHOOL
AD
O
LR
IA ELECTRICAL
NC
VI
O
PR
PLAZA DEL NORTE
PROPERTY LINE

HOTEL AND

C CONVENTION CENTER
900

900

GUTTER GUTTER
1100

1100

SUBA BEACH
PROPERTY LINE ROAD MALACAÑANG SUBA ELEMENTARY
OF THE NORTH SCHOOL
2100 900 5000 5000 900 2100
8000 8000 PAOAY LAKE MECHANICAL
16000

C SITE DEVELOPMENT PLAN D VICINITY MAP


A 01 SCALE 1:100 A 01 SCALE NTS

ELECTRONICS

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
A
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL


PERSPECTIVE REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. SITE DEVELOPMENT PLAN
VICINITY MAP

01
DUPLEX HOUSING UNIT EMERITO JACOB DECENA DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA

05
ARCHITECT
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER
REG. NO. 0015472 DATE DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 1291299 DATE
1 2 3 0.40MM PREPAINTED RIB TYPE
A B C
158
LO NG S P A N G I SH E E TS . W I TH
11800 1 50 mm X3 00 mm P V C G U TT E R 1100 7800 1100
TOP OF FIREWALL 900 5000 5000 900 900 2100 300
(+07.20 mts.)

300
19mmTHK. SENEPA IN
SEMI-GLOSS LATEX PAINT FINISH

1800

2100
300
15°
1 2 3

10°
2ND FLR. CL.
600 600 600
(+05.40 mts.)
S MO O TH CE ME NT PL AS TE R I N

50

50

50
SEMI GLOSS LATEX PAINT FINISH 400 400
16000 ( W H I T E )

2500
8000 8000

7200

7200
3000 5000 5000 3000

6900
L E D G E

3900
6300
2950 2050 2050 2950 2ND FLOOR LINE
(+02.90 mts.) 600 600 600
S MO O TH CE ME NT PL AS TE R I N

50

50

50
SEMI GLOSS LATEX PAINT FINISH
PROPERTY LINE ( W H I T E )

2700
PROPERTY LINE
2000

2000
GROUND FLOOR LINE

1200
ROOF LINE ROOF LINE (+00.20 mts.)

A
W W W W

200
2 2 2 2 FIN. GROUND LINE
(+00.00 mts.)

G W W

2050
2100

1 1

FAMILY AREA FAMILY AREA


2950

2950
A-02
FRONT ELEVATION LEFT SIDE ELEVATION
+02.90mts +02.90mts
F.F.L. F.F.L.

B W
1
BEDROOM 2
+02.90mts
D
4
3 3
D
4
BEDROOM 2
+02.90mts
W
1
C
A 02 SCALE 1:100
D
A 02 SCALE 1:100
F.F.L. F.F.L.
10000

10000
6000

6000
4 4

5 5
D 6 6 D
W W
1 4 7 7 4 1

3950
3900

8 8

3 2 1 C B A
3050

3050
9 9

10 10

11 11
BEDROOM 1
12 12 +02.90mts
F.F.L.
0.40MM PRE PAINTED RIB TYPE
W W LO NG S P A N G I SH E E TS . W I TH
PROPERTY LINE

1 BEDROOM 1 DN DN
1 11800 1100 250
7800 1100
+02.90mts
1 50 mm X3 00 mm P V C G U TT E R

C
F.F.L. 14 13 13 14

TOP OF FIREWALL 900 5000 5000 900 17 2850 900


W W W W W W
2 1 1 1 1 2 (+07.20 mts.)
2000

2000

300
ROOF LINE ROOF LINE 19mmTHK. SENEPA IN
SEMI-GLOSS LATEX PAINT FINISH

300
1800

2100
AS APPROVED BY THE ARCHITECT

15°
10°
PROPERTY LINE
2ND FLR. CL.
600
1075 1000 1000 500 (+05.40 mts.)
S MO O TH CE ME NT PL AS TE R I N

50
3000 2850 2150 1575 3425 3000 SEMI GLOSS LATEX PAINT FINISH
( W H I T E )

2500
8000 8000 400

16000

7200

7200
6900
L E D G E

3900
2ND FLOOR LINE

SECOND FLR.PLAN
(+02.90 mts.) 600

B
A-02
H

50
S MO O TH CE ME NT PL AS TE R I N
A 02 SCALE 1:100

2700
SEMI GLOSS LATEX PAINT FINISH
( W H I T E )
GROUND FLOOR LINE

1 2 3

1200
(+00.20 mts.)

PROPOSED

200
FIN. GROUND LINE

COLUMNS
(+00.00 mts.)

16000
8000 8000
3000 5000 5000 3000 E REAR ELEVATION F RIGHT SIDE ELEVATION
3125 1875 1875 3125 A 02 SCALE 1:100 A 02 SCALE 1:100

PROPERTY LINE

1 2 3 C B A
PROPERTY LINE
2000

2000

ROOF LINE ROOF LINE


11800 7800
A
W W W W
4 5 5 4

TOP OF FIREWALL 900 5000 5000 900 900 3900 2100 900
(+07.20 mts.)

G
REF REF
2100

2100

D D
A-02 -200mm
2 KITCHEN D TOILET TOILET -25mm D KITCHEN 2
-200mm
+00.20mts -25mm +00.175mts +00.175mts +00.20mts
3

B
F.F.L. F.F.L. F.F.L. 3 F.F.L.

1800

1800
VERIFY STRUCTURAL VERIFY STRUCTURAL
1 2 3 3 2 1
VERIFY STRUCTURAL
DINING AREA
UP UP
DINING AREA 2ND FLR. CL.
10000

10000
6000

6000

+00.20mts
F.F.L. 4 4
+00.20mts
F.F.L. (+05.40 mts.)
5 5
W 6 6
W
3 3
7 7

6000
2500

2500
3900

3900

8 8

LIVING AREA LIVING AREA

7200
TV TV
+00.20mts +00.20mts
F.F.L. F.F.L.

2ND FLOOR LINE BEDROOM 1 FAMILY AREA FAMILY AREA BEDROOM 1 BEDROOM 2 BEDROOM 1
PROPERTY LINE

W W
3 D W W D 3 (+02.90 mts.)

C
CARPORT 1 1 CARPORT
1 1
+00.00mts +00.00mts
F.F.L. -200mm -200mm F.F.L.
W W
2 2
2700

2700
FOOTPATH FOOTPATH
2000

2000

+00.00mts +00.00mts
ROOF LINE F.F.L. F.F.L. ROOF LINE GROUND FLOOR LINE

1000
(+00.20 mts.)
KITCHEN T&B T&B KITCHEN DINING AREA
200

PROPERTY LINE FIN. GROUND LINE


(+00.00 mts.)

2675 1200 1125 1125 1200 2675


3000 5000 5000 3000
8000 8000
16000

G LONGITUDINAL SECTION H CROSS SECTION


GROUND FLR.PLAN
A-02
H

A A 02 SCALE 1:100 A 02 SCALE 1:100


A 02 SCALE 1:100
PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
A
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL FLOOR PLANS REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. ELEVATIONS
SECTIONS

02
DUPLEX HOUSING UNIT EMERITO JACOB DECENA DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA

05
ARCHITECT
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER
REG. NO. 0015472 DATE DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 1291299 DATE
LEGENDS AND SYMBOLS

7W LED BULB RECESSED DOWN


LIGHT HALOGEN (WARM WHITE)
AS PER APPROVED SAMPLE

6 m m T HK O RD I N AR Y- RES I S TA N T
FICEM BOARD PAINTED FINISH ON
C-01 19X50MM CEILING JOIST @600mm
O . C S P A C I N G
1 2 3 1 2 3
6 m m T H K M O I S T U R E - RE S I S T A N T
C-02 FICEM BOARD PAINTED FINISH ON 16000 16000
19X50MM CEILING JOIST @600mm 8000 8000 8000 8000
O . C S P A C I N G 3000 3000
2100 5900 5900 2100 5000 5000
900 5000 5000 900

PROPERTY LINE PROPERTY LINE

1100

1100
PROPERTY LINE

PROPERTY LINE
2000

2000
GUTTER GUTTER ROOF LINE ROOF LINE

900

900
C-02 C-02

A A
X W U V
BUILDING LINE

2050

2050
BEDROOM 2 BEDROOM 2

3950

3950
FAMILY AREA FAMILY AREA
C-01 C-01

4850
N Q

B
O T

B
10000

10000

10000

10000
7800
6000

6000
7800

6000

6000
C-01 C-01
W U

3950

3950
2950
P S
BEDROOM 1 M R BEDROOM 1
3850

C-01 C-01
2950

PROPERTY LINE

PROPERTY LINE
DN

C BUILDING LINE C
900

900
C-02 C-02
GUTTER GUTTER X W U V

2000

2000
ROOF LINE ROOF LINE
1100

1100
PROPERTY LINE PROPERTY LINE

2100 900 5000 5000 900 2100


8000 8000 3000 2850 2150 1575 3425 3000
16000 8000 8000
16000

1 2 3 B 2F REFLECTED CEILING PLAN


C ROOF PLAN A 03 SCALE 1:100
A 03 SCALE 1:100

A
C-02 C-02

C D J I

B
B H

C-01 C-01

A G

A GF REFLECTED CEILING PLAN


A 03 SCALE 1:100

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
A
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. ROOF PLAN
REFLECTED CEILING PLANS

03
DUPLEX HOUSING UNIT EMERITO JACOB DECENA DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA

05
ARCHITECT
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER
REG. NO. 0015472 DATE DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 1291299 DATE
1 2 3
1 2
1950 1450
16000
150 1700 100
8000 8000
3000 5000 5000 3000 150 950
600 1 2
1950 2100
PROPERTY LINE 150 1700 100 100 1850 150

PROPERTY LINE
450 950 300 300X300MM NON-SKID
2000

2000
ROOF LINE ROOF LINE HOMOGENEOUS FLOOR
TILES 300X300MM
300X300MM
A TOILET CEILING LINE

150
TOILET CEILING LINE HOMOGENEOUS
HOMOGENEOUS (+02.60 mts.)

600 275
(+02.60 mts.) WALL TILES
F-04 F-04
WALL TILES
2050

2050
BEDROOM 2 BEDROOM 2

1225
1225
A

1625
F-02 FAMILY AREA FAMILY AREA F-02 LAV
GRAB BAR

2100

2100
GRAB BAR

1850
B

2425

2600

2600
2600

2600
10000

10000
6000

6000
-25mm
2% slope LAV

1550
450

1200
1200
B TOILET FLOOR LINE TOILET FLOOR LINE
3950

3950

100

175 800
F-02 F-04 F-04 F-02

800

800
(+00.175 mts.) (+00.175 mts.)

