AKRONEX CO2
Carbon Dioxide Fire Suppression Systems
Features and
Advantages
• No ozone damage,
• Physical extinguishing,
• Used for local extinguishing purposes,
• Not used in areas where human presence,
• The cost of refilling is low, widely available,
• The discharge time is 60 seconds,
(30 seconds for local systems).
• The minimum discharge time calculated according to Usage Areas
the standards should be 60 seconds.
• For local applications, the discharge time should be at Several fire extinguishing applications where CO2 is
least 30 seconds. suitable are listed below.
• If longer cooling time is required to complete the
extinguishing process, the discharge time can be • WPP (Wind Power Plant), HEPP,(Hydroelectric Power
increased. Plants),
• SPP (Solar Power Plants) and GPP(Geothermal Power
AKRONEX C02 Discharge Time Plants),
• Electrical equipment (machines, transformers, etc.),
Carbon Dioxide Fire Suppression Systems • The minimum discharge time calculated according to
• Painting cabinets, industrial ovens, etc,
• Electronic control units and data processing centers,
the standards should be 60 seconds. • Closed storage areas, dust pipes, and tunnels etc,
Carbon dioxide is a colorless, scentless and non This fire suppression can be applied in areas such as • For local applications, the discharge time should be at • Closed frame spinning machines,
conductive gas that can effect quickly and efficiently into transformer rooms where people are not always present least 30 seconds. • Silos, archives, flammable liquid storage areas.
the protected area. Its density is about 50% higher than when appropriate safety measures are provided. After • If longer cooling time is required to complete the
the air density. completing the suppression system, the area must be extinguishing process, the discharge time can be
During extinguishing, it is seen as a white mist. It does
not make residue on the materials or affect adversely the
adequately ventilated. Because the density of carbon
dioxide gas is heavier than air, it accumulates at low.
extended.
Cylinder Storage
materials.
Reduces the concentration of oxygen causes suppression CO 2 is stored in pressurized cylinders up to 60 bar at 21°C. Containers
to fire in the space and creates a cooling effect causedby The distribution system consists of a series of 67.5-liter
rapid expansion of the gas. cylinders, which are tested at 250 bar, charged using a The cylinders of AKRONEX CO2 Fire Suppression System’s
Even if the CO2 concentration is low in concentration, it filling factor of 0.75 Kg / L or 0.67 Kg / L, with cylinders can be fixed and stored in the container according
should not be ignored and considered to be a danger to maximum storage temperatures of 40 °C and 50 °C. to the customer request. This solution provides ease of
breathing. Also, the visibility during discharge is greatly maintenance, transportation and installation. This creates a
reduced due to the formation of CO2 mist. more secure environment.
2 akronex.com akronex.com 3
Akronex CO2 Valves Akronex CO2 Weighing Devices
Akronex CO2
* The valves are equipped with safety features to prevent leakage. Weighing System
Gas leakage in the
cylinders can be measured
CO2 Master Valve by weighing the cylinders
Article No. F20310xx and using special test
System Type Carbon Dioxide U= 24V DC
0036
devices. In order to
P= 9.3W continuously monitor
Inlet Thread ISO 11363-1 25E IP65 the amount of gas in the
Outlet Thread W21,8x1/14”
cylinder in AKRONEX CO2
Burst Discs 190 Bar systems, the special design
CO2 Master
PT 2 5 0 b a r
0036
PS 1 7 4 b a r
- 30/ 60℃
MM/ YY
0036
22 280 System can be installed
200bar
optionally.
0036
22
200bar
0036
280
200bar
0036
MM/ YY
22 - 30/ 60℃
PS 1 7 4 b a r
PT 2 5 0 b a r
22
22
200bar
200bar
280
0036
0036
MM/ YY
280
0036
CO2 Pneumatic
MM/ YY
- 30/ 60℃
- 30/ 60℃
PS 1 7 4 b a r PS 1 7 4 b a r
PT 2 5 0 b a r
PT 2 5 0 b a r
Valve
22 280
0036
0036 200bar
MM/ YY
- 30/ 60℃
PS 1 7 4 b a r
PT 2 5 0 b a r
- 30/ 60℃
4 akronex.com akronex.com 5
®
Yangın Alarm Sistemi
ELECTRONIC
Finder elektronik yangın alarm siren flaşörü 4
farklı ton, sabotajlara karşı kilitlenme ve dahili
veya harici kullanım gibi çok yönlü özelliklere
sahiptir.
SYSTEM PARTS
şartları içererek iyi duyulabilirliği sağlar.
Ayrıca yetkisiz kişilerin müdahale etmesini
engelleyici kilitlenebilir tabanı bulunmaktadır.
Ölçüler ø:100mm
Y: 58mm
Koruma Sınıfı IP 40
Opsiyonel IP 55
Yangın ve Gaz Alarm Sistemleri Acil Anons Sistemleri Geçiş Kontrol Sistemleri Bina Yönetim Sistemleri Acil Aydınlatma
www.finder.com.tr
EP203 Automatic
Certified to EN12094-1 and EN54-2/4 by the
Approvals/certifications
LPCB (176c) / (0832-CPD-0794).
Extinguisher Panel
Mains supply 230V 50/60Hz.
Mains rated current 810mA max.
19V-28.5V (27V nominal). Ripple 7V maximum
Internal power supply
(battery fault)
No. of detector zone circuits 3 @ 19-28Vdc (Max. length per circuit is 250m)
439 W x 276 H x 70 D mm (back box); 467 W x People who benefit more from nature and
Product dimensions (mm)
293 H x 29 D mm (lid). world blessings by the development of
Weight 4.2kg (without batteries).
technology have also caused to occur
Operating conditions/
temperature
-5°C to +40°C. Max relative humidity: 95%. pollution at the same time.
IP Rating IP30.
Carbon dioxide fire protection systems are
a responsible choice to protect nature.
Product Code Explanation Specifications
ECO 1003
Photoelectric Smoke
24VDC Systems
• Remote alarm test and Multi
Detectors
Detector feature
• Easy Maintenance
Rate of Rise Thermal
ECO 1005
Detector
6 akronex.com akronex.com 7
Worldwide Solutions
In Automatic Fire Suppression Systems