TimeScan/NMS
Administrator’s Guide
Release 5.4

Copyright © 1999 Symmetricom, Inc. All rights reserved. Printed in U.S.A.


Issue 1: Sep 99 TMSL 197-46600-01

Administrator Guide Contents

Chapter 1.............................................. Managed Object Configuration

Chapter 2.....................................................................Security Manager

Chapter 3........................................... Fault Management Configuration

Chapter 4.................................................................... Alarm Forwarder

Chapter 5.................................................................. Process Supervisor

Chapter 6........................................................ Database Administration

Chapter 7..................................................................Fault Configuration

Chapter 8.......................................................................Troubleshooting

Page i(ii)
TMSL 197-46600-01 Issue 1: Sep 99

(This page intentionally left blank)

Page ii(ii)
Issue 1: Sep 99 TMSL 197-46600-01

Introduction

Welcome to the Administrators Guide for the TimeScan/NMS Suite of applications.


The tools within the suite are used for administration and troubleshooting and this
introduction describes each one of them and outlines its use.

Introduction Page 1(4)


TMSL 197-46600-01 Issue 1: Sep 99

Managed Object Configuration


Managed object configuration provides the ability to define new or modify existing, managed
elements. This chapter provides a step-by-step description of how to define the existence of a new
DCD element, include a new Network Browser view and make these new objects accessible to the
operator.

Managed Object Configuration is launched by selecting Managed Object Configuration icon from
the TimeScan/NMS Administrator item, on the Windows Start menu or the Unix CDE Front Panel.

Page 2(4) Introduction


Issue 1: Sep 99 TMSL 197-46600-01

Figure 1 The Unix CDE Front Panel / Windows Start Menu

Security Manager
The TimeScan/NMS Server has an in-built protection scheme against unauthorised users from
accessing and manipulating the elements managed from the platform. The chapter describes how
the Security Manager works and how the sub-system should be maintained.

Introduction Page 3(4)


TMSL 197-46600-01 Issue 1: Sep 99

The Security feature application is launched by selecting the Security Manager icon from the
TimeScan/NMS Administrator item on the Windows Start menu or the Unix CDE Front Panel
(Figure 1).

Fault Management Configuration


All alarms within the TimeScan/NMS system have an ID and a mapping for severity. Using this
facility incoming alarm IDs can be configured and the severity mapping can be amended. If a
mapping is changed it will only be effective on new alarms which are received after the amendment
has taken place.

Alarm Forwarder
NMS may be set-up to forward alarms to an external system. The external system must listen on a
TCP/IP socket and receive textual based alarm/event and clearing messages once a connection has
been established. This document will describe how to set-up the NMS to forward alarm, including
criteria that can be set, and the format of the forwarded messages.

Database Administration
The Database Administration chapter discusses archiving of the alarm database as well as viewing
of archived data. This chapter discusses how to plan and perform basic maintenance tasks. The
Maintenance schedule is a list of tasks that must be performed on a regular bases (daily, weekly,
monthly), to keep the system running smoothly.

Troubleshooting

NMS Console

This facility reports internal TimeScan/NMS events. If a problem arises with the system,
which prevents communication use this console to record any faults. Information
recorded should be included when any faults are reported.

NMS Free Text Console

This facility is similar to the NMS console except it reports all output of the TimeScan/
NMS system and not just alarms and faults.

Page 4(4) Introduction


Issue 1: Sep 99 TMSL 197-46600-01

Managed Object
Configuration

A common requirement of any management system is the ability to define new, or


modify existing, managed elements. This chapter provides a step-by-step
description of how to define the existence of a new DCD element, include a new
Network Browser view and make these new objects accessible to the operator.

Managed Object Configuration Page 1(24)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Contents

Opening The Application ..................................................................... 3


The Managed Object Configuration Database .................................... 4
Sub-Networks ............................................................................ 5
Managed Elements .................................................................... 6
Managed Object Configuration Hierachy View ........................ 7
The Toolbars ........................................................................................ 7
Main Toolbar .............................................................................. 8
Preview Toolbar ......................................................................... 8
Create New Object ............................................................................... 9
Attributes For Managed Element (ME) ................................... 11
Attributes For Sub-network (SN) ............................................ 15
Attributes For National Manager (NM) .................................. 16
Toolbindings ............................................................................ 17
Remove Object .................................................................................. 18
Edit Object ......................................................................................... 18
Edit Object Attributes .............................................................. 18
Edit Object Name .................................................................... 18
Move Object ...................................................................................... 18
Copy Object ....................................................................................... 19
Link Object ........................................................................................ 19
Preview Network ............................................................................... 20
Change Background Image ..................................................... 20
Change Style ............................................................................ 21
Test .......................................................................................... 21
Save ......................................................................................... 21
Using Imported Graphics In A Client / Server Setup.............. 22
Chapter Index ..................................................................................... 23

Page 2(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Opening The Application


The first task in defining a new Digital Clock Distributor (DCD) element is to insert a new entry
into the Managed Object Configuration Database.
In the TimeScan/NMS Administrator menu (in the Windows Start menu or Unix CDE Front Panel)
is an entry for a tool, Managed Object Configuration item, which will enable us to do this.

Figure 1 The Unix CDE Front Panel / Windows Start Menu

Selecting this icon will produce the Hierarchy View Window (page 7) which will provide access to
information on all the objects defined within the Managed Object Configuration Database.
Before we look at the creating a new DCD element, let’s look at the Managed Object Configuration
Database.

Managed Object Configuration Page 3(24)


TMSL 197-46600-01 Issue 1: Sep 99

The Managed Object Configuration Database


The purpose of the Managed Object Configuration Database is to provide a store for all the
information required by the system to realise and manage an arrangement of objects and elements.
The distinction is made between objects and elements, because not only does the TimeScan/NMS
System support the existence of Managed Elements (ME’s), it also supports the existence of virtual
objects i.e. objects that do not have any tangible form.
In general these virtual objects form containers which may contain managed elements or other
virtual objects. For example, a network is a virtual container - it contains managed elements.

The true value of virtual objects is their ability to define logical partitions in a network providing
context and rationalisation for the user. Consider a network containing 100 elements. The main
purpose of any network presentation system is to display the current notification state of all the
elements in the network. To attempt this on one graphical view would result in a confusing clutter.
However, if elements can be grouped together in containers and the containers displayed then the
view can be simplified without losing status resolution.

The following figure provides a typical example of how such a network may be defined:

Network

Containment

Region 1 Region 2 Region 3 Region 4 Region 5

Virtual Object

Managed Element

Six virtual objects are created. Network contains five Regions which in turn contain all the managed
elements. Immediately the task of depicting and understanding the network because greatly
simplified. These virtual objects are known as Sub-Network Objects because, in general, they
represent parts of a network.

Page 4(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Sub-Networks

Sub-Network Objects have a special property which causes them to exhibit the same
notification status as all the managed elements directly or indirectly contained within
them. Therefore in the previous example the requirement to depict the notification state
of all the elements in the network is fulfilled because each region will depict a notification
status which will represent the summation of the notification states of all the managed
elements contained within the region.
Any structure of Sub-Networks can be defined. A popular arrangement is to mimic the
physical or conceptual containers found in the network, for example:

Network

Contains

Region

Contains

Office

Contains

Cabinet

Contains

Element

Managed Object Configuration Page 5(24)


TMSL 197-46600-01 Issue 1: Sep 99

There is no limit on how many Sub-Networks can be defined or what is contained within
them. It is also perfectly legal to have an object, either a Sub-Network or Element,
contained by multiple Sub-Networks.
For example: consider two simple SDH ring structures...

DCD1

Ring A
DCD4

DCD3
Ring B

DCD2

DCD5

We could define Ring A and Ring B as two Sub-Networks. However, the element DCD3
exists in both rings. This does not cause a problem as DCD3 may be contained within
Ring A Sub-Network and Ring A Sub-Network. If the notification status of DCD3
changes then the change will be propagated to both Ring A and Ring B.

Managed Elements

Managed Elements are defined as equipment, i.e. DCD Elements, directly managed by the
local TimeScan/NMS platform. Although it is possible to define a managed element as
containing another Managed Element it should be noted that notification status will not
be propagated to the containing managed element.

Page 6(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Managed Object Configuration Hierachy View

When the Managed Object Configuration application has been launched you will be
presented with the main hiearchy view window, this is where you will be able to configure
the system by adding, deleting and modifying objects in the database.

The Toolbars
There are two toolbars that are used to configure the system. The first is present when the main view
(above) is being displayed. The second is used when previewing a sub-network.
All of the options that are available through the toolbars are available from the drop down menus.

Managed Object Configuration Page 7(24)


TMSL 197-46600-01 Issue 1: Sep 99

Main Tool Bar

The options on this toolbar are (from left to right):


Copy object - This option is only available when an object other that the root is
selected. When this button is pressed a copy of the current object is taken for future use
(see Paste Object and Link Object, below)
Paste object - Once an object has been copied (see above), selection of this button
will make a copy of the object at the current location. The new object will be prefixed with
the words “copy_of_”. This option will remain ‘greyed out’ until an object has been
copied and the destination is not the root object.
Link object - Once an object has been copied (see above), selection of this button
will create a link to the copied object at the current location. Any changes made to the
original object will automatically be made to the linked object. This option will remain
‘greyed out’ until an object has been copied and the destination is not the root object.
Delete object - Selection of this option will delete the current object from the system,
if the object is a sub-network all contained objects will be moved to the root of the system.
Refresh from server - Selection of this button will refresh the system from the
server.

Preview Tool Bar

This tool bar will be available when the system is in preview mode, accessed by selecting
preview from the drop down menu that appears when a sub-network is selected with the
right mouse button.

The available buttons are (from left to right)


Save -When a change has been made to the preview this button becomes active,
when selected the changes that have been made will be updated to the database.
Change background image - When this button is selected a dialogue is displayed
that allows the selection of a new background image for the preview. Note: the image
must be a bitmap file.
Test - When this option is selected, selecting an object will allow you to test the
currently selected toolbindings. i.e. selecting an object with the right mouse button will
produce a popup menu with the available tools.
Change style - Selection of this button will produce a dialogue that allows you to
set the style of the icons and alarm bars.

Page 8(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Create New Object


To be able to create a new object in the system we must be at the main hierachy view window.
First select either the root object or a sub-network from the tree in the hierachy view then bring up
the popup menu by selecting with the right mouse button. Then select Add new object... from the
available list of objects. You will then be presented with the following dialogue.

You must then enter a unique identifier in the Distinguished Name text box. The name must not
contain any spaces.
You must also select an object class from one of the available options. The dialogue will change
depending on the choice that is made. These options will be discussed in later sections of this
document.

Managed Object Configuration Page 9(24)


TMSL 197-46600-01 Issue 1: Sep 99

Preview Icon specifies the path to a bitmap image (*.bmp) which will be used to depict this object.
The system is capable of displaying any size icon image. On selecting the square button
immediately to the right of the Icon Image field a file selector window will be opened. The selector
will automatically be scoped to the correct file type (*.bmp) and will point to the root of the
directory structure set aside for icon graphics:

However, this path is not mandatory and may be modified. It should be noted, that if the path or file
is subsequently renamed or deleted then the system will not be able to locate the icon image and an
error message will be generated.

Page 10(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Attributes For Managed Element (ME)

When Managed Element is selected into the object class option the dialogue box will
change and look like this:

Object Type is an attribute which conveys type information for objects of class ‘Managed
Element’. If the object is of class ‘Sub-Network’ no type information is required and this
field should be left blank.
Object Version is an attribute which conveys variant information for objects of class
‘Managed Element’. If the object is of class ‘Sub-Network’ no variant information is
required and this field should be left blank.
Object Location is an optional attribute which may be used to convey the physical
location of the object, e.g. “12th Street Office / Rack TQ1-0”.

Managed Object Configuration Page 11(24)


TMSL 197-46600-01 Issue 1: Sep 99

Source Identifier is an attribute which defines the unique identifier string the element
reports to identify itself. This attribute is mandatory for elements that communicate with
the local TimeScan/NMS Server via PSTN modem.
UserId is a mandatory field is used to establish communications with the element. A user
identity should be selected from the pull down list provided.
Password is an a mandatory field which is used to establish communications with the
element. The password should be the appropriate password for the user identity selected
in the UserId field. The password string is not displayed but is implied by a string of
asterisk characters.
Protocol is a redundant field for this application.
Source Address (Fault Management Address) is a mandatory parameter only in the
unusual situation where the address from which the managed element reports spontaneous
alarms differs from the ‘Prime Transport’, address.
Primary Transport defines the communication method which is considered to be the
primary method for this element. The TimeScan/NMS System supports two basic forms
of connection - permanent and session based.
Permanent connections are recommended for IP and direct serial communication where
spontaneous alarm message are sent over the same communications channel as
configuration actions. On system start-up all permanent connection are established.
Therefore, changes to permanent connection, either modification, addition or deletion
will only be applied when the TimeScan/NMS services are restarted. If a permanent
connections has failed, periodic attempts will automatically be made to re-establish the
connection.
Session based connections are recommended for Modem and X.25 communications.
The TimeScan/NMS System is capable of supporting two forms the communication
transport methods for each managed element. The primary method is always attempted
first, if this method fails, the system will automatically revert to the backup method if one
is defined. Select the appropriate transport method form the list provided.
Primary Target Address (Prime Configuration Management Address) defines the
address of the element associated with the primary transport method.
The Prime Configuration Management Address is defined as follows:
For IP communications the transport is defined as:
“inet:” < IP address >:< socket number>
For example:
inet:142.111.11.23:10000
For X.25 communications the Prime Configuration Management Address is defined as:
Remote X25 PAD address + port sub-address

Page 12(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Therefore, if the configuration channel of an element is connected to a remote PAD of


address 12345 and the port sub-address is 6, then the Prime Configuration Management
Address will be:
123456
For PSTN (dial-up modem) communications the Prime Configuration Management
Address is defined as:
COM+internal port assignment+_+PSTN number
Therefore, if the configuration channel of an element is connected to a remote PSTN
modem at PSTN number 01 234 567890, then the Backup Configuration Management
Address will be:
COM1_01234567890
For RS232 serial communications the Prime Configuration Management Address is
defined as:
“COM” + internal port assignment
Therefore, if the configuration channel of an element is connected to local serial port com
1, then the Prime Configuration Management Address will be:
COM1
Source Address(Fault Management Address) is a mandatory parameter only in the
unusual situation where the address from which the managed element reports spontaneous
alarms differs from the Prime Transport address.

Backup Transport defines the communication method which is considered to be the


backup method for this element. Only session based communications are available as
backup transport methods, as failed primary permanent connections will be automatically
re-established where possible. Select the appropriate transport method form the list
provided.
Backup Target Address (Backup Configuration Management Address) defines the
address of the element associated with the backup transport method. This address may be
the same as the Prime CM Address.
The Backup Configuration Management Address is defined as follows:
For IP communications the transport is defined as:
“inet:” < IP address >:< socket number>
For example:
inet:142.111.11.23:10000
For X.25 communications the Backup Configuration Management Address is defined as:
Remote X25 PAD address + port sub-address

Managed Object Configuration Page 13(24)


TMSL 197-46600-01 Issue 1: Sep 99

Therefore, if the configuration channel of an element is connected to a remote PAD of


address 12345 and the port sub-address is 6, then the Backup Configuration Management
Address will be:
123456
For PSTN communications the Backup Configuration Management Address is defined
as:
COM+internal port assignment+_+PSTN number
Therefore, if the configuration channel of an element is connected to a remote PSTN
modem at PSTN number 01 234 567890, then the Backup Configuration Management
Address will be:
COM1_01234567890
For RS232 serial communications the Backup Configuration Management Address is
defined as:
“COM” + internal port assignment
Therefore, if the configuration channel of an element is connected to local serial port com
1, then the Backup Configuration Management Address will be:
COM1
NOTE: For system configurations where there is no backup communication transport
method available and the prime communication transport method is not based upon
permanent connections. It is recommended that the prime transport parameters be
duplicated for the backup transport parameters. This action will cause the system make up
to three consecutive attempts to establish element communications before declaring a
communication failure.
Heartbeat Interval is a user selectable value which dictates the period, in seconds, which
may elapse before the system will attempt to Heart Beat the element. The default, and
recommended, value is 900 seconds (15 minutes).
Heartbeat Surveillance is a box which, when ticked, enables Heartbeat.
Audit After HB is a box which, when ticked, causes the system to automatically perform
an alarm audit on the element when a Heart Beat failure is cleared i.e. when
communications with the element are restored. Alarm Audit is described in more detail in
the User Instruction Manual: Alarm Audit and Heartbeat.

Page 14(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Attributes For Sub-network (SN)

When Sub-Network is selected into the object class option the dialogue box will change
and look like this:

Object Type is an attribute which conveys type information for objects of class ‘Managed
Element’. If the object is of class ‘Sub-Network’ no type information is required and this
field should be left blank.
Object Location is an optional attribute which may be used to convey the physical
location of the object, e.g. 12th Street Office / Rack TQ1-0.
Background Image specifies the path to a bitmap image (*.bmp) which will be used as
a background image by the Network Browser Application.
The system is capable of displaying any size background image. On selecting the square
button immediately to the right of the Background Image field a file selector window will

Managed Object Configuration Page 15(24)


TMSL 197-46600-01 Issue 1: Sep 99

be opened. The selector will automatically be scoped to the correct file type (*.bmp) and
will point to the root of the directory structure set aside for background or map graphics:

However, this path is not mandatory and may be modified. It should be noted, that if the
path or file is subsequently renamed or deleted then the system will not be able to locate
the background image and an error message will be generated.

Attributes For National Manager (NM)

Selection of National Manager in the object class dialogue box will cause the dialogue to
change and look like this:

Object Type is an attribute which conveys type information for objects of class ‘Managed
Element’. If the object is of class ‘Sub-Network’ no type information is required and this
field should be left blank.

Page 16(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Object Version is an attribute which conveys variant information for objects of class
‘Managed Element’. If the object is of class ‘Sub-Network’ no variant information is
required and this field should be left blank.
Object Location is an optional attribute which may be used to convey the physical
location of the object, e.g. 12th Street Office / Rack TQ1-0.

Toolbindings

Selecting Tool Binding... from the right click menu (available either from the main or
preview windows) will display the following dialogue box:

Tool bindings allow you to set the tools that can be selected from the popup menu
associated with the element when using the network browser.
The list box entitled Available Tools shows a list of the tools that are still available for use
on this particular object. Selecting one or more of the tools and then the button -> will
bind the tools to the object (shown by the selected tools moving into the Bound Tools box.
When tools are highlighted in the bound tools box then can be unbound by pressing the
<- button.
Highlighting an item in the box titled Label and pressing the Edit Label button allows you
to change the text that is displayed when the popup menu is shown.
Double Click Tool - selecting a bound tool and then clicking on the set as double click
tool button will change the currently selected double click tool. This will be shown in the
caption at the bottom of the box, marked Current Double Click Tool.

Managed Object Configuration Page 17(24)


TMSL 197-46600-01 Issue 1: Sep 99

Remove Object
You may find that you want to remove certain objects from the system. This is easily achieved by
selecting the object that you wish to delete, then either pressing the Delete key (on your keyboard),
selecting Delete from the right click popup menu, or pressing the Delete option on the main toolbar.

Edit Object

Edit Object Attributes

Should you wish to edit the attributes of an object in the system, all you have to do is select
the object with the right mouse button and choose the ‘Attributes...’ item from the right
click menu. A dialogue appropriate for the object will then be displayed (see the Section:
Attributes for Managed Elements, starting on page 11.)
You are able to edit the attributes for an object in either the main or preview windows.

Edit Object Name

It is possible to edit the name of an object in the system without having to go through the
object attributes dialogue. By selecting Edit Distinguished Name from the right click
popup menu or selecting the item text using the left mouse button, it is possible to edit the
text in place.

Move Object

Moving objects from one location in the system to another is an easy task. First ensure
that you are at the main window and not in the preview window. Then select the object

Page 18(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

that you want to move with the left mouse button, then with the left button still depressed
‘drag’ the object to its new location.
You will then be presented with a message box asking you to confirm the operation. If
you are happy with the move select OK, otherwise choose Cancel.

Copy Object

Copying an object allows you to make an exact duplicate of an object and place it
anywhere in the system. Changes made to either object will not be reflected in the other.
When an object is initially copied, the Distinguished Name is prefixed with the words
“copy_of”. This can be changed once the copy is complete. See the section entitled Edit
Object (starting on page 18) for details of how to accomplish this.
To copy an object follow the following steps:

1 Select the object that you wish to copy

2 Choose the Copy option from the menu or toolbar

3 Select the location to copy to (must be a sub-network)

4 Choose the Paste option from the menu or toolbar

5 Confirm the operation by pressing OK on the dialogue box that is


displayed

Link Object

Linking allows one object to be contained in two or more places in the system, i.e. any
changes made to the object will appear in all of the linked objects.
To copy an object follow the following steps:

1. Select the object that you wish to copy

2. Choose the Copy option from the menu or toolbar

3. Select the location to copy to (must be a sub-network)

4. Choose the Link option from the menu or toolbar

5. Confirm the operation by pressing OK on the dialogue box that is


displayed

Managed Object Configuration Page 19(24)


TMSL 197-46600-01 Issue 1: Sep 99

Preview Network
Managed Object Configuration provides the ability to preview and edit the contents of a sub-
network to see how it will appear in the network browser.
To enter the preview view simply select Preview from the right click menu that is displayed when
selecting a sub-network from the main window. You will be presented with a window that looks
something like this:

Change Background image

To change the background image, select the Change background image... item from the
operations menu. A bitmap file and location can then be selected via the file selection
dialogue that is provided.The window will then size itself to the new image.
Note: only bitmap images can be used for the background image.

Page 20(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Change Style

Selecting the Change Style... option from either the right click menu or the toolbar will
allow you to change how the Managed Elements are displayed in the preview window.
After selection you will be presented with the following dialogue

Simply choose the button next to the style that you want and press OK for all the icons on
the window to be changed.

Test

When this option is selected, selecting an object will allow you to test the currently
selected toolbindings. i.e. selecting an object with the right mouse button will produce a
popup menu with the available tools.

Save

When a change has been made to the preview the Save option will become active.
Selecting the Save option will save all of the changes that have been made.

Managed Object Configuration Page 21(24)


TMSL 197-46600-01 Issue 1: Sep 99

Using Imported Graphics In A Client / Server Setup

The Managed Object Configuration application will only look for the graphics files using
the path that is given when the image is selected. This can cause a problem when trying
to preview an object on a client when its attributes have been set on the server. This is
because the path given (e.g. c:\Net-Monitor\Graphics\Icons) may not exist on the client
machine. However, when the network that has been set up is used with the Network
Browser this problem does not exist.
If the Browser is unable to load the images from the specified directory the Browser will
then look in another directory that is made up from a combination of the original path and
the GRAPHICS_LOCATION environment variable. Anything before the “\Graphics”
part of the path is removed and is then replaced with the path set by the
GRAPHICS_LOCATION variable.

Page 22(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Chapter Index

Alarm Audit ............................................................................................................................... 14


-On Heartbeat Restoration .................................................................................. 14
Attributes ..................................................................................................................................... 11

Background Image ................................................................................................................... 15


Backup CM Address .............................................................................................................. 13
Backup Configuration Management Address: see Backup CM Address
Backup Transport ................................................................................................................... 13
Bitmap Image ........................................................................................................................... 10

Contained Objects .................................................................................................................. 21


Container Objects ..................................................................................................................... 4

Elements (ME & NM)................................................................................................................. 6

Fault Management Address ........................................................................................... 12, 13

Heartbeat:
-Interval ...................................................................................................................... 14
-Surveillance ............................................................................................................ 14

Graphics, In Client / Server Setup ...................................................................................... 22

Managed Element ...................................................................................................................... 4


-Attibutes for ..............................................................................................................11
Managed Object Configuration
-Database ................................................................................................................... 3
-Database Window .................................................................................................. 7
-Tool .............................................................................................................................. 3

Managed Object Configuration Page 23(24)


TMSL 197-46600-01 Issue 1: Sep 99

ME’s ............................................................................................................................................... 4
Monitor Administrator Group................................................................................................. 3

Network Browser Application .............................................................................................. 15

Object Location .............................................................................................................11, 15, 17


Object Type ...................................................................................................................11, 15, 16
Object Version ....................................................................................................................11, 17

Password ................................................................................................................................... 12
Prime
Configuration Management Address ............................................................... 12
Transport ..................................................................................................................... 12
Protocol ........................................................................................................................................ 12
PSTN Modem ........................................................................................................................... 12

Regions ........................................................................................................................................ 4

Source Identifier ...................................................................................................................... 12


Sub-Networks (SN) .................................................................................................................. 5

Virtual Objects ............................................................................................................................ 4

Page 24(24) Managed Object Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Security Manager

The aim of Security Manager is to keep your records and applications safe from
those who are not authorised to use them. It does this by checking that a given user
has the security privileges necessary to complete a particular action.

What would I need to use the Security Manager Application?

The Security Manager can either be run as a standalone application or as part of


a suite of NetMonitor applications. You will need a server (or database) that is
already set up to exchange information with the Security Manager in order to run it
effectively. Security Manager comes supplied with a set of templates suitable for
Users, Administrators and Observers of the NMS applications.

What’s in this chapter?

In order to make full use of the security management subsystem it is necessary for
you to understand the concepts of the security system and how they interrelate.
The ‘Notes For Administrators’ part of this chapter (page 20) outlines some key
concepts needed in order to exploit the features of the Security Manager, including
information about the supplied templates. There is a step by step guide to using
Security Manager (starting on page 5). If you need to use the chapter as a quick
reference guide, there is a keyword index starting on page 22.

Security Manager Page 1(28)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Contents
Opening the Security Manager Application ......................................................... 3
The Menu .............................................................................................................. 5
Using Security Manager- Overview ..................................................................... 5
Users Page ............................................................................................................ 7
Adding / Editing User Items ...................................................................... 7
Viewing / Modifying Access Levels Available To a User........................ 8
Making A New Resource Available To A User........................................ 9
Deleting a User.......................................................................................... 9
User Groups Page...................................................................................... 9
Adding / Editing User Groups ............................................................................ 10
Access Rights.......................................................................................... 10
Access Tree ............................................................................................. 11
User List .................................................................................................. 12
Deleting User Groups.............................................................................. 12
The Resources Page ............................................................................................ 13
Editing Existing Resources ..................................................................... 13
Adding New Resources. .......................................................................... 14
Deleting Resources .................................................................................. 14
Resource Groups Page ......................................................................................... 15
Adding a New Resource Group ............................................................... 15
Editing Existing Resource Groups ........................................................... 15
Deleting Resource Groups....................................................................... 16
Advanced Administration Page .......................................................................... 17
Type Definitions ...................................................................................... 17
Access Templates .................................................................................... 18
Automatic Idle Time Out .................................................................................... 18
Frequently Asked Questions... ............................................................................ 20
Notes for Administrators ..................................................................................... 22
Terms Used In Security Manager............................................................. 22
Supplied Templates .................................................................................. 23
Chapter Index....................................................................................................... 25

Page 2(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

Opening the Security Manager Application

The application is launched by double clicking on its icon , found on the NMS Admin menu,
in either the WindowsNT Start menu or the Unix CDE Front Panel. Once successfully launched
the application will show a list of users registered with the system (Figure 1.)

The Security Manager Application can also be started by selecting its shortcut from the program
group.

If launched from the command line, it can only take only one parameter, that for the NLS file. This
provides non-English versions of the application. This is done in the form of ‘-nls file.nls’, where
‘file’ is name of your required language NLS file.

Figure 1 The Unix CDE Front Panel / Window Start Menu

Security Manager Page 3(28)


TMSL 197-46600-01 Issue 1: Sep 99

Using the Security Manager Application

Figure 2 Security Manager at Startup

Once started successfully, the Security Manager will look similar to Figure 2. It is structured as a
series of tabbed pages. You can select any page at any time (although the current page may require
you to finish changing data before letting you leave it).
There is the usual menu bar under the title bar and three buttons at the bottom of the tool - OK,
Cancel and Apply.
The OK button sends the current security set up to the server and closes the tool.

The Cancel button closes the tool without sending data to the server.

The Apply button updates the server but does not close the tool. This is particularly useful if you
want to save changes that you have just made, but are unsure about a set of changes which you are
about to attempt.

Page 4(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

The Menu
The security configuration tool has four drop down menus -

File Menu

Import Data File: You can set up and save different security configurations without
committing them to the server and consequently having them go ‘live’. The Import Data
File option is for reloading a previously saved data set.
Export Data File: The export data file option allows you to save the current security set
up in the security tool to a data file. This option is also useful for making backups of the
security configuration over and above that provided automatically by the security system.
Exit: Selecting this closes the security tool.

Options Menu

Show / Hide Advanced Administration Tab: This option either displays or removes the
advanced administration page from the security tool. This feature is intended to ensure
that settings on the advanced administration page are only modified intentionally, as they
could have a severe impact on the rest of the security system.

Window Menu

Refresh from server:- Selecting this item will update the security tool’s local copy of the
security data from the server and refresh the window. Any changes which have been made
in this session but not yet saved to the server (using the Apply button) will be lost. A
warning to this effect will be issued before the refresh is begun.

Help Menu

Contents: The contents item brings up the help contents page


About: Selecting this item displays the security tool’s About box, which shows version
and copyright information.

Using Security Manager- Overview


There are five tab pages in all (one is hidden initially). The first four all look similar and work in
the same way. They show a list of items with the information arranged as a series of columns,
containing items. First we will examine actions which are common to all the pages in Security
Manager, then we will move on to examine the contents of each page in detail. Item is a general
term, meaning an entry or row in the list on any of the tab pages.

Security Manager Page 5(28)


TMSL 197-46600-01 Issue 1: Sep 99

Sorting Security Manager Items

Clicking on each column heading will sort the list based on the data in that column.
Clicking the same column twice will reverse the order in which the data is sorted.

Editing Items in Security Manager

To edit any item in the list double click on it in the left hand column and an appropriate
details dialogue box will be displayed. This dialogue can also be produced by right
clicking on the item and selecting the Details.. option from the popup menu.

Adding Items to Security Manager

To add a new object click the Add button which will be under the list, or right click in a
blank area of the list and select Add... from the popup menu. This will create a new object
with a default name and bring up the appropriate details dialogue to allow you to edit the
newly created object. Note that the name of an object is required and must be unique.

Deleting Items from Security Manager

Deleting an object requires selecting the object in the list and clicking the Delete... button
at the bottom of the page, or right clicking the appropriate object and selecting Delete...
from the popup menu. There is a confirmation dialogue before objects are deleted as this
action cannot be undone.
Note: You cannot delete a User Group / Resource Group which still contains a User /
Resource.

Filtering Items in Security Manager

Many of the dialogue boxes contain filter boxes. These are intended to assist you by
decreasing the size of lists which may contain many items. The first item in the filter box
will be All, which displays all of the data, followed by the options that limit the data.
These filters only affect the display - they do not change the underlying data or security
set up.

Page 6(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

The five tab pages will now be examined in detail:

Users Page
The users page is the active page when the application first starts (see Figure 2 on page 4).
The page consists of four columns.

User Name Column

The first of these columns is the user’s login name. This must be the same as the name
with which they identify themselves to the operating system at login time.

Full Name Column

This shows the real name of the user. This is particularly useful if their login is something
meaningless, such as fb27.

User Group Column

The next column shows the user group to which the user currently belongs. Users can only
belong to one group at a time.

Modified? Column

The final column indicates whether the user has any specific overrides in their security
access.

Adding / Editing User Items

Double clicking on item in the user name column will bring up the user details dialogue
box. This allows you to change the user’s login, full name and user group (See “Using
Security Manager- Overview” on page 5.)

To add a new user, either right click on and empty part of the list and select Add from the
popup menu, or click the Add User button at the bottom of the window. An empty version
of the User Details dialogue box will be displayed which you can fill in.

Note: You will need to have created a User Group before you can add a User.

Security Manager Page 7(28)


TMSL 197-46600-01 Issue 1: Sep 99

Figure 3 The User Details Dialogue Box.

Viewing / Modifying Access Levels Available To a User

The resources to which a user has access are also listed in the user details dialogue box
(Figure 3). Expanding a resource, by either double clicking on its name or single clicking
on the small + box to its left, will show all of that resource’s attributes. The user’s default
access level for each attribute will be marked in brackets, e.g. (NA-No Access, as shown
next to Application Y in Figure 3 on page 8.) This default access is inherited from the
User Group to which they belong.

If you wish to override the user’s access level to that attribute you can add a modification
to the security level. Right clicking on the attribute will bring up the popup modifications
menu. The first item (Add modification) cascades into a further menu that lists access
levels. Selecting an access level from this menu will set the modification. Once set, a
modification is shown to the right of the original access in angle brackets, e.g. <FA>,
shown on Application Y in Figure 3.

Removing a modification is just as simple. Right click on an attribute with a modification


and select Remove Modification from the menu.

Page 8(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

Click OK to set the changes, or Cancel to return to the main window without applying
them.

Making A New Resource Available To A User

Resources cannot be added directly to the user. If you need a user to have access to a
resource which is currently unavailable to them, take the following steps:
• find out which resource groups the user’s user group can access
• add the resource to one of these resource groups
• set the default access level to that resource to NA -No Access.
• modify the individual user’s Access Level to this resource as outlined
in the previous section
If this is not desirable, you could consider moving them to a group which does have access
to the required resource.

Deleting a User

To delete a user, highlight their name in the list and press the Delete User button at the
bottom of the window. You could also select Delete from the popup menu.
If you wish to commit these changes to the server immediately click Apply at the bottom of the
main window.

User Groups Page

Figure 4 The User Groups Page

Security Manager Page 9(28)


TMSL 197-46600-01 Issue 1: Sep 99

The user group page is shown in Figure 4. There is a column displaying the names of the user
groups, and a column displaying an optional description of each user group.

Adding / Editing User Groups

Double click on an item in the User Group column to bring up the user group details
dialogue box for the selected group. Pressing the Add Group button also brings up the
User Group Details dialogue, but in this case it is empty.

The dialogue (Figure 5) consists of several tabs, each discussed in detail below.

Figure 5 The User Group Details Dialogue

Access Rights

This tab is displayed when the dialogue opens. It is divided into two halves. The top half
has the details of the user group. These are the name, and an optional description or
comment about the group. The bottom half of the page is where you set up which
resources can be accessed by members of the group.

Page 10(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

The Resource Groups box shows a list of the resource groups currently selected into this
user group. Clicking the Import Resource Groups button or double clicking the
Resource Groups box will bring up the Import Resource Groups dialogue box.

Figure 6 The Import Resource Groups Dialogue Box

In this box you can select which resource groups are included by ticking the check box
next to the group’s name. You can deselect resources by clearing the check box. Once you
have the appropriate resource groups selected into the user group, you can set the access
levels for the resources contained in them. Click OK to use this resource configuration,
or Cancel to retain the existing resource set. Either button will return to the User Groups
Details dialogue (Figure 5 on page 10).

Selecting a resource group in the list displays all of its resources in the Resources box
and the Access Templates box shows all the available access templates. Selecting an
access template by ticking its check box will apply that access template to all the resources
in the selected resource group. Multiple access templates may be selected for any given
resource group. Where access levels conflict, the higher access level will be applied.

There is also a filter box, marked Display Objects of Type which allows you to limit the
resources and access templates displayed to a specific type only.

Access Tree

Click in the tab marked Access Tree to move to that page. This shows all the resources
that can be accessed by this user group. Clicking in the + box to the left of each resource
will expand it, showing attributes and sub attributes.

To the left of each attribute, its default access level is shown in round brackets. This access
level is derived from the access templates selected into the group. If you wish to add an
override to an access level it can be done on this page by right clicking on the appropriate
attribute and selecting Add Modification. Then select the access level you want from the
resulting menu.

Security Manager Page 11(28)


TMSL 197-46600-01 Issue 1: Sep 99

Removing the override is done similarly by selecting Remove Modification from the
right click menu.

To change to default access level that a user group has to a given resource, you will need
to change the access template that is applied to that resource using the Advanced
Administration Page, Figure 11 on page 17.

User List

The user list page simply shows which users are part of this group.

Deleting User Groups

To delete a resource group, select it in the main Resource Group Window and press the
Delete Group button at the bottom of the page.
Note: You cannot delete a User Group that still contains Users. Reassign Users to another
User Group before deleting the User Group.

If you wish to commit these changes to the server immediately click Apply at the bottom of the
main window.

Page 12(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

The Resources Page

Figure 7 The Resources Page

The resource page shows all the resources that are in the system. There are two columns showing
the name and the type of the resource. Above the list of resources is a filter that allows you to select
the type of resources that you wish to view. In Figure 7, only resources of the type Application are
shown.

Editing Existing Resources

Double clicking / right clicking on the name of a resource will bring up the resource
details dialogue, which is similar to that shown in Figure 8 on page 14.

This shows you the name and type of the resource. Both of these can be edited. The
facility of changing the type is provided in case the wrong type is initially selected, but
should be used with care.

Click OK to return to the main resource page, saving the changes, or Cancel to abandon
them.

Security Manager Page 13(28)


TMSL 197-46600-01 Issue 1: Sep 99

Adding New Resources

In the main Resource Page, click on the Add Resource button at the bottom of the page,
or right click on an empty part of the page, and select Add from the popup menu. This
will bring up an empty resource dialogue details box.

Figure 8 The Resource Details dialogue

This box allows you to set the name of a new resource, and to select the type of the
resource from a drop down list that contains all the existing type definitions.

Note: a type must have been previously defined before a resource of that sort can be
added. New types of resources are added in the Advanced Administration page, page 17.

Click OK to keep the newly defined resource, or Cancel to return to the main resource
page without saving the changes.

Deleting Resources

To delete an existing resource, highlight it in the main resources dialogue page (Figure 7)
and press the Delete Resource button at the bottom of the page. This will bring up a
confirmation box, checking that you really want to lose this resource.
If you wish to commit these changes to the server immediately click Apply at the bottom of the main
window.

Page 14(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

Resource Groups Page

Figure 9 Resource Groups Page

The resource groups page shows all the resource groups in the system. It has two columns showing
the name of the resource group and an optional description. Adding, deleting and editing of resource
groups is done in the usual way.

Adding a New Resource Group

Either right click on an empty part of the page or click the Add Resource Group button
at the bottom of the page. Both of these actions will bring up the Resource Group details
dialogue. Fill this in with the Resource Group name (required) and Resource Group
description (optional), then follow the instructions for adding resources to a group in
Editing Existing Resource Groups, below.

Editing Existing Resource Groups

Double clicking / right clicking on a Resource Group will bring up the Resource Group
details dialogue.

Note: The Resource Group called System is maintained automatically and cannot be
modified by you. This group contains all the resources currently administered by the
Security Manager application. Providing every user group with differing levels of access
to this group (for example, access to Managed Elements) ensure that any new Managed
Elements added will automatically be available to that user group.

Security Manager Page 15(28)


TMSL 197-46600-01 Issue 1: Sep 99

Figure 10 The Resource Group Details dialogue box

The resource group details dialogue box allows the name of the group to be changed, and
an optional description to be added or edited. It also allows you to edit the resources that
are in the group.
To add a resource, select the one you want to include from the box on the left labelled
System Resources and click the Add >> button. At this point it will transfer across to
the Resources In This Group box.

Resources can be removed from the group by selecting them in the right hand box and
clicking the << Remove button.

The Resources Filter box can be used to limit which resources will be displayed in both
of the boxes.

Deleting Resource Groups

To delete a resource group simply highlight it in the main Resource Group page and press
the Delete Resource Group button at the bottom of the page. A confirmation dialogue
will be displayed, checking that you really want to do this.

Note: You cannot delete Resource Groups that still contain Resources. Reassign
Resources to another Resource Group before deleting a Resource Group.

Page 16(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

If you wish to commit these changes to the server immediately click Apply at the bottom of the
main window.

Advanced Administration Page

Figure 11 The Advanced Administration Page

The Advanced Administration Tab is different from the rest of the tabs because it does not display
a list of items. Instead it displays two trees. All operations are performed using right click menus.
The tab for the advanced administration page is not visible by default. In order to display this tab
you need to go to the options menu and select Show Advanced tab item. The tab will now become
visible to the right of the other tabs. The two trees on this page allow configuration of type
definitions and access templates.

For a fuller discussion of Type Definitions and Access Templates see Notes for Administrators,
page 20.

Type Definitions

Viewing Type Definitions

The types tree (on the left of the page) lists all the types that are defined in the
security system. Double clicking on the name of a definition, or clicking the
+ box to the left of it (if present), will expand that type definition to show any
attributes that it may have.

Security Manager Page 17(28)


TMSL 197-46600-01 Issue 1: Sep 99

Adding a Type Definition

To do this, right click on the top of the tree, named Defined Types. This will
bring up a menu with Add Type Definition on it. Selecting this will create a
new type.

Adding / Renaming / Deleting Attributes In A Type Definition

Right clicking on a type brings up a menu with Add Attribute, Rename and
Delete options. The add attribute option creates a new attribute under the
type. New attributes can be created under the type and under other attributes.
There is no limit to how deeply attributes can be nested.

Access Templates

The access templates tree (on the right of the page) is only active when a type definition
is selected in the left hand pane of the page. When a type definition is selected the existing
access templates based on that type will be displayed. Access templates are managed in a
similar way to type definitions.

To show all of the attributes in an access template, expand it by clicking the + box to the
left of the item. Each attribute has an individual access level.
Adding New Access Templates

Right clicking on the root tree item brings up a menu allowing the option to
create a new access template. You will notice that once an access template is
created it will always have the same set of attributes as its associated type -
even if the type is subsequently modified. Changes are automatically
propagated to all templates derived from the modified type. When an access
template is created all of its attributes are set to full access by default.

Editing Access Templates

To change the access level right click on an attribute and select the new access
level from the menu. Notice that in the case of cascaded attributes each
attribute has its own access level.

Deleting Access Templates

To delete an Access Template, right click it and select Delete from the popup
menu.

Automatic Idle Time Out


Only one copy of the security tool can be open at any one time. As the server to which the tool
connects may be running on a different machine from that of the tool, it is possible that the security
tool could inadvertently be left running and prevent other copies being started.

Page 18(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

To avoid this, the security tool detects when it has been left idle for five minutes and prepares to
close down automatically. Thirty seconds before closing down, Security Manager beeps and
displays a dialogue. This informs the user that it is about to terminate and that changes will not
automatically be saved, and counts down the remaining seconds. To stop the application from
shutting down, press the cancel button on the dialogue box.

Security Manager Page 19(28)


TMSL 197-46600-01 Issue 1: Sep 99

Frequently Asked Questions...

1 Q. Why can’t I change the System Resource Group?


A. This is not modifiable by the user. It shows all the resources which are currently
being managed by the application. When resources are removed from or added
to Security Manager, the System resource group is automatically updated.

2 Q. Why can’t I add a new resource type in the Resource Details


dialogue box?
A. You need to predefine your resource type first in the Advanced Administration
page, before you can add a resource of its type to Security Manager.

3 Q. Why do only some of my changes get saved?


A. To ensure that a modification is saved, press the Apply button once you have
completed it. Then the server will be updated with any unsaved changes.

4 Q. Why can’t I change the name of an attribute in the Access


Templates?
A. Access Templates (on the Advanced Administration page) always follow the
Type Definitions. To change the name of the attribute, you will need to change
it in the Type Definition. The change will then propagate to all Access Templates
derived from it.

5 Q. I’ve just started Security Manager, and can’t add my first user.
Why not?
A. You need to define a user group before you can add any users to Security
Manager.

6 Q. Can I select more than one user / resource at a time?


A. No.

7 Q. Why can’t I delete a User Group / Resource Group?


A. You cannot delete a User Group or Resource Group which still has members.
Reassign these members to another group before attempting to remove the
original group.

Page 20(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

8 Q. Why can’t I start a copy of Security Manager?


A. Only one copy of Security Manager can be running at a time. Check that either
the home machine, or the server to which it connects, is not already running a
copy of Security Manager.

Security Manager Page 21(28)


TMSL 197-46600-01 Issue 1: Sep 99

Notes for Administrators

Terms Used In Security Manager

User

A user is a person registered with the security system. Their security access
is derived from the user group to which they belong.

User Group

User groups are sets of individual users who have the same or similar access
privileges. It is in a user group that most of the security access is set up. A
user group contains a set of resource groups that specify which resources the
user group members can access, and you can assign a set of access templates
to act on each resource group.

Resource

A resource represents something that is secured. Resources have to be based


on a type definition (page 20) and they inherit the attribute structure (page 21)
of that type. If the definition subsequently changes so does the structure of all
resources based on that type.

Resource Group

A resource group is simply a collection of resources. There is always one


resource group defined, called System. This contains all resources currently
supervised by the Security Manager. You can define as many resource groups
as you wish. Resource groups may contain as many resources as necessary.
Each resource can be included in more than one resource group. One example
of a resource group could be to class resources by their geographical location.

Type Definition

A type is intended to model something that can be secured. Types are used as
templates on which to base resources. They can have a set of attributes (page
21), each of which can be assigned an access level (page 21). Attributes can
also contain attributes, so for example you could have MRC1 as an attribute
with ports 1 to 4 as sub attributes.
Another example of a type definition would be to have a type called
Application with an attribute Run which would be used to specify who could
launch that application.

Access Templates

An access template provides a way of specifying a set of access levels for a


type. For any given type you can define as many access templates as

Page 22(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

necessary. Each access template can assign a different access level to each
attribute. Access templates can be applied to all the resources in a resource
group via a user group.

Attribute

An attribute is a specific part of, or action that can be performed on, a


resource. Each attribute has an individual access level. Attributes are created
in type definitions.

Access Levels

These are levels of access that a user has to a resource, or to one of its
attributes. There are three access levels: No Access (NA), Read access (R) and
Full Access (FA).

Modifications

The security system is designed to allow you to set up the likeliest access
scenario for most situations quickly and easily. However in some
circumstances you may want to tweak the specific access provided for a given
user or user group. These tweaks are known as modifications and can be
applied on a per attribute basis to both individual users and user groups.