BEDROOM 1 BEDROOM 1
400 T&B

175
175

175
FIN. GROUND LINE FIN. GROUND LINE
PROPERTY LINE

DN DN
(+00.00 mts.) (+00.00 mts.)

C
2000

2000
ROOF LINE ROOF LINE
150 1700 100

PROPERTY LINE TOILET


C FLOOR PLAN D ELEVATION @ A E ELEVATION @ B
3000 2850 2150 1575 3425 3000 A 04 SCALE 1:60 A 04 SCALE 1:60 A 04 SCALE 1:60
8000 8000
16000
1000 900 700 700 800
50 900 50 50 800 50 50 600 50 50 600 50 SPECIFICATIONS: 50 700 50
SPECIFICATIONS: SPECIFICATIONS: SPECIFICATIONS:
-PVC PANEL DOOR SET
-44mm. THK. FROM 50X100mm. KD. -44mm. THK. FROM 50X100mm. KD. -44mm. THK. FROM 50X100mm. KD.

50

50

50
WITH JAMB AND HINGES

150

150
SOLID WOOD FRAMES SOLID WOOD FRAMES SOLID WOOD FRAMES
-44mm. THK. FROM 50X100mm. KD.
B 2F FLOOR PATTERN LAYOUT -44mm. THK. FROM 50X150mm. KD.
BOTTOM STILE
-30mm. THK. KD. SOLID WOODPANEL
-44mm. THK. FROM 50X150mm. KD.
BOTTOM STILE
-30mm. THK. KD. SOLID WOODPANEL
BOTTOM STILE
-6mm. THK. PLYWOOD PANEL
A 04 SCALE 1:100 -USE 50X150mm SOLID WOOD JAMB, KD. -USE 50X150mm SOLID WOOD JAMB, KD. -USE 50X100mm. SOLID WOOD JAMB,
-ALL WOOD IN WOODSTAIN VARNISH FINISH -ALL WOOD IN WOODSTAIN VARNISH FINISH KD.
-ALL WOOD IN WOODSTAIN

2150

2150

2150

2150

2150
2100

2100

2100
1800

1800
VARNISH FINISH
REQUIREMENTS: TWO (2) SETS REQUIREMENTS: FOUR (4) SETS
REQUIREMENTS: TWO (2) SETS
LOCATION: REQUIREMENTS: TWO (2) SETS LOCATION: BEDROOM 1 & 2
KITCHEN
LOCATION: MAIN DOOR (LIVING AREA)
1 2 3 HARDWARES:
HARDWARES:
4 PCS. SS. DOOR HINGES
LOCATION:
HARDWARES:
TOILET & BATH HARDWARES:
4 PCS. SS. DOOR HINGES
1 SET STAINLESS STEEL
4 PCS. SS. DOOR HINGES 1 SET STAINLESS STEEL 1 SET STAINLESS STEEL DOOR KNOB

150

150
DOOR KNOB DOOR KNOB
1 SET STAINLESS STEEL
DOOR KNOB OUTSIDE VIEW INSIDE VIEW

D HINGED D HINGED D HINGED D HINGED


1 WOOD PANEL DOOR 2 WOOD PANEL DOOR 3 FLUSH DOOR 4 FLUSH DOOR

700 1350 600 2000


50 600 50 50 650 50 500 50 500 1000 500 600
650 50 50 500 50

A 50 550 50 550 50

50 550 50 550 50
SPECIFICATIONS: SPECIFICATIONS: SPECIFICATIONS:
50X50mm. PVC AWNING 50X50mm. PVC FIXED/ 50X50mm. PVC AWNING

600
SPECIFICATIONS: SPECIFICATIONS: WINDOW w/ 6MM THK. CLEAR CASEMENT WINDOW w/ 6MM WINDOW w/ 6MM THK. CLEAR

950
50X50mm. PVC AWNING w/ 50X50mm. PVC SLIDING GLASS PANEL. PROVIDE THK. CLEAR GLASS PANEL. GLASS PANEL. PROVIDE
1250

1250

1250
6MM THK. CLEAR GLASS WINDOW w/ 6MM THK. CLEAR WEATHER STRIPPING. PROVIDE WEATHER STRIPPING. WEATHER STRIPPING.
F-03 F-03 PANEL. PROVIDE WEATHER GLASS PANEL. PROVIDE
STRIPPING. WEATHER STRIPPING. REQUIREMENTS: FOUR (4) SETS REQUIREMENTS: TWO (2) SETS REQUIREMENTS: TWO(2) SETS
B
2150

2150

2150

2150

2150
LOCATION: LIVING AREA LOCATION: KITCHEN LOCATION: TOILET AND BATH
REQUIREMENTS: FOURTEEN (14) SETS REQUIREMENTS: EIGHT (8) SETS

1550
LOCATION: LIVING AREA LOCATION: BEDROOM 1 & 2

1200
BEDROOM FAMILY AREA
900

900

900
STAIRCASE LIVING AREA
F-01 F-01

W AWNING W SLIDING W AWNING W FIXED/CASEMENT W AWNING


1 PVC WINDOW 2 PVC WINDOW 3 PVC WINDOW 4 PVC WINDOW 5 PVC WINDOW
C 1488 1488
E OPENING SCHEDULE
A 04 SCALE 1:50 M

LEGENDS AND SYMBOLS


F-01 F-02 F-03 F-04
600mmX600mm 300mmX300mm VINYL 300mmX600mm
A GF FLOOR PATTERN LAYOUT CERAMIC VITRIFIED T I L E S
300X300 mm NON-SKID
A 04 SCALE 1:100 HO MO GE NE OU S T IL ES CERAMIC VITRIFIED
UNGLAZED TILES UNGLAZED TILES

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

PROPOSED TWO STOREY 60 SQM.


PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL FLOOR PATTERN LAYOUT
OPENING SCHEDULE
TOILET DETAILS
SCHEDULE OF FLOOR FINISHES
REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
A
DUPLEX HOUSING UNIT ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA EMERITO JACOB DECENA
ARCHITECT
DATE:
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER, 04
LOCATION:
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE
GENERAL MANAGER
REG. NO.
LIC. NO.
0015472
1291299
DATE
DATE
DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
05
B C B C
4000 3900 50X100X2MM THK. BI TUBULAR HANDRAIL
3750 150 AND VERTICAL SUPPORTS
1000 2750 150 IN EPOXY PRIMER PAINT WITH
1000 1750 1000 AUTOMOTIVE PAINTED FINISH

10
DIVIDED INTO 7 EQUAL
STEPS @ 250 MM EACH

5
R.C STAIR
25X25X2MM THK. BI IN EPOXY
PRIMER PAINT WITH

50
1000 150
2

2
AUTOMATIVE PAINT FINISH.

1000 75

11
10

12
9
4

8
1075
50X100X2MM THK BI TUBULAR

15
HANDRAIL

1650

15
0
1825

0
1750

EQUAL STEPS @
DIVIDED INTO 2

1975
250 MM EACH

14 13
3
3

500

DN
2

11

975
1

C C 50

38
15
TYPICAL RISER
10

0
UP

192
A-05 A-05

154
FROM STEP 3-14
3750 150 1000 2750 150
9

15
0
3900 3900

15
2F STAIR PLAN

0
GF STAIR PLAN
A
A 05 SCALE 1:40
B
A 05 SCALE 1:40 8
RC STAIR (VERIFY STRUCTURAL)

B
3900
C 7
74
10 STAIR SOFFIT IN SMOOTH PLAIN
850
CEMENT PAINTED FINISH
1150
Line c Varies Varies

2 50
4 5 6 7 8 9 10 11 12
250

180

200
Bar A
A A

170
12Ø-@100mm O.C.
Bar C 300
STAIR DETAILED SECTION
1000

1286
E
52
7 12Ø-@100mm O.C.
TYPICAL A 05 SCALE 1:10
3 13 TREAD
2 14
1 Line a 200
Line b (Below)
UP
1000 C DETAILED PLAN 802 50X100X2MM THK BI TUBULAR
A 05 SCALE 1:30 HANDRAIL AND VERTICAL SUPPORTS
IN EPOXY PRIMER PAINT WITH
AUTOMOTIVE PAINTED FINISH
1150
14 00
2F LEVEL 26
25X25X2MM THK. BI TUBULAR

900
13
180

Temperature bars: Bar C 12


IN EPOXY PRIMER PAINT WITH
485
180

10Ø-@300mm O.C. (At Center Only) AUTOMATIVE PAINT FINISH.


11 14 2ND FLR. FINISH LINE
125

300
13
Bar B
250
10 2B1a
Bar A 9 12Ø-@100mm O.C. 11
12

51.5
°
8 Line b 10
180

1000
Line a

1916
9
7
Co

Line c
8
ve
12

2000
2700
r2
5

7
2700

850 STAIR SOFFIT IN SMOOTH


0

5
1250

6
PLAIN CEMENT PAINTED
4 5
FINISH
4
3
Bar B

1100
200 200 192 192
3
2 150 D

784
2
1 A-05 R.C STAIR

400
Stirrups: 10Ø-@200mm O.C. 1
900

200 GROUND FLR. FINISH LINE


GF LEVEL

4pcs-10Ø D SECTION A-A


ELEVATION THRU 'D'
600

A 05 SCALE 1:30
F
220

600 16Ø-@150mm O.C. G BAR DETAIL OF STAIR A 05 SCALE 1:40

A 05 SCALE 1:30
Footing 600X1000

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
A
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. STAIR DETAILS

