GENERAL

Case name:
Tag number: 10-FT -3021
P&ID Number: OL1-2G43-3013
Service: P-3030A/B REFLUX TO T-3030 Location: Line
Fluid state: Liquid Line number: 10-2"-BD-30423-B11A-H
Fluid phase: Single phase Line size: 2 in
Fluid name: CRUDE BUTADIENE Line schedule: STD
9 10
PROPERTIES
@Minimum @Normal @Maximum Units
Mass flow: 2739 5477 6901 kg/h
Upstream pressure: 9.97 kgf/cm²-g
Temperature: 43 °C
Viscosity: 0.23 cP
Velocity: m/s
Density: 598 kg/m³
Specific gravity:
Compressibility:
Vapor pressure: 5.1 kgf/cm²-a
Critical pressure: 43.7 kgf/cm²-a
11 12
ADDITIONAL PROPERTIES
Design pressure min: -1 kgf/cm²-g Corrosive: No
Design pressure max: 25 kgf/cm²-g Erosive: No
Design temperature min: -10 °C Toxic: Yes
Design temperature max: 160 °C Colored:
Entrained gas: % Transparent:
Required range: From: To: m³/h@flow Build-up tendency:
Limits on press.drop across flowmeter: 0.2 kgf/cm² Angle of repose: °
1 2
BASE CONDITIONS
Pressure: 1 bar-a Density: kg/m³
Temperature: 15.6 °C Specific gravity:
Compressibility:
7 8
ALARM
Alarm Trip
Low-Low-Low: Engineering units: m³/h@flow
Low-Low:
Low:
High:
High-High:
High-High-High:
3 4
API 2540 STANDARD
Density at reference temperature:
Specific gravity at reference temperature:
°API settings for: min / norm / max:
Reference temperature:
5 6
CUSTOM FIELDS
INST_PED_Phase INST_PED_Category INST_PED_Group

NOTE
1. BUTADIENE SERVICE.
2. FULL VACUUM @ 30°C
3. STEAM OUT CONDITIONS: 3 kg/cm2g @ 150 °C.
4. VORTEX FLOW METER TYPE SUGGESTED.

PROCESS DATASHEET
Plant: 10
2 SHT SLT SLT 14/07/2021 FINAL ISSUE (REVISE AS SHOWN) Area: Olefins Plant
1 TJH SLT RKM 21/02/2020 FINAL ISSUE (REVISE AS 30 SHOWN) Unit:
- BUTADIENE EXTRACTION UNIT (BDU)
0 OB FDO MM 05/11/2019 FINAL ISSUE Tag Number: 10-FT -3021 Sheet 1 of 1
No. By Chk App Date Description Dwg. Name: 10-FT -3021-PD Rev.: 2
14/07/2021 11:04:12