Supplied Templates

The Security Manager comes with a ready to use set of templates already defined for you,
providing you with instant security for the NMS set of applications. They contain the
following groupings:
Resource Group

There are two designated Resource Groups:

• System- all of the resources controlled by Security


Manager.
• User Resource Group- the resources which can
be accessed by Users.
User Group

There are three designated User Groups with default access levels:

• NMS Admin- Full access to all resources in


System, and hence all of the resources in the User
Resource Group.
• NMS Users- Full access to all resources in the User
Resource Group, and full access to all SubNetwork and
Managed Element (ME) resources. Note that this group

Security Manager Page 23(28)


TMSL 197-46600-01 Issue 1: Sep 99

also has limited access to the System group, so that any


Managed Elements or SubNetworks which are added
to Security Manager control.
• NMS Observers- Read access to all resources in the
User Resource Group.
Users

There is one designated User:

• nms- A member of the NMS Admin group.

Page 24(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

Chapter Index

Access Level
-Changing Default .................................................................................................. 12
Access Level
-Default ........................................................................................................................ 8
-Default For User Group .......................................................................................11
-Modifying For User Group ..................................................................................11
-Removing Modification from User ..................................................................... 8
Access Rights .......................................................................................................................... 10
Access Templates ............................................................................................................ 11, 18
-Adding ...................................................................................................................... 18
-Default Attribute Setting ..................................................................................... 18
-Defined ..................................................................................................................... 23
-Deleting .................................................................................................................... 18
-Displaying for Type Definition .......................................................................... 18
-Editing ....................................................................................................................... 18
-For User Groups ....................................................................................................11
Access Tree .............................................................................................................................. 11
Advanced Administration Page .......................................................................................... 17
Advanced Page
-Show ......................................................................................................................... 17
Apply Button ............................................................................................................................... 4
Attribute
-Access Levels ........................................................................................................ 18
-Defined ..................................................................................................................... 23
-Renaming ................................................................................................................ 18
Attributes
-Adding ...................................................................................................................... 18

Button
-Apply ........................................................................................................................... 4
-Cancel ........................................................................................................................ 4
-OK ................................................................................................................................ 4

Cancel ......................................................................................................................................... 13
Cancel button ............................................................................................................................. 4

Defined Types .......................................................................................................................... 17


Deleting ........................................................................................................................................ 6

Security Manager Page 25(28)


TMSL 197-46600-01 Issue 1: Sep 99

Editing ........................................................................................................................................... 6

File Menu ..................................................................................................................................... 5


Filtering Items ............................................................................................................................. 6
Full Name .................................................................................................................................... 7

Help Menu ................................................................................................................................... 5

Idle Time Out ............................................................................................................................ 18


Import Resource Groups Dialogue Box .......................................................................... 11

Menu
-File ............................................................................................................................... 5
-Help ............................................................................................................................. 5
-Options ....................................................................................................................... 5
-Window ....................................................................................................................... 5
Modification
-Defined ..................................................................................................................... 23
Modified ........................................................................................................................................ 7

Notes for Administrators ....................................................................................................... 22

OK Button .................................................................................................................................... 4
Options Menu ............................................................................................................................. 5

Page
-Advanced Administration ................................................................................... 17
-Resource Groups ................................................................................................. 15
-Resources ............................................................................................................... 13
-User Groups ............................................................................................................. 9
-Users ........................................................................................................................... 7

Page 26(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

Resource
-Adding to User ........................................................................................................... 9
-Defined ..................................................................................................................... 22
-Expanding ................................................................................................................. 8
Resource Details Dialogue Box ......................................................................................... 14
Resource Group
-Adding ...................................................................................................................... 15
-Defined ..................................................................................................................... 22
-Editing ....................................................................................................................... 15
-System ...................................................................................................................... 15
Resource Group Details Dialogue Box ........................................................................... 16
Resource Groups
-Deleting .................................................................................................................... 16
-Modifying for User Group ....................................................................................11
Resource Groups Page ........................................................................................................ 15
Resources
-Adding ...................................................................................................................... 14
-Deleting .................................................................................................................... 14
-Editing ....................................................................................................................... 13
-Viewing For User Group ......................................................................................11
Resources Page ...................................................................................................................... 13

Security Manager Icon ............................................................................................................ 3


Security Manager Items
-Adding ........................................................................................................................ 6
-Sorting ........................................................................................................................ 6
Starting Security Manager ..................................................................................................... 3
Supplied Templates ............................................................................................................... 23
System Resource Group ...................................................................................................... 15

Templates
-Supplied ................................................................................................................... 23
Time Out .................................................................................................................................... 18
Type Definition
-Defined ..................................................................................................................... 22
Type Definitions
-Adding ...................................................................................................................... 18
-Adding Attributes .................................................................................................. 18
-Expanding ............................................................................................................... 17
-Viewing ..................................................................................................................... 17

Security Manager Page 27(28)


TMSL 197-46600-01 Issue 1: Sep 99

User
-Adding ........................................................................................................................ 7
-Defined ..................................................................................................................... 22
-Deleting ...................................................................................................................... 9
-Details Dialogue Box ............................................................................................. 8
-Editing ......................................................................................................................... 7
-Modifying Access Levels ...................................................................................... 8
User Group ................................................................................................................................. 7
-Access Rights ........................................................................................................ 10
-Adding ...................................................................................................................... 10
-Details Dialogue .................................................................................................... 10
-Editing ....................................................................................................................... 10
-User List ................................................................................................................... 12
User group
-Defined ..................................................................................................................... 22
User Groups
-Deleting .................................................................................................................... 12
User Groups Page .................................................................................................................... 9
User List, for User Group ..................................................................................................... 12
User Name .................................................................................................................................. 7
Users Page ................................................................................................................................. 7

Window Menu ............................................................................................................... 5

Page 28(28) Security Manager


Issue 1: Sep 99 TMSL 197-46600-01

Configuration
Manager

The Configuration Manager is an application which is part of the TimeScan suite of


applications. It will provide you with a real-time picture of the internal state of a DCD
and simple point and click controls to configure the DCD.

Why would I need to use the Configuration Manager?

The Configuration Manager is useful if you need to quickly see exactly how the
DCD is managing the synchronisation signals. You can use it to configure all the
signal processing functionality of the DCD without typing a single TL1 command.

What’s in this Chapter?

This chapter contains all the information you need to know to fully exploit the
potential of the Configuration Manager. The “Configuration Manager Tour” (page
3), provides a quick description of the features and facilities of the Configuration
Manager. The “How To..” section (page 25) explains how to configure the facilities
of the DCD.

There is a section with specific instructions for the TimeSource 3000 element (page
21).

If you need to use the chapter as a quick reference guide, there is an index at the
end (page 55).

If you have any queries regarding the Configuration Manager try the Frequently
Asked Question section (page 54).

Configuration Manager Page 1(62)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Contents
Opening the Configuration Manager .............................................. 3
Configuration Manager Tour ........................................................... 3
The Menu Bar ........................................................................3

The Status Bar .......................................................................4


The Overview Page ........................................................................... 5
Interpreting the Overview .......................................................6

Synchronisation Reference Input Ports ....................................7

Input Reference Modules ....................................................... 9

Clock Modules (CLKs) ........................................................ 11

Timing Output Array (TO Array) ..........................................11

DCD Internal Signal Distribution .......................................... 12


Configuring the DCD from the Overview ................................... 13
The Shelf Pages ............................................................................... 16
Output Protection .................................................................18

Removed (Disabled) Modules ...............................................19

Missing Modules .................................................................19


Configuring the DCD from the Shelf Pages ................................ 20
TimeSource 3000 ............................................................................ 21
The Overview Page ..............................................................21

Interpreting The Overview ...................................................22

The Shelf Page ....................................................................22

Configuring the TimeSource 3000 From The Shelf Page ........ 23

The TimeSource 3000 Menus ...............................................24


How To ............................................................................................. 25
Frequently Asked Questions........................................................... 54
Chapter Index ................................................................................... 55

Page 2(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Opening the Configuration Manager


The Configuration Manager is launched either from the TimeScan/Craft ToolPalette or by double
clicking on an icon in the Network Browser.

Configuration Manager Tour


The first thing to notice about the Configuration Manager is that it provides a number of tabbed note
book pages. In later sections of this tour we will look at each page in detail. First we will look at
functions which are common to each page.

The Menu Bar

Configuration Manager supports a number of useful facilities accessed from the Menu
Bar at the top of the window.
Window Menu

The Window Menu provides a list of the standard facilities: Print, Print
Preview and Print Setup which allow you to configure and review hardcopy
generated by Configuration Manager. Exit will terminate this session of
Configuration Manager use.

Options

As we shall see later, you can use Configuration Manager to configure the
DCD. By default, every time you request a configuration change,
Configuration Manager will require you to provide confirmation. This
behaviour can be turned off by removing the Confirm tick in this menu.
Conversely it can be turned on by re-checking Confirm.

Help

This menu provides access to an about box containing author and version
number information for Configuration Manager.

Configuration Manager Page 3(62)


TMSL 197-46600-01 Issue 1: Sep 99

The Status Bar

Towards the bottom left hand corner of the main window is a panel known as the Status
Bar

Figure 1 Configuration Manager Status Bar

The Status Bar provides an insight into the operation of the Configuration Manager.
On start up, the Configuration Manager must perform a range of tasks in order to
determine the correct configuration and status of the DCD. The following paragraphs give
the sequence and meaning of the Status Bar messages produced at start-up:
Attempting to connect to [DCD distinguished name]
The Configuration Manager is attempting to establish a connection. This step will
normally take a fraction of a second. On connection the status will change to:
Connected to [DCD distinguished name]
Once connected Configuration Manager will start to collect the information it requires to
correctly depict the state of the DCD and the status will change to:
Fetching initial data
This phase normally takes a few seconds and is dependent on the number of shelves and
equipment modules that compose the DCD. Once the DCD state is determined the status
will again change to:
Ready
This is the idle state of the Configuration Manager. In this state the communication path
towards the DCD is functioning correctly and the status information currently displayed
is correct. Configuration Manager is ready to accept any operator actions.
We shall see later in this chapter that it is possible to use the Configuration Manager to
set the configuration of the DCD. When a change in configuration is requested the status
is set to:
Sending command
This indicates that the Configuration Manager is busy performing the action you have
requested and will not accept another.

Page 4(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

The Overview Page


Let’s look at the first page of the tabbed set of pages.

Figure 2 The Overview Page

This page depicts the current synchronisation status of the DCD. The structure of the page has been
purposely designed to instantly convey a great deal of information in a readily understandable
format. The following paragraphs provide an in-depth description of this page.

Configuration Manager Page 5(62)


TMSL 197-46600-01 Issue 1: Sep 99

Interpreting the Overview


The main structure of the graphic is based upon the conceptual skeleton of the DCD:

Figure 3 Conceptual Diagram Of A DCD (Digital Clock Device)

Let’s examine the graphics in more detail. We will start with the synchronisation signal reference
input ports, shown to the left and work through the DCD architecture to the timing (TO) output
ports, shown to the right.
Each DCD is capable of incorporating two Multi-Reference Controllers, (MRC 1 & 2), each with
up to four external signal reference input ports. Each input port is depicted as a pipe along which a
signal can flow to the respective reference controller functional block. The MRCs feed signals to
two Clock Oscillator Modules (CLK 1 & 2) and directly to an array of synchronisation timing signal
output ports (TO array).
The CLK modules are depicted as function blocks capable of accepting signals from either of the
MRCs, and feeding signals to the TO array. At this point in the diagram, the quadruple timing
source protection is quite apparent.
The TO array, although depicted as a single functional block, actually represents all the timing
signal output ports supported by the DCD within the Master and any Expansion shelves. There are
potentially too many output ports to be depicted individually, hence the existence of many ports is
implied.
Once the basic skeleton is understood, interpreting this page becomes much easier. As you can see,
normally the skeleton is augmented with a range of graphics conveying information on signals,

Page 6(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

activity and equipment states, etc. The following sections will look at the areas we have just
examined in some depth, and explain the significance of each graphic.

Synchronisation Reference Input Ports

As mentioned earlier each DCD may support up to eight reference signal input ports, up
to four per MRC. The status of each port can be broken down into several components as
illustrated below:

Port Number Reference Signal Selection Priority

Multi
Reference
Controller

Source Type Input Port

Figure 4 Input Port (detail)

Let’s look at each component:


Input Port

Each input port is depicted as a pipe feeding a reference signal into its Multi
Reference Controller. There are several states associated with input ports:

Active - The input port is currently selected to provide the reference signal to
its MRC.

An active input port is shown as a light blue pipe:

Stand-by - The input port is not currently selected to provide the reference
signal to its MRC.

A stand-by input port is shown as a light grey pipe:

Removed - The input port has been conceptually removed. The port still exists
but it has been temporarily removed from the pool of ports from which the
MRC may select its reference. The port is effectively barred.

Configuration Manager Page 7(62)


TMSL 197-46600-01 Issue 1: Sep 99

An input port in this state is shown as a light grey pipe with a barring symbol:

Deleted - The input port has been conceptually deleted. The port still exists
but it has been deleted from the pool of ports from which the MRC may select
its reference.

An input port in this state is shown as a silhouette:

Port Number

Each reference input port has a Port Number associated with it for ease of
identification. Port numbering is relative to the host MRC card.

For example, the correct identity of the port drawn at the top of the Overview
Page (Figure 2 on page 5) is:
Port 1 - MRC1.

Source Type

Each reference input port has a Source attribute associated with it. This
attribute defines the source of the reference signal applied to the port. The
possible source types are:

• Network
• GPS
• LORAN
• Caesium

Reference Signal

Each Reference Signal is depicted as a wave form appropriate to the current


state of the signal. There are several states associated with reference signals:

Digital Signal Present and Satisfactory - There is currently a digital


reference signal available at this input port. The signal itself is deemed to be
a valid synchronisation reference as it has not violated any of the performance
thresholds currently set on this port.

A digital reference signal in this state is shown as train of green square waves:

Page 8(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Analogue Signal Present and Satisfactory - There is currently an analogue


reference signal available at this input port. The signal itself is deemed to be
a valid synchronisation reference as it has not violated the Fractional
Frequency performance threshold currently set on this port.

An analogue reference signal in this state is shown as train of green sinusoidal


waves:

Digital Signal Present but Thresholds Violated - There is currently a digital


reference signal available at this input port. The signal itself is deemed to be
an unsuitable synchronisation reference as it may have violated one or more
of the performance thresholds currently set on this port, (Alarm Indication
Signal, Cyclic Redundancy Check, Out Of Frame, Bi-polar Violation or
Fractional Frequency).
A digital reference signal in this state is shown as train of red square waves:

Analogue Signal Present but Thresholds Violated - There is currently an


analogue reference signal available at this input port. The signal itself is
deemed to be an unsuitable synchronisation reference as it may have violated
the Fractional Frequency performance threshold currently set on this port.

An analogue reference signal in this state is shown as train of red sinusoidal


waves:

No Signal Present - There is currently no reference signal available at this


input port. A reference signal in this state is shown as flat red line:

Input Reference Modules

The DCD supports a range of Input Reference Modules. In general all such modules fall
into two groups: Clock Input (CI) (single input) modules and Multi Reference Controllers
(MRC) (up to four inputs).

For the purposes of this document we will concentrate on MRCs. The functionality of CIs
may be considered a subset of that of MRCs.

Configuration Manager Page 9(62)


TMSL 197-46600-01 Issue 1: Sep 99

The DCD is normally equipped with two Input Reference Modules, illustrated on the
graphic as two panels. For an MRC the panel is fed by four reference input ports. For a CI
or ACI the panel is fed by a single reference input port.

There are several states associated with Input Reference Controllers:

Active - The module is currently selected to provide the reference signal to the Clock
Modules or directly to the Timing Outputs.

An active module is shown as a light blue panel:

Stand-by - The module is not currently selected to provide the reference signal to the
Clock Modules or directly to the Timing Outputs.

A module in stand-by mode is shown as a light grey panel:

Not Equipped - The module is not physically present or has not been entered into the DCD

Page 10(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

inventory. A not equipped module is shown as a transparent panel with an illustration


showing module removal:

Clock Modules (CLKs)

The DCD is normally equipped with two Clock Modules each fed from the MRC Modules.
The clocks are illustrated as two panels to the right of the MRCs. There are several states
associated with Clock Modules:

Active - The Clock Module is currently selected to provide the reference signal directly to
the Timing Outputs. An active Clock Module is shown as a light blue panel.

Stand-by - The Clock Module is not currently selected to provide the reference signal to
the Timing Outputs. A Clock Module in stand-by mode is shown as a light grey panel.

Not Available - The Clock Module is not physically present or has not been entered into
the DCD inventory. A not equipped module is shown as a transparent panel with an
illustration showing module removal.

Another important attribute associated with Clock Modules is their lock state. Each
equipped Clock Module, whether active or in stand-by mode, has a small graphic of a
padlock drawn towards the top left hand corner of the module panel. This padlock
represents the lock state of Clock Module.

Clock Module locked

Clock Module unlocked (holdover, freerun or fast converge)

Timing Output Array (TO Array)

Towards the right of the graphic is a large panel labelled TO Array. This panel represents
all the Timing Outputs (TO) in the DCD including the master and any expansion shelves.
There are two states associated with the TO Array:

Active - The Timing Output Array is currently providing output timing signals. An active
Timing Output Array is shown as a light blue panel.

Configuration Manager Page 11(62)


TMSL 197-46600-01 Issue 1: Sep 99

Not Active - The Timing Output Array not is currently providing output timing signals.
An non-active Timing Output Array is shown as a light grey panel.

DCD Internal Signal Distribution

As well as depicting the state of the functional blocks, the Overview page graphic
(Figure 2 on page 5) also shows the active signal paths between the functional blocks.
Under normal conditions, and especially under fault conditions, it is important the user
can identify the active signal path through the DCD element. All the significant signal
paths between the functional blocks are shown on the user interface as grey pipes. Pipes
providing the active signal path are shaded.

Figure 5 The Active Path Through A DCD Element (shaded)

The overall effect is demonstrated in the illustration above. The active signal path is:

MRC-2 input 2 MRC-2 CLK-1 TO Array

Although input 1 of MRC-1 does not form part of the active path it is also depicted as
active. This is simply to denote that if the MRC function were to switch from MRC-2 to
MRC-1 then this input would instantly become part of the active path.
Now we have looked at interpreting the state of the DCD, we will now look at how to
configure the synchronisation functionality of the DCD from the Overview page.

Page 12(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Configuring the DCD from the Overview


As we have seen the Overview page provides a graphical presentation of the current state of the
DCD. However, it is capable of providing a means of configuring the synchronisation attributes of
the DCD.
Configuring the synchronisation functionality of the DCD could not be easier. Simply place the
mouse over the item you wish to configure and press the right mouse button! A pull-down menu
will be provided which will list all the configuration actions appropriate to that item.

Figure 6 A Typical Pull-down Menu

Menu items followed by arrows denote that there is a sub-menu.


On selecting an action from a pull-down menu a dialogue window will appear. There are two basic
types of dialogue window, Informational and Configuration Dialogue Windows.
Informational Dialogue Windows

Informational dialogues, as their name suggests, provide information only


and do not perform configuration actions.

Figure 7 A Typical Informational Dialogue Window

The title bar of an informational dialogue identifies the subject of the


information, in this case The Port State of MRC 2 port 1. The body of the
window contains short informational text messages. The window can be
closed by pressing the OK button or pressing the Return key.

Configuration Manager Page 13(62)


TMSL 197-46600-01 Issue 1: Sep 99

Configuration Dialogue Windows

Configuration dialogue windows are more complex than the informational


dialogues and provide controls to manipulate the configuration of the DCD.

Figure 8 A Typical Configuration Dialogue Window

All Configuration Dialogues follow the same generic format and provide
features designed to make configuration easier and safer.

Each configuration dialogue window is made up of an action area and five


action buttons.

In general the action area portion of the window contains fields and controls
which allow the user to read and modify the attributes which are the subject
of the configuration dialogue. There are many different types of fields and
controls.

To the right of the action area are five buttons:

Pressing the Apply button will cause modifications made to the configuration
in the action area to be applied to the DCD. The Apply button can be pressed
by selection with the mouse or with the Alt-A key combination.

As mentioned earlier the configuration mechanism has been designed to be


as safe as possible, vastly reducing the likelihood of user error. Modifying the
configuration of a DCD is not as simple as pressing the Apply button. By
default, before a configuration modification is applied to the DCD the action
must be confirmed.

Page 14(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Pressing the Apply Button from any configuration dialogue window will
generate a confirmation window similar to that shown below:

Figure 9 A Typical Confirmation Dialogue Box

If the action is mistaken then it can be cancelled by pressing the Cancel


button.

The confirmation check can be disabled by un-checking Confirm in the


Options menu, but this is not advised.

On completion of the action a dialogue will open which inform you of the
outcome of the operation. If successful, the window shown in Figure 10 will
be displayed.

Figure 10 . The Configuration Successful Window

If unsuccessful, the window message will indicate this, and also give the
nature of the action and the nature of the failure.

Once the conclusion of the action is acknowledged, access will be restored to


the configuration items temporarily barred during the operation.

Back to the description of the configuration dialogue window components...

The Cancel button provides a way to quit out of a configuration dialogue


window without modifying an attribute. On Cancelling, any un-applied
attribute values set up within the action area will be discarded. This button is
selected as default so that the window may be closed by simply pressing the
return key.

The Help button will be shown in grey, inactive, signifying that this facility
is not available in this release.

Configuration Manager Page 15(62)


TMSL 197-46600-01 Issue 1: Sep 99

The Default button provides access to recommended default attribute values.


On pressing the Default button, the default values will be displayed as if you
had entered them. These values can be edited, applied or discarded.

Due to the nature of some configuration actions, default values may be


inappropriate. In these cases the Default button legend will be shown in grey,
inactive, signifying that this facility is not available.

The Roll Back button also provides a degree of security while performing
configuration operations. It provides a mechanism to restore previously set
attributes, similar to an undo feature.

On start-up, Configuration Manager retrieves all the current attributes of the


DCD. These attributes are used to configure the views and populate the
configuration dialogue windows. When an attribute is modified by the user,
the previous value is not lost, rather it is maintained as the roll back value.
The Roll Back button provides access to the roll back value.

It should be noted that roll back values are maintained only during the
execution of Configuration Manager. If attributes are modified and
Configuration Manager is shut-down, then the roll back values will be lost.

Due to the nature of some configuration actions, roll back values may be
inappropriate. In these cases the Roll Back button legend will be shown in
grey, inactive, signifying that this facility is not available.

The Shelf Pages


The other note book pages, shown initially behind the Overview page, provide more status and
configuration access. Each page may be brought to the front by selecting its tab.
These pages are the Shelf pages. Each shelf of your DCD will have its own page. For a fully
equipped DCD you may have five Shelf pages:
• Master - the Master Shelf.
• Exp1, Exp2, Exp3 - Expansion Shelves 1, 2 and 3.
• LPR - a Local Primary Reference Shelf.
You will notice that the tab of each shelf page has an LED. This provides an indication of the highest
severity condition currently associated with that shelf.

Page 16(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

It follows the standard colour convention:

(Red) Critical Condition


(Orange) Major Condition
(Yellow) Minor Condition
(Blue) Warning Condition
(White) Indeterminate Condition
(Green) No Condition

Figure 11 The Standard Alarm Colours

The Shelf pages differ from the Overview page in that, where the Overview depicts the conceptual
state of the DCD, the Shelf pages depict the actual front panel appearance of the DCD.
The Shelf pages have been provided for those who are already familiar and comfortable with the
front panel status indication of the DCD.

Figure 12 The Shelf Page

As you can see from the screen-shot above, the display is quite realistic. As with the Overview page,
the status represented by the LEDs on the Shelf pages is maintained in real-time.

Configuration Manager Page 17(62)


TMSL 197-46600-01 Issue 1: Sep 99

For instructions on interpreting the front panel indicators you should consult the appropriate
Telecom Solutions Equipment Module Descriptions.
An attempt has been made to present as much information as possible on these pages, but
unfortunately some LED states can not be derived from the management interface of the DCD. To
avoid confusion these LEDs are depicted as grey.
As well as LED status the shelf pages also provide other status information.

Output Protection

If a protection scheme is activated on a Timing Output Module then the module is


displayed with a shield denoting the protection scheme to which the module belongs to,
i.e. 1:1, 1:N, 1+1. There are several states associated with protected Timing Output
Modules:
Active - The Timing Output Module is currently selected to provide the reference signal.
An active Timing Output Module is denoted by a light blue shield

Stand-by - The Timing Output Module is not currently selected to provide the reference
signal. A Timing Output Module in stand-by mode is denoted by a light grey shield:

Protection Failure - The Timing Output Module is unable to function in the protection
scheme due to a failure or mis-match with its protection partner modules. A Timing
Output Module in Protection Failure mode is denoted by a red shield:

Page 18(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Removed (Disabled) Modules

If a module is removed (disabled) then the module will be shown as barred:

Figure 13 A Removed Module

All LEDs are shown grey as their states can not be derived.

Missing Modules

If a module is physically removed from the DCD shelf but is still provisioned within the
DCD inventory then the module will be shown as missing.

Figure 14 A Physically Missing (Non-Removed) Module

The graphic shows the type of module removed and acts as a reminder that another
module can not be entered into the DCD inventory until this one is deleted.

Configuration Manager Page 19(62)


TMSL 197-46600-01 Issue 1: Sep 99

Configuring the DCD from the Shelf Pages


As well as providing front panel status the Shelf pages also provide another method of configuring
DCD attributes. Again configuration is via simple point and click actions.
By simply placing the mouse over the module, shelf or even empty slot you wish to configure, and
pressing the right mouse button, a pull-down menu will be provided which will list all the
configuration actions appropriate to that item.:

Figure 15 A Typical Pull-down Menu On The Shelf Page

These menus and resulting dialogue windows work in exactly the same manner as those produced
by the Overview page.

Page 20(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

TimeSource 3000
There are two pages, the Overview page and the Shelf page. They are outlined below.

The Overview Page

The Overview page provides a simplified logical overview of TimeSource 3000. The
Overview page shows the received external inputs and the generated system outputs.

Figure 16 The TimeScan 3000 Overview Page

Configuration Manager Page 21(62)


TMSL 197-46600-01 Issue 1: Sep 99

Interpreting The Overview

The external inputs can each show one of three states. They are as follows:
Provisioned and Ensembled -This is shown as a blue pipe:

Provisioned but Not Ensembled -This is shown as grey pipe:

Not Provisioned and Not Ensembled -This is shown as a grey pipe with a barring symbol:

The Shelf Page

The Shelf pages differ from the Overview page in that, where the Overview depicts the
conceptual state of the DCD, the Shelf pages depict the actual front panel appearance of
the DCD.

Figure 17 The TimeSource 3000 Shelf Page (detail)

The Shelf page depicts the actual front panel appearance of TimeSource 3000. The LED
status shown on the Shelf page is maintained in real time.

Page 22(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Configuring the TimeSource 3000 From The Shelf Page

The Shelf page provides full configuration access. Configuration is via simple point and
click actions.
Place the mouse over the LED representing the equipment that you wish to configure, and
press the right mouse button. A menu will appear, listing all the configuration actions
which are appropriate to that equipment.

Figure 18 An Example LED Menu

When you place the mouse over any part of the Shelf page which does not show an LED,
when you right click, the following menu will be displayed:

Figure 19 The Non-LED Menu

n.b. The menus provided are context sensitive, that is, the menu shown depends on where
you right click. If you do not see the menu options that you expect, check that you have
clicked in the correct place.

Configuration Manager Page 23(62)


TMSL 197-46600-01 Issue 1: Sep 99

The TimeSource 3000 Menus

The following menus items are available from both TimeSource 3000 pages:
Window
Exit- exits the application.

Options
Confirm- this item toggles on and off the option which displays a
confirmation dialogue box when the changes to the database are requested.

Help
Help- this item brings up the online version of this help

About- this item displays a dialogue box with information about this
application.

Confirmation Dialogue Boxes

When you follow the instructions in the How To section (below), you may be presented
with Confirmation dialogue boxes. These work in exactly the same way as those for the
generic Configuration Manager, as outlined on page 24.

Page 24(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

How To...
The following sections describe how to use the Configuration Manager to perform some
common activities:
Enter Equipment Modules into a Shelf............................................... 27
Delete Equipment Modules from a Shelf. .......................................... 28
Remove / Restore Equipment Modules. ............................................. 28
Read Card Version.............................................................................. 29
Save / Load Configuration.................................................................. 29
Remove / Restore Input Ports. ............................................................ 30
Read / Set the Priority of an Input Port. ............................................. 31
Read / Set the Identity of an Input Port. ............................................. 32
Read / Set the Source of an Input Signal. ........................................... 33
Read / Set the Type of Input Signal.................................................... 34
Read / Set the Framing Mode of an Input Signal. .............................. 35
Read / Set the Origin of an Input Signal............................................. 36
Read / Set the Identity of an Output Port............................................ 38
Read / Set the Type of Oscillator........................................................ 39
Read / Set the Type of Output Signal. ................................................ 39
Read / Set the Protection Mode of a Timing Output Module............. 40
Read / Set the Framing Mode of a Timing Output Module................ 40
Read / Set the Destination of an Output Signal. ................................. 41
Read / Set the Real Time Clock of the DCD. ..................................... 42
Read the Current Alarm State of a Shelf. ........................................... 42
Read the Alarm History of the DCD. ................................................. 42
Clear the Alarm History of the DCD.................................................. 43
Operate the Alarm Cutoff. .................................................................. 43
Set the System Identifier (SID) of the DCD....................................... 44
Read / Set the Communication Parameters of the DCD..................... 44
Re-initialize an MIS module............................................................... 46

Configuration Manager Page 25(62)


TMSL 197-46600-01 Issue 1: Sep 99

Add, Amend and Delete User Security .............................................. 46


Read the Satellite Statistics from a GTI module. ............................... 47
TimeSource 3000- Ensemble / Unensemble a Span........................... 47
TimeSource 3000- Enable / Disable Monitoring for a Span .............. 48
TimeSource 3000- Ensemble / Unensemble a Remote
Oscillator (RO) ................................................................................... 48
TimeSource 3000- Enable / Disable Monitoring for a Remote
Oscillator (RO) ................................................................................... 48
TimeSource 3000- Set Cable Delay for a Global Positioning
System (GPS) ..................................................................................... 49
TimeSource 3000- Set Elevation Mask for a Global Positioning
System (GPS) ..................................................................................... 49
TimeSource 3000- Initialise a Global Positioning System (GPS)...... 50
TimeSource 3000- View Current Alarm State of a Shelf................... 50
TimeSource 3000- Operate the Alarm Cutoff .................................... 50
TimeSource 3000- Read / Set Alarm Output for an Output Port ....... 51
TimeSource 3000- Read / Set Frame Types for an Output Port......... 51
TimeSource 3000- Set Time Stamp for a Shelf.................................. 51
TimeSource 3000- Read / Set Remote Oscillator (RO) Frequency
for a Clock .......................................................................................... 52
TimeSource 3000- Reinitialise a TimeSource 3000 Card .................. 52
TimeSource 3000- Read Card Version Details .................................. 52

Page 26(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Entering Equipment Modules into a Shelf


Before you can configure or monitor equipment in a DCD you must first enter the module into the
DCD inventory.
To enter equipment modules:
• Ensure slot is shown as empty on the appropriate Shelf page. If not
then you must delete the existing module before you can enter a new
one.
• Physically place the module into the slot.
• Select the responding empty slot on the appropriate Shelf page. A list
of all the modules which may be inserted into that slot will be
produced. Simply select correct module from the list
• Follow the dialogue instructions and your new module will be
automatically entered and will appear in the shelf.

Figure 20 A Module List On The Shelf Page

If the module does not appear in the list then you are attempting to insert the module in an incorrect
slot.

Configuration Manager Page 27(62)


TMSL 197-46600-01 Issue 1: Sep 99

Deleting Equipment Modules from a Shelf


In order correctly physically remove equipment modules from a shelf the module must be deleted
from the DCD inventory. It is only possible to delete modules that are have first had their ports
removed (disabled), the module removed (disabled) and finally their ports deleted.
To delete equipment modules:
• Select the appropriate shelf page.
• Select the appropriate equipment module.
• Choose the Card Administration menu item.
• From the resultant sub-menu choose the Delete menu item.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
accepted. If successful the card graphic will disappear.
On entering equipment modules into the DCD inventory, some modules will default to a removed
(disabled) state. This is denoted by a barring symbol on the top of the module.

Removing or restoring equipment modules


• Select the appropriate shelf page. Select the appropriate equipment
module.
• Choose the Card Administration menu item.
• From the resultant sub-menu choose the Remove/Restore menu item.
• A dialogue box will be opened. The button highlights represents the
current value adopted by the DCD. Selection of another state may be
made selecting alternative button.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
accepted.

Page 28(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Reading Card Versions


All Cards contain an Inventory that holds:
Part Number, CLEI, Serial Number, Hardware Revision,
Software Revision, Software Version.
To open this dialogue:
• Choose the Card Administration menu item.
• Choose the Version menu item.
MIS modules, however, contain the following:
Part Number, CLEI, Serial Number, Hardware Revision
State, Software Revision, Software Version (High Bank)
State, Software Revision, Software Version (Low Bank)
To open this dialogue:
• Choose the Version menu item.

Saving/Loading Configurations
To read all data from the cards to the MIS module
• Select Read All Data from Cards
To write all data from the MIS module to the cards
• Select Write All Data to Cards
To read all data from the MIS module to the cards
• Select Card Administration
• Select Read Data from MIS
To write all data from the cards to the MIS module
• Select Card Administration
• Select Write Data to MIS

Configuration Manager Page 29(62)


TMSL 197-46600-01 Issue 1: Sep 99

Removing/ Restoring Input Ports


TimeScan supports many types of input reference modules. The MRC-EA and MRC-T input
reference modules provide a facility where their inputs can be removed (disabled) or restored
(enabled) remotely.
To remove or restore input ports:

From the Overview page:

• Select the appropriate port pipe.


• Choose the Port Administration menu item.
• From the resultant sub-menu choose the Remove/Restore menu
item....

From the Master Shelf page:

• Select the appropriate input module.


• Choose the Port Administration menu item.
• From the resultant sub-menu choose the Remove/Restore menu item.
• From the resultant sub-menu choose the appropriate port or all ports...
...
• A dialogue box will be opened. The button highlights represents the
current value adopted by the DCD. Selection of another state may be
made selecting alternative button.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
accepted.

Page 30(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Reading / Setting the Priority of an Input Port


Multi reference controllers (MRCs) support the prioritizing of input ports. The input with the
highest priority (1) will be selected as the reference source to its MRC provided, that reference is
deemed to be fit for use. If the priority (1) reference is lost or is deemed not fit for use then the MRC
will automatically select the next suitable input in order of priority 2-3-4.
n.b. DCIM card allow different input ports to have the same priority

To read / set the priority of an input port:

From the Overview page:

• Select the appropriate port pipe.


• Choose the Port Administration menu item.
• From the resultant sub-menu choose the Priority menu item.

From the Master Shelf page:

• Select the appropriate input module.


• Choose the Port Administration menu item.
• From the resultant sub-menu choose the Priority menu item.
• From the resultant sub-menu choose the appropriate port or all ports.
...
• A dialogue box will be opened. The value displayed represents the
current value adopted by the DCD. Selection of another value may be
made using the spin control.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new priority has
been accepted.
It should be noted that setting a new selection priority on a given port may cause the selection
priority of the other inputs to be modified by the MRC. This priority re-ordering may take several
seconds.

Configuration Manager Page 31(62)


TMSL 197-46600-01 Issue 1: Sep 99

Reading / Setting the Identity of an Input Port


TimeScan supports a port identity field for all ports of the input reference modules (MRC or CI).
The port identity is a text string which is intended to be used to uniquely identify the port.

To read / set the identity of an input port:

From the Overview page:

• Select the appropriate port pipe.


• Choose the Port Administration menu item.
• From the resultant sub-menu choose the Identity menu item.

From the Master Shelf page:

• Select the appropriate input module.


• Choose the Port Administration menu item.
• Form the resultant sub-menu choose the Identity menu item.
• Form the resultant sub-menu choose the appropriate port or all ports
for an MRC.
...
• A dialogue box will be generated providing an edit box containing the
current port identity. Note: if the identity has not been set the word
UNSET will appear.
The port identity may contain up to fifty printable characters. No
composition rules are imposed on this attribute, it is free text, so it can
follow any naming convention adopted by the Network
Administration.

The port identity may be edited by using the conventional line editing
facilities:
Left/right arrow keys.
Backspace.
Forward delete.
Shift left/right arrow to highlight text.
Control-x to delete highlighted text.
Control-c to copy highlighted text.
Control-v to paste.
Control-z to undo last edit action.

• Make your modifications and select Apply.


• Confirm action if required.
• A result dialogue box will inform you whether your new port identity
has been accepted.

Page 32(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Reading / Setting the Source of an Input Signal


n.b. This section (Reading / Setting the Source of an Input Signal) does not apply to DCIM cards.
Each reference input port has an attribute, source, associated with it. This attribute defines the
source of the synchronisation reference signal applied to that port and dictates the qualification
threshold applied to the reference signal.
Source may take one of four values:
Network
GPS
LORAN
Cesium

To read / set the source of an input signal:

From the Overview page:

• Select the appropriate signal wave form.


• Choose the Signal Administration menu item.
• From the resultant sub-menu choose the Source menu item.

From the Master Shelf page:

• Select the appropriate input module.


• Choose the Signal Administration menu item.
• From the resultant sub-menu choose the Source menu item.
• From the resultant sub-menu choose the appropriate port or all ports
for an MRC.
...
• A dialogue box will be opened. The value displayed represents the
current value adopted by the DCD. Selection of another value may be
made selecting a value from the drop list.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new signal source
has been accepted.

Configuration Manager Page 33(62)


TMSL 197-46600-01 Issue 1: Sep 99

Reading / Setting the Type of Input Signal


TimeScan supports many types of input reference modules. The MRC-EA input reference modules
provide a facility where the type of signal, digital or analogue, accepted by its ports may be
controlled remotely.
To read / set the type of input signal:

From the Overview page:

• Select the appropriate signal wave form.


• Choose the Signal Administration menu item.
• From the resultant sub-menu choose the ‘Type’ menu item.

From the Master Shelf page:

• Select the appropriate input module.


• Choose the Signal Administration menu item.
• From the resultant sub-menu choose the Type menu item.
• From the resultant sub-menu choose the appropriate port or all ports.
...
• A dialogue box will be opened. The value displayed represents the
current value adopted by the DCD. Selection of another value may be
made selecting a value from the drop list.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new signal type
has been accepted.

Page 34(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Reading / Setting the Framing Mode of an Input Signal


TimeScan supports many types of input reference modules. The MRC-EA and MRC-T input
reference modules provide a facility where the framing mode, accepted by their ports may be
controlled remotely.
To read / set the framing mode of an input signal:

From the Overview page:

• Select the appropriate signal wave form.


• Choose the Signal Administration menu item.
• From the resultant sub-menu choose the Framing menu item.

From the Master Shelf page:

• Select the appropriate input module.


• Choose the Signal Administration menu item.
• From the resultant sub-menu choose the Framing menu item.
• From the resultant sub-menu choose the appropriate port or all ports.
...
• A dialogue box will be opened. The value displayed represents the
current value adopted by the DCD. Selection of another value may be
made selecting a value from the drop list.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new signal
framing mode has been accepted.

Configuration Manager Page 35(62)


TMSL 197-46600-01 Issue 1: Sep 99

Reading / Setting the Origin of an Input Signal


TimeScan supports a signal origin field for all ports of the input reference modules (MRC or CI).
The signal origin is a text string which is intended to be used to uniquely identify the path or source
of the reference signal.

If used properly this attribute can be extremely useful. For example, if the signal applied to an input
port is lost due to a bearer cut or the failure of the up-stream source then it may be necessary to
quickly identify the bearer or source. To do this manually by attempting to trace through the
Network Connection Plan may be very time consuming. However, if the signal origin is already
defined then you need only select this facility.

To read / set the origin of an input signal:

From the Overview page:

• Select the appropriate signal wave form.


• Choose the Signal Administration menu item.
• From the resultant sub-menu choose the Origin menu item.

From the Master Shelf page:

• Select the appropriate input module.


• Choose the Signal Administration menu item.
• Form the resultant sub-menu choose the Origin menu item.
• Form the resultant sub-menu choose the appropriate port or all ports
for an MRC.
...
• A dialogue box will be generated providing an edit box containing the
current signal origin. Note: if the origin has not been set the word
UNSET will appear.
The signal origin may contain up to fifty printable characters. No
composition rules are imposed on this attribute, it is free text, so it can
follow any naming convention adopted by the Network
Administration.

The origin may be edited by using the conventional line editing


facilities:
Left/right arrow keys.
Backspace.
Forward delete.
Shift left/right arrow to highlight text.
Control-x to delete highlighted text.
Control-c to copy highlighted text.
Control-v to paste.
Control-z to undo last edit action.

Page 36(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

• Make your modifications and select Apply.


• Confirm action if required.
• A result dialogue box will inform you whether your new origin has
been accepted.

Configuration Manager Page 37(62)


TMSL 197-46600-01 Issue 1: Sep 99

Reading/ Setting the Identity of an Output Port


TimeScan supports a port identity field for all ports of the Timing Output (TO) modules. The port
identity is a text string which is intended to be used to uniquely identify the port.

To read / set the identity of an output port:

• Select the appropriate shelf page.


• Select the appropriate TO module.
• Choose the Port Administration menu item.
• From the resultant sub-menu choose the Identity menu item.
• From the resultant sub-menu choose the appropriate port or all ports.
• A dialogue box will be generated providing an edit box containing the
current port identity. Note: if the identity has not been set the word
UNSET will appear.
The port identity may contain up to fifty printable characters. No
composition rules are imposed on this attribute, it is free text, so it can
follow any naming convention adopted by the Network
Administration.

The port identity may be edited by using the conventional line editing
facilities:
Left/right arrow keys.
Backspace.
Forward delete.
Shift left/right arrow to highlight text.
Control-x to delete highlighted text.
Control-c to copy highlighted text.
Control-v to paste.
Control-z to undo last edit action.

• Make your modifications and select Apply.


• Confirm action if required.
• A result dialogue box will inform you whether your new port identity
has been accepted.

Page 38(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Reading / Setting the Type of Oscillator


MRC modules can have different types of Oscillators, Rubidium and Quartz. To set the type
• Select Card Administration
• Select Oscillator Types’

Reading / Setting the Type of Output Signal


TimeScan supports many types of Timing Output modules. The TO-EA modules provides a facility
where the type of signal, digital or analogue, generated by its ports may be controlled remotely.
To read / set the type of output signal:
• Select the appropriate shelf page.
• Select the appropriate TO module.
• Choose the Signal Type menu item.
• From the resultant sub-menu choose the Type menu item.
• From the resultant sub-menu choose the appropriate port or all ports.
• A dialogue box will be opened. The value displayed represents the
current value adopted by the DCD. Selection of another value may be
made selecting a value from the drop list.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new signal type
has been accepted.

Configuration Manager Page 39(62)


TMSL 197-46600-01 Issue 1: Sep 99

Reading / Setting the Protection Mode of a Timing Output


Module
TimeScan supports many types of Timing Output modules. The TO-EA modules provides a facility
where the protection mode employed for its output signals may be controlled remotely.
To read / set the protection mode of a Timing Output module:
• Select the appropriate shelf page.
• Select the appropriate TO module.
• Choose the Card Administration menu item.
• From the resultant sub-menu choose the Protection Type menu item.
• A dialogue box will be opened. The value displayed represents the
current value adopted by the DCD. Selection of another value may be
made selecting a value from the drop list.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new protection
mode has been accepted.

Reading / Setting the Framing Mode of a Timing Output


Module
TimeScan supports many types of Timing Output modules. The TO-EA modules provides a facility
where the framing mode employed for its output signals may be controlled remotely.
To read / set the framing mode of a Timing Output module:
• Select the appropriate shelf page.
• Select the appropriate TO module.
• Choose the Card Administration menu item.
• From the resultant sub-menu choose the Framing menu item.
• A dialogue box will be opened. The value displayed represents the
current value adopted by the DCD. Selection of another value may be
made selecting a value from the drop list.
• Make your modification and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new signal
framing mode has been accepted.

Page 40(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Reading / Setting the Destination of an Output Signal


TimeScan supports a signal destination field for all ports of the Timing Output modules. The signal
destination is a text string which is intended to be used to uniquely identify the path or down-stream
target of the output signal.

To read / set the destination of an output signal:

• Select the appropriate shelf page.


• Select the appropriate TO module.
• Choose the Signal Destination menu item.
• Form the resultant sub-menu choose the appropriate port or all ports.
• A dialogue box will be generated providing an edit box containing the
current signal destination. Note: if the destination has not been set the
word UNSET will appear.
The signal destination may contain up to fifty printable characters. No
composition rules are imposed on this attribute, it is free text, so it can
follow any naming convention adopted by the Network
Administration.

The destination may be edited by using the conventional line editing


facilities:
Left/right arrow keys.
Backspace.
Forward delete.
Shift left/right arrow to highlight text.
Control-x to delete highlighted text.
Control-c to copy highlighted text.
Control-v to paste.
Control-z to undo last edit action.

• Make your modifications and select Apply.


• Confirm action if required.
• A result dialogue box will inform you whether your new destination
has been accepted.

Configuration Manager Page 41(62)


TMSL 197-46600-01 Issue 1: Sep 99

Reading/ Setting the Real Time Clock of the DCD


The Master Shelf MIS module maintains the real time clock for the entire DCD.
To read / set the DCD real time:
• Select the Master shelf page.
• Select the MIS menu.
• Choose the Time menu item.
• A dialogue box will be opened providing a snap shot of the real time
current measured by the DCD.
• All fields may be edited directly or by using the spin controls.
• Make your modifications and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new time setting
has been accepted.

Reading the Current Alarm State of a Shelf


The MIS module of each shelf an Alarm List which lists all the current alarm conditions outstanding
on that shelf.

To view an Alarm List:


• Select the appropriate Shelf page.
• Select the MIS menu.
• Choose the Alarm List menu item.
• An information dialogue box will be opened listing the contents of the
Alarm List.

Reading the Alarm History of the DCD


The Master shelf MIS provides an Alarm History for the entire DCD in the form of a log.

To view the log:


• Select the Master shelf page.
• Select the MIS menu.
• Choose the Alarm Log menu item.
• An information dialogue box will be opened listing the contents of the
Alarm Log.

Page 42(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Clearing the Alarm History of the DCD


The Master shelf MIS provides an Alarm History for the entire DCD in the form of a log.

To clear the Alarm History:


• Select the Master shelf page.
• Select the MIS menu.
• Choose the Clear Log menu item.
• Confirm action if required.
• A result dialogue box will inform you of the result.

Operating the Alarm Cutoff


This dialogue enables you to silence all local audible alarms on the DCD.

To operate the Alarm Cutoff:

• Select the Master shelf page.


• Select the MIS menu.
• Choose the Operate Alarm Cutoff menu item.
• Confirm action if required.
• A result dialogue box will inform you whether alarm cutoff as
operated.

Configuration Manager Page 43(62)


TMSL 197-46600-01 Issue 1: Sep 99

Setting the System Identifier (SID) of the DCD


The Master shelf MIS provides an identifying string known as the System Identifier (SID). This
string forms the basis of the header for all command responses and notifications generated by the
DCD.

To read or set the SID:


• Select the Master shelf page.
• Select the MIS menu.
• Choose the System Identifier menu item.
• A dialogue box will be generated providing an edit box containing the
current System Identifier. The SID may be edited by using the
conventional line editing facilities:
Left/right arrow keys.
Backspace.
Forward delete.
Shift left/right arrow to highlight text.
Control-x to delete highlighted text.
Control-c to copy highlighted text.
Control-v to paste.
Control-z to undo last edit action.
• Make your modifications and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your new SID has been
accepted.
Note a quick method of viewing the System Identity is to invoke the Master shelf menu by clicking
on the top panel of the shelf. The resulting menu will display the System Identifier has its title.

Reading / Setting the Communication Parameters of the


DCD
The MIS module of the DCD Master shelf provides three serial communication ports for
management facilities. Each communication port has a host of configurable attributes which control
its behaviour.
To read or set communication parameters of the DCD:
• Select the Master shelf page.
• Select the MIS menu.
• Choose the Communications menu item.
• From the sub-menu select the communication port you wish to
modify.

Page 44(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

• A dialogue box will be generated providing a control for each attribute


of that port. The values displayed in the controls are the current
attribute settings.
The following list provides a brief description of each attribute:
Baud Rate - This is the data transfer rate of the port. Two values may be selected form the drop list
9600 / 1200. It should be noted that if the baud rate of the port currently used by TimeScan is
changed then TimeScan should be closed. The baud rate set in the Shortcut window should be
modified accordingly and the Tool Palette re-launched. It is not possible to modify the baud rate of
communication port 2.
Monitor - This check box controls the ability of the port to monitor the activity on other ports. It
should be noted that Monitor must be turned off, un-checked, for the port currently used by
TimeScan.
Keep Alive - This check box controls the ability of the port to send spontaneous messages.
Com Type - Each communication port supports four communication types:
X.25 - for direct connection to an X.25 PAD.
Modem - for direct connection to a PSTN modem.
Terminal - for direct connection to a Terminal.
Remote - for direct connection to a remote expansion
shelf.
It should be noted that Com Type must be set to Term, for the port currently used by TimeScan.
End of Text - This attribute represents the numeric value of the ASCII character to be used as an
additional terminating character. Zero indicates no additional terminating character. It should be
noted that End of Text must be set to zero, ‘00’, for the port currently used by TimeScan.
Echo - This check box controls the ability of the port to echo received characters. It is recommended
that Echo should be turned off, un-checked, for the port currently used by TimeScan.
Report Alarms - This check box controls the ability of the port to send spontaneous alarm messages.
It is recommended that Report Alarms should be turned on, checked, for the port currently used by
TimeScan.
Hardware flow control - This check box controls whether the port uses hardware flow control.
Software flow control - This check box controls whether the port uses software flow control.
Back to the procedure:
• Make your modifications and select Apply.
• Confirm action if required.
• A result dialogue box will inform you whether your modifications
have been successful made.
Note: All modifications on communication port 2 will result in a partially executed response due to
the inability to set the baud rate of this port.

Configuration Manager Page 45(62)


TMSL 197-46600-01 Issue 1: Sep 99

Re-initializing an MIS module


It is possible to re-initialize the software of an MIS module. This action may be necessary on
installation and does not affect the synchronisation performance of the shelf or DCD.
To re-initialize an MIS module:
• Select the Shelf page of the MIS to be re-initialized.
• Select the MIS menu.
• Choose the Re-initialize... menu item.
• A dialogue box will be generated providing a warning.
• If you intend to proceed, select Apply.
• Confirm action if required.
• Configuration Manager will send the appropriate commands and
provide a dialogue with the result of the re-initialisation. If successful
the MIS module will restart. All communications with the MIS will
cease for approximately thirty seconds. At this point TimeScan must
be closed and restarted. Close the Configuration Manager, any other
TimeScan tools and finally the Tool Palette.

Adding, Amending and Deleting User Security


The MIS card supports up to 17 Users in its security features. The range of features available to
individual Users depends upon their Access Level. The DCD determines what access level allows
what feature.

Adding a User:

• Select the MIS menu


• Choose the Security, Add User... menu items.
• A dialogue box will be generated. Enter the required User Name,
Password and Security Level.
• If you intend to proceed, select Apply.
• Confirm action if required.

Editing a User:

• Select the MIS menu


• Choose the Security, Edit Users... menu items.
• A dialogue box will be generated. Listing the Current User IDs as well
as box to hold the new user IDs, Passwords and Security Levels. This
dialogue will also allow you to enter a new user
• If you intend to proceed, select Apply.
• Confirm action if required.

Page 46(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Deleting a User:

• Select the MIS menu


• Choose the Security, Delete User.’ menu items.
• A dialogue box will be generated. Enter the User Name for the User
you wish to delete.
• If you intend to proceed, select Apply.
• Confirm action if required.

Changing SSM Support

n.b. This section (Changing SSM Support) only applies to MIS Version 5.04 and above.
• Select the MIS menu.
• Choose the Select SSM support item.
• A dialogue box will be generated. Choose the type of SSM support
which you require.
• Press Apply to keep your changes or Cancel to close the box without
keeping the changes.

Reading the Satellite Statistics from a GTI module


To read the satellite statistics from a GTI module:
• Select the LPR Shelf page.
• Select the appropriate GTI menu.
• Choose the GPS Stats menu item.
• An information dialogue box will be opened listing GPS statistics
including a snap shot of UTC time, location, satellites in view and
their co-ordinates.

TimeSource 3000- Ensemble / Unensemble a Span


To ensemble or unensemble as span, go to the TimeSource 3000 shelf page and:
• Right click on a span LED on the shelf page.
• Select the Ensembling. menu item to bring up the Ensembling
dialogue box.
• Click on the Allow button to enable ensembling, or the Inhibit button
to disable it.
• Click Apply to close the box and save your changes.
• Confirm action if required.

Configuration Manager Page 47(62)


TMSL 197-46600-01 Issue 1: Sep 99

• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000- Enable / Disable Monitoring for a Span


To enable or disable monitoring for a span:
• Right click on a span LED on the shelf page.
• Select the Monitoring.. item from a popup menu. This will bring up
the Monitoring dialogue box.
• Click on either the Disable or Enable button, as appropriate.
• Click Apply to close the box and save changes.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000- Ensemble / Unensemble a Remote


Oscillator (RO)
To Ensemble or Unensemble a Remote Oscillator:
• Right click on an RO LED on the shelf page.
• Select the Ensembling.. menu item to bring up the Ensembling
dialogue box.
• Click on the Allow button to enable ensembling, or the Inhibit button
to disable it.
• Click Apply to close the box and save any changes.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000- Enable / Disable Monitoring for a


Remote Oscillator (RO)
To Enable or disable monitoring for a Remote Oscillator:
• Right click on an RO LED on the shelf page.
• Select the Monitoring.. item from a popup menu. This will bring up
the Monitoring dialogue box.
• Click on either the Disable or Enable button, as appropriate.
• Press Apply to close the dialogue box and save your changes.

Page 48(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

• Confirm action if required.


• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000- Read / Set Cable Delay for a Global


Positioning System (GPS)
• Right click on the GPS LED on the shelf page.
• Select Antenna Administration for the popup menu, then select Cable
Delay.. from the sub-menu to display the Cable Delay dialogue box.
• Either type directly into the text box, or use the arrows, to input the
required value. It is in metres, and must be in the range 0-330.
• Press Apply to close the dialogue box and save your changes. Click
Cancel to simply close the box.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000- Read / Set Elevation Mask for a Global


Positioning System (GPS)
To set the elevation mask angle for a global positioning system:
• Right click on the GPS LED on the shelf page.
• Select Antenna Administration from the popup menu, and Elevation
Mask.. from the resulting sub-menu. This will bring up the Elevation
Mask dialogue box.
• Either type in the required new value, or use the arrows. The unit is
degrees, and the value must be in the range 0-45.
• Click Apply to close the dialogue box and save your changes. Click
Cancel to simply close the box.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

Configuration Manager Page 49(62)


TMSL 197-46600-01 Issue 1: Sep 99

TimeSource 3000- Initialise a Global Positioning System


(GPS)
To initialise a global positioning system:
• Right click on the GPS LED on the shelf page.
• Select Initialise GPS.. from the drop down menu.This will bring up
the Initialise GPS dialogue box.
• Click either the Reset Receiver or Reset Entire Database to default
settings button.
• Click Apply to begin the initialisation and close the dialogue box.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000 - View Current Alarm State of a shelf


nb: All 3 alarm buttons will provide you with the same information.
To view the current the alarms for a shelf:
• Right click on any of the alarm LEDs on the shelf page.
• Select Alarm List.. from the drop down menu.
• A list of currently active alarms for that particular shelf will be
displayed. It will be in TL1 response format.
• Press OK to close the Alarm List window and return to the Shelf page.

TimeSource 3000- Operating the Alarm Cutoff


To silence audible alarms on a shelf:
• Right click on the Aco LED.
• Select the Alarm Cutoff item from the popup menu.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

Page 50(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

TimeSource 3000- Read / Set Alarm Output for an Output


Port
To read or set the Alarm Output for a given port:
• Right click anywhere on the shelf page EXCEPT one of the LEDs.
• Select TI Output from the popup menu.
• From the resulting sub-menu, select the output port (TI-A.. or T1-B..)
whose alarm output you want to read or set. The Alarm Outputs
dialogue will appear.
• Select the required Alarm Output from the drop down list box. The
options are SSM, SQUELCH or AIS.
• Click Apply to close the dialogue box and save any changes that you
have made. Click Cancel to simply close the box.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.
nb. You cannot set the Alarm Output value to SSM unless the Frame Type value is set to ESF. (See
the following section, How to Read / Set the Frame Type for an Output Port.)

TimeSource 3000- Read / Set Frame Types for an Output


Port
To read or set the frame type for an output port:
• Right click anywhere on the shelf page EXCEPT one of the LEDs.
• Select the Frame Type.. item from the popup menu. This will bring up
the Frame Type dialogue box.
• Chose an option from the drop down list box. The options are ESF and
D4.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000- Set Time Stamp for a Shelf


To set the Time Stamp for a shelf:
• Right click anywhere on the shelf page EXCEPT one on the LEDs.
• Select Time.. from the popup menu. The time dialogue box will be
displayed.
• Either type the required values directly into each time field, or use the
arrow keys to enter them.

Configuration Manager Page 51(62)


TMSL 197-46600-01 Issue 1: Sep 99

• Click Apply to close the dialogue box and save your changes.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.

TimeSource 3000- Read / Set Remote Oscillator (RO)


Frequency for a Clock
To read or set the frequency of a remote oscillator:
• Right click anywhere on the shelf page EXCEPT one of the LEDs
• Select RO Frequency.. from the popup menu. This will display the
Remote Oscillator Frequency dialogue box.
• Select a frequency from those in the drop down list box. The options
are either 5 or 10 MHz.
• Click Apply to close the box and save changes, or Cancel to just close
the box.
• Confirm action if required.
• A result dialogue box will inform you whether your action has been
successful.
nb. Since both oscillators must be set to the same value, they are set simultaneously.

TimeSource 3000- Reinitialise a TimeSource 3000


Card
To reset a card to its default values:
• Right click anywhere on the shelf page EXCEPT on one of the LEDs.
• Select the Card Administration item from the drop down menu. Select
the Initialise Card item from the resulting sub-menu.
• Confirm action if required.
• There may be a short delay during the initialisation. The card will be
reconnected after initialisation is complete.

TimeSource 3000- Read Card Version Details


To find version information for a given card:
• Right click anywhere on the shelf page EXCEPT on one of the LEDs.
• Select the Card Administration item from the popup menu.
• Select the Version item from the resulting sub-menu.

Page 52(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

• A dialogue will be displayed which shows the all the available version
information for the card.
• Click OK to close the window and return to the shelf page.

Configuration Manager Page 53(62)


TMSL 197-46600-01 Issue 1: Sep 99

Frequently Asked Questions...

1 Q. I have tried to delete a module form a shelf but I keep getting


the error message, “Invalid sequence”... why?
A. The module is not in the correct state for deletion. In general for modules with
input or output ports the following procedure must be followed:

1 Remove all ports.

2 Remove module.

3 Delete all ports.

4 Delete module.

2 Q. I have physically removed a module from a shelf. Can I delete


it form the DCD inventory without putting it back?
A. Yes... although the module is shown has missing, if you select this graphic it will
still provide the configuration menus for that module so you can still delete it.

3 Q. There is a module shown on a shelf page. The module is not


removed (disabled) but all of the LEDs are shown grey... why?
A. Unfortunately TimeScan can not accurately determine the state of the LEDs.

4 Q. When I open Configuration Manager the shelves shown are


different to my actual DCD shelves. Is this a fault?
A. No. you have not selected the correct Element Type when you created the
shortcut with the TimeScan Shortcut tool.

Page 54(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Chapter Index

Alarm Cutoff
-Generic ..................................................................................................................... 43
-TimeSource 3000 ................................................................................................. 50
Alarm History
-Clearing .................................................................................................................... 43
-Reading .................................................................................................................... 42
Alarm Log .................................................................................................................................. 42
Alarm Output
-Reading (TimeSource 3000) ............................................................................ 51
-Setting (TimeSource 3000) ............................................................................... 51
Alarm State
-Reading From Shelf ............................................................................................. 42
-Reading From Shelf (TimeSource 3000) ..................................................... 51
Analogue Signals ...................................................................................................................... 9
Apply button .............................................................................................................................. 14

Barred Symbol ......................................................................................................................... 19


Baud Rate, setting for DCD ................................................................................................. 45

Cable Delay
-Setting For GPS (TimeSource 3000) ............................................................. 49
Cancel button ........................................................................................................................... 15
Card
-Deleting From Shelf ............................................................................................. 28
-Entering onto Shelf ............................................................................................... 27
-Finding Version of ................................................................................................ 29
-Finding Version Of (TimeSource 3000) ........................................................ 52
-Inventory .................................................................................................................. 29
-Reinitialise (Time Source 3000) ...................................................................... 52
-Removing from Shelf ........................................................................................... 28
-Restoring to Shelf ................................................................................................. 28
CI .................................................................................................................................................... 9
CLK ................................................................................................................................................ 6
Clock Inputs ................................................................................................................................ 9
Clock Module.............................................................................................................................. 11
-Active .........................................................................................................................11
-Lock state .................................................................................................................11
-Not Available ...........................................................................................................11
-Stand-by ....................................................................................................................11
Clock Modules ..........................................................................................................................11
Clock Oscillator Modules ........................................................................................................ 6
Com Type, setting for DCD ................................................................................................. 45
Communication Parameters
-Reading for DCD .................................................................................................. 44

Configuration Manager Page 55(62)


TMSL 197-46600-01 Issue 1: Sep 99

-Setting for DCD ..................................................................................................... 44


Configuration Dialogue Windows ...................................................................................... 14
Confirm ......................................................................................................................................... 3
Confirmation Dialogue Box
-Generic ..................................................................................................................... 14
-TimeSource 3000 ................................................................................................. 24

DCD
-Active Signal Path ................................................................................................ 10
-Clearing Alarm History ........................................................................................ 43
-Configuring .............................................................................................................. 14
-Internal Signal Distribution ................................................................................ 12
-Reading Alarm History ........................................................................................ 42
-Reading Communications Parameters for ................................................... 44
-Reading Real Time Clock of ............................................................................. 42
-Setting Communications Parameters for ..................................................... 44
-Setting of System Identifier for ......................................................................... 44
-Setting Real Time Clock of ................................................................................ 42
Digital Clock Device: see DCD
Default Button .......................................................................................................................... 16
Digital Signals ........................................................................................................................ 8, 9

Echo, setting for DCD ........................................................................................................... 45


Elevation Mask, setting for GPS (TimeSource 3000) ................................................ 49
End of Text, setting for DCD ............................................................................................... 45
Ensemble
-Remote Oscillator (RO) (TimeSource 3000) ............................................... 48
-Span (TimeSource 3000) ................................................................................... 47
Exit ................................................................................................................................................. 3
Expansion Shelves ................................................................................................................. 16

Frame Type
-Reading (TimeSource 3000) ............................................................................ 51
-Setting (TimeSource 3000) ............................................................................... 51
Framing Mode
-Reading of Input .................................................................................................... 35
-Reading of Timing Output Module .................................................................. 40
-Setting of Input ...................................................................................................... 35
-Setting of Timing Output Module ..................................................................... 40
Frequency
-Read For Remote Oscillator (TimeSource 3000) ...................................... 52
-Set For Remote Oscillator (TimeSource 3000) .......................................... 52

Page 56(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Global Positioning System


-Initialise (Time Source 3000) ............................................................................ 50
-Setting Cable Delay (TimeSource 3000) ...................................................... 49
-Setting Elevation Mask (TimeSource 3000) ................................................ 49
GPS: see Global Positioning System
GTI module, reading from .................................................................................................... 47

Hardware Flow Control ........................................................................................................... 29


Help ............................................................................................................................................... 3

Identity
-Reading for Input Port ......................................................................................... 32
-Reading of Output Port ....................................................................................... 38
-Setting for Input Port ............................................................................................ 32
-Setting of Output Port .......................................................................................... 38
Informational Dialogue Windows ....................................................................................... 13
Input Port
-Active .......................................................................................................................... 7
-Deleted ....................................................................................................................... 8
-Reading Identity .................................................................................................... 32
-Reading Priority ..................................................................................................... 31
-Reference Signal .................................................................................................... 8
-Removed ................................................................................................................... 7
-Removing ................................................................................................................ 30
-Restoring ................................................................................................................. 30
-Setting Identity ....................................................................................................... 32
-Setting Priority ....................................................................................................... 31
-Source Type ............................................................................................................. 8
-Stand-by ..................................................................................................................... 7
-TimeSource 3000 ................................................................................................... 22
Input Reference Module ........................................................................................................... 9
-Active ........................................................................................................................ 10
-Not Equipped ......................................................................................................... 10
-Stand-by ................................................................................................................... 10
Input Signal
-Reading Framing Mode of ................................................................................. 35
-Reading Origin of .................................................................................................. 36
-Reading Source of ............................................................................................... 33
-Reading Type of .................................................................................................... 34
-Setting Framing Mode of .................................................................................... 35
-Setting Origin of .................................................................................................... 36
-Setting Source of .................................................................................................. 33
-Setting Type of ...................................................................................................... 34
Invalid Sequence Message ................................................................................................. 54
Inventory of Card .................................................................................................................... 29

Configuration Manager Page 57(62)


TMSL 197-46600-01 Issue 1: Sep 99

Keep Alive, setting for DCD ................................................................................................ 45

LED
-Shelf Tab ................................................................................................................. 16
-TimeSource 3000 ................................................................................................. 23
Loading Configurations ......................................................................................................... 29
Local Primary Reference Shelf .......................................................................................... 16
LPR Shelf: see Local Primary Reference Shelf

Master Shelf ............................................................................................................................. 16


Menu
-Bar ............................................................................................................................... 3
-Help ............................................................................................................................. 3
-Options ....................................................................................................................... 3
-Window ....................................................................................................................... 3
MIS
-Loading Configurations from ............................................................................ 29
-Reinitializing of Module ....................................................................................... 46
-Saving Configurations .......................................................................................... 29
Module
-Removing from Shelf ........................................................................................... 28
Monitor, setting for DCD ....................................................................................................... 45
Monitoring
-Remote Oscillator (RO) ...................................................................................... 48
-Span (TimeSource 3000) ................................................................................... 48
MRC-EA ..................................................................................................................................... 34
MRCs: see Multi Reference Controllers
Multi Reference Controllers ......................................................................................... 6, 9, 31

Network Connection Plan .................................................................................................... 36


Note Book Pages ...................................................................................................................... 3

OK button .................................................................................................................................. 13
Opening Configuration Manager ......................................................................................... 3
Options ......................................................................................................................................... 3
Oscillator
-Reading Type of .................................................................................................... 39
-Setting Type of ...................................................................................................... 39

Page 58(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Output Port .................................................................................................................................. 6


-Read Frame Type (TimeSource 3000) ......................................................... 51
-Reading Alarm Output (TimeSource 3000) ................................................. 51
-Reading Identity of ............................................................................................... 38
-Setting Alarm Output (TimeSource 3000) .................................................... 51
-Setting Frame Type (TimeSource 3000) ...................................................... 51
-Setting Identity of .................................................................................................. 38
Output Protection .................................................................................................................... 18
Output Signal
-Reading Destination of ....................................................................................... 41
-Reading Type of .................................................................................................... 39
-Setting Desination of ........................................................................................... 41
-Setting Type of ...................................................................................................... 39
Overview
-Page ............................................................................................................................ 5
-TimeSource300 Page ......................................................................................... 21

Page
-Overview .................................................................................................................... 5
-Shelf .......................................................................................................................... 16
Port Number ............................................................................................................................... 8
Ports
-Input ............................................................................................................................ 6
-Output ......................................................................................................................... 6
Print
-Preview ....................................................................................................................... 3
-Setup ........................................................................................................................... 3
Printing ......................................................................................................................................... 3
Priority
-Reading For Input Port ....................................................................................... 31
-Re-ordering ............................................................................................................. 31
-Setting For Input Port .......................................................................................... 31
Protection Mode
-Failure ....................................................................................................................... 18
-Reading of Timing Output Module .................................................................. 40
-Setting of Timing Output Module ..................................................................... 40

Real Time Clock of DCD


-Reading .................................................................................................................... 42
-Setting ...................................................................................................................... 42
Reference Signal, graphical representations .............................................................. 8, 9
Remote Oscillator
-Ensemble (TimeSource 3000) ......................................................................... 48
-Monitoring ................................................................................................................ 48
-Read Frequency (TimeSource 3000) ............................................................ 52
-Set Frequency (TimeSource 3000) ................................................................ 52
-Unemsemble (TimeSource 3000) ................................................................... 48
Report Alarms, setting for DCD ......................................................................................... 45
RO: see Remote Oscillator

Configuration Manager Page 59(62)


TMSL 197-46600-01 Issue 1: Sep 99

Roll Back
-Facility ...................................................................................................................... 16
-Limitations Of ......................................................................................................... 16

Satellite Statistics, reading .................................................................................................. 47


Saving Configurations ........................................................................................................... 29
Shelf
-Filling ......................................................................................................................... 27
-Page .......................................................................................................................... 16
-Reading Alarm State of ...................................................................................... 42
-Removing Card from ........................................................................................... 28
-TimeSource 3000 Page ...................................................................................... 22
Signal Destination
-As Text String ........................................................................................................ 41
-Reading of Output ................................................................................................ 41
-Setting of Output ................................................................................................... 41
Signal Origin
-As Text String ........................................................................................................ 36
-Reading of Input .................................................................................................... 36
-Recovery of ............................................................................................................. 36
-Setting ...................................................................................................................... 36
-Setting of Input ...................................................................................................... 36
Signal Source
-Reading of Input .................................................................................................... 33
-Setting of Input ...................................................................................................... 33
Signal Type
-Reading of Input .................................................................................................... 34
-Reading of Output ................................................................................................ 38
-Setting of Input ...................................................................................................... 34
-Setting of Output ................................................................................................... 38
Software Flow Control ........................................................................................................... 45
Source
-Reading .................................................................................................................... 33
-Type ............................................................................................................................ 8
Span
-Ensemble (TimeSource 3000) ......................................................................... 47
-Unemsemble (TimeSource 3000) ................................................................... 47
Start Up
-Status Bar Messages ............................................................................................ 4
-Messages .................................................................................................................. 4
System Identifier
-As String .................................................................................................................. 44
-Setting of for DCD ................................................................................................ 44

Page 60(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Time
-Set For Shelf (Time Source 3000) .................................................................. 51
TimeSource 3000
-Menus ....................................................................................................................... 24
-Specific Information ............................................................................................. 21
Timing Output Module
-Reading Framing Mode of ................................................................................. 40
-Reading Protection Mode of ............................................................................. 40
-Setting Framing Mode of .................................................................................... 40
-Setting Protection Mode of ................................................................................ 40
TO Array .................................................................................................................................6, 11
-Active .........................................................................................................................11
-Not Active ................................................................................................................ 12
TO-EA ......................................................................................................................................... 40
TO: see Timing Output

Undo ............................................................................................................................................ 16
Unensemble
-Remote Oscillator (RO) (TimeSource 3000) ............................................... 48
-Span (TimeSource 3000) ................................................................................... 47
User Security
-Adding ...................................................................................................................... 46
-Deleting .................................................................................................................... 47

Version
-Of Card (Generic) ................................................................................................. 29
-Of Card (TimeSource 3000) ............................................................................. 52

Window Menu ............................................................................................................................ 3

Configuration Manager Page 61(62)


TMSL 197-46600-01 Issue 1: Sep 99

(This page intentionally left blank)

Page 62(62) Configuration Manager


Issue 1: Sep 99 TMSL 197-46600-01

Alarm Forwarding

Why would I Use Alarm Forwarding?


NMS may be set-up to forward alarms to an external system. The external system
must listen on a TCP/IP socket and receive textual based alarm / event and
clearing messages once a connection has been established.

What’s In This User Guide?


This document contains everything you need to know to use the NMS Alarm
Forwarding System. There is a Contents list on page 2. If you need to use this
guide as a quick reference, there is a keyword index at the end (page 8).

Alarm Forwarder Page 1(10)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Contents
Alarm forwarder NMS service ............................................................. 3
Regular Expression Format .................................................................. 5
Supervised Processes files .................................................................... 7
Chapter Index ....................................................................................... 8

Page 2(10) Alarm Forwarder


Issue 1: Sep 99 TMSL 197-46600-01

Alarm forwarder NMS Service


A new NMS service “SimpleAlarmForwarder” can now be added to the SupervisedProcesses.txt
files. This service controls the alarm forwarding function. On start-up the service reads a
configuration file (default= AlarmForwarder.txt) which defines the forwarding destination, the
severity filter, and a regular expression criteria.This file can be found in the $MONITORHOME/
configs directory.

// Simple alarm forwarding configuration file


DestinationAdresss=inet:11.103.41.99:1234567
SeverityFilter="WARNING" // values
CRITICAL,MAJOR,MINOR,WARNING,NONE
AlarmMatchRE=".*" // matches all
Acknowledgments=NO // YES/NO
RetryIntervalOnFailedsocket=15000 // timeout in milliseconds
AckTimeout=15 // timeout in seconds
AlarmBufferSize=20 // number of alarms to buffer up in failure situation

Figure 1 Alarm Forwarder Configuration file

The parameters in the config file have the following format:


• DestinationAdresss = inet:<IP or known hostname>:<socket
number>.

• SeverityFilter = <severity value> from the following list:


• CRITICAL: Forward only critical alarms
• MAJOR: Forward only Critical and major
alarms
• MINOR: Forward critical, major, and minor
alarm
• WARNING: Forward critical, major, minor, and
warning alarms
• NONE: Do not forward alarms.

• AlarmMatchRE = <a valid RE> this regular expression is matched


against the alarm text. If it matches then the alarm is forwarded.

• Acknowledgments = <YES or NO> If yes the remote device is


expected to send a message after each alarm containing the string
ACK=n where n is the ACK Number sent in the alarm. If no

Alarm Forwarder Page 3(10)


TMSL 197-46600-01 Issue 1: Sep 99

acknowledgment is received within <AckTimeout> seconds the socket


will be shutdown and reopened.

• RetryIntervalOnFailedsocket =<0-32000> a timeout in milliseconds


that the Alarm Forward will delay for in between connection attempts
to the remote socket.

• AckTimeout =<1-300> a timeout in seconds such that if no


acknowledgment is received then the remote socket will be shutdown
and restarted.

• AlarmBufferSize =<0-2000> the number of alarm that will be buffered


and re-sent to the remote socket if a failure occurs.
The SimpleAlarmForwarder service will try to connect to the destination address specified in the
configuration file. If this fails it will retry to connection every 15 seconds (or
RetryIntervalOnFailedsocket value). Once a connection has been established incoming alarms will
be compared to the specified criteria, and if matching they will be forwarded as text over the socket.
If the socket fails, the retry mode will be re-entered. Alarms will be buffered up to the number
specified by AlarmBufferSize value when the remote socket is in failure, or the remote end does not
acknowledge an alarm.
When Acknowledgments is set to YES, the SimpleAlarmForwarder expects the remote socket to
send a message back to over the socket, containing the ACK Number specified in the original alarm
message. No more alarms will be sent until an ACK is received. Instead they will be buffered and
sent after the ACK is received. If no ACK is received within AckTimeout second of the alarm being
sent, the socket will be shutdown, then reopened.

DN=<NMS DistinguishedName>,ACK=<n><CR><LF>>
<Alarm Text>
eg.
DN=DCD1,ACK=1

TELECOM 2000-01-03 01:24:52


A 217 REPT EVT EQPT
"CLK-2:LOCKED,SC,2000-01-03,01-24-52:/* CLOCK CONVERGED ON
REFERENCE INPUT */"
;

Figure 2 Forwarded Alarm Format

Page 4(10) Alarm Forwarder


Issue 1: Sep 99 TMSL 197-46600-01

ACK=<n>
eg.
ACK=1

Figure 3 Ack message format

The alarm text may contain white space before first line, depending on the text that was received
from the ME.

Regular Expression Format


The regular expression (RE) is constructed as follows:
The following rules (1.1-1.5) determine one-character REs that match a single char-
acter:

1.1 Any character that is not a special character (to be defined) matches itself.

1.2 A backslash (\) followed by any special character matches the literal character itself.
i.e., "escapes" the special character.

1.3 The "special characters" are:


+ * ? . [ ] ^ $

1.4 The period (.) matches any character except the newline. e.g., ".umpty" matches
either "Humpty" or "Dumpty."

1.5 A set of characters enclosed in brackets ([]) is a one-character RE that matches any of
the characters in that set. E.g., "[akm]" matches either an "a", "k", or "m". A range of
characters can be indicated with a dash. E.g., "[a-z]" matches any lower-case letter.
However, if the first character of the set is the caret (^), then the RE matches any char-
acter except those in the set. It does not match the empty string. Example: [^akm]
matches any character except "a", "k", or "m". The caret loses its special meaning if it
is not the first character of the set.

Alarm Forwarder Page 5(10)


TMSL 197-46600-01 Issue 1: Sep 99

The following rules (2.2-2.4) can be used to build a multicharacter RE:

2.1 A one-character RE followed by an asterisk (*) matches zero or more occurrences of


the RE. Hence, [a-z]* matches zero or more lower-case characters.

2.2 A one-character RE followed by a plus (+) matches one or more occurrences of the
RE. Hence, [a-z]+ matches one or more lower-case characters.

2.3 A question mark (?) is an optional element. The proceeding RE can occur zero or once
in the string - no more. e.g. xy?z matches either xyz or xz.

2.4 The concatenation of REs is a RE that matches the corresponding concatenation of


strings. e.g., [A-Z][a-z]* matches any capitalized word.

Finally, rules 3.1 and 3.2 show how the entire regular expression can be anchored to
match only the beginning or end of a line:

3.1 If the caret (^) is at the beginning of the RE, then the matched string must be at the
beginning of a line.

3.2 If the dollar sign ($) is at the end of the RE, then the matched string must be at the end
of the line.
The following escape codes can be used to match control characters:

\b backspace
\e ESC (escape)
\f formfeed
\n newline
\r carriage return
\t tab
\xddd the literal hex number 0xdd
\ddd the literal octal number ddd
\^C Control code. e.g. \^D is "control-D"

Page 6(10) Alarm Forwarder


Issue 1: Sep 99 TMSL 197-46600-01

Supervised Processes files


Figure 4 (page 8) shows a example of the SupervisedProcesses.txt file which can be found in the
$MONITORHOME/configs directory. Inserting the last line will cause start the
SimpleAlarmForwarder to be started when the supervised processes are restarted.

IS
FM_SERVER
HB_SERVER
TSERVER
TSCV5 UI
SimpleAlarmForwarder

Figure 4 SupervisedProcesses.txt example

Alarm Forwarder Page 7(10)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Index

Symbols

$ ...................................................................................................................................................... 6
* ....................................................................................................................................................... 6
+ ...................................................................................................................................................... 6
. ....................................................................................................................................................... 5
? ...................................................................................................................................................... 6
\ ....................................................................................................................................................... 5
\^C .................................................................................................................................................. 6
\b ..................................................................................................................................................... 6
\ddd ................................................................................................................................................ 6
\e ..................................................................................................................................................... 6
\f ...................................................................................................................................................... 6
\n ..................................................................................................................................................... 6
\r ...................................................................................................................................................... 6
\t ...................................................................................................................................................... 6
\xddd .............................................................................................................................................. 6
^ ...................................................................................................................................................... 6

Acknowledgments Parameter .............................................................................................. 3


AckTimeout Parameter ........................................................................................................... 4
AlarmBufferSize Parameter .................................................................................................. 4
AlarmMatchRE Parameter ..................................................................................................... 3
Alarms
-Acknowledging ........................................................................................................ 4
-Buffering ..................................................................................................................... 4
-Comparing ................................................................................................................. 4
-Matching .................................................................................................................... 4

Configuration File
-Default ........................................................................................................................ 3
-Parameters ............................................................................................................... 3
Connecting .................................................................................................................................. 4

DestinationAdresss Parameter ............................................................................................ 3

Escape Codes ............................................................................................................................ 6

Page 8(10) Alarm Forwarder


Issue 1: Sep 99 TMSL 197-46600-01

Parameter
-Acknowledgments .................................................................................................. 3
-AckTimeout ............................................................................................................... 4
-AlarmBufferSize ...................................................................................................... 4
-AlarmMatchRE ........................................................................................................ 3
-DestinationAdresss ................................................................................................ 3
-RetryIntervalOnFailedsocket .............................................................................. 4
-SeverityFilter ............................................................................................................ 3

RE: see Regular Expression Format


Regular Expression Format .................................................................................................. 5
RetryIntervalOnFailedsocket Parameter .......................................................................... 4

SeverityFilter Parameter ........................................................................................................ 3


Socket Shutdown ...................................................................................................................... 4
Special Characters ................................................................................................................... 5
Start-Up ........................................................................................................................................ 3
String Concatenation ............................................................................................................... 6

Supervised Processes files ................................................................................................... 7

Alarm Forwarder Page 9(10)


TMSL 197-46600-01 Issue 1: Sep 99

(This page intentionally left blank)

Page 10(10) Alarm Forwarder


Issue 1: Sep 99 TMSL 197-46600-01

Process Supervisor Server and


Process Supervisor User Interface
The Process Supervisor is a server application which looks after processes
specified by you. A process is something which the operating system can run. It is
also known as a programme or executable file. At startup the Process Supervisor
will start up any processes which are stored within the ini file: PSFiles.ini.

The Process Supervisor User Interface (UI) allows you to view the processes which
are being supervised. You will be unable to view processes for which you do not
have read access, as defined by the NMS Security Manager application.

Why Would I Use The Process Supervisor Applications?

With these programmes you can monitor the CPU usage of each supervised
process and set a maximum memory usage for it. All supervised processes are
continually checked to see if they have crashed or are leaking memory. If so, they
will be restarted automatically1.

What Else Would I Need To Use The Process Supervisor Applications?

To run the Process Supervisor, you will need to be running either Windows NT or
Unix.

The Process Supervisor’s supervised processes can only be manipulated via


requests from the Process Supervisor UI. Only one Process Supervisor UI can be
connected to the Process Supervisor server at a time.

The Process Supervisor UI is a client application which allows you to manipulate


the running of processes via a connection to the server application Process
Supervisor. You can stop a process, start a process, restart a process, stop all
processes, start all processes, remove a process and change the set memory
usage value for a process.

(1) Processes that crash frequently will have a 15 second delay before restarting. Other processes will restart
immediately.

.
Process Supervisor Page 1(20)
TMSL 197-46600-01 Issue 1: Sep 99

Chapter Contents
Opening the Process Supervisor Application ...................................... 3
Opening The Process Supervisor UI ................................................... 4
The Process Supervisor UI Toolbar ..................................................... 6
The Process Record ............................................................................. 8
Sorting Process Records ...................................................................... 8
Adding A Process ................................................................................ 9
Changing The Properties Of A Process ............................................. 11
Stopping A Supervised Process ......................................................... 12
Starting A Supervised Process........................................................... 13
Restarting A Supervised Process ....................................................... 13
Removing A Process From The Supervised List ............................... 13
Starting All Of The Supervised Processes ......................................... 13
Stopping All Of The Supervised Processes ....................................... 14
Shutting Down The Process Supervisor UI ....................................... 14
Print Previewing The Contents Of The
Process Supervisor Main Window .................................................... 14
Printing A List Of Supervised Processes............................................ 14
Constructing And Adding To The PSFile.ini .................................... 14
Frequently Asked Questions... ........................................................... 16
Chapter Index .................................................................................... 17

Page 2(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Opening the Process Supervisor Application


Windows NT or UNIX
To start the Process Supervisor, type the path and file name on the command line (found in the Run
item of the Start menu of Windows NT).
Windows NT only
You could also double click the Process Supervisor item within Windows NT Explorer, or select
the Process Supervisor icon from the Windows NT Start menu.
Unix only
In Unix, you could double click on the Process Supervisor item in the NMS Admin menu on the Unix
CDE Front Panel (Figure 1).
On startup the Process Supervisor will ensure that you have the appropriate security key and
security access level before continuing. It will also start any processes contained within the file
PSFiles.ini.
If startup has been successful and you are using a Windows NT, the application will appear in
Windows Task Manager as ProcSup.exe, and a terminal style window will be displayed.
If you are using Unix, a flashing cursor will be shown within the terminal window from which the
programme was started.

Figure 1 The Unix CDE Front Panel / Windows Front Panel

Process Supervisor Page 3(20)


TMSL 197-46600-01 Issue 1: Sep 99

Opening The Process Supervisor UI


Windows NT or UNIX
To start the Process Supervisor UI, type its path on the command line, (found in the Run item on
the Start menu of Windows NT). You will also need to supply the address of the Process Supervisor
server application. The syntax for this is as follows:
Application path and name -sv Server Name
or
Application path and name -sv IP Address
e.g. If the application needs to connect to Process Supervisor located on a server known as
embersoft1, the command line instruction would read as follows
PSUI -sv embersoft1.
If no address is supplied, the local machine will be checked for the Process Supervisor application.
Another (optional) flag can also be used within the command line. This will load non-English
versions of the application. To do this, type in the name and server address, as shown above,
followed by -nls and the name of the translation file you have been supplied with.
e.g. To expand the example given above to include translation files. The translation file is called
language.nls:
PSUI -sv embersoft1 -nls language.nls

Page 4(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

On startup, the Process Supervisor UI will first check your level of user access with the related
Security System. There are three levels of access possible, shown in the following table:

Security Level Access Rights

No Access Unable to run the program


Read Access Able to run programme and scan process details, but not to
send requests to the server
Full Access Able to run the program, scan process details, and send
requests to the server

Press the OK button and the following window will be shown:

Figure 2 Process Supervisor UI Application Main Screen

If the server is supervising any processes at the time you started up the application, they will be
shown in the main window (see Figure 2). If no processes are currently being supervised, the
window will be empty.

Process Supervisor Page 5(20)


TMSL 197-46600-01 Issue 1: Sep 99

Failure On Startup

If the server name or IP address you have defined cannot be found, a message box will be
displayed saying Server Name Specified Not Found. The program will exit when the
OK button is pressed.
If the Process Supervisor UI has failed to connect to the server a message box will be
displayed saying: Your Connection Has Been Unsuccessful.
If another instance of the Process Supervisor UI is already connected to the Process
Supervisor than a message box will be shown saying: Connection Unsuccessful: Client
Already Exists.
Security Manager and Security Key failure error messages will also be shown.

The Process Supervisor UI Toolbar


Below are the tool bar item titles, with a reference to where further information can be found:

Start All Processes Tool

This will be discussed later. See “Starting All Of The Supervised Processes” on page 13.

Stop All Processes Tool

This will be discussed later. See “Stopping All Of The Supervised Processes” on page 14.

Restart Process Tool

This will be discussed later. See “Restarting A Supervised Process” on page 13..

Start Selected Process Tool

This will be discussed later. See “Starting A Supervised Process” on page 13..

Stop Selected Process Tool

This will be discussed later. See “Stopping A Supervised Process” on page 12.

Page 6(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Remove Selected Process Tool

This will be discussed later. See “Removing A Process From The Supervised List” on
page 13.

Add Process Tool

This will be discussed later. See “Adding A Process” on page 9.

Print Tool

This tool will print out a hardcopy version of the list of currently supervised processes.

Print Preview Tool

This tool will display on screen the appearance of a printout.

Process Supervisor Page 7(20)


TMSL 197-46600-01 Issue 1: Sep 99

The Process Record


Each process record contains the following information about a process:

Process ID

This is a unique number allocated by the operating system to each process

Process Name

The name of the process entered by you in the Add Process dialogue box (see Figure 3)

CPU Usage

A percentage of the totally available processing power that is currently being used by the
process.

Memory Usage

The average amount of physical memory used by the process. It is an averaged out from
the time the process was last started until the present time. Therefore the longer a process
has been running, the more accurate this value is. Expressed in kilobytes.

State

This shows whether the process is currently running and if so, when it was started. If the
process is currently stopped, it shows when it was terminated.

Restarts

This shows the total number of restarts made by this programme, either since it was
registered by the Process Supervisor or since the Restart value was last set to zero.

Sorting Process Records


The process records can be sorted by any column (alphabetically A-Z or numerically in ascending
order) by clicking in the column header (where the column title is).

Page 8(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Adding A Process
Either select the Add Process item from the Process menu or click on the Add Process icon in
the toolbar. The Add Process dialogue will be displayed.

Figure 3 The Add Process Dialogue

Fill in either the name or address of the process in the top text box. If the full path is not known, you
can press the Browse button and find the file using standard Open File box. Use this to find the
process you wish to monitor. The name of the selected process will automatically be written to the
edit box once you have pressed the Open button.
If the selected process has any required parameters, these can be inserted within the Command
Line Parameters box.

Process Supervisor Page 9(20)


TMSL 197-46600-01 Issue 1: Sep 99

Setting The Set Memory Usage Limit When Adding A Process

To set a limit for the amount of memory the process can use, click in the Monitor
Memory tick box. You will now be able to insert a value, in kilobytes, in the Maximum
Memory Usage Allowed box.
Clicking again in the Monitor Memory tick box will remove the tick, and stop memory
use being monitored.
Any non-numeric entries within the Maximum Memory Usage Allowed box will also
prevent the memory use of the process being monitored.
Any values set now can be changed once the Process Supervision has been set up. (See “Changing
The Properties Of A Process” on page 11.)
Press OK. If it is started successfully, the process details will be entered in the Process Supervisor
UI screen.
If the attempt to monitor the process is unsuccessful, the process details will not be added to the
main screen and a message box will appear, informing you of this. Common reasons for failure are
that a process with the same name and parameters is already being supervised, or the server has
failed to start the process.
If it was successful, an entry will be inserted in the PSFiles .ini file for the process. This will detail
its name, parameters, set memory usage value and restart value. This will be updated as necessary.
An example of this is shown in Figure 6.

Page 10(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Changing The Properties Of A Process


Once a process has entered supervision, various values can be reset. Either double click on the
process whose values you wish to change, or highlight it by single clicking on it and then select
Process Properties from the Process Menu. The Process Properties dialogue will be displayed,
showing the current set of values for this process.

Figure 4 The Process Properties Dialogue Box

Changing The Set Memory Usage Value Of A Process

The value in the Memory Usage box can be either set to zero or changed.

Resetting The Restart Count

The value in the Restart Count column can be reset to zero by clicking the Reset Restart
Count box.
If you do not wish to keep the changes that you have made in the this box, press Cancel. Otherwise
click the OK button.

Process Supervisor Page 11(20)


TMSL 197-46600-01 Issue 1: Sep 99

A Confirmation of Changes dialogue box, shown below, will be displayed.

Figure 5 Confirmation of Changes Dialogue Box

There are three options available to you:


Store Changes: This will store the changes made in the Process Supervisor ini.files and
show them in both the UI and server applications. The new details will be shown in this
session and retained for future sessions. Tick the box and click the OK button to choose
this option.
Store Changes / Restart Process: This stores the options as discussed previously. It also
restarts the process. Tick the box and click the OK button to choose this option.
Cancel Changes. Press the Cancel button to discard any changes that you have made in
the Process Properties box.

Stopping A Supervised Process


Select the process that you wish to stop by clicking on it within the main Process Supervisor UI
window. Then either choose the Stop Selected Process item from the Process menu, or click on
the Stop Supervised Process icon in the toolbar.
A message will appear asking you to confirm that you wish to stop the process. Once you have
pressed OK the chosen process will be killed and the State column will show the time that the
process was stopped.

Page 12(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Starting A Supervised Process


First select the process you wish to start by clicking on it within the list box. Then choose the Start
Selected Process item from the Process menu or click on the Start Selected Process icon in
the toolbar.
A dialogue will appear asking you to confirm that you wish to start the process. Once you have
pressed OK the chosen process will be launched.
The State column of the Process Supervisor UI main window will now show that the process is
running, and the time it was started.

Restarting A Supervised Process


Select the process you wish to re-start by clicking on it within the main Process Supervisor UI
window. Then select the Restart Selected Process menu item from the Process menu, or click on
the Restart Process icon from the toolbar.
A dialogue will appear asking you to confirm that you wish to restart the process. Press OK and the
chosen process will be restarted. This option will only be available if the process is already running.
The State column will show the time at which the process was restarted.
Once the process has been started the value in the Restarts column for the process will be increased
by one.

Removing A Process From The Supervised List


First select the process that you wish to stop monitoring in the main Process Supervisor UI window.
Then choose the Remove Process item from the Process menu or click on the Remove Process
icon in the toolbar. A message box asking you to confirm that you wish to remove the process
will be displayed.
If the process is currently running, you will also be asked whether you wish to leave it running after
removing it from supervision.
Click OK to remove the process, or Cancel to retain it. Once a process is removed, it will no longer
appear in the Process Supervisor UI window.

Starting All Of The Supervised Processes


To do this, either select the Process menu at the top of the Process Supervisor UI and then choose
the Start All Processes item or click on the Start All Supervised Processes toolbar button .
A message box will appear asking you to confirm that you wish to start all of the processes. To
continue, press OK, otherwise press Cancel.

Process Supervisor Page 13(20)


TMSL 197-46600-01 Issue 1: Sep 99

All processes currently stopped will be started. Any running processes will be restarted. The State
Column of the Process Supervisor UI list box will now show the time at which the processes were
started / restarted.
The restart count of all the processes will be increased by one.

Stopping All Of The Supervised Processes


To do this, select the Stop All Processes item from the Process menu or click on the Stop All
Processes toolbar button .
A message box will appear asking you to verify that you wish to stop all of the processes. To
continue press OK. All processes that are running will now be stopped. The State Column of the
Process Supervisor UI main window will now show the time at which the processes were stopped.

Shutting Down The Process Supervisor UI


The Process Supervisor UI can be closed either by selecting the Exit option from the Window
Menu or by clicking on the X in the right hand corner of the main window.

Print Previewing The Contents Of The Process Supervisor


Main Window
To print preview the contents of the Process Supervisor UI main window, either select the Print
Preview item from the Window menu or the Print Preview icon from the toolbar. A print
preview window will be displayed, enabling you to see how the contents of the window would look
if printed out. Press Close to return to the Process Supervisor UI window.

Printing A List Of Supervised Processes


To print the contents of the Process Supervisor UI main window, either select the Print item from
the Window menu or the Print icon from the toolbar. A standard Print Setup dialogue box
will be displayed. Here you can set the number of copies, select a printer from those available, and
change the page settings. When you have made your selections, press OK to continue printing.

Constructing And Adding To The PSFile.ini


This action is not recommended unless it is absolutely essential, as making incorrect modifications
to your system files could have unpredictable results.

Page 14(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

You should not need to alter the .ini file as adding a process will enter an entry to it and removing
a process will delete an entry from it. However if you do choose to do this, it is vital to remember
the following points:
• Do not leave spaces within the section names of the entries or between
the section headings and set values.

• Include a # before the next entry number if adding an entry to the file
manually.
IMPORTANT: Always keep the numbers in order if you have to
do this.

• Note that any duplicate entries within the ini file will be ignored.
.

Figure 6 PSFiles.ini editing window

Process Supervisor Page 15(20)


TMSL 197-46600-01 Issue 1: Sep 99

Frequently Asked Questions...

1 Q. What has happened when I get the error ‘Error ini file
Constructed Incorrectly’?
A. The Process Supervisor has had a problem with reading the PSFiles.ini. The file
may have been amended manually and there may be headings missing or
spaces included. Both of these problems will stop the Process Supervisor
reading the file properly.

The solution is to exist the Process Supervisor applications and amend the ini
file so that:

• there are no spaces in any of the section names


• the numbers all follow on from each other with a hash in front
• there are no spaces between the = signs of the heading names and their values.

When you’ve done this the Process Supervisor will be able to read the
PSFiles.ini file.

2 Q. Why did nothing happen when I requested an action on a


process?
A. The socket used to send to the Process Supervisor UI is also used for sending
new data to the screen. A result of this is that, occasionally, messages may
collide and not reach the Process Supervisor. Simply repeat the request for an
action.

3 Q. Why did the Process Supervisor not add the process I


requested?
A. A process is not added under the following circumstances:

• It is already being supervised.


• Process Supervisor fails to start the process. Repeat the request to start the process.
• The process cannot be found at the location you have specified. Recheck the location
in the Add process dialogue box.

Check each of the points listed above. If the process still does not get added,
there may have been a collision between messages within the socket, so try
resending the request.

Page 16(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Chapter Index

Symbols

.ini File ........................................................................................................................................ 10

Access Levels ............................................................................................................................ 5


Add Process Dialogue ............................................................................................................ 9

Confirmation of Changes Dialogue Box .......................................................................... 12


CPU Usage ................................................................................................................................. 8
Customizing the Network Browser ................................................................................... 15

Exiting ......................................................................................................................................... 14

Frequently Asked Questions............................................................................................... 16

ID .................................................................................................................................................... 8

Memory Usage .......................................................................................................................... 8


Memory Usage Limit
-Changing .................................................................................................................. 11
-Removing ................................................................................................................ 10
-Setting ...................................................................................................................... 10

Name ............................................................................................................................................. 8

Print ............................................................................................................................................... 14
Print Preview ............................................................................................................................ 14

Process Supervisor Page 17(20)


TMSL 197-46600-01 Issue 1: Sep 99

Process
-Adding ........................................................................................................................ 9
-Adding to .ini file .................................................................................................... 10
-Changing Properties Of ....................................................................................... 11
-Command Line Parameters ................................................................................ 9
-Failure Adding ........................................................................................................ 10
-Removing ................................................................................................................ 13
-Restarting ................................................................................................................ 13
-Setting Memory Limit........................................................................................... 10
-Starting ..................................................................................................................... 13
-Starting All ............................................................................................................... 13
-Stopping ................................................................................................................... 12
-Stopping All............................................................................................................. 14
Process Properties Dialogue Box ......................................................................................11
Process Record
- ID ................................................................................................................................. 8
-CPU Usage ............................................................................................................... 8
-Defined ....................................................................................................................... 8
-Memory Usage ........................................................................................................ 8
-Name .......................................................................................................................... 8
-Restarts ...................................................................................................................... 8
-Sorting ........................................................................................................................ 8
-State ............................................................................................................................ 8
Process Supervisor
-Main Window............................................................................................................ 3
-Opening...................................................................................................................... 3
-Specifying Server ................................................................................................... 4
Process Supervisor UI
-Opening...................................................................................................................... 4
-Startup Failure ......................................................................................................... 6
-Translation ................................................................................................................ 4
Properties
-Cancelling Changes............................................................................................. 12
-Changing .................................................................................................................. 11
-Storing Changes ................................................................................................... 12
PSFile
-Amending ................................................................................................................ 15
-Editing Directly ....................................................................................................... 15
-Error Reading ......................................................................................................... 16

Removing Process ................................................................................................................. 13


Restart Count, changing .......................................................................................................11
Restarting Process ................................................................................................................. 13
Restarts ........................................................................................................................................ 8

Security Key ............................................................................................................................... 3


Shutting Down Process Supervisor UI ............................................................................ 14
Sorting Process Records ....................................................................................................... 8
Starting All Processes ........................................................................................................... 13
Starting A Process .................................................................................................................. 13
State .............................................................................................................................................. 8

Page 18(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Stopping All Processes ......................................................................................................... 14


Stopping A Process ............................................................................................................... 12

Tool
-Add Process ............................................................................................................. 7
-Print ............................................................................................................................. 7
-Print Preview ............................................................................................................ 7
-Remove Selected Process .................................................................................. 7
-Restart Process ....................................................................................................... 6
-Start All Processes ................................................................................................. 6
-Start Selected Process ......................................................................................... 6
-Stop All Processes ................................................................................................. 6
-Stop Selected Process ......................................................................................... 6
Toolbar ......................................................................................................................................... 6

Process Supervisor Page 19(20)


TMSL 197-46600-01 Issue 1: Sep 99

(This page intentionally left blank)

Page 20(20) Process Supervisor


Issue 1: Sep 99 TMSL 197-46600-01

Database Administration

This document gives advice on the basic procedures needed to keep your NMS
System working efficiently and securely. The two main steps that we shall examine
are the archiving and purging of records from the database.

In addition to the information contained here, you may need access to the set of
help manuals that were provided with your database system.

What’s in this chapter?


This User Guide chapter contains basic information about possible maintenance
schedules, checking the status of your database and archiving records. If you need
to use the chapter as a quick reference guide, there is a keyword index at the end.

Why Would I Need To Backup The Database?


It is common practice to backup a database. Not only can hardware / software
failure cause data to be lost, but data can be accidentally deleted, wrongly added
or corrupted. When you make an organised backup up plan, you are guarding
against loss of data, and ensuring that in the event of a major machine disaster to
both your database and network you can quickly reconfigure all your elements in a
combination that you know has been stable in the past. You are also able to delete
records from the active database to keep it working efficiently.

nb. There are very different methods used to maintain the Windows NT and Unix
versions of the NMS / Timescan systems. Make sure that you read the appropriate
part of this user guide for your setup.

Database Administration Page 1(20)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Contents

Maintenance Schedule ......................................................................... 3


Non-Routine Backup Of Archives ...................................................... 5
Organisation Of Archives .................................................................... 5
Backing Up The Database ................................................................... 6
Removing Log Records ....................................................................... 8
Using ArchiveAlarms for the first time in Unix .................................. 8
Starting ArchiveAlarms In Unix ....................................................... 10
Starting ArchiveAlarms In Windows NT ......................................... 10
Using Archive Alarms ....................................................................... 11
Restoring Database Records From Previously Saved Sets ................ 12
Frequently Asked Questions............................................................... 16
Notes For Administrators .................................................................. 18
Chapter Index .................................................................................... 19

Page 2(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

Maintenance Schedule
The TimeScan/NMS system collects notifications from various Managed Elements (e.g. DCDs),
inserts them into a database and allows you to view the information contained in them in various
ways. Over a relatively short period of time, the normal use of this system will generate many
records in the database. A regular maintenance schedule will ensure the continued high
performance of your system. The tables below outline a possible maintenance plan, but there are
also other times at which you should backup your system, shown in the “Non-Routine Backup of
Archives” section.

Table 1: Weekly Schedule

Action Type User

Backup database Full (Level 0 if Informix) Administrator

Unix / Informix only: If using the Unix / Informix based Timescan / NMS system, it is also
recommended that you perform more frequent Level 1 or Level 2 backups if your database logs
many records. A typical schedule would be to perform a Level 1 backup daily (for a very busy
system) or half weekly (for a moderately busy system). The purpose of Level 1 backups is to
minimise the time taken to restore the system completely.

Action Type User

Backup database Incremental (Level 1 or 2 if Administrator


Informix)

You can only perform a Level 1 archive if your previous archive was a Level 0.
You can only perform a Level 2 archive if your previous archive was a Level 1.
If you are in any doubt about which level of archive, perform a Level 0 one. It may take a little
longer, but you will be assured of maintaining all the required information.
End of Unix / Informix only information

Table 2: Monthly Schedule

Action Type User

Archive Log records Delete Log records, up to end Administrator


of LAST month

The suggested schedule outlined above may not be suitable for your system, as this will depend on
individual circumstances. The two main attributes to consider when planning a maintenance
schedule are the number of Managed Elements (MEs) and the number of notifications raised by

Database Administration Page 3(20)


TMSL 197-46600-01 Issue 1: Sep 99

each ME. Even if there are only a few MEs, if they raise many alarms, you will need to perform
housekeeping activities more frequently than if you have a larger, but less active, system.
As a very rough guideline, performance will start to deteriorate once the following sizes are
reached:
• Windows / Access- about 10 MB total database size, or approximately
10 000 alarm records.
• Unix / Informix- This largely depends on your hardware setup.
Contact your vendor for details.
At this point you should definitely start removing records from the database. This should be done
as soon as you have performed a backup.
To find how large your current database is, take the following steps:
Unix / Informix
• Use the ON-Monitor facility to find out how large your database is. To
start ON-Monitor, type the command onmonitor at the command
prompt. You will then enter the ON-Monitor tabbed screen.
• The first tab page is titled Status. One of the items on this page is
called Spaces. Use the arrow keys to move to this item. Press Return.
• You will now be presented with information about the size of various
database files.

Page 4(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

Windows / Access
• Find your current Access database file (*.mde).
• Right click on it and a popup menu will appear.
• Select the Properties item from this menu.
• The file size will be shown in the resulting information box.
Use the information gained to decide whether or not you need to remove some of the records in the
database. If you do, see the section “Removing Log Records” on page 8.

Non-Routine Backup Of Archives


As well as backing up your system on a regular basis, there are other events which should prompt
you to think about performing an additional backup.
• Changes have been made to the Timescan / NMS system with the
MOC (Managed Object Configuration) programme.

Organisation Of Archives
It is recommended that you give some thought to organisation of your archived data, and ensure that
it meets at least the following criteria:
• The saved data sets are copied from the disk on which they are
originally saved and stored elsewhere.
• The most recent complete archive (Level 0, if in Informix) from which
a successful restore has been made are kept, until it is superseded.
• Unix / Informix only: Any Level 1 or Level 2 archives subsequent the
archive outlined above are also kept until they are superseded.

Database Administration Page 5(20)


TMSL 197-46600-01 Issue 1: Sep 99

Backing Up The Database


Backing up your database should be done regularly, and as part of a routine. The better planned your
system of backing up, the more likely you are to survive a (computer) disaster without significant
loss of data. Ideally, the media containing the backup information (disks or tapes) should be stored
in a physically separate location to the current database.

Unix / Informix

There are many different levels of backup to choose from with an Informix database, and
the options chosen are largely up to you. The frequency and type of the backups will
largely depend on the activity that takes place in your database, but a suggested plan for
routine backups is given in the section “Maintenance Schedule”, on page 3.
At the very least, you will need to perform regular Level 0 backups to provide a snapshot
of the database structure and its records.
Level 1 and Level 2 backups are smaller, incremental backups which will speed up the data
restoration process. These are optional, but recommended if you have a very active
database.
For more information on creating a backup schedule, see Section 1 of the “Backup and
Restore Guide for Informix Dynamic Server”, one of the documents that came with your
Informix database.
Outlined in this document is how to backup an Informix database using the ontape
facility. This is quite straightforward, and despite the name, can be used to backup data to
a disk drive.

To backup your Unix / Informix database, take the following steps:

• log on as user informix


• type
• ontape -s.
• This performs an archive on the complete system managed by
Informix.
• You will be prompted to enter the level of the archive that you would
like to perform. As a default value, enter 0.
• The following message will appear:
• Please mount tape [number] on [file name] and
press Return
• The default files for archiving data are preset in the onconfig.* file.
Whilst there is a file in that location, that is where the archived data
will be sent.
• Press Return. The message:
• Program over
will appear when the archiving is completed.
• Now you need to move the archived data to another location. This file
(../informix/backupdata/NMS.backup) is the default value for all

Page 6(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

archives, so to prevent it from being overwritten, and to keep track of


all of your archives, immediately rename it using the following
command:
• mv NMS.backup archivedate
For example, if you perform an archive on 31 March 1999, the
command will be as follows:
• mv NMS.backup archive310399.backup
• Finally, recreate an empty file with the correct permissions to receive
the next set of archived data. Type the following commands:
• touch NMS.backup
• chown informix:informix NMS.backup
• chmod 660 NMS.backup
• chgrp informix NMS.backup
• Once you have performed a backup, you are ready to delete records
from the database (see page 8).
n.b. This will NOT purge records from the database- to do this you need to use the Alarm
Archive programme, as described on page 10.

To backup your Windows / Access database, take the following


steps:

• Find the current database file (rmdata.mde), whose default location is


net-monitor/db/data and right click on it.
• A popup menu will appear. Select the Copy item from this menu.
• Move to the chosen backup location, and Paste the file into new
position (from the right click menu.
• Rename the file, preferably including the date of backup in the new
title.
• Now move this file to a different physical location to the active
database.
Once you have performed a backup, you are ready to delete records from the database (see
page 8).

Database Administration Page 7(20)


TMSL 197-46600-01 Issue 1: Sep 99

Removing Log Records


To maintain your database at a reasonable size (see page 4 for sizing information), you will need to
periodically remove some records from the active database and store them elsewhere. If you make
backups, these can act as storage for cleared out records. If necessary you could recreate the
database at a particular point in time from these backups. (The exactness with which you can
recreate the file for a particular point in time depends on how often backups are performed on your
system.)
For the Timescan / NMS database, it may be a sensible choice to archive Log (no longer active,
usually cleared) records whose initial Date is over three months ago. (In the alarmlog table on the
NMS / Timescan database, these conditions are shown when the eventtime is over three months ago
and the activealarm value is 0.) Outlined below is a simple method of doing this in both the Unix
and Windows based systems.
For both systems, it is recommended that you remove records immediately after making a complete
(Level 0 in Informix) backup. Then, if necessary, you can recover records from your backup.
To remove records from either database running on you can run a special programme, called
ArchiveAlarms. This is part of the Information Server (IS) programme.

Using ArchiveAlarms for the first time in Unix

***IMPORTANT*** FIRST TIME USE****BEFORE USING ARCHIVE ALARMS


(UNIX) FOR THE FIRST TIME YOU MUST TAKE THE FOLLOWING STEPS (1, 2,
3) TO CREATE A BACKUP DATABASE.

There are three steps to creating a backup database:

1. Create a backup dbspace.


2. Create a backup database in the backup dbspace.
3. Create a table in the backup database.

Each will be discussed in more detail below.

Page 8(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

1. Create A Backup dbspace

THIS SHOULD BE LOCATED ON A PHYSICALLY SEPERATE DISK


TO YOUR CURRENT DATABASE. Then you will preserve your archived
data in the event of (for example) a flood or a fire in your building. Create the
backup database by typing the following command in a terminal. You should
be logged on a user: informix.

• Make the space in the file structure by creating a file called


nmsarchivedbspace.dat (not directory) in Unix, and ensuring that is
has the correct set of permissions. To do this, log on as informix and
type the following commands. Replace pathname with your chosen
backup location.
• cd pathname
• touch nmsarchivedbspace.dat
• chmod 660 nmsarchivedbspace.dat
• chgrp informix nmsarchivedbspace.dat
• Make the space into a dbspace recognised by Informix by typing the
following command (all on one line):
• onspaces -c -d nmsarchivebspace -p /pathname
nmsarchivedbspace.dat -o 0 -s 10000
• You should now see a message telling you that dbspace creation was
successful. Failure to create the dbspace is usually down to one of two
reasons:
• The space already exists. Proceed with no further
action.
• The file does not contain the correct read / write
permissions, or does not exist. Change them by
going through the steps listed at the beginning of
this section “Create A Backup dbspsace”.
2. Create A Backup Database

Create the database NMSArchive for backup records as follows. Ensure you
are logged on as user: informix.

• Open the dbaccess programme by typing dbaccess in a terminal


window.
• Use the arrow keys to move along to the Database item in the menu
along the top of the window. Press Return.
• Use the arrow keys to move along to the Create item in the new menu.
Press Return.
• Type in NMSArchive as the name for the new database. Press Return.
• The next menu will have the item Dbspace highlighted. (If not, use the
arrow keys to move to this item.) Press Return.
• From the list of dbspaces, use the arrow keys to move to the one that
you created in the first step, Create a Backup dbspace”. Press Return.

Database Administration Page 9(20)


TMSL 197-46600-01 Issue 1: Sep 99

• Move to the Logs item, using the arrow keys. Press Return.
• Select Unbuffered Logging from the list of Logging options. Press
Return.
• Move along to the Exit item in the Create Database menu. Press
Return.
• The Create-New-Database item will automatically be selected. (If
not, use the arrow keys to move to it.) Press Return.
3. Create a table in the backup database

If you are not continuing directly from the last step, ensure that you are
logged on as user: informix. Then follow the steps below.

• Type dbaccess.
• Use the arrow keys to select the Database item. Press Return.
• Use the arrow keys to move to the Select item. Press Return.
• Use the arrow keys to select the nmsarchive item. Press Return.
• Use the arrow keys to select the Exit item. Press Return.
• Use the arrow keys to select the Query-language item. Press Return.
• Use the arrow keys to select the Choose item. Press Return.
• Select the CreateAlarmLogTable item from the command files
available. (If it is not present, a full listing is available in the Notes For
Administrators section (page 18). Press Return.
• Use the arrow keys to move the Run item. Press Return.
• You should see a message telling you that the table has been created.
• Exit the dbaccess programme by moving along to the Exit item. Press
Return. Again, move along to the Exit item and press Return.

Your backup database will now have been created. You can now proceed
with using the ArchiveAlarms programme. ***END OF FIRST TIME USE
INFORMATION***

Starting ArchiveAlarms In Unix

Open the NMS Administrator menu on your Unix CDE Front Panel. Select the
ArchiveAlarms item, with the icon shown above. Then follow the instructions below for
“Using Archive Alarms”.

Starting ArchiveAlarms In Windows NT

A shortcut to ArchiveAlarms can be placed on the desktop, as part of the configuration of


the IS programme. Click on this icon to start the ArchiveAlarms programme. Then follow
the instructions below for “Using Archive Alarms”.

Page 10(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

Using Archive Alarms

On starting the ArchiveAlarms programme, the dialogue box shown in Figure 1 will
appear.

Figure 1 The ArchiveAlarms Main Window

Decide the cutoff point for records in your database, for example, records which are over
three months old. Type this date in the leftmost box under the legend: Archive Alarms
before: box. (The format for this is DD/MM/YYYY, e.g. the 31st January 1999 would be
typed 31/01/19999). If you put in an invalid date a box will appear to inform you of this,
and suggest a change. You can also put a time (in 24 hour format) in the box to the left of
the date box.
Once the values in these boxes are set as you wish, press the Archive button. A dialogue
box will appear, asking if you wish the archived records to be removed from the original
database. Press Yes to remove the records, or No to leave these records on the database.
Once you have answered this, the removal and / or deletion of records will begin. A
progress bar will appear at the bottom of the ArchiveAlarms Main window, which will
roughly indicate the completion of the archiving task. A Cancel button will appear in the
place of the Archive button whilst the programme is executing. Pressing this will stop the
archive and / or deletion of the specified records.
NB. This programme may take some time to execute, particularly in a Unix/Informix
environment, but it can be run as a background task, and will not prevent other database
usage.
Once the task is completed, the dialogue box will appear as below, with the central part
showing the total number of affected records. The removed records are now stored in a
database called NMSArchive.

Database Administration Page 11(20)


TMSL 197-46600-01 Issue 1: Sep 99

Figure 2 The ArchiveAlarms Main Window, (after archive)

Restoring Database Records From Previously Saved Sets


There are three main reasons why you might want to restore previously archived data. They are as
follows:
• Some data has been lost, due to user or computer error.
• The complete database has been corrupted.
• You wish to view sets of previously archived data.
These different circumstances require slightly different approaches. Let us look at how we can deal
with them. The Unix / Informix Instructions are immediately below and the Access / WindowsNT
instruction are on page 15.

Page 12(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

Unix / Informix

• If you wish to restore some lost data to an existing database, simply


follow the instructions for “Retrieve and Restore Data”, on page 14.
• If the complete database has been lost, you need to follow the
instructions to “Create The dbspaces” (page 13) and then those for
“Retrieve and Restore Data” on page 14.
• If you wish to view set of previously archived data then follow the
instructions in “Viewing Previously Archived Save Sets”page 15.

Create The dbspace (Unix / Informix)

To recreate the dbspace, take the following steps.

• Make the space in the file structure by creating a file called


monitordbspace.dat (not directory) in Unix, and ensuring that is has
the correct set of permissions. To do this, log on as informix and type
the following commands.
• cd ~
• cd data
• touch monitordbspace.dat
• chmod 660 monitordbspace.dat
• chgrp informix monitordbspace.dat
• Make the space into a dbspace recognised by Informix by typing the
following command (all on one line):
• onspaces -c -d monitordbspace -p
$INFORMIXDIR/data/monitordbspace.dat -o 0 -s
100000
• You should now see a message telling you that dbspace creation was
successful. Failure to create the dbspace is usually down to one of two
reasons:
• The space already exists. Proceed with no further
action.
• The file does not contain the correct read / write
permissions, or does not exist. Change them by
going through the steps listed at the beginning of
this section “Create The Dbspace”.
Once you have created the dbspace, you can move on to “Retrieve And Restore Data”.

Database Administration Page 13(20)


TMSL 197-46600-01 Issue 1: Sep 99

Retrieve and Restore Data (Unix / Informix)

To restore an existing database, you will need to have previously archived it.
When you follow the steps outlined below, you will change the records held
in the database to those held when the archive was created.

To restore a previously archived set of data, log on as informix and type the
following commands to take the database off-line and restore the database:

• onmode -k (Press Y and Return when asked if you are sure)


• ontape -r
• You will be prompted to mount a tape - assuming that you have saved
to disk as discussed here, you only need to press Return
• You will then be shown information about the dbspaces that will be
restored and asked if you wish to continue. Press Y and Return.
• You will be asked if you want to backup the logs. Press Y and Return.
• You may be offered a list of log ids and asked which is the oldest log
you wish to backup. If in doubt, enter the smallest number (for the
oldest log). Once these files are backed up, the space they use will be
freed. Press Return.
• You will be asked if you want to restore a Level 1 or Level 2 archive.
Only do this is you made a Level 1 or Level 2 archive since the Level
0 archive you are restoring. Otherwise, press n and Return.
• You will be asked if you want to Restore Log tapes. Press n and
Return.

Page 14(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

Viewing Previously Archived Save Sets (Unix / Informix)

You will now be able to view the records using the dbaccess tool. To open
this, log on as user informix and take the following steps.

• type dbaccess
• Use the arrows to select the Query-Language
item at the top of the dbaccess window. Then
press Return.
• You will be prompted to select a database. Use
the arrows to select the nmsarchive database.
This is one that the ArchiveAlarms database puts
records into.
• Use the arrows at the top of the screen to select
the New item. Then press Return.
• The cursor will have been placed in the empty
screen. Type your SQL commands here, press
Esc when you have finished editing your
command and then use the arrows to move to the
Run item at the top of the screen to execute your
SQL query.
• Example SQL: To view all of the archived alarms,
type the following command:
Select * from alarmlog
Windows / Access
• If the complete database has been lost, you need to follow the
instructions to “Restore Database From Backup” (below).
• If you wish to view sets of previously archived records then follow the
instructions in “Viewing Previously Archived Records” (below).
Viewing Previously Archived Records (Windows / Access)

The records removed from the database using the ArchiveAlarms programme
(page 10) are put into a database called NMSArchive. Simply double click on
this database to view it, then use standard Access filtering techniques to
display the required dataset.

Restore Database From Backup (Windows / Access)

To restore the complete database from a backup, first find the backup you
made following the instructions in the section “To Backup Your Windows/
Access Database”, on page 7. Double click on it to view it using Access. Once
you have decided to make it your current (active) database, then simply
rename it to “rmdata.mde”, and move it to location of your current active
database (default location: net-monitor/db/data). You can import records to
it from the NMSArchive database, again using standard Access techniques.

Database Administration Page 15(20)


TMSL 197-46600-01 Issue 1: Sep 99

Frequently Asked Questions...

1 Q. The message:

Please mount tape [number] on [file name] and press Return

is repeated when you press Return.

A. The cause of this problem is that the file to which the backup data is to be
sent has either been deleted or renamed. The solution is to move to the
pathname given (default: ../informix/backupdata) and create a new file,
by typing all of the following commands:

• touch NMS.backup
• chown informix:informix NMS.backup
• chmod 660 NMS.backup
• chgrp informix NMS.backup

2 Q. Sometimes when I use the ArchiveAlarms programme, it fails.


A. i) The most common reason for this is that the database is offline. Bring the
database back on line by logging on as user: informix and typing

• onmode -m
. Now try using ArchiveAlarms again.

A. ii) If you are deleting many thousands of records you may need to enlarge your
logical log space. This is to provide space for the transaction to be completed
before the designated high water mark is reached. Add an extra logical log first
to the monitordbspace, then try ArchiveAlarms again. If that does not work, add
an extra logical log to the nmsarchivedbspace and retry the ArchiveAlarms
programme. Add an extra logical log by logging as user: informix and typing:

• onparams -a -d dbspacename -s 10000

Replace dbspace name with either monitordbspace or nmsarchivedbspace.

3 Q. How do I change the informix password on UNIX?


A. i) Shutdown NMS and informix.Use the admintool to change the password for
the informix unix user. The user name and password that NMS uses to log on
to the database are set using the following environment variables:
RWUserName=informix and RWPassword=informix. These variable must to
updated to reflect the new password/user. They are normally setup in the
following files $MONITORHOME/configs/setupNMS.dt, $MONITORHOME/

Page 16(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

configs/setupNMS.profile, and $MONITORHOME/configs/setupNMS.csh.


These files must all be updated with the new password. Restarting NMS should
or re-booting the workstation will cause the scripts to e re-executed.

Database Administration Page 17(20)


TMSL 197-46600-01 Issue 1: Sep 99

Notes For Administrators


Full SQL listing to add alarm log table to nmsarchive database.
CREATE TABLE alarmlog (
recordid INTEGER,
distinguishedname VARCHAR (50,0),
eventtime DATETIME YEAR TO FRACTION(3),
receptiontime DATETIME YEAR TO FRACTION (3),
event SMALLINT,
recordtype INTEGER,
perceiviedseverity INTEGER,
pstext VARCHAR (9,0),
alarmid INTEGER,
slogan VARCHAR (80,0),
alarmnumber INTEGER,
likelyorigin VARCHAR (50,0),
sid VARCHAR (50,0),
printouttext VARCHAR (255),
cleartime DATETIME YEAR TO FRACTION (3),
cleartype INTEGER,
cleartext VARCHAR (255),
acknowledge SMALLINT,
acknowledgetime DATETIME YEAR TO FRACTION (3),
activealarm SMALLINT,
originalps INTEGER,
originalpstext VARCHAR (9,0),
audittime DATETIME YEAR TO FRACTION(3)
)

Page 18(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

Chapter Index
All trademarks are acknowledged.

Symbols

.mde ............................................................................................................................................... 5

Access
-Backup ........................................................................................................................ 7
Archive
-After Event ................................................................................................................ 5
-Levels ......................................................................................................................... 3
-Moving ........................................................................................................................ 6
-Organising ................................................................................................................. 5
-Renaming .................................................................................................................. 7
-Scheduling ................................................................................................................ 3
-Storing ........................................................................................................................ 6
ArchiveAlarms
-Failure ....................................................................................................................... 15
-First Time Use (Unix) ............................................................................................ 8
-In Unix ...................................................................................................................... 10
-In Windows NT ...................................................................................................... 10

Backup
-Access ........................................................................................................................ 7
-Informix ....................................................................................................................... 6

Configuring Using MOC ......................................................................................................... 5


Corrupted Database .............................................................................................................. 12
Create dbspace (Informix) ................................................................................................... 13
-Problems .................................................................................................................. 13

Database
-Sizing .......................................................................................................................... 4
dbspace
-Creating .................................................................................................................... 13
DCD ............................................................................................................................................... 3

Frequently Asked Questions ............................................................................................... 16

Database Administration Page 19(20)


TMSL 197-46600-01 Issue 1: Sep 99

Informix
-Backup ........................................................................................................................ 6

Level
-1 Archive .................................................................................................................... 3
-2 Archive .................................................................................................................... 3

Maintenance Schedule
-Discussed .................................................................................................................. 3
-Planning ..................................................................................................................... 3
Managed Elements .................................................................................................................. 3

Notes for Administrators ....................................................................................................... 18

ON-Monitor, using .................................................................................................................... 4


onspaces Command .............................................................................................................. 13
ontape -s command ................................................................................................................. 6

Performance Guidelines ......................................................................................................... 4

Removing Log Records .......................................................................................................... 8


Restore Database
-Access ...................................................................................................................... 15
-Informix ..................................................................................................................... 14

Sizing
-Access Database .................................................................................................... 5
-Informix Database .................................................................................................. 4
Spaces Tab ................................................................................................................................. 4
Status Tab ................................................................................................................................... 4
Storing Archives ........................................................................................................................ 6

Page 20(20) Database Administration


Issue 1: Sep 99 TMSL 197-46600-01

Fault Management
Configuration

The Fault Management Configuration Application provides a flexible utility which


enables alarms and events to be mapped to unique identities. In turn notifications
from given sources may have their perceived severities re-mapped.

What would I need to run the Fault Management


Configuration Application?
You would need to have an appropriate information server to link to.

What’s in this Chapter?


This chapter tells you all you need to know to use the features of the Fault
Management Configuration Application. There is a description of the tools
available, (page 4) and a step by step guide to using the application (starting on
page 5). If you need to use this chapter as an quick reference guide, there is a
keyword index starting on page 8.

Fault Configuration Page 1(10)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Contents
Opening the Fault Management Configuration Application ............... 3
The Fault Management Configuration Tool Bar .................................. 4
Managing Severity Mapping ............................................................... 5
Deleting an Existing Notification Mapping......................................... 7
Chapter Index ...................................................................................... 8

Page 2(10) Fault Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Opening the Fault Management Configuration Application


The Fault Management Configuration application can be found in the NMS Administrator menu,
either in the Window Start menu or the Unix CDE Front Panel (Figure 1). On start-up the system
will determine whether you have the authority to access this facility. This decision will be based on
your user identification.
If access is denied a dialogue will be displayed informing you of this.:

Figure 1 The Unix CDE Front Panel / Windows Start Menu

If access is granted the following window will be displayed:


:

Figure 2 The Fault Management Configuration User Window

Fault Configuration Page 3(10)


TMSL 197-46600-01 Issue 1: Sep 99

This is the Fault Management Configuration user window. It is composed of four columns which
illustrate the notification mapping data already defined in your system.
The Notification Code field contains the notification codes, as defined by the interface description
of the managed elements. These codes are used as keys for the mapping process.
The Identity field contains a numeric identifier which is unique for each mapping entry.
The Acknowledge To Log field shows whether the mapped notification is a revertive or non-
revertive condition. If the value is NO alarms and events will only move to the log when they are
both cleared and acknowledged. If the value is YES alarms and events will move to the log when
they are only acknowledged.
The Mapped Severity field indicates whether the perceived severity of this notification has been re-
mapped to another severity.

The Fault Management Configuration Tool Bar


On start-up the Fault Management Configuration application has a tool bar, just above the view
illustration, containing seven tools:

This tool bar is dockable so if you are not happy with its position you can pick it up with the mouse
and position it where you want around the view. If you drop it outside the window, or place it in the
centre, it will transform itself in to a fly-off window:
Let’s take a brief look at each tool...

Print Tool

Selection of the Print tool will cause a hard copy report of the current fault management
configuration to be generated.

Print Setup Tool

Selection of the Print Setup tool will allow you to control the hard copy report generation.

New Alarm Tool

The New Alarm tool allows you to create a new mapping entry. This feature will be
discussed further in the next section.

Page 4(10) Fault Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Delete Alarm Entry Tool

This tool will become active when a list entry is selected. Selection of this tool will
remove the selected mapping from the system.

Edit Alarm Entry Tool

This tool will become active when a list entry is selected. Selection of this tool will enable
you to edit the selected mapping.

Map Alarm Severities Tool

Again, this tool will become active when a list entry is selected. Selection of this tool will
enable you to edit the perceived severity re-mapping of the selected entry.

Refresh List Tool

Selection of the Refresh Tool causes the contents of the alarm re-mapping list in the main
window to be refreshed from the Fault MIB (Management Information dataBase) tables.

Managing Severity Mapping


The following section discusses both adding and editing severity mappings, as these are very
similar operations.

To add an alarm or event mappings, select the New Alarm tool. The following dialogue will be
provided for you to input the required information. To edit an alarm or event, select the Edit Alarm
Entry tool. A similar dialogue will be provided, which allows the available fields to be edited.

Figure 3 The Add Alarm Mapping Dialogue

Fault Configuration Page 5(10)


TMSL 197-46600-01 Issue 1: Sep 99

For a new mapping, the Notification Code must be entered exactly as it is specified in the interface
description of the alarm or event. The Identity is a mandatory numeric identifier, which will be
automatically generated by the application. Both the Notification Code and Identity must be unique
to the system. An attempt to enter a non unique value will result in a warning message.
If the mapped notification is revertive, i.e. has an associated clearing, the Cleared Event check box
must be checked. To set-up a re-mapping for the perceived severity for the alarm or event, select
the Map button. The following dialogue will be provided.:

Figure 4 An Empty Severity Mapping Dialogue

Multiple perceived severity re-mappings are supported from different source elements and likely
origins. All will be listed in this dialogue.
As this is new mapping, no entries exist as yet. Selecting the Add button will cause the following
configuration dialogue to appear:

Figure 5 The Add Severity Mapping Dialogue

Page 6(10) Fault Configuration


Issue 1: Sep 99 TMSL 197-46600-01

The Distinguished Name panel enables you to define the source for the perceived severity re-
mapping. With All selected, any notification carrying the matching notification code from any
source element will be re-mapped. If the re-mapping is to be specific to a single element, by
selecting the Specific control the desired source element may be selected from the list box.
The Likely Origin panel enables you to define the origin within the selected sources for the
perceived severity re-mapping. With All selected, any notification carrying the matching
notification code from any likely origin will be re-mapped. If the re-mapping is to be specific to a
single origin, by selecting the Specific control the desired origin may be defined in the edit box.
Finally the Severity panel provides a list box containing the mapped perceived severity, Critical,
Major, Minor, or Warning.
On selecting the OK button the newly created entry will appear in the Severity Mapping dialogue
list.
Note: For conflicting mapping entries the highest defined perceived severity is taken.

Deleting an Existing Notification Mapping


With a notification entry selected, press the Delete Alarm Entry tool. A confirmation dialogue will
be provided. On confirmation the entry will be deleted from the system. Great care must be
exercised when deleting mappings as there is no undo facility.

Fault Configuration Page 7(10)


TMSL 197-46600-01 Issue 1: Sep 99

Chapter Index

Access .......................................................................................................................................... 3
Alarm Entry
-Adding ........................................................................................................................ 5
-Deleting ...................................................................................................................... 7
-Editing ......................................................................................................................... 5

Cleared Event ........................................................................................................................ 4, 6

Delete Alarm Entry Tool ......................................................................................................... 5


Distinguished Name ................................................................................................................. 7

Edit Alarm Entry Tool .............................................................................................................. 5


Event Entry
-Adding ........................................................................................................................ 5
-Deleting ...................................................................................................................... 7
-Editing ......................................................................................................................... 5

Identity .......................................................................................................................................... 4

Likely Origin ................................................................................................................................ 7

Map Alarm Severities Tool .................................................................................................... 5


Mapped Severity ....................................................................................................................... 4
Monitor Administrator .............................................................................................................. 3

New Alarm Tool ......................................................................................................................... 4


Notification Code................................................................................................................... 4, 6

Page 8(10) Fault Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Perceived Severity ................................................................................................................... 7


Print Setup Tool......................................................................................................................... 4
Print Tool ..................................................................................................................................... 4

Refresh List Tool ....................................................................................................................... 5

Severity
-Multiple remapping ................................................................................................. 6
-Perceived................................................................................................................... 7
-Remapping ................................................................................................................ 6
Start-up ......................................................................................................................................... 3

Tool Bar........................................................................................................................................ 4

Fault Configuration Page 9(10)


TMSL 197-46600-01 Issue 1: Sep 99

(This page intentionally left blank)

Page 10(10) Fault Configuration


Issue 1: Sep 99 TMSL 197-46600-01

Troubleshooting

The Troubleshooting section gives information on work arounds for commonly appearing
system wide faults. Faults for specific applications can be found in the relevant User Guides.
When trying to sort out a problem, if the solutions are numbered sequentially, as in Q1, then perform
the actions outlined in the order given. If the solutions are lettered, as in Q5, choose from between
them.

Frequently Asked Questions...

1 Q. Why can’t I communicate to a DCD using X.25?


A1. If using a permanent connnection, first stop NMS Services. Then use XPAD and
windows terminal (in Accessories Program Group) to try to communicate to the
remote element. If this is successful (a TL1 command was sent and the correct
response was received) the NMS Services should be restarted. If this fails
restart the Eicon X.25 card, using commands “eccard stop” and “eccard start”
in a “command prompt” the last message from “eccard start” should be “network
connect established”,. If it returns an error, check connection to the packet
switch. If XPAD cannot connect to the DCD, the fault will probably lie in the X.25
network, or the far end. Contact your network administrator for further help.

A2. If communication is still not established, verify that the communication (X.121)
address for the specific DCD is correct.

A3. If communication is still not established, run the terminal application from the
TimeScan / NMS Administrator menu and try to connect to the ME. The
resulting error message report should indicate the fault condition.

2 Q. Why can’t I communicate to a DCD using a modem?


A1. Use Windows Terminal to try to communicate to remote element.. If Terminal
cannot connect to the modem, consult the modem installation guide. If you can
successfully dial the number but do not connect, verify that the phone number
is correct, and the DCD end modem is setup correctly.

A2. If communications still do not work, verify that the communication address
(phone number) for the specific DCD is correct.

A3. If communication is still not established, run the Terminal application from the
Timescan / NMS Administrator menu and try to connect to the ME. The resulting
error message report should indicate the fault condition.

Troubleshooting Page 1(6)


TMSL 197-46600-01 Issue 1: Sep 99

3 Q. Why can’t I communicate to DCD using RS232?


A1. If using a permanent connnection, first stop NMS Services. Then use windows
Terminal to try to communicate with the remote element. If Terminal fails to
connect you should check your cabling to the DCD.

A2. If communication is still not established, verify that the communication (com port
e.g.“COM1”) address for the specific DCD is correct.

A3. If communication is still not established run the Terminal application from the
TimeScan / NMS Administrator menu and try to connect to the ME. The
resulting error message report should indicate the fault condition.

4 Q. Why can’t I connect to the DCD using the IP address?


A1. If using a permanent connnection, first stop NMS Services. Then using Telnet,
verify that you are able to communicate with the distant device.

A2. Ensure that the IP address is not already in use.

A3. Ensure that the correct port has been correctly specified.

A4. Ensure the Terminal Server is set up correctly.

A5. If communication is still not established, run the Terminal application from the
TimeScan / Scan Administrator menu and try to connect to the ME. The
resulting error message report should indicate the fault condition.

5 Q. Programs will not start correctly. Either database corruption


or ‘no data found’ errors are reported. Why?
A. This error may have one of three causes:

a ODBC Sources. Check ODBC Sources are still present


with the correct settings.
b Database corruption. See “Repair/Compact database” on
page 5.
c Database corruption and failed repair. If step two has
failed, the database should be rolled back to a previous
state see See “Roll-back to previous database” on
page 5.

Page 2(6) Troubleshooting


Issue 1: Sep 99 TMSL 197-46600-01

6 Q. My disk appears to be full of TimeScan/NMS files. Why?


A. The two parts of the TimeScan/NMS system which will grow over a period of
time are the Temporary files, and the database files. Restarting your machine
may clear some temporary files. See also “Repair/Compact database” on page
5.

7 Q. A disk crash, or other major hardware failure has occurred


and the system installation has been corrupted. How do I
recover?
A. If the system is too badly damaged for database repair/ roll-back. the system
may need to be reinstalled from the original CD, and the database may be rolled
back. See “Reinstallation” on page 4.

8 Q. How do I recover from a system “lock up” after using all


virtual memory?
A. Restart machine. See “Restarting machine” on page 4.

9 Q. Why are alarms reported on the wrong ME?


A. It is possible to configure to ME with the same primary communications address
If this occurs, alarms report on one DCD may appear on the another with the
same address. This can apply across transport types, i.e. if, for a given ME, both
a permanent connection and modem receiver have been setup to use COM1.
The Database Administration form can be used to look at the CmMIB table and
a filter on the Communication Address field may be used to see if this is your
problem.

10 Q. Why are alarms reported to an “UNKNOWN” distinguished


name
A. The source of an alarm can be determined in a number of ways:

a A connection (permanent or transitory) is made to the ME.


All alarms on this channel are associated with the
connected ME.
b The communication source address is used and
compared to the FM address (works with X.25).
c The alarm SID is used to match the SID defined in CM
database (modems).
If all of the above fail the alarm in raised against an “UNKNOWN” distinguished name.
This is most common with modems, and the cause is normally that the SID has not been
configured in the CM database. Use MOC to set the SID correctly.

Troubleshooting Page 3(6)


TMSL 197-46600-01 Issue 1: Sep 99

Repair Actions

The following is a list of repair action available for the TimeScan/NMS Platform. The
above section (Frequently Asked Questions...) has referred to these actions.

Reinstallation

Reinstallation is not a trivial task. A good knowledge of your operating system and the
TimeScan/NMS system are required. If you are uncertain you should not continue!
An installation guide is distributed with each system. This should be consulted before the
installation. Before this installation takes place the old system should be removed, if
possible using the following actions:
• Using the Add/Remove program application from the control panel to
remove the TimeScan/NMS system.
• Use the Remove Access Run Time item to remove all ODBC sources.
• Run the following command “C:\net-monitor\bin\supervisorservice -
remove”
• Delete the “C:\net-monitor” directory
Some of these actions may fail depending on how much of the system remains on your
hard disk. Once completed, installation may continue as specified in the installation guide.
After a successful installation follow the “Roll-back to previous database” section, on
page 5.

Restarting machine

Some applications with unsaved data will require you to save or discard the data before
they will let you restart the system.
If, after a period of 5 minutes after requesting shutdown, you still have a blank screen, the
hardware Reset button on the computer may be used.

Restart “Supervisor Service”

After restarting your computer, the NMS Services facility will be automatically restarted.
You can check that it is running by looking at your Task Manager (Windows) or Process
List (Unix).

Page 4(6) Troubleshooting


Issue 1: Sep 99 TMSL 197-46600-01

Roll-back to previous database

During routine maintenance operations the database files will be backed-up. See the
Operational Management chapter for more advice on this. If the database is damaged too
badly for repair, these files may be used to recover the database
For more information on Restoring your database files, see both the Operational
Management chapter, and your own proprietary database help.

Repair/Compact database

An tool is provided in the TimeScan/NMS Administrator program group to repair and


compact the database file. All programs must be shutdown, including stopping the NMS
Services application, then the “Compact Database” programs should be run. A pop-up
verifying that the Database was repaired successfully will be displayed on completion.

Troubleshooting Page 5(6)


TMSL 197-46600-01 Issue 1: Sep 99

(This page intentionally left blank)

Page 6(6) Troubleshooting