05
DUPLEX HOUSING UNIT EMERITO JACOB DECENA DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA

05
ARCHITECT
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER
REG. NO. 0015472 DATE DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 1291299 DATE
GENERAL CONSTRUCTION NOTES
1.0 GENERAL 5.0 LAPS AND SPLICES
IN THE INTERPRETATION OF THESE DRAWINGS, INDICATED DIMENSIONS SHALL GOVERN AND LAP SPLICES IN COLUMNS, WHEN REQUIRED SHALL BE PERMITTED ONLY WITHIN THE CETER HALF MINIMUM EMBEDMENT AND LAP SPLICES
DISTANCES OR SIZES SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. OF THE COLUMN LENGTHS AND SHALL BE PROPORTIONED AS TENSION SPLICES AND IN NO CASE
SHALL THE LAP BE LOCATED CLOSER THAN A DISTANCE EQUAL TO THE MAXIMUM COLUMN
FEATURES OF CONSTRUCTION SHOWN ARE TYPICAL AND THEY SHALL APPLY GENERALLY DIMENSION FROM THE FACE OF THE BEAM COLUMN JOINT. PROVIDE EXTTRA TRANSVERSE F'c = 21 Mpa TO 41.37 Mpa
THROUGHOUT FOR SIMILAR CONDITIONS. MODIFY DETAILS AS DIRECTED BY THE DESIGN REINFORCENT OF THE SAME SIZE AND ARRANGEMENT INDICATED IN THE COLUMN SECTION
ENGINEER TO MEET SPECIAL CONDITION. THROUGHOUT THE LENGTH OF THE SPLICE. EMBEDMENT CLASS A CLASS B CLASS C TOP BARS (MIN. 300mm CONC. CAST BELOW)
BAR STRAIGHT LENGHT E TENSION TENSION TENSION CLASS A CLASS B CLASS C
ALL EXISTING CONDITIONS SHALL BE VERIFIED AT THE SITE BY THE CONTRACTOR BEFORE GENERALLY, NO LAP SPLICE SHALL BE PERMITTED ON BEAMS AND GIRDERS AT POINTS WHERE STRAIGHT
SIZES EMBEDMENT W/ STD. END COMPRESSION SPLICE SPLICE TENSION TENSION TENSION
COMMENCING WITH THE WORK BEFORE COMMENCING WITH THE WORK. ANY DISCREPANCIES THE CRITICAL BENDING STRESS OCCUR. IN ADDITION, FOR GIRDERS, NO LAP SPLICE SHALL BE EMBEDMENT
SHALL BE REPORTED TO ENGINEER FOR CLARIFICATION. LOCATED WITHIN THE JOINTS OR WITHIN A DISTANCE EQUAL TO TWICE THE MEMBER DEPTH Ld HOOK H SPLICE 1.3XLd 1.7XLd 1.4XLd 1.4XLd 1.82XLd 2.4XLd
FROM THE FACE OF THE JOINT.
WELL DETAILED AND COMPLETE SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF E = 25
Ø 10 250 300 400 500 350 350 450 600
ALL STRUCTURAL MEMBERS SHALL BE SUBMITTED TO THE ENGINEER FOR HIS REVIEW AND PROVIDE LAP SPLICES IN GIRDERS WITH HOOPS OR STIRRUPS OVER THE ENTIRE LENGTH OF THE H = 150
APPROVAL BEFORE FABRICATION. SPLICE SPACED NO FARTHER THAN 1/4 THE NOMINAL DEPTH OR 100mm.
E = 150
Ø 12 300 400 500 600 400 400 600 700
CONTRACTOR SHALL PROVIDE DETAILED AND COMPLETE SHOP DRAWINGS OF SLAB, BEAM (TIE WELDED SPLICES AND MECHANICAL CONNECTIONS MAY BE USED AT ANY SECTION PROVIDED NOT H = 200
BEAMS, FLOOR BEAMS, ROOF BEAMS), COLUMNS, AND FOOTING REINFORCEMENTS AT EVERY MORE THAN ALTERNATE LONGITUDIANAL BARS ARE SPLICED AT ANY SECTION AND DISTANCE E = 200
FRAME ELEVATION AND PLAN SHOWING THE FOLLOWING : LOCATION OF SPLICES / CUT-OFF BETWEEN SPLICES MUST BE 600mm OR MORE ALONG THE AXIS OF THE COLUMNS. Ø 16 400 500 600 700 600 600 700 900
POINTS OF LONGITUDINAL BARS, LOCATION AND SPACING OF LONGITUDINAL BARS, PLACEMENT H = 250
AND DIRECTON OF HOOKS AND OTHER EMBEDMENTS, LOCATION OF SPECIAL TIES AT E = 250
BEAM-COLUMN JOINTS. FABRICATION AND INSTALLATION OF REINFORCING BARS SHALL NOT BE Ø 20 500 600 700 900 700 700 900 1200
ALLOWED WITHOUT THE ABOVE SHOP DRAWING REQUIREMENTS AND APPROVAL OF THE 6.0 CAMBER AND REINFORCEMENT SPACING H = 300
ENGINEER. E = 300
Ø 25 800 800 1000 1400 1100 1100 1500 1900
UNLESS OTHERWISE NOTED ON PLANS OR SPECIFICATIONS, CAMBER ALL BEAMS AND GIRDERS H = 400
THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECT, ELECTRICAL, MECHANICAL ATLEAST 6mm FOR EVERY 4500mm OF SPAN EXCEPT FOR CANTILEVERS FOR WHICH THE CAMBERS
SANITARY AND OTHER UTILITY AND EQUIPMENT PLANS FOR THE EXACT SIZE, NUMBER, AND SHOULD BE AS NOTED ON THE PLANS OR AS ORDERED BY THE DESIGNER.
LOCATION OF ALL SLEEVES OR OPENINGS THRU FLOORS, SLABS, BEAMS AND WALLS. STRAIGHT STRAIGHT
IF THERE ARE TWO OR MORE LAYERS OF REINFORCING BARS IN A BEAM OR GIRDER, USE
IT SHALL BE THE CONSTRACTORS RESPONSIBITLITY TO PROVIDE ADEQUATE TEMPORARY SEPARATORS OF SIZE NOT LESS THAN 25mm BARS SPACED AT ABOUT 900mm ON CENTER AND IN EMBEDMNT EMBEDMNT
SHORING AND BRACING OF THE STRUCTURE FOR ALL LOADS THAT WILL BE IMPOSED UPON IT NO CASE SHALL THERE BE LESS THAN TWO SEPARATORS BETWEEN LAYRES OF BARS.
DURING CONSTRUCTION. CLASS B CLASS C CLASS A CLASS B CLASS C

SKETCH

CLASS A
E
2.0 FOUNDATION BEAM REINFORCING BARS BOTH TOP AND BOTTOM TERMINATING IN A WALL SHALL EXTEND AT

MINIMUM
THE MOST 50mm FROM THE FAR FACE OF THE WALL AND SHALL TERMINATE IN A STANDARD 90

CONC.
FOUNDATION DESIGN WAS BASED ON THE RECOMMEDATIONS CONTAINED IN THE GEOTECHNICAL DEG. HOOK.

300
INVESTIGATION REPORT OF THIS PROPOSED STRUCTURE.
LONGITUDINAL REINFORCEMENT OF GIRDERS, BOTH TOP AND BOTTOM TERMINATING IN A H
THE CONTRACTOR SHALL REPORT IN WRITING TO THE DESIGNER ON THE ACTUAL CONDITION OF COLUMN SHALL EXTEND TO THE FAR FACE OF THE CONFINED CONCRETE CORE OF THE COLUMN
THE SOIL UNCOVERED AND CONFIRM THE ACTUAL BEARING CAPACITY BEFORE DEPOSITING AND SHALL TERMINATE AT A 90 DEG. HOOK.
CONCRETE.
END END FOR COLUMN BEAM BOTTOM FOR CONC. FOR BEAMS BEAM TOP BEAM BOTTOM FOR CONC.
NO FOOTINGS SHALL REST ON FILL, CHB FOOTINGS AND OTHER MINOR STRUCTURE SHALL BE ANCHORAGE ANCHORAGE VERTICAL BARS WHERE WALL INTO WALLS BARS WHERE BARS WHERE WALL HOR.
EMBEDDED TO ATLEAST 600mm FROM THE NATURAL GRADE LINE. 7.0 STRUCTURAL STEEL FOR BOTTOM FOR BOTTOM BARS, BEAM TENSILE VERTICAL TENSILE TENSILE BARS, BEAM
BARS OF BARS OF BOTTOM BARS STRESS IN BARS, SLAB & STRESS IN STRESS IN TOP BARS
PROVIDE TEMPORARY REMOVAL OF WATER FROM ANY SOURCE DURING CONSTRUCTION.

REMARKS
SLABS AND SLABS, BEAMS, WHERE BARS <0.5fy & BEAM BARS BARS <0.5fy & BARS <0.5fy & WHERE
DEWATERING SHALL BE CAREFULLY DONE TO AVOID DISTURBING THE FOUNDATION AND SLAB ALL MATERIAL AND WORKMANSHIP SHALL CONFORM TO THE 9TH EDITION OF THE AMERICAN
BEARING SURFACES. BEAMS WALLS, TENSILE % OF BAR TENSILE % OF BAR % OF BAR STRESS IN
INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL UNLESS OTHERWISE SHOWN OR NOTED COLUMN STRESS IN SPLICE X 75% STRESS IN SPLICE <75% SPLICE <75% BARS >0.5fy &
THE CONTRACTOR SHALL DESIGN, INSTALL AND MONITOR ALL EXCAVATION RETENTION SYSTEM DOWELS TO BAR < 0.5fy & % BARS >0.5fy & % OF BAR
STRUCTURAL STEEL YEILD STRENGHT (fy)
AS REQUIRED FOR PROTECTION OF ADJACENT PROPERTIES AND PROVIDE ALL MEASURES AND FOOTING OF BAR % OF BAR SPLICE <75%
PRECAUTIONS NECESSARY TO MINIMIZED SETTLEMENT AND PREVENT DAMAGE TO EXISTING OR
HOT ROLLED STEEL 248 mpa (36000 psi) SPLICE >75% SPLICE >75%
NEW CONSTRUCTION.
COLD ROLLED STEEL 228 mpa (30000 psi)
ALL STRUCTURAL FILL MATERIALS SHALL BE COMPACTED TO 95% IN ACCORDANCE WITH THE
THE CONTRACTOR SHALL FURNISHED ALL PLATES, CLIP ANGLES, CONNECTORS, ETC. REQUIRED
ASTM D698. FILLS SHOULD BE PLACED IN LIFTS NOT TO EXCEED 300mm.
FOR THE COMPLETION OF THE STRUCTURE EVEN IF SWUCH ITEM IS NOT SHOWN IN THE
CONTRACT DRAWING.
SEE ALL OTHER PLANS FOR SUBSOIL DRAINAGE SYSTEM, MACHINERY ANCHORS AND OTHER
EMBEDMENTS, DEPRESSIONS, FINISHES AND DOWELS OF MASONRY'S.
WELDING SHALL BE IN ACCORDANCE WITH THE AMERICAN WELDING SOCIETY CODE, AWS D1.1
UNLESS INDICATED OTHERWISE, WELDING ELECTRODES SHALL BE E60XX.

3.0 CONCRETE AL BOLTS AND THREADED FASTENERS SHALL BE ASTM A 307 UNLESS OTHERWISE SPECIFIED.

CONCRETE MINIMUM ULTIMATE COMPRESSIVE STRENGTH AT 28 DAYS SHALL BE :


f'c = 20.70 mpa (3,000 psi) (See Footnote for Each Member)
8.0 MASONRY MINIMUM EMBEDMENT LENGTHS TO PROVIDE 50 mm COVER
f'c = 20.70 mpa (2.500 psi) (See Footnote for Each Member)
f'c = 13.8 mpa(2000 psi) LEAN CONCRETE AND OTHER NON STRUCTURAL ELEMENTS TO TAIL OF STANDARD END HOOK
ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE APPLICABLE
AGGREGATE SIZES WILL BE AS FOLLOWS : STANDARDS AND SPECIFICATION OF THE NATIONAL CONCRETE MASONRY ASSOCIATION AND THE
BAR SIZE 10 12 16 20 25 28 32 36
NATIONAL BUILDING CODE.
20 mm MAX. FOR SUSPENDED SLABS, BEAMS, COLUMNS, RC WALLS
25 mm MAX. FOR FOUNDATION, THICKENED SLABS, SLABS ON GRADE CONRETE MASONRY UNITS SHALL CONFORM TO ASTM C 90 GRADE N. EMBEDMENT Ld 150 175 175 200 250 300 350 375
MINIMUM CONCRETE COVERS OF BARS SHALL NOT BE LESS THAN THE FOLLOWING:
MORTAR GROUT FOR ALL REINFORCED MASONRY SHALL CONFORM TO ASTM STANDARD 270 TYPE
70 mm UNFORMED CONCRETE DEPOSITED AGAINST GROUND M AND SHALL HAVE A MINIMUM 28 DAY STRENGHT OF 21 mpa.
70 mm FORMED CONCRETE EXPOSED TO GROUND OR WEATHER
30 mm COLUMNS AND BEAMS NOT EXPOSED TO GROUND OR WEATHER ALL MASONRY WALLS SHALL BE REINFORCED IN ACCORDANCE WITH THE STANDARD SCHEDULE
20 mm SLABS AND WALLS NOT EXPOSED TO GROUND OR WEATHER OF CONCRETE HOLLOW BLOCK REINFORCEMENT UNLESS OTHERWISE INDICATED IN THE PLANS. EMBEDMENT LENGTH EMBEDMENT LENGTH
Ld Ld
ALL REINFORCING STEEL DOWELS, ANCHOR BOLTS AND OTHER INSERTS SHALL BE SECURED IN
POSITION PRIOR TO POURING OF CONCRETE.

CONCRETE CYLINDER SPECIMENS SHALL BE TAKEN FOR EACH DAY POUR AND EACH 50cu.m OR A REINFORCEMENTS OF MASONRY UNITS

db

db
FRACTION THEREOF CAST IN ACCORDANCE WITH ASTM C31 AND TESTED IN ACCORDANCE WITH
ASTM C39. REINFORCEMENT
THICKNESS NOTES
90 deg.
HORIZONTAL VERTICAL

D
4.0 REINFORCING BARS
100 Ø 10 @ 600 O.C. Ø 10 @ 600 O.C. MIN. LAP SPLICE = 200
REINFORCING STEEL GRADE :

12db
125 Ø 10 @ 600 O.C. Ø 10 @ 600 O.C. PROVIDE RIGHT ANGLED
ASTM A615 GRADE 75 (fy = 517 mpa) (Not Applicable) REINFORCED 900 mm LONG
ASTM A615 GRADE 60 (fy = 414 mpa) DEFORMED BARS Ø16 AND ABOVE 50 mm MIN.
Ø 12 @ 600 O.C. Ø 12 @ 600 O.C. 4d
ASTM A615 GRADE 40 (fy = 275 mpa) DEFORMED BARS Ø10 AND Ø12. 150
65mm MIN.
ALL REBARS SHALL BE BENT COLD UNLESS PERMIRRED BY THE STRUCTURAL ENGINEER. 200 Ø 12 @ 600 O.C. Ø 12 @ 600 O.C.
ALL REBARS SHALL BE CLEANED PRIOR TO PLACING OF CONCRETE.

IF WELDING IS NOT AVOIDED IN SPLICES, A FULLY WELDED SHALL HAVE BARS BUTTED AND
WELDED TO DEVELOP TENSION OF ATLEAST 125% OF THE SPECIFIED YIELD STRENGHT OF THE
REBAR.

ALL WELDING OF REBARS SHALL CONFORM TO THE PROVISIONS OF THE STRUCTURAL WELDING
CODE REQUIREMENTS FOR REINFORCING STEEL, AWS D1.4 1.
SPECIFICATIONS (Brief)
Use Grade 60 for Steel Fy=413.70Mpa for 16Ø and Above
STANDARD END HOOK DETAILS
2. Use Grade 40 for Steel Fy=275.8Mpa for 12Ø and Below
3. Use Fc' =3,000psi for All Concrete, Except Slab on Fill 2,500psi
4. Use 5"Chb Ordinary Ground Floor to Second Floor, Except at Griline 2 (External Wall 4"Chb)
5. Use 4"Chb Ordinary Second Floor to Roof, Except at Gridline 2 (Internal Wall 5"Chb)

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

PROPOSED TWO STOREY 60 SQM.


PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL
GENERAL CONSTRUCTION NOTES
MIN.EMBEDMENT & LAP SPLICES
STANDARD END HOOK DETAILS
REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
S
DUPLEX HOUSING UNIT JOAN KRYSTAL T. PUBLICO ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER DATE:
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER, 01
LOCATION:
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE
GENERAL MANAGER
REG. NO.
LIC. NO.
109017
2601671
DATE
DATE
01-08-08
11-20-20
DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
08
Detail of Column
Top CTB to
COLUMN Footing to Top CTB Roof Beam
TOP OF BEAM / SLAB
AT HIGHEST FLOOR LEVEL
70 70 30 30

70
C1

30
200X450

400
530
(1-Set)

50

Hn/4
SPECIAL TIES 10 mm

30
70
dia. AT 100
280 200
Concrete Cover 70mm Concrete Cover 30mm
STANDARD HOOK DETAILS
DISTRIBUTION OF 12mm dia. TIES

Rebars
CLASS B
6pcs-16mm 6pcs-16mm

SPLICE

SUCCEEDING FLOOR LEVELS

A
DIMENSION OF STD. DIMENSION OF STD. DIMENSION OF STD.
70 70 30 30 BAR 180 DEG. HOOK 90 DEG. HOOK 135 DEG. HOOK
135 deg.
SIZES ALL GRADES (mm) ALL GRADES (mm) ALL GRADES (mm)
C2

Hn/2

70

30
Hn
A D J A D A H D
200X400

H
480

400
SPECIAL TIES 10 mm Ø 10 125 55 75 150 55 125 90 38
(5-Sets)

DETAILING DIMENSION
dia. AT 100
Ø 12 150 75 100 200 75 165 115 50

30
70
Ø 16 175 95 125 250 95 200 140 65 D
COLUMN VERTICAL 280 200
BARS Ø 20 200 115 150 300 115 275 165 115
Concrete Cover 70mm Concrete Cover 30mm
db

Hn/4
Ø 25 275 150 200 400 150 365 225 150
Rebars 6pcs-16mm 6pcs-16mm
Ø 28 375 240 300 475 240
50

70 70 30 30
Ø 32 425 265 335 550 265
C3

70

30
Ø 36 475 300 370 600 300
200X400 12Ø 12Ø

480

400
(3-Sets)

C BEAM
50

30
70
280 200
SPECIAL TIES 10 mm
dia. AT 100 Concrete Cover 70mm Concrete Cover 30mm
Rebars 4pcs-16mm & 2pcs-12mm 4pcs-16mm & 2pcs-12mm

70 70
30 30
C4

70

30
DISTRIBUTION OF 10 mm dia. TIES

150X400

330

250
(2-Sets)
DETAILING DETAILING A DETAILING HOOK A
DIMENSION DIMENSION DIMENSION
CLASS B
SPLICE

30

db
70

db

db
205 125
90 deg. 135 deg.
Concrete Cover 70mm Concrete Cover 30mm

D
J
D
Rebars

A
4pcs-12mm 4pcs-12mm

12db

db
10
COLUMN VERTICAL SPECIAL TIES 10 mm
BARS dia. AT 100 Ties 10Ø: 2-@100, 4-@150, Rest-@200 4d
65mm MIN.
H

90 deg. 135 deg. 180 deg.


db = NOMINAL DIAMETER OF BAR TO BEND

Detail of Footing D = FINISHED BEND DIAMETER

FOOTING LENGTH WIDTH THICKNESS


(L mm) (W mm) (t mm)
REBARS STANDARD HOOK DETAILS
F1 1600 1600 250 6pcs-16mm dia. B.W.

F2 1500 1500 250 5pcs-16mm dia. B.W.

F3 1300 1300 225 4pcs-16mm dia. B.W.

F4 1200 1200 200 4pcs-16mm dia. B.W.

COLUMN SPLICE & SPECIAL TIES F5 1100 1100 200 4pcs-16mm dia. B.W.

F6 600 600 150 4pcs-12mm dia. B.W.

