IN SPECTION CERTIFICATE S KPF$ FAcroRy : so, cHUNGJUsANDAN s-Ro, cHUNGJU-sr

CHUNGCHEONGBUK-DO, KOREA 380-250

Certificate No. J420t41,206033 Customer TANCO


TEL : (043)849 - 1L14
FAX : (043)849 - 1234

P/O No. 1.4P0431TC015- R00 Description STR H/H B I A325M TY1 HDG
L/C No.
Date Issued
TANCO
2074.r2.06
Grade A325M IY1
M24x3.OPx100
gf, FIELD OF TESTING : MECHANCICAL TESTING
LAB. ID. : 111983
Size lacctEofrEDl
CERT. NO. :0882.01
Date Shipped 20L4.Lt.27 Marking A325M,85,KPF LOGO
Date Tested
Date Manufactured
Specifications
2014.1L.1.8
2014.11.08
ASTM A325M - 09
Surface Condtion
Lot No.
Q'ty Shipped
HDG
2005888600
1,020 PCS
ffi
l-l'
SIANDARD OF CERTIFIED : ISO/IS 15949, ISO 9001-, ISO 14001
CERTIFICAT NO. : TS-01899, AC-01899, EAC-01899

STANDARD OF CERIIFIED : EN 14399-1.2.4.5.6.10

1. Chemical 2. Macroetch Meet


MI CERTIFICAT NO. : 1020 - CPD - 070038467
PAGE 1/1

Heat No.
c )l Mn P ) LT Mo Ni B Cu Ti AI
Division Surface Condition Random Condition Center Segregation Spec. of Test Method
x100 x100 x100 x1000 x1000 x100 x100 x100 x1000( x100 x100 x100 x1.000
Min. 30 10 60 Spec
Spec.
Max. 30 40 30 Results
HG66428 33 20 80 15 19 24 I 4 29 Tested By
3. Mechanical

HRC 31

( 10 ")
34L

This is to certify that the above results are true and correct in every details

./*.- ( t
Terry Kim
Chief of Quality Management Dept.

KPF
PAGE 2/2
Certificate No : J420141206033
4. Others
Decaburizatin Test 8y
Torque Tension Test Prevailing Torque Test
Microscope
Plate Salt Spray Remak
Division Partial Gross Tightening 1st Install Clamp 1st Rem.High't lst Rem.Low't 5th Rem.High't 5th Rem.Low't
Thickness Test Decarb.(B Decarb. Clamp Load prevailing Torque prevailing Torque prevailing Torque prevailing Torque
prevailing Torque Load
tvletal

Min
Unit
Max
Min
Spec
Max
I

Results o

10

Ave.
Iested By
Soec.of Test Method

Temperature
5. Heat Treatment
l,ilin. Temp

Max. Temp.
Quenching
Working Temp 870 'C

Holding Time 30 min.

Min.Temp. 427 "C

Working Temp. qnq


Tempering

Holding Time 90 min.

This is to certify that the above results are true and correct in every details

KPF
/NSPECT I O N CERT I F I CATE

'Tllt}'{
|

6
nff $ :ffir$r,',:g*:r:i'ffi*'^i,r-!r;
TEL : (6431649 - 11,0 :
.HUNGJU-',

(043)849 -
gh
FAX 1234

FIELD OF TESTING : MECHANCICAL TESTING


LAB. lD. :111983
tE-ii[?d CEFT. N0. : 882-01

ffil-F
STANDARD OF
0ERTtFtCAT
CERTIFIED
N0.

STANDARD OF CERTIFIED
:
:
ISO/TS 16949, ISO 9001, ISO 14001
TS-01899, AC-O1899, EAC-O1899

: EN 14399_1,2,4,5,6,10
ffil CERTIF|CAT N0. : 1020 - CPD - 070038467

Customer TANCO Surface Condition HDG

Lot No. 2005888600 Lot Size 1,020 EA

Description STR H/H B IA325M TY1 HDG Date issued Dec. 06. 2014

Size M24x3.0Px100 Specification ASTM F2329

1. Plate Thickness
Results
Contents Spec. Method Judgemen Remarks
x1 x2 x3 x4 x5 X

ASTM
Appearance Visual OK OK OK OK OK OK OK
F2329

Individual
MIN ASTM
Coating Zn 68.2wn 71.3un 68.Sllm 73.4wn 74.2un OK
43.Opn E376
Thickness

Average
MIN ASTM
Coating Zn 71.1 sn OK
53.7 pn E376
Thickness

2. Adherence Test : Passed

This is to certify that the above results are true and correct in every details

fr) u" rt*- V*"1


Terry Kim
Chief of Quality Management Dept.