Screw-In Direct Operated Pressure Relief Valve (DBDE04) For Use in Manifolds
Screw-In Direct Operated Pressure Relief Valve (DBDE04) For Use in Manifolds
Product Overview
Direct operated DBD valves can be used to safely limit the
maximum permissible pressure, where necessary, in
hydraulic systems.
Advantages
• Maximum inlet pressure, p = 420 bar
• Space saving screw-in installation in manifold blocks –
no additional cover necessary. T
• Optional cap available to cover and protect the pres-
sure setting.
• Also available in a factory preset version with tam- P
perproof cap.
Flow direction - - P T
Operating pressure max. bar Inlet port, P = 420; Outlet port, T = 210 bar
Ambient °C -30 to +80 for NBR seals
-
temperature-range °C -20 to +80 for FKM seals
- - NBR* : Mineral oil based, HFB, HFC hydraulic fluids
Seals/
- - FKM** : Mineral oil based, HFD hydraulic fluids
Oil compatibility
- - Compatibility with other hydraulic fluids on request
Fluid -30 to +80 for NBR seals
- °C
temperature range -20 to +80 for FKM seals
Viscosity range min. mm²/s 15
(recommended) max. mm²/s 46
Viscosity range min. mm²/s 2,8
(max allowable) max. mm²/s 380
Cleanliness level
ISO 4406 Class 20/18/15
(functional reliability)
Cleanliness level
ISO 4406 Class 17/14/11
(long life)
MTTFd Value
Years 150
(ISO13849-1)
P-Q Curves
Standard Version
Pressure setting at 5 L/min. Pressure settings below the shown curve are
not possible.
Pressure setting at 5 L/min. Pressure settings below the shown curve are
not possible.
51 (up to 65 possible)
max 12.5 to thread run out
Rmax 0.8 or
chamfer max 0.8x45°
Type designation
Common Configurations
Dimensions
Seal Kits
Accessories
5
Pos. Description Order number
4
Adjustment 8 & 9
(6,7) XEB18992-000-00
(Cap, set screw, wire & lead seal) 8
Alle Rechte
©2015 Moogvorbehalten.
Inc. All rights reserved. All changes are reserved.
DBDE04-DE / 06_2014
DBDE04-EN 07_2014