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
S
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL


COLUMN SPLICE & SPECIAL TIES / COLUMN REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. DETAIL / FOOTING DETAIL / STANDARD
HOOK DETAILS /

02
DUPLEX HOUSING UNIT JOAN KRYSTAL T. PUBLICO
DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER

08
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER DATE 01-08-08
REG. NO. 109017 DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 2601671 DATE 11-20-20
1 2 3
SECOND FLOOR BEAMS: REINFORCING BARS SECOND FLOOR BEAMS: REINFORCING BARS

1 2 3 C B A
5pcs-16Ø 5pcs-16Ø
BEAM Support Midspan Support Midspan Support BEAM Support Midspan Support Midspan Support

2B1 2B1a 2B1a 2B1 200 200 200 200 200 200
30 30 200 200 200 200 30 30 30 30 30 30 30 30 30 30

20 Clear
30

30

30

30

30

30
5-16Ø 5-16Ø 5-16Ø 5-16Ø 5-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø

400

400

400

400

400

400

400

400

400
200X400

485
200X485 200X485 200X400 3-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø 2-16Ø 2-16Ø 2-16Ø 2-16Ø 2-16Ø

30

30

30

30

30

30
2-16Ø
3pcs-16Ø 3pcs-16Ø
2pcs-16Ø (See Detail) 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø
3525 975 975 3525 2B4
5pcs-16Ø 5pcs-16Ø 5pcs-16Ø 5pcs-16Ø 5pcs-16Ø 2pcs-16Ø 2pcs-16Ø
2B1-2B1a 200X400 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
3pcs-16Ø 3pcs-16Ø
200X400/485 3pcs-16Ø 5pcs-16Ø 3pcs-16Ø
3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø
2B5
5pcs-16Ø 5pcs-16Ø 5pcs-16Ø 5pcs-16Ø 5pcs-16Ø 2pcs-16Ø 2pcs-16Ø
DETAIL BEAM 2B1-2B1a 2B2
3pcs-16Ø 3pcs-16Ø
200X400 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø

200X400 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø

200 200 200 200 200 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø
2B6
1
30 30 30 30 30 30 30 30 30 30

2pcs-16Ø 2pcs-16Ø
200X400 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø

30

30

30

30

30
3-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø

400

400

400

400

400
Temperature Bars: 2-16Ø 2-16Ø 2-16Ø 2-16Ø 2-16Ø
10Ø-@300mm O.C.

30

30

30

30

30
3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø 3pcs-16Ø
2B3
2pcs-16Ø 2pcs-16Ø
10Ø-@180mm O.C. 200X400 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø

Stirrups 10Ø: 2-@100, 5-@150, 5-@200, Rest-@250

765 765 975


Stirrups 10Ø: 2-@100, 5-@150, 5-@200, Rest-@250

100
10Ø-@180mm O.C.
2B4 2B5
500

ROOF BEAMS: RSB


Detail of S-1 & Cantilever Slab ROOF BEAMS: RSB
C B A
1 2 3
BEAM Support Midspan Support Midspan Support
COLUMN-TIE-BEAMS (CTB): RSB BEAM Support Midspan Support Midspan Support
150

150
2-16Ø

1 2 3
2-16Ø

300
2-16Ø

300
COLUMN-TIE-BEAMS (CTB): RSB 2-16Ø
2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø RB2
BEAM Support Midspan Support Midspan Support 2pcs-16Ø 2pcs-16Ø
RB1 150X300 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
2pcs-16Ø 2pcs-16Ø
150X300 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
C B A
150
200
2-12Ø
Stirrups 10Ø: 2-@100, 5-@150, 5-@200, Rest-@250
300

2-16Ø
2-12Ø

300
2-16Ø
For All (CTB) 2pcs-12Ø 2pcs-12Ø 2pcs-12Ø 2pcs-12Ø 2pcs-12Ø
BEAM Support Midspan Support Midspan Support
2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
150X300 2pcs-12Ø 2pcs-12Ø 150
RB3
2pcs-12Ø 2pcs-12Ø 2pcs-12Ø 2pcs-16Ø 2pcs-16Ø
2-12Ø 200X300 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
300

2-12Ø
Stirrups 10Ø: 2-@100, Rest-@200
For All (CTB) 2pcs-12Ø 2pcs-12Ø 2pcs-12Ø 2pcs-12Ø 2pcs-12Ø
150X300 2pcs-12Ø 2pcs-12Ø
2pcs-12Ø 2pcs-12Ø 2pcs-12Ø

2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø


(CTB) Along Grid 2 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø 2pcs-16Ø
150X300 Stirrups 10Ø: 2-@100, 5-@150, 5-@200, Rest-@250

Stirrups 10Ø: 2-@100, Rest-@200

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
S
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
BEAM DETAIL \ RC BARS SCHEDULE
PROPOSED TWO STOREY 60 SQM. CANTILEVER SLAB DETAIL

03
DUPLEX HOUSING UNIT JOAN KRYSTAL T. PUBLICO
DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER

08
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER DATE 01-08-08
REG. NO. 109017 DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 2601671 DATE 11-20-20
Top Bars @
Top Bars @ Top Bars @
Discontinous End Continous Support Continous Support

t (mm)
L1/4 L1/4 L2/4 L2/4 L3/4

Mid-span Mid-span Mid-span

Bottom Bars Bottom Bars Bottom Bars

Bottom Bars
L1/6 L1/6 L2/6 L2/6 L3/6

Span L1 Span L2 Span L3

Typical Detail of One-Way /Two-Way Slab

0.30L1 0.30L1 0.30L2 0.30L2 0.30L3

Detail Reinforcement of One-Way / Two-Way Slab


SLAB REINFORCEMENT
SLAB
L1/5 L1/5 L2/5 L2/5 L3/5 SLAB BAR SHORT SPAN LONG SPAN
DESIGNATION THICKNESS
MARK LOCATION DISCONTINOUS CONTINOUS DISCONTINOUS CONTINOUS
(mm) BAR DIA.
SUPPORT
MIDSPAN
SUPPORT
BAR DIA.
SUPPORT
MIDSPAN
SUPPORT
(mm) O.C. (mm) (mm) O.C. (mm)
O.C. (mm) O.C. (mm) O.C. (mm) O.C. (mm)
TOP 10 180 180 10 300 300
(S-1) ONE-WAY SLAB 100
180 300 300 300
Span L1 Span L2 Span L3 BOTTOM 10 180 180 10
100 TOP 10 180 180 12 180 180
(S-2) TWO-WAY SLAB
180 180 180 180
BOTTOM 10 180 180 12

Typical Detail of Continuos Beams


Extra Rebars (Cut-Off)
(Stirrups Not Shown)

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
S
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. TYPICAL DETAIL OF CONTINUOS BEAM
TYPICAL DETAIL OF SLABS

04
DUPLEX HOUSING UNIT JOAN KRYSTAL T. PUBLICO
DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER

08
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER DATE 01-08-08
REG. NO. 109017 DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 2601671 DATE 11-20-20
1 2 3 1 2 3 1 2 3
16000 16000 16000
8000 8000 8000 8000 8000 8000
3000 5000 5000 3000 3000 5000 5000 3000 3000 5000 5000 3000
2950 2050 2050 2950 2950 2050 2050 2950 2950 2050 2050 2950

PROPERTY LINE PROPERTY LINE PROPERTY LINE


C4
F6 Shelf Shelf Shelf Shelf
2000

2000

2000

2000

2000

2000
150X350

PROPERTY LINE

PROPERTY LINE

PROPERTY LINE
CTB
A A A
C3 150X300 C3 150X300 C3 200X400 200X400 200X400 200X400 150X300 150X300

RB1 RB1 RB1 RB1


F5 CTB CTB
F5
2B3 2B3
2150
2B3 2B3
F3
2750

200X400

200X400

200X400

200X400

200X400
150X300
150X300

150X300

150X300

150X300
200X300
150X300

150X300
5" Chb 5" Chb

2050

2050

2050
2B5
CTB

CTB

CTB
2100

2100

2100
2B4

2B4

RB2

RB2

RB3

RB2

RB2
WF1

WF1
(S-2) (S-2) (S-2) (S-2)

C-Purlins 2"X5"X1.60mm Thk.

C-Purlins 2"X5"X1.60mm Thk.


1900
2950

2950

2950

2950

2950

2950
2B6

2B5
F1 C1
B B B
150X300 150X300 200X400 200X400 200X400 200X400 150X300 150X300 150X300 150X300
C2 C2

(Galvanize)

(Galvanize)
CTB 5" Chb 5" Chb CTB 2B2 2B2 2B2 2B2 RB1 RB1 RB1 RB1
F3 F3

WF1

WF1
10000

10000

10000

10000

10000

10000
6000

6000

6000

6000

6000

6000
CANTILEVER SLAB

CANTILEVER SLAB
WF1 WF1

200X400

200X400
200X400

200X400

200X400

200X300
150X300

150X300

150X300

WELL

WELL

150X300

150X300

150X300

150X300
2B5

2B5
2B6
2B4

2B4

RB2

RB2

RB3

RB2

RB2
3950

3950

3950
(S-1) (S-1)
3900

3900

3900
Stair Stair
CTB

CTB

CTB
Footing Footing

STAIR

STAIR
3050

3050

3050

3050

3050

3050
Stair Stair
Column Column
Slab Rebars: 10Ø-@400mm O.C.

C2 2B1 2B1a 2B1a 2B1


PROPERTY LINE

PROPERTY LINE

PROPERTY LINE
C C
CTB CTB RB1 RB1 RB1 RB1

F4 C2 150X300
F2
150X300
F4 C2 C 200X400 200X485 200X485 200X400 150X300 150X300

150X350
2000

2000

2000

2000

2000
CTB

C-Purlins 2"X5"X1.60mm Thk.


Shelf Shelf Shelf Shelf
600mm O.C. (Galvanize)
C4
F6 PROPERTY LINE PROPERTY LINE PROPERTY LINE
Note: Provide 12Ø Sag Rod at Midpoint

3000 2850 2150 3000 3000 2850 2150 3000 3000 2850 2150 3000
8000 8000 8000
16000 16000 16000

B 2F FLOOR FRAMING LAYOUT C ROOF FRAMING PLAN


S 05 SCALE 1:100 S 05 SCALE 1:100

A B Rib Type 0.40mm Thk. C


100
10Ø-@150mm O.C. A B Rib Type 0.40mm Thk. C
100
2pcs-12Ø 10Ø-@150mm O.C.

150
C-Purlins 125X50X1.60mm Thk. C-Purlins 125X50X1.60mm Thk.
125mm Chb Parapet Wall 600mm O.C. (Galvanize)

150
600mm O.C. (Galvanize) 2pcs-12Ø
599 Lintel Beam
600 Cleats: 12Ø Round Bar 600 Lintel Beam
600
600
1
600 Shelf: 2pcs-2"X2"X 4" Angle Bar
600 600 (Embedded to Concrete)
600 600
1800

600 600 600


600
975

600
412 399
399
412 395 4" Chb
401

Lintel Beam 100X150 1 Lintel Beam 100X150 1


1 Shelf: 2pcs-2"X2"X 4" Angle Bar
Shelf Shelf 2"X2"X 4" Angle Bar Shelf: 2pcs-2"X2"X 4" Angle Bar
(Provide Expansion Bolts) (Embedded to Concrete) (Embedded to Concrete)

5" Chb 5" Chb 5" Chb 5" Chb


2500

12Ø Round Bar


Welded to Angle Bars
2700

5" Chb 5" Chb 5" Chb 5" Chb 5" Chb 5" Chb
F6C4

F6C4
1200

200
200

GROUND FLOOR LINE N.G.L. GROUND FLOOR LINE N.G.L.


