Professional Documents
Culture Documents
Mfr. Technical Offer
Mfr. Technical Offer
TECHNICAL OFFER
, . vallourec
KOC Date: 26.04.2020
1. PROPOSEDITEMS
··--
--
OD Weight PS
Tender
Item#
Type of
product IProcess (in) (ppf)
Grade Connection Drift Length L
Full prod uct details and performances are provided in the attached CDS for your review.
4. THREADED CONNECTIONS
LATEST THREADED AND COUPLED PREMIUM (SEE PRODUCT TECHNICAL
SUMMARY ATIACHMENT FOR FULL PRODUCT DATA).
VAM® KSX SC75
SC STANDS FOR SPEC IA L CLEARANCE IN ORDER TO MEET KOC
REQU IREMENTS FOR M AX 0 0 .
Latest Lice nsee Network list and products suppo rted ava ilable on :
http://www.vamservices.com/network/defau lt.aspx
Q~tar
.....,.
t I
Leslie THORES
Telepho ne office: 04-815011 9
Email: leslie.thores@vamfieldservice.com
7. ATTACHMENTS
A rlan AKHMETZHAN
Technica l Sales Manager
OCTG Division I Middle East
~ Pipe OD I
~
Connecti on :
CONNECTION DATA SHEET (Imperial Units)
_ _
r;;;i Pi pe 00 I
~
Connection 10
Make-Up Loss
[ Connection 00 [
In sour environments, the presence of H2 S can trigger Sulphide Stress Cracking (SSC) at stresses below the elastic
strength of the material until its rupture. It is important to notice that even at low levels of H2 S high strength's material
are susceptible to SSC phenomenon. When C110 was introduced as sour service grade into API 5CT in 2011 ,
Vallourec already produced 110ksi proprietary grades for sour service application, compliant with the standard NACE
MR0175 I ISO 15156 ar d guaranteeing additional SSC resistance.
Quality of Vallourec is assured by fully integrated process from raw material to threaded product, offering a complete
range of sour service products up to 125ksi, based on optimized combinations of material design , steelmaking , rolling
ind heat treatment, controlled to the most stringent quality program, with fina l SSC resistance proven through NACE
-M0177 testing and supported by an extensive history of more than 10 000 tests .
Vallourec 11 Oksi series combine a large variation of products to fit better with customer needs:
• VM 110 SS : QA/QC according to NACE method A
• VM 110 SS-D : QA/QC according to NACE method D
• Both SS and SS-D variants are also offered combined with High Collapse and Riser properties
• Dedicated Product Specification can be also designed according to specific customer application
• API has explicitly noted some concerns about the usage of API C110 on both SSC regions 2 and 3, as it is
not suitable for all Sour Service application. Sour Service 11 Oksi VALLOUREC proprietary grades have been
qualified for all SSC regions according to ANSI-NACE MR0175/ISO 151 56-2 standard for both tests method
A and Das per NACE TM0177.
• Wide experi ence on Fit For Purpose testing leadi ng to large database regarding:
- Specific test solution adapted to special well application
- SSC resistance proven at higher ppH 2S up to 7 bar (100 PSI)
- SSC resistance proven at lower temperature down to 2°C (35° F)
• Strong data base of DCB test performed on Casing pipes up to 16" in NACE TM01 77 solution A condition
proven better performances than API minimum requirements.
• Qualification report and more detailed information on test performances are available on request.
VALLOUREC - OCTG DIVISION - SOUR SERVICE GRADES 1lOKSI SERIES - EDITION JULY 2015 - REV 4 PAGE 1
Sour Service arades 110 KSI series
Technical features
Vallourec Sour Service grades are offered with state of the art VAM® connections
Field experience :
• Vallourec has more than 20 years of production experience in Sour Service products.
• Vallourec has delivered several 1OOkT of 11 Oksi sour service products around the word at GoM, North Sea,
Middle East, Pre-salt Project in Brazil, Africa, Canada, Australia, etc ... for various extreme applications such
as HPHT and Arctic condition.
• Vallourec 11 Oksi sour service grades have been mainly used in combination with VAM® connections.
Technical references:
With large capacity of testing and complete R&D structure, Vallourec has a long history on material development and
close intimacy with Oil and Gas comm unity:
• 3 research centers working on OCTG developments
• Permanent members on API , ISO and NACE Working Groups
• Following and participating to JIP's related to Sour Service development
• More than 20 publications on most of international conferences in the last 5 years , such as NACE and
Eurocorr
• Several patents granted around the world related to material's development
VALLOUREC - OCTG DIVISION - SOUR SERVICE GRADES 110KSI SERIES - EDITION JULY 2015 - REV 1 PAGE 2
PRODUCT SPECIFICATION Ref.: PS 11 003
Checke r: B. HAMILTON
VOGW<
Date : q /3 / 2 O IS
Visa :
Checker: J. SILVA
VBR
Date : 15 104 1 2015
Visa :
Checke r: A. ROSE
P. T. Citra Tubindo
Date: ~/3/2otS
l-~~
Visa:
Ch ecker: B. HIMES
TCA _,.
Date: /7 /oJ/d ,
Copy in : Visa : ~~
lil" controlled distribution
D non controlled distribution Application date*: 16 1 0412015
* this revision is applicable for new booking, it does not impact orders already booked
, . vallourec VM 110 SS
PS 11 003
rev. 2
Page 217
PRODUCT SPECIFICATION:
VM 110 SS
SOUR SERVICE GRADE
FOR CASING :516", COUPLING MATERIAL AND COUPLING STOCKS.
SUMMARY
1 SCOPE
2 PROCESS OF MANUFACTURE
3 MECHANICAL PROPERTIES
4 STRUCTURE
5 SULFIDE STRESS CRACKING RESISTANCE
6 INSPECTION
7 PIPE TESTI NG
8 PIPE ENDS
9 FINISHING - MARKING - PACKAGING OF THREADED PIPES
10 MATE RIAL TEST REPORT
11 QUALITY ASSURANCE ORGANIZATION
PS 11 003
VM 110 SS Page 3/7
rev. 2
I1 - SCOPE
This specification covers seamless casing with OD ~ 16"*, coupling material and coupling stocks with a wall thickness ~
50 mm* used for sour oil and gas wells; this sour service grade fulfills the requirements of NACE MR0175/ISO 15156
standards. The SSC resistance is tested accord ing to method A of latest edition of NACE TM0177 standard.
These casing, coupling material and coupling stocks are manufactured by Vallourec in accordance with latest edition of
API 5CT and ISO 11960** - group 2 specifications: C110, plus all requ irements specified hereafter.
* by agreement other dimensions can be offered
** except for marking.
I2 - PROCESS OF MANUFACTURE
2.1 - Steel
I Products are manufactu red from fully killed , vacuum degassed steel made in an electric or a basic oxygen fu rnace.
The chemical analysis on heat and products shall be in accordance with the following requirements:
Grade % c Si Mn p s Cr Mo Ni Cu
Min . 0.80 0.40
VM 110 SS
Max. 0.35 0.40 1.00 0.020 0.005 1.50 1.00 0.15 0.15
2.3 - Straightening
After heat treatment, pipes are submitted to either a cold rotary straightening followed by stress relief at 50°F to 100°F
(30°C to 55°C) below the fina l specified tempering temperature, or a hot rotary straightening with an exit temperature not
more than 300°F (165°C) below the final specified tempering temperature.
When necessary, light gag press straightening shall be permitted .
2.5 - Traceability
Each casing, coupling material and coupling stock is identified with an individual number through each step of production
after heat treatment so test data can be related to individual length.
Finished couplings are marked by low stress die stamping with the serial number of the mother coupling material or
coupling stock.
I3 - MECHANICAL PROPERTIES
The maximum number of prod ucts per testing lot is:
- 100 for casing ;
- 30 for coupling material and coupling stocks.
, . vallourec VM 110 SS
PS 11 003
rev. 2
Page 4/7
VM 110 SS 110 (758) 120 (828) 115 (793) 145 (1000) AP I formula
The hardness test results shall be in accordance with the following requirements:
Wall t hickness 0.500 or less 0.501 to 0.749 0.750 to 0.999 1.000 and above
in (mm) (12 .70 or less) (12 .71to19.04) (19.05 to 25.39) (25.40 and above)
3.0 4.0 5.0 6.0
I
Test temperature is -4°F (-20°C) and absorbed energy requirements are as per API 5CT and ISO 11960 specifications -
group 2: C110 . The shear area shall be reported and the minimum shall be 75%.
, . vallourec VM 110 SS
PS 11 003
rev. 2
Page 5/7
14- STRUCTURE
For each size, mass, chemical composition and austenitize-and-quench combination, the as-quenched hardness is
checked on four quadrants of one length of casing , coupling material or coupling stocks for each production run ; a
minimum 95% or 90% of martensite, depending on the wall thickness, is guaranteed by through -wall hardness
measurements. The mean hardness numbers shall equal or exceed :
I
VM 110 SS has been qualified as Sulfide Stress Cracking (SSC) resistant material anywhere within region 3 at any
temperature range, based on tests at ambient temperature, according to NACE MR0175/ISO 15156-2 standard table B.1
fnr test method A.
SSC resistance is tested according to method A (tensile test) of NACE TM0177 standard on proof rings.
The test con ditions are the following:
- ppH2S =1 bar = 100% H2S at atmospheric pressure
- NACE solution A
- T0 = 24°C +/- 3°C
The frequency is , per lot for casin g, coupling material and cou pling stocks, at the manufacturer's option:
a) 3 specimens, each one taken from an end of th ree different products, randomly selected from the front one-
third, middle one-third and back one-third of the lot.
If only one of the in itial specimens fails, a retest may be carried out on two furthe r specimens taken from an
area of the product adjacent to where the initial fa iled test specimen wa s taken . If either one of the retest
specimens fails , or if more than one of the initial specimens fails, the lot shall be either rejected or re-heat
treated .
b) 3 sets of 3 specimens , each triplicate coming from an end of three different products, rand om ly selected, from
the front one-third, middle one-third and back one-th ird of the lot. If more than one of the nine initial specimens
fai ls, the lot shall be rejected or re-heat treated .
c) According to an agreement with customer based on an approved process control plan , the frequency of
sampling and testing can be red uced to 1 specimen per lot, taken from one pipe rand omly selected. In case of
a fa ilure of t ri is specimen, a retest may be carried out on two further specimens taken from an area of the
product adjacent to where the in itial failed test specimen was taken . If one or more of the retest specimens
fails , the lot shall be either rejected or re-heat treated.
Specimens are taken at m id-wall and are tested at the following applied stress for f ull-size specimens (0 =0.250 in).
In case of sub-size specimens (0 = 0.150 in), a red uction factor of 0.9 will be applied on this above threshold stress (i.e.
76,5% SMYS).
I
A specimen with an invalid failure (as per addendum) will be reported and individually replaced by a new specimen. It
shall not be co nsidered n the pass rate criterion and the above-mentioned acceptance criteria will still be applicable.
If the wall thickness does not allow to machine NACE A specimens (sub-size) , NACE C test will be done using same
threshold stress as above (i.e. 85% SMYS) applied on OD surface (closing deflection) .
•vallourec VM 110 SS
PS 11 003
rev. 2
Page 6/7
Is -INSPECTION
6.1 - Dimensio nal inspection
I Outside diameter, wall thickness, mass and length values and measurement requirements are in accordance with API
5CT and ISO 11960 specifications.
Other dimensions can be supplied by agreement.
6.2.2 - Coupling
Threaded coupling are inspected by wet MPI , performed after final machining, on inside and outside surfaces, to detect
longitudinal and tran sve•se imperfections.
Ia - PIPE ENDS
Pipes are delivered in tr readed - coupled or integral con ditions, or as plain-end pipes.
I Pipes can be threaded with VAM® premium connections or with API connections.
, . vallourec VM110SS
PS 11 003
rev. 2
Page 7/7
For pipes and coupling stocks delivered in plain-end condition , following points are treated as requested in the Purchase
Order.
For threaded products, t..nless otherwise specified in the Purchase Order the following applies:
9.2 - Marking
Marking is applied in accordance with API 5CT specification , except die-stamping which is replaced by a low stress
stamping.
I
The grade marking to be placed in the manufacturing sequence and the color codes to be applied on pipe and coupling,
for this grade, are:
Special clearance coupling are painted as the standard coupling and with a black band around the center.
I
All exposed threads are protected with an anti-corrosion storage compound, and by installation of closed-end vented
thread protectors qualified according to API 5CT and ISO 11960 specifications - annex I. Non liftable thread protectors
are used for OD sizes 5 5" and fo r flush and semi-flush connections.
9.4 - Packing
OD sizes :>: 7" are packed in bundles.
OD sizes > 7" are handled in bu lk and shipped in horizontal layers.
Products covered by this specification are provided by Vallourec plants which are API licensed for the AP I 5CT
specification .
Moreover, the Vallou rec plants practice the quality programs described in their "Quality Manual", in accordance with the
API specification Q1 and ISO 9001 international standard.
, . vallourec VM 110 SS
PS 11 003
rev. 2
Addendum
An SSC test shall be deemed invalid and a replacement test performed , when an assignable cause is identified.
Assignable causes include but are not limited to:
• invalidation criteria as defined in TM0177 linked to testing errors:
o variation of the temperature during the test which leads to a temperature of the test solution out of the
authorized range 24 ± 3°C, as defined in the NACE TM0177
• machining defects on the test specimen reveled after test on the gauge length. Defects which could have been
masked by the polishing step of the specimen
• leak during the test that leads to:
o a deviation of the test-solution-volume to test-specimen-surface-area ratio as defined in the NACE
TM0 177 (30 ± 10 ml/cm 2 )
o a non-immersion in the test solution of the full gauge length of the specimen
• fai lure occurrence with a fracture surface (initiation or fina l rupture) outside the gauge length : "end failure" or
"fi llet failure"
OOCUMEKT RErERCNCl VRCC 16-080
RECOMMENDED RUNNING THREAD COMPOUNDS RCVIStoN 4.
I
VAM " CONNECTION PIPE MA~RIAL RECOMMENDED THREAD COMPOUND REFERENCES '
(PRODUCT LINE) CATEG'fY
BLACK RED YEllOW
,......~~~--r~~~~,.-~~~.....;
1 I' Clonf/kotlon ,,., OSPAR ro nkin{I ~
API Mod Jl SG JLSG ECF IOl.JOlONM 90L40lONM
APIMod JlSG
------+------+-
JL SG ECF 90ll010NM 80L4010NM
l NOU •bol.t CONW<doe ,.mwm1MH n llhidofl
.APIMod JlSG
The tl11ead compound! l111"'1n th~ dlx'ument haw been v•tld•trd ~'
API Mod Jl SG ISO 13679 / API RP 5C5 tnbn&<G!Wlillom. le. to 1 mlnlm\lm of l M1•e-
•nd-8reak • 1 final M•le-Upfo1 CHtn1\.11ts, and 9 M 1\:t'-i1nd· Bre.lc • 1
Fln1I Mah· Up fOf Tubin& \ttts (peepuom m.y apply dt'~dm& on sues
;and 11•de1, typk•ltt fo1 hl&f'l-Chtorne m~et~ that UJ~llv haw a hlcl'I«
s~ftlvttv t o 1•llln&} Pedonnanc:• may Mo v1ry ~pendin1 on conc:fJtiolu
of use lweatht1 cond1Uo"'· temptutur•. tnlll ltide ...}
IOl4010 NM
n•CH nry, fv rthtt chtllb ubd lo VAM· S.fVku Of"°"'
\IJUll T1ch nk1I
S1lu corrupo~•nL
90l4010 NM
/oskforap!JonsJ
(cu k jorop 1io11s)
' Note 11MM1t 'Yelow' thle1d , _,,..,.,.,
Sf'vflal t hread comPoU\lh do1UWt.dM 'Ytllo"N' ~r OSPAR 1•nkin1 un bt
und o n V.6.M• connKtlons, tKlt the connt<OoM' HMh Mtvto 11H1na nwv
bt ln«t HC!d when 1uch compounch arr combined wit h suer ind CRA
m.neri1Ji (then redudna. k'I Mrne <Mes, the v•ll1b1ed number ol M1._e-
•t1d-8realc n d~crlbed In Note' •bov•)
With rl'1ard to se.labU1tv, tt'O'lpB"ltwe hmit.iloM mav apply v.iltn t f\tlna
some desl1rn w 11h YtOow thread compounds to tht' hl&h ~t ltNds of ISO/
JLSG ECF IOL .tOlON ~
AJ>lprotocob
' API Modft!td' th1ead compounck (CH' thread compound c~nl1ied H 'Red1
remain the prefe!'red opdon. perl'~ance--11111te
JLSGECF
' Nate1bout 'Aflt~&~ dwH4~t
AllVAM· cot1n«tloM C•n be 1Aed Wl(h ' APt MOdl'ied' thfHd compol.lftds
conformin& to A.Pl RP SAl (b1'.f11l • ff!W rt'fetM<t'S that 11e not app1owd •
~~ /'t~rNft~r ). 'lo.Pt Moddtt'd' \hould be undt'ntood •s thread compouncb
l or which laboratory P«f0tmMK«S comply '*l'lh API RP SA3, and whon
chemkal composition G In ICCOfd«Ke With &mll.11. of API MP SAl
Ho~r . thrt'•d compout1d$ ~CO"'PO'flion k ontv compll11nt with
~or API RP SIJ lft' "°' fKOtnmen~ un~ t h~ hlVt' bt't'r1
qwlifled on VAM• product.I (11'14! content o l Anne• A of API RP SAl coutd
lormt'lly be lound In API But SAl, nowobsolt.1.t')
JLS<i ECF
"Note •bowt eempentw ... .UUdoN
JlSG ECF TemperitUfe Umltat loM Wt' ptOl!Cded fOf lnformMlon puipo'e onf'.I.
'f'mM'I'
AJth o u1h t he 11r1ec: 1ovibcYtt' • t hreaddt'slsn 10 1henmt' lrttl
of ~rformantft flndudln1 tett templ!lll:ur•l atcrou t ht' whole ran1eot
shes, \ ome r rftlul combinations ot OO~hl/&r•df:/CAL ~/compound
rtfl!nnce m1v lud to coMkift' ttductktn to lht tt'mPt".tlult' applied
JLSGECF dwln11nt in1.
for any ' peclf1c 1pp!K.lt10tt • l - n hoa'ltw" 1empe111urH i> 1so·c / ]S(i"FI.
plHU contl(1 VAM" s.Mces CH ¥OUI IAWI Technlc-11 Sales COtr1$pondent
80l4010 NM
• OSPAR:O!.k>P.1rbCOl!Wftll-
HOCNF: Ho1rmon~Of'fd1areOemlulHotafia11Dn Jorm.11
VAM'"HTT OCNS: Off\l'lofe Chenlrul Ncd·otlOll kMrN
1-..;8-
0L.40
= 10;,;Niii
M" - , j BESTOUfE 4010 N M
~-°'-
'- t~-"-'_, ~r compounds rf'/f'nn<H may be uud on o cow·b)"'<OU' b~ P~~ contocl VA M•
'"-'•.c.p_
-JOS,AJl rw1ln1 •
-J HOC.NF • OC.NS r.1ln1 •
-tOS'AA rwt1r11 •
~ HOChf • OCHS rwlfn1 •
Notes :
As the connection's use conditions are not included in the table (temperature, storage conditions ... ), this table is given for information purpose only.
Do not hesitate to contact VAM® for additional requirements or to describe your specific needs. For storage compound not listed in the table, please
contact VAM®.
For details on service rating and corrosion performances, please refer to the manufacturers data .
As a general statement, VAM® recommends to inspect a random 10% of the stored threaded pipes every 6 months to check for degradation . If there is
sign of corrosion or damage, all threaded pipes should be cleaned, inspected and new storage compound shall be re-applied.
For more details on application and removal of storage compound , please refer to VAM® Book.
VAM® is also offering CLEANWELL® DRY, a dopefree and environmentally friendly solution.
Please contact VAM® or your sales contact for more information.
VA M®, Big Omega® and CLEANWELL® are registered trademarks of the Vallourec Group; All other trademarks and registered trademarks are the property of their respective
owners.
Premium quality network
- Annual audit of each licensee
- Licensor Technical Representative (LTR)
presence at licensee shop at customer's request
Extensive product & ge ographical
coverage
- Largest licensee network
- Proximity to your operations
Partnership with Oilfield Service companies
Technical support management
- VAM Schools at licensees' facilities
- Mr Help for all users
Visit us at:
. '
.,.,.
• • • SERVICES
, . vallourec
VAM® Accessories manufacturing
- Casing Accessories
- Field running accessories Homogeneity of performances
- Completion accessories into the well.
Threading VAM ! on components No compromise between quality
-Com p~tioneq~pment and short lead time.
- Improve interface with hanger
- Float equipment Vallourec expertise on VAW
and metallurgy.
Tailor-made solutions
- R&D support to assess technical challenges Tailor-made solutions.
- Tailor-made design
- Finite Element Analysis (FEA)
Loose couplings
- For isolated coupling needs Sole supplier for complete project
schedule.
List of typical parts:
Pup, saver sub, nipple, wire line re-entry guide, Worldwide sales and industrial
mule shoe, test cap/ test plug, circulating head, coverage.
flow coupling, flo-pup®, blast joint, cross-overs,
lifting equipments, pump-in sub.
, . vallourec
An international network
of over 160 qualified field service
engineers in 11 service centres Best running practices ensured
Expertise in all field aspects of OCTG through VAM• Field Procedures.
and the VAM family of connections Avoid rejects coming from bad field
- Rig preparation of tubulars practices (handling damages...).
- Running supervision
- Rig return inspection Make-up graph interpretation
- Assembly make-up and supervision experts: detect suspicious
- Audit and advices pertaini ng to VAM' best practices make-up and identify root cause.
- Fit for purpose supervision
Available on call-off basis for
"spot jobs" or full time basis at customer's
location for a 24/7 support Save rig time by prevent damaged
connections reaching drill floor.
Strong experience of
VAM' Field Service engineers Prevent damages during handling
- Extensive trai ning program (VAM · Academy) operations.
- Regular competency assessments Less rejects thanks to expert
using OPITO methodology inspection and light repairs.
- Support from the VAM · Research & Development teams
,,.,.
- Direct interface with the whole VAM · experts
_ , FIELD SERVICE
Focus on safe installation of
critical barriers against
well pressures.
..c~
,.::e:..
c:
..,
~
::>
~
Increase safety of operations ~
by reducing the quantity of pipes 0
....
handled. i
.,,~
---~~~~~~~~~~~~~--' =
, . vallourec
Material selection
- Extensive pipe and material data
- Expertise in corrosion and corrosion
resistant grades
- Selection of the most suitable grades based
on your well conditions and project targets
Conventional casing design
- Using industry standard well design software
- Deep knowledge of the tubular products
and manufacturing
- Expertise in VAW premium connections
development and testing
Advanced casing design
- Including thermal analysis
- For the most critical projects (HP/HT, deepwater, etc.)
- R&D support available
, . vallourec
¥...,
CANADA
CHINA
w
""' U.S.A.
MEXICO
..,.,.
INDONEStA ,,,
"'.:J' ..,,..
ljl
ANGOLA
AUSTRALIA
""'
8 Sales Offices
~ Manuf.lcturing Plants
. '
, . vallourec
WWW. Va ffi Se rviCeS.COffi ~~~ is.,e91>te-tdtr>dt Jr~ IVJ ourecMJnn•<111Jnn &Ga f
, . vallourec
Certificate of Authority to use the Official API Monogram
License Number: SCT-0066.5 ORIGINAL
In all cases where the Official API Monogram is applied, the API Monogram shall be used in conjunction with this
certificate number: SCT-0066.5
The American Petroleum Institute reserves the right to revoke this authorization to use the Official API Monogram
for any reason satisfactory to the Board of Directors of the American Petroleum Institute.
To verify the authenticity of this license, go to www.api.org/composltellst. Vice President of Global Industry Services
Certificate of Authority to use the Official API Monogram
License Number: SCT-0186.4 ORIGINAL
the right to use the Official API M onogram~ on manufactured products under the conditions in the official
publications of the American Petroleum Institute entitled API Spec Q1a and APl-5CT
and in accordance with the provisions of the License Agreement.
In all cases where t he Official API Monogram is appl ied, the API Monogram shall be used in conjunction with this
certif icate number: 5CT-0186.4
The American Petroleu m Institute reserves t he right to revoke this authorizat ion to use t he Official API Monogram
for any reason satisfactory to the Board of Directors of t he American Petroleum Institute.
The scope of this license includes the fo llowing: Manufacturer of Casing or Tubing Couplings, Manufacturer of Casing or
Tubing Pup Joints, Manufacturer of Coupling Stock or Accessory Material, Manufacturer of Seaniess Casing or T ubing (Plain End),
Manufacturer of Sea m ess Casing or Tubing (Threaded and Coupled) - C110, PSL 1, - C90, PSL 3, - H40, PSL 1, - J55, PSL 3, - K55,
PSL 3, - L80(1), PSL 3, - L80(13Cr), PSL 3, - L80(9Cr), PSL 1, - N80(1 ), PSL 1, - N80(0 ), PSL 3, - P11 0, PSL 3, - 01 25, PSL 3, -
R95, PSL 3, - T95, PSL 3; Processor of Casing, T ubing, Coupling Stock, or Accessory Material (Plain End), Processor of Casing or
T ubing (Threaded and Coupled) - C110, PSL 1, - C90, PSL 3, - J55, PSL 3, - K55, PSL 3, - L80(1), PSL 3, - L80(13Cr), PSL 3, -
L80(9Cr), PSL 1, - N80(1 ), PSL 1, - N80(0 ), PSL 3, - P1 10, PSL 3, - 0 125, PSL 3, - R95, PSL 3, - T 95, PSL 3; Pipe T hreader
To verify the authenticity of this license, go to www.apl.org/composltellst. Vice President of Global Industry Services
Certificate of Authority to use the Official API Monogram
License Number: SCT-1345 ORIGINAL
the right to use the Official API Monogram8 on manufactured products under the conditions in the official
publications of the American Petroleum Institute entitled API Spec Q18 and APl-5CT
and in accordance with the provisions of the License Agreement.
In all cases where the Official API Monogram is applied, the API Monogram shall be used in conjunction with this
certificate number: SCT-1345
The American Petroleum Institute reserves the right to revoke this authorization to use the Official API Monogra m
for any reason satisfactory to the Boa rd of Directors of the American Petroleum Institute.
T he scope of this license includes the following: Manufacturer of Casing or Tubing Couplings, Manufacturer of Casing or
Tubing Pup Joints, Manufacturer of Coupling Stock or Accessory Material, Manufacturer of Seaniess Casing or Tubing (Plain End),
Manufacturer of Seaniess Casing or Tubing (Threaded and Coupled) - C90, PSL 3, - H40, PSL 1, - J55, PSL 3, - K55, PSL 3, -
L80(1 ), PSL 3, - N80(1), PSL 1, - N80(Q), PSL 3, - P110, PSL 3, - Q125, PSL 3, - R95, PSL 3, - T95, PSL 3; Processor of Casing,
Tubing, Coupling Stock, or Accessory Material (Plain End), Processor of Casing or Tubing (Threaded and Coupled) - C90, PSL 3, -
J55, PSL 3, - K55, PSL 3, - L80(1), PSL 3, - N80(1), PSL 1, - N80(Q), PSL 3, - P110, PSL 3, - 0125, PSL 3, - R95, PSL 3, - T95, PSL
3; Pipe Threader
To verify the authenticity of this license, go to www.apl.org/composlteflst. Vice President of Global Industry Services
Certificate of Authority to use the Official API Monogram
License Number: SCT-0401 ORIGINAL
the right to use the Official API Monogram19 on manufactured products under the conditions in the official
publications of the American Petroleum Institute entitled API Spec Q19 and APl-5CT
and in accordance with the provisions of the License Agreement.
In all cases where the Official API Monogram is applied, the API Monogram shall be used in conjunction with this
certificate number: 5CT-0401
The American Petroleum Institute reserves t he right to revoke this authorization to use the Official API Monogram
for any reason satisfactory to the Board of Directors of the American Petroleum Institute.
The scope of this license includes the following: Manufacturer of Casing or Tubing Couplings, Manufacturer of
Casing or Tubing Pup Joints, Manufacturer of Coupling Stock or Accessory Material, Manufacturer of
Seamless Casing or Tubing (Plain End), Manufacturer of Seamless Casing or Tubing (Threaded and Coupled) -
C110, PSL 1, - C90, PSL 3, - J55, PSL 3, - K55, PSL 3, - L80(1), PSL 3, - L80( 13Cr), PSL 3, - N80(1), PSL 1, -
N80(Q), PS L 3, - P110, PSL 3, - Q125, PSL 3 - R95, PSL 3, - T95, PSL 3
To verify the authenticity of this license, go to www.apl.org/composltellst. Vice President of Global Industry Services
RFQ# 2072853 Appendi x - 2C
No m inal Nominal Nominal Drift Special Int erna l Collapse Body Yi1
Spec.
Description Vallourec P roposa l OD Weight ID Diameter Drift Yield Pressu r e Re s is ta n ce Streng I
Ref.
{I n.) ( PPF ) ( In. ) ( I n.) (In. ) ( PSI ) ( PSI ) (X iooo lb
CSG IC.H n 2 PPF SS· 110. PRF~llU\1 (T&Cl CO'I SPL
1 CSG l<•H... n 2 ppr \ ' \II IOSