Parameter List Parameter No. Index 0 Index 1 Factory Setting

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 10

pa

Factory
Parameter no. Index 0 Index 1
setting
p0003 3
P0010 1

P0015 41

P0100 "0"
P0210 400v

P0300 "0"
P0304 "0"
P0305 "0"
P0307 "0"
P0308 "0"
P0309 "0"
P0310 "0"
P0311 "0"

P0335 "0"
P0500 "3"

P0640 0.00 [Arms]

P0730 r52.3
P0731 r52.2
P0732 r52.0
p0748

[0] 4
[1] 4
P0756
[2] 0
[3] 0
P0757 0
[0] 10.000
[1] 10.000
P0759
[2] 20.000
[3] 100.000
P0758 0%
P0760 100%
[0] 21[0]
P0771 21(speed) 27(current)
[1] 27[0]
P0776 0
P0777 0.00 [%] 0 0
P0778 0.000 [V] 4 4
P0779 100.00 [%] 100 100
P0780 20.000 [V] 20 20

P0810 '0'
P0840 [0] 29659.0 r722.0… r722.0…
P1000 2 1 2

P1035 0 r722.3 0
P1036 0 r722.4 0
p1037 0.000 [rpm]
p1038 0.000 [rpm]
p1040 0.000 [rpm]
p1047 10.000 [s]
p1048 10.000 [s]
p1051 p1083
p1052 p1086

P1080 0.000 [rpm]


p1081 100%
P1082 1500.000 [rpm]
p1083 210000.000 [rpm]
p1086 -210000.000 [rpm]

P1110 '1'

p1111 '0'

P1113 '0'

P1120 10.000 [s]


P1121 10.000 [s]

P1300 20

P1900 2

p2000 1500.00 [rpm]


p2001 1000 [Vrms]
p2002 100.00 [Arms]
P2103 [0] 722.25 722.2 722.2
parameter list

No index
3: Expert
0

41

0: IEC-Motor (50 Hz, SI units)


400v

1: Asynchronous rotational motor


415
164amp
90kw
pf
E
50Hz
1480rpm

0: Self-cooled: Shaft mounted

186

r52.0
r52.3
r52.1

p748.0 - DO 0 (NO: T. 19 / NC: T. 18)


p748.1 - DO 1 (NO: T. 21)
p748.2 - DO 2 (NO: T. 24 / NC: T. 23)

3: Unipolar current input monitored (+4 mA to +20 mA)

'4'

'20'

'0'
100'
2: Current output (+4 mA ... +20 mA)

r722.1
r722.0

[1400 ] rpm
[ 0 ] rpm
[ 0 ] rpm
10s
10s

[ 0 ] rpm
100%
[ 1400] rpm
14000 (+ve) rpm
0 (-ve) rpm

10.000 [s]
10.000 [s]

0: V/f with linear characteristic

0: Inhibited

[ 14000 ]rpm
400v
186
Description
Access level
Drive commissioning parameter filter
Macro drive unit
Runs the corresponding
macro files.
Europe / North America / Europe / Nth Amer.
Drive unit line supply voltage

SELECT MOTOR TYPE


Rated motor voltage
Rated motor current
Rated motor power
Rated motor power factor / Mot cos_phi_rated
Rated motor efficiency / Rated efficiency
Rated motor frequency
Rated motor speed

Motor cooling
Technology application

Motor overload factor [%]Current limit

BI: CU Signal source for terminal DO 0


BI: CU Signal source for terminal DO 1
BI: CU Signal source for terminal DO 2
CU invert digital outputs
(1)Inverted, (0)Not Inverted
(1)Inverted, (0)Not Inverted
(1)Inverted, (0)Not Inverted

Analog inputs type

Value x1 of analog input scaling

Value x2 of analog input scaling

Value y1 of analog input scaling [%]


Value y2 of analog input scaling [%]
Sets the signal source for the analog outputs.

CU analog outputs type / CU AO type


Min. % value for analog output
Analog output Min. mA
Max. % value for analog input output
Analog output Max. mA

L/R selection bit


Drive ON / OFF
Selection of frequency setpoint

Motorized potentiometer setpoint raise


Motorized potentiometer lower setpoint
Motorized potentiometer maximum speed
Motorized potentiometer minimum speed
Motorized potentiometer starting value
Motorized potentiometer ramp-up time
Motorized potentiometer ramp-down time
CI: Speed limit RFG(Ramp-function generator) positive direction of rotation
CI: Speed limit RFG(Ramp-function generator) negative direction of rotation

Minimum speed
Maximum speed scaling
Maximum speed
CO: Speed limit in positive direction of rotation
CO: Speed limit in negative direction of rotation

Sets the signal source to


disable the negative direction
Sets the signal source to
disable the positive direction
Setpoint inversion
Sets the signal source
to invert the setpoint.
Ramp-up time
Ramp-down time

Control mode
Motor data identification
and rotating measurement

Reference speed reference frequency


Reference voltage
Reference current
BI: 1. Acknowledge faults
1: Pumps and fans
3: Pumps and fans, efficiency optimization