(+00.20 mts.) (+00.20 mts.)
1200

D FRAME ALONG GRID LINE 2 E FRAME ALONG GRID LINE 1 & 3


S 05 SCALE 1:100 M S 05 SCALE 1:50

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
S
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL FOUNDATION PLAN REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. 2F FLOOR FRAMING PLAN
ROOF FRAMING PLAN /DETAILED SECTION

05
DUPLEX HOUSING UNIT JOAN KRYSTAL T. PUBLICO
DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER

08
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER DATE 01-08-08
REG. NO. 109017 DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 2601671 DATE 11-20-20
125 100

125mm THK CHB 100mm THK CHB WALL @


FIREWALL, FRONT, REAR, INTERIOR/CR

10mm Ø HORIZONTAL RSB 10mm Ø HORIZONTAL RSB


@ EVERY 3RD CHB LAYER @ EVERY 3RD CHB LAYER

10mm Ø VERTICAL RSB 10mm Ø VERTICAL RSB 2-16mm Ø TOP BAR


@ 600mm O.C. @ 600mm O.C.

100mm THK CONCRETE 100mm THK CONCRETE


200 SLAB WITH 10mm Ø TEMP. SLAB WITH 10mm Ø TEMP.
BARS @ 400mm BOTHWAYS BARS @ 400mm BOTHWAYS

OVERLAP
400
100

100
ROOF VENTILATION
400
OVERLAP
(SEE DETAIL)

100

100
2-16mm Ø TOP BAR
L/4

2-16mm Ø TOP BAR

OVERLAP
10mm Ø STIRRUPS

400
1 @ 50mm, 4 @ 100mm,
10mm Ø STIRRUPS REST @ 200mm O.C., BEND
REINFORCED
1 @ 50mm, 4 @ 100mm, 135° HOOK, 6db 75mm MIN.,
CONC. COLUMN
REST @ 200mm O.C., BEND ROTATED (TYP.)
NGL NGL
135° HOOK, 6db 75mm MIN.,
ROTATED (TYP.)
100 THK GRAVEL 100 THK GRAVEL 4-16mm Ø VERTICAL BARS
BEDDING BEDDING 10mm Ø STIRRUPS
1 @ 50mm, 4 @100mm,
COMPACTED SOIL COMPACTED SOIL
REST @ 200mm O.C., BEND
400

400
135° HOOK, 6db 75mm MIN.,
ROTATED (TYP.) SECTION
PLAN
TYPICAL BEAM TO COLUMN
625

625
3-10mm Ø RSB WITH 2-12mm Ø RSB WITH
3 CONNECTION
10mm Ø RSB LATERAL 10mm Ø RSB LATERAL S 06 SCALE 1:10
225

225
TIES @ 250mm O.C. TIES @ 300mm O.C.
75

75
100 THK GRAVEL 100 THK GRAVEL
BEDDING BEDDING

COMPACTED SOIL COMPACTED SOIL

65db 75 MM MIN. AT LEAST Ldh


.0° .0°
400 300 135 135

90°

12db
db

WF-1 A WALL FOOTING DETAIL WF-2 I.D.= 4db FOR


S 06 SCALE 1:10 10, 12, 16 MM Ø
db
65db 75 MM MIN.
4db OR 65 MM MIN.

4db FOR 10 MM TO 25 MM

C DETAILS OF STANDARD HOOK 5db FOR 28 MM TO 32 MM


6db FOR 36 MM

S 07 SCALE 1:5
Ldh = BASIC DEVELOPMENT
LENGTH OF STANDARD
HOOKS IN TENSION

50 100 100 50
10mm Ø REINFORCEMENT
BAR DOWELS FOR CONNECTING
WALL FOOTING TO COLUMN
REINFORCEMENT
NGL
2 % SLOPE
10mm Ø RSB

WF-2 12mm x 12mm


DRIP MOLD

100
400
REINFORCED CONCRETE
LEDGE, SMOOTH OFF-FORM FINISH
600

OVERLAP

625
10mm Ø RSB@
400
200mm O. C.
400

75
OVERLAP
50mm x 100mm WOOD 10mm THK CHB WALL
825

DOOR JAMB

REINFORCED
225

50 CONCRETE BEAM
(B1)

300
75
225

10mm Ø RSB LATERAL


TIES SPACED @ 300mm
O.C.
EXTERIOR SIDE INTERIOR SIDE DOOR
76

2-12mm Ø RSB
(REFER TO SCHED.)
LONGITUDINAL BARS
10mm DOUBLE REINFORCEMENT
RSB

1000

TYPICAL WALL FOOTING TO


CONCRETE LEDGE DETAIL DOOR JAMB DETAIL
B COLUMN CONNECTION D
S 06 SCALE 1:5 E
S 06 SCALE 1:10 S 06 SCALE 1:5

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
S
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL WALL FOOTING DETAILS/TYP. WALL FOOTING TO REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. COLUMN CONNECTION/TYP. BEAM TO COL.
CONNECTION/SCHED OF BEAMS/CONC LEDGE

06
DUPLEX HOUSING UNIT
DETAIL/DOOR JAMB DETAIL
JOAN KRYSTAL T. PUBLICO ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER DATE:

08
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER DATE 01-08-08
REG. NO. 109017 DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 2601671 DATE 11-20-20
10mm Ø DOUBLE VERTICAL
10mm Ø DOUBLE VERTICAL CONCRETE SILL FOR REINFORCEMENT @ SIDES
REINFORCEMENT @ SIDES WINDOW(SEE DETAIL) OF OPENING
OF OPENING

A B
10mm Ø DOUBLE VERTICAL
REINFORCEMENT BARS @
600mm O.C.

20mm SEISMIC GAP

LAP SPLICE LENGTH


TOP OF FIREWALL 10mm Ø DOUBLE VERTICAL
(+07.20mts.) REINFORCEMENT BARS @
600mm O.C.

400
CEMENT PLASTER, EACH SIDE OF WALL
16mm MIN.

10mm Ø HORIZONTAL REINFORCEMENT


BARS @ EVERY 3RD LAYER OF CHB
1800

DETAILED PLAN OF VERTICAL


2ND FLR. CL.
(+05.40 mts.)
C REINFORCEMENT AT SIDES OF OPENINGS
S 07 SCALE 1:10

200
10mm THK CHB WALL 10mm THK CHB WALL

686
20mm SEISMIC GAP TOP OF ROOF BEAM

BOTTOM OF ROOF BEAM


WINDOW (RFER TO WIN. SCHED.) MORTAR
2500

OPENING OPENING

686
D PLAN OF WINDOW OPENING
7200

S 07 SCALE 1:10 M
457

686
10mm VERTICAL
REINFORCEMENT
BARS @ 600mm O.C. REINFORCED
2ND FLR. CL.
(+02.90 mts.) CONC. BEAM

200
TOP OF OPENING

90° HOOK FOR VERTICAL


REINFORCEMENT BARS
20mm SEISMIC GAP
CONNECTING TO LOFT

686
BEAM
EXTERIOR SIDE
ALUMINUM FRAME
OPENING
TOP OF BEAM
5
2700

OPENING S-4
CHB WALL IN BOTTOM OF BEAM
20mm SEISMIC GAP
RUNNING BOND

686
BEAM
REINFORCEMENT
10mm HORIZONTAL
REINFORCEMENT

SECTION DETAIL
STANDARD LENGTH OF
BARS @ EVERY 3
LAP SPLICES FOR REINFORCEMENT

SCHEDULE OF WINDOW
LAYERS OF CHB
BARS

E ABOVE OPENING

686

REFER TO
GROUND FLOOR LINE
S 07 SCALE 1:10
457
(+00.20 mts.)
200

FIN. GROUND LINE CONCRETE SILL


(+00.00 mts.) FOR WINDOWS
457

(SEE DETAIL) ALUMINUM FRAME

6
10mm HORIZONTAL
RSB @ EVERY 3RD CONCRETE SILL
10mm VERTICAL LAYER OF CHB FOR WINDOW
REINFORCEMENT
S-4 OPENINGS
BARS @ 600mm O.C. CHB WALL

75 25
FIN. FLOOR LINE

100
2-10mm Ø DOUBLE
HORIZONTAL REINF.
600 600 600 600 600 600 600 N.G.L. STEEL BAR

CHB WALL

CEMENT PLASTER, EACH SIDE

SECTION DETAIL OF TYPICAL WALL TOP OF WALL FOOTING


WALL FOOTING OF THE WALL (16mm MIN.)

A AND OPENING REINFORCEMENT


S 07 SCALE 1:30 SECTION DETAIL OF
B WALL AND OPENING SECTION CONCRETE SILL BELOW
S 07 SCALE 1:30 F WINDOW OPENING
S 07 SCALE 1:10

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
S
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL SECTION DETAIL OF TYPICAL WALL & OPENING REINF./ REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
DET. PLAN OF VERT. REINF. AT SIDE OF OPENINGS/ WALL
PROPOSED TWO STOREY 60 SQM. & OPENING SEC./PLAN OF WINDOW OPENING/SEC. DETAIL ABOVE
OPENING/SEC. DET. CONC. SILL BELOW WINDOW OPENING

07
DUPLEX HOUSING UNIT JOAN KRYSTAL T. PUBLICO
DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER

08
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER DATE 01-08-08
REG. NO. 109017 DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 2601671 DATE 11-20-20
400 400

0.40 mm THK
PRE-PAINTED G.I. FLASHING
0.40 mm THK
0.40mm THK PRE-FINISHED 0.40mm THK PRE-FINISHED PRE-PAINTED G.I. FLASHING
RIB TYPE G.I. SHEET ROOFING RIB TYPE G.I. SHEET ROOFING 6mm Ø J-BOLT @ TOP AND
BOTTOM PURLINS; 5mm Ø TEK
6mm Ø J-BOLT @ TOP
SCREW @ THE REST OF THE PURLINS
AND BOTTOM PURLINS; 125mm x 50mm x 1.60mm
5mm Ø TEK SCREW @ 300 300
THK LIP CHANNEL PURLINS @ 600mm
THE REST OF THE PURLINS WITH 12mm SAGROD @ MIDSPAN
125mm x 50mm x 1.60mm
THK LIP CHANNEL PURLINS
@ 600mm O.C. WITH 12mm
SAGROD @ MIDSPAN FIREWALL
25

300
TOP OF ROOF BEAM
25

0.40mm THK
PRE-PAINTED G.I.
SHEET FLASHING
200
300

LINE OF INCLINED
BEAM 0.40mm THK
PRE-PAINTED RIB
TYPE G.I. SHEET
150 400 REINFORCED CONCRETE ROOFING
BEAM
INCLINED BEAM

EAVES & GUTTER SECTION DETAIL PURLIN CONNECTION SECTION


A
S 08 SCALE 1:10 B DETAIL C FLASHING SECTION DETAIL
S 08 SCALE 1:10 S 08 SCALE 1:10

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
S
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. ROOFING DETAILS

08
DUPLEX HOUSING UNIT JOAN KRYSTAL T. PUBLICO
DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA CIVIL ENGINEER

08
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER DATE 01-08-08
REG. NO. 109017 DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE LIC. NO. 2601671 DATE 11-20-20
LEGENDS AND SYMBOLS

1 2 3 1 2 3 CO
DUPLEX CONVENIENCE OUTLET

WATERPROOF DUPLEX CONVENIENCE OUTLET


WP-CO

REFRIGERATOR CONVENIENCE OUTLET


16000 16000 REF

8000 8000 8000 8000


3000 5000 5000 3000 3000 5000 5000 3000 RANGE
RANGE CONVENIENCE OUTLET

ACU
AIRCONDITIONING UNIT CONVENIENCE OUTLET

PROPERTY LINE PROPERTY LINE CEILING LIGHTING OUTLET

PROPERTY LINE

PROPERTY LINE
2000

2000

2000

2000
ROOF LINE S1 SWITCH, 1-GANG,FLUSH TYPE W/ PLATE & COVER

A S1 c S1 c
A S2 SWITCH, 2-GANG,FLUSH TYPE W/ PLATE & COVER
REF RANGE S1 d S1 d RANGE REF
d d
2050

2050

2050

2050
CO CO 3-WAY SWITCH, 1-GANG,FLUSH TYPE
f h h f S 3W
ACU* ACU* W/ PLATE & COVER
S1 S1

B M
c
S3w e S 3w e
c
M B CO
2S3w 2S 3w
CO 2S 3W
3-WAY SWITCH, 2-GANG,FLUSH TYPE
W/ PLATE & COVER
10000

10000

10000

10000
6000

6000

6000

6000
M KILOWATT-HR METER
CO CO
CO CO
3950

3950

3950

3950
a b b a g i i g
ACU* S1 S1 ACU* ELECTRIC SERVICE ENTRANCE
CB-01 CB-01
CB-01 CB-01
WP-CO WP-CO
PROPERTY LINE

PROPERTY LINE
CO CO LIGHTING PANEL, IN NEMA 1 ENCLOSURE
S3w g S 2 ab S 2 ab S 3w g

C C
2000

2000

2000

2000
ROOF LINE ROOF LINE ROOF LINE ROOF LINE

3000 2850 2150 1575 3425 3000 3000 2850 2150 1575 3425 3000
8000 8000 8000 8000 GENERAL NOTES :
16000 16000

1. THE ELECTRICAL INSTALLATION HEREIN SHALL BE


DONE IN ACCORDANCE WITH THE PROVISION OF
THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE , THE EXISTING LOCAL ORDINANCES,

A GROUND FLOOR ELECTRICAL LAYOUT B SECOND FLOOR ELECTICAL LAYOUT RULES & REGULATIONS
OF LOCAL ENFORCING AUTHORITY & REQUIREMENTS OF THE
E 01 SCALE 1:100 E 01 SCALE 1:100 LOCAL POWER COMPANY

2. THE TYPE OF POWER SERVICES TO BE SUPPLIED SHALL BE


230VAC,SINGLE PHASE, 2 WIRE, 60HZ SECONDARY SERVICES ENTRANCE

3. WIRING METHOD SHALL BE DONE IN RIGID NON METALLIC PVC


CONDUIT TYPE UNLESS OTHERWISE INDICATED IN PLAN

4. ALL MATERIALS TO BE USED SHALL BE NEW AND OF THE APPROVED


TYPES AS TO LOCATION AND PURPOSE INTENDED. PROVIDE PULL BOX WHENEVER NECESSARY
EVEN WHEN NOT INDICATED IN DRAWING.

5. MINIMUM SIZE OF WIRE AND CONDUIT SHALL BE 2.0 MM² THHN AND
20MMØ RIGID PVC PNS:14 TRADE SIZE RESPECTIVELY.
SCHEDULE OF LOADS: ELECTRIC SERVICE ENTRANCE 2-8.0mm² THHN +
SINGLE PHASE 6. STANDARD TYPES OF ACCESSORIES, SPLICING DEVICES TERMINATION AND OTHER
1-3.5mm² THHN (G) APPURTENANCE OF THE ENTIRE ELECTRICAL INSTALLATION SHALL BE USED.
LP NEMA 1 ENCLOSURE, FLUSH MOUNTED IN 20mm Ø RSC PIPE
CKT. BRANCH CIRCUIT HOME RUN M 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONSULTING AND COORDINATING POWER WITH
LOAD DESCRIPTION V Va Amp AT AF P KAIC TYPE THE LOCAL POWER COMPANY AS
NO. WIRE SIZE CONDUIT SIZE
REGARDS TO SERVICE CONNECTION REQUIREMENTS.
1 LIGHTING 13-100VA 230 1300 5.65 2-3.50mm² THHN 20mm Ø RIGID PVC 15 50 2 10 BOLT-ON MAIN 60 AT
8. MOUNTING HEIGHTS HERE UNDER SHALL BE AS FOLLOWS
2 POWER 6-200Va 230 1200 5.22 2-3.50mm² THHN 20mm Ø RIGID PVC 20 50 2 10 BOLT-ON 15 AT 20 AT TUMBLER SWITCH ...........................................1.40 M
3 RANGE 1-200Va 230 200 0.87 2-3.50mm² THHN 20mm Ø RIGID PVC 20 50 2 10 BOLT-ON 1 2 ABOVE FLOOR FINISH
20 AT 30 AT CONVENIENCE OUTLET .................................0.30 M
4 REF/ACU 3-2000Va 230 6000 26.09 2-5.50mm² THHN 20mm Ø RIGID PVC 20 50 2 10 BOLT-ON ABOVE FLOOR FINISH
3 4 PANEL BOARD.................................................1.60 M
5 SPARE 230 1500 6.52 SPARE ABOVE FLOOR FINISH
TOTAL 10,200 44.35 5 COUNTER TOP OUTLET.....................................0.30 M
ABOVE WORKING TABLE
COMPUTATION/ FEEDER SIZE COMPUTATION:
9. THE CONTRACTOR SHALL SECURE ALL NECESSARY WIRING PERMITS,
IL= 10,200
230 x 100% DF.
IL AT 100% DEMAND
CERTIFICATE OF THE ELECTRICAL INSPECTION AND PAY ALL
USE: 2-8.00mm² THHN + THE FEES NECESSARY THERE TO.
IL= 44.35 AMPS 2-3.5mm² THHN IN 20mm Ø RSC PIPE
C SINGLE LINE DIAGRAM 10. OPEN WIRING INSTALLATION SHALL BE RUN IN PARALLEL WITH AND/OR AT RIGHT ANGLE TO
TRUSSES AND COLUMNS, DIAGONAL RUNS SHALL NOT TO BE PERMITTED. PROVIDE CONDUIT
E 02 SCALE 1:NTS CLAMP ON CONDUITS TO ENSURE FIRM ANCHORAGE.

11. ALL INSTALLATION HEREIN SHALL BE DONE UNDER THE DIRECT


SUPERVISION OF LICENSED ELECTRICAL ENGINEER OR
MASTER ELECTRICIAN.

12. SUBMIT AS-BUILT PLANS OF COMPLETED ELECTRICAL INSTALLATION

13. PROVIDE LOCKNUT AND ADAPTOR TO ALLATTACHMENT


CONNECTIONS OF PIPES & METAL FRAMES OR BOXES.

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

PROPOSED TWO STOREY 60 SQM.


PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL ELECTRICAL LAYOUT &
ELECTRICAL NOTES/
REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
E
SINGLE LINE DIAGRAM/ LOAD SCHEDULE
DUPLEX HOUSING UNIT ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA DATE:
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER, 01
LOCATION:
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE
GENERAL MANAGER
DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
01
LEGEND

SIZE DESCRIPTION LINE TYPE

GENERAL NOTES:
100 mm Ø SOIL WASTE PIPE
1. ALL PLUMBING WORKS TO BE DONE AND SIZES OF TH PIPES 6. ALL CHANGES IN DIRECTION SHALL BE MADE BY THE APPROPRIATE USE OF 12. USE UPLASTICIZED POLYVINYL CHLORIDE (uPVC) FOR ALL WATER PIPING SYSTEM.
100 mm Ø STORM DRAINAGE PIPE
TO BE USED SHALL BE IN ACCORDANCE WITH THE LATEST FORTY FIVE (45) WYE LONG SWEEP QUARTER BEND. ONE EIGHT WHEN THE 13. USED uPVC SANITARY PIPING SYSTEM SERIES 1000 FOR 100Ø AND SMALLER AND

SBR-34 GRAVITY SEWER MAIN uPVC PIPING SYSTEM FOR 150Ø AND BIGGER. 100 mm Ø DOWNSPOUT
EDITION OF UNIFORM PLUMBING CODE OF THE PHILIPPINES CHANGE OF FLOW IS FROM HORIZONTAL TO VERTICAL A SINGLE BEND

AND LOCAL REGULATIONS AND ORDINANCES. COMBINATION MAYBE USED ONLY ON VENT PIPE. 14. ENGINEER-IN-CHARGE TO VERIFY ACTUAL LOCATION AND ELEVATION OF STREET 50 mm Ø VENT PIPE

2. ALL PIPES SHALL BE INSTALLED AS INDICATED IN THE WORKING 7. NO DOUBLE HUB OR DOUBLE TEE BRANCH SHALL BE USED ON HORIZONTAL DRAINAGE,STREET SEWER AND STREET WATER MAINS FOR CONNECTION BEFORE
20 mm Ø COLD WATER LINE
DRAWINGS. ANY RELOCATION REQUIRED FOR PROPER EXECUTION SOIL AND WASTE LINES. CONSTRUCTION.
100 mm Ø WATER CLOSET
OF OTHER TRADES SHALL BE UPON THE APPROVAL OF SANITARY 8. PROVIDE PIPE SLEEVES AT WALL, COLUMNS OR SLAB TO PROTECT FROM
100 mm Ø ROOF DRAIN
SANITARY ENGINEER. BREAKAGE.

3. ALL PIPES SHALL BE PROVIDED BY PROPER HANGER AND SUPPORT. 9. ALL SLOPES FROM HORIZONTAL DRAINAGE PIPES SHALL MAINTAIN 1% 50 mm Ø

4. ALL FIXTURES SHALL BE VENTED INDIVIDUALLY AND WATER LINES UNLESS OTHERWISE SPECIFIED.

SHALL BE VALVE BY GROUP. 10. THE BRAND AND OTHER DETAILED PLUMBING FIXTURES SHALL BE IN ACCORDANCE
GT GREASE TRAP
5. ALL PLUMBING FITTING SHALL BE ACCESSIBLE FOR MAINTENANCE. WITH THE SCHEDULE FURNISHED BY THE ARCHITECT.
STORM WATER FLOW
PROVIDE MANHOLE IF SUCH INSTALLATION ARE INSIDE THE CEILING. 11. GATE VALVE SHALL BE BRONZE BODY, SOLID WEDGE TYPE, SCREWED OR FLANGED END.

CO CLEAN OUT

CB CATCH BASIN

1 2 3

50 mmØ VENT STACK THROUGH ROOF PVC PIPE

50 mmØ VENT STACK THROUGH ROOF PVC PIPE


LOCATION OF LOCATION OF
A
SEPTIC TANK / PPST
CB 50mm Ø VSTR CB CB 50mm Ø VSTR CB
SEPTIC TANK / PPST
1
100mm Ø SEWER PVC PIPE 100mm Ø SEWER PVC PIPE
B SE LO
PT C
A CO
LAV LAV
CO
IC AT
TA IO
NK N O
/ P F
WC WC PS
FD FD C R PV
C
PIP
E

CO
T
CB 2
WE
SE
Ø

B m
100mm Ø SEWER PVC PIPE

100mm Ø SEWER PVC PIPE


0m
10
FD
LA

FD
V
WC
CB
CB 3
WC
FD FD LA
FD V
EC
TA PIP B CB
C
P
SE TO R PV
WE M WE SE LO
PT C
R AIN SE IC AT
Ø CB CO TA IO
m NK N O
TA 0m
C CB CB CB CB
DRP TO 10
AIN S
AGTOR CB
/ P F
PS
T
E M
E
PIP
VC
100mm Ø SEWER PVC PIPE

100mm Ø SEWER PVC PIPE

RP
CB FD WE
E SE
PIP m
Ø
C 0m
R PV 10
WE
SE
Ø
TA m
0m
TAP TO MAIN TAP TO MAIN DRP TO 10
AIN S
SEWER SEWER AGTOR
E M
TA
P
SE TO
TAP TO STORM TAP TO STORM WE M
R AIN
DRAINAGE DRAINAGE

A SANITARY LAYOUT B SANITARY ISOMETRIC LAYOUT


P 01 SCALE 1:100 P 01 SCALE 1:100

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

PROPOSED TWO STOREY 60 SQM.


PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL SANITARY LAYOUT/ SANITARY
ISOMETRIC
REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
P
LAYOUT/ GENERAL NOTES
DUPLEX HOUSING UNIT ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA DATE:
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER, 01
LOCATION:
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE
GENERAL MANAGER
DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
03
LEGEND LEGEND

SIZE DESCRIPTION LINE TYPE


SIZE DESCRIPTION LINE TYPE

100 mm Ø SOIL WASTE PIPE


100 mm Ø SOIL WASTE PIPE

100mm Ø STORM DRAIN PVC PIPE


100 mm Ø STORM DRAINAGE PIPE
100 mm Ø STORM DRAINAGE PIPE

100 mm Ø DOWNSPOUT
100 mm Ø DOWNSPOUT
A A

100mm Ø STORM DRAIN PVC PIPE


100mm Ø STORM DRAIN PVC PIPE
50 mm Ø VENT PIPE

100mm Ø STORM DRAIN PVC PIPE


B B
VENT PIPE
1 1
50 mm Ø

20 mm Ø COLD WATER LINE

100mm Ø STORM DRAIN PVC PIPE


20 mm Ø COLD WATER LINE

C C

100mm Ø STORM DRAIN PVC PIPE


100 mm Ø WATER CLOSET

100mm Ø STORM DRAIN PVC PIPE


100 mm Ø WATER CLOSET
2 2
CB
E 100
PIP mm
C ØS
PV ROOF DRAIN
ROOF DRAIN AIN
TO
RM 100 mm Ø
100 mm Ø DR DR
AIN
RM PV

100mm Ø STORM DRAIN PVC PIPE


STO C PC
IPBE
Ø LA
mm V 20 50 mm Ø
3 3
50 mm Ø
mm
0 CB
10
Ø
CW
FD WC 100 L
mm
WC ØS
TO 20
mm
CB RM Ø
FD LA DR CW
L
V AIN
10P0 IPE PV
C
VC mm
L
C
PIPB CW
P ØS E m
Ø
L GT GREASE TRAP
GT GREASE TRAP AIN
m CW
TO 20 Ø
DR RM mm
D RA
20
RM IN P
STO VC
Ø PCIPB STORM WATER FLOW
STORM WATER FLOW TA 00
mm E E
PIP
CV
DR P TO 1 C
GVM
GVM
CV
AIN S 100 PV
AGTOR mm IN
E M ØS DR
A CO CLEAN OUT
CO CLEAN OUT TO
R MD R M
RA STO
IN P Ø
VCPIPE m
CATCH BASIN
C PIPE C 10
0m CB
CB CATCH BASIN PV B
AIN
DR
R M
STO
Ø
TA m
0m
DR P TO 10
AIN S
AGTOR
E M

B STORM DRAINAGE ISOMETRIC LAYOUT D WATER LINE ISOMETRIC LAYOUT


P 02 SCALE 1:100 P 02 SCALE 1:100

1 2 3 1 2 3

CB 100mm Ø STORM DRAIN PVC PIPE CB CB 100mm Ø STORM DRAIN PVC PIPE CB

A LAV LAV
A 20mm Ø CWL 20mm Ø CWL

WC WC
FD FD

B B
100mm Ø STORM DRAIN PVC PIPE

100mm Ø STORM DRAIN PVC PIPE

20mm Ø CWL

20mm Ø CWL
C C
CB CB
100mm Ø STORM DRAIN PVC PIPE CB 100mm Ø STORM DRAIN PVC PIPE
CV CV
M M
100mm Ø STORM DRAIN PVC PIPE

100mm Ø STORM DRAIN PVC PIPE

GV GV

TAP TO STORM
DRAINAGE
TAP TO STORM
DRAINAGE
C WATER LINE LAYOUT
P 02 SCALE 1:100

A STORM DRAINAGE LAYOUT


P 02 SCALE 1:100

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
P
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL STORM DRAINAGE LAYOUT/ STORM DRAINAGE REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. ISOMETRIC LAYOUT/ WATER LINE LAYOUT
WATER LINE ISOMETRIC

02
DUPLEX HOUSING UNIT DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA

03
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER
DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE
2000

750 600 650

100 600 100 500 100 500 100

INLET

100

200 CO
CO CO
2000

750 600 650

MH MH MH
100 600 100 500 100 500 100
1100

900

500

3 50 500 50 50 400 50 50 400 50


10MM ∅ @ 0.20M O.C BOTH WAYS
A-2

50 400 50
200

MH MH MH
CO CO CO CO

100
FIN. GROUND LINE 100 MM ∅ PVC SP
100

250
300
100MM THK CONCRETE
SLAB WITH 10MM ∅ @ 0.20M O.C

A SEPTIC VAULT PLAN OUTLET

P-3 SCALE 1:50


LEVEL OF 100 MM ∅ PVC
SCUM OUTLET PIPE TO
STREET SEWER
(VERIFY CONNECTION)

2000 DIGESTIVE LEACHING LEACHING


CHAMBER CHAMBER 1 CHAMBER 2

1300
1600
750 600 650
100MM THK CHB WALL WITH
10MM ∅ VERT. BAR SPACED @ 0.50M O.C &

1000
10MM∅ HOR. BAR CHB IN PLAIN PLASTER FIN
WITH CEMENTITOUS WATER PROOFING
100 600 100 500 100 500 100

100MM THK CONCRETE


SLAB WITH 10MM ∅ @ 0.20M O.C PROVIDE
BOTH WAYS CEMENTITOUS
WATERPROOFING
GRAVEL BED
100

CO CO

150
CO IN)
PE(M
200

LO
2% S

200
100 MM THK CONRETE SLAB
WITH 10MM ∅ RSB SPACED @ 0.25 M
O.C BOTHWAYS

MH MH MH
1100

900

500

CONCRETE COVER
(MANHOLE) 50 MM GRAVEL FILL

300 300
200

CO

C SEPTIC VAULT SECTION DETAIL


P-3 SCALE 1:50
100

1-10MMØ EXTRA
DIAGONAL BARS @ EVERY
MANHOLE CORNER

B SEPTIC VAULT LAYOUT DETAIL


P-3 SCALE 1:50

PROJECT TITLE: DEVELOPER ARCHITECT/ENGINEER: DRAWN BY: CHECKED BY: OFFICE OF THE PRESIDENT SHEET NO.:
CSB
EU
LD
IERS DATE: DATE: NATIONAL HOUSING AUTHORITY
STA. MONICA HOMES
P
PHASE 6, BLK 1, LOT 10, EASTWOOD, GREENVIEW
SHEET CONTENT: ELLIPTICAL ROAD, DILIMAN, QUEZON CITY

SUBD. SAN ISIDRO, RODRIGUEZ, RIZAL REVIEWED BY: RECOMMENDING APPROVAL: APPROVED BY:
PROPOSED TWO STOREY 60 SQM. SEPTIC VAULT DETAIL

03
DUPLEX HOUSING UNIT DATE: ATTY. RONY A. LAGMAY MELIZA S. BENEDITO AR. SUSANA V. NONATO MARCELINO P. ESCALADA, JR
CHRISTOPHER M. ESTRELLA

03
DISTRICT MANAGER REGIONAL MANAGER HEAD, AFP-PNP GENERAL MANAGER,
LOCATION: GENERAL MANAGER
DISTRICT 1 REGION 1/CAR HOUSING PROGRAM NATIONAL HOUSING AUTHORITY
BRGY. STA ASUNCION, SAN NICOLAS, ILOCOS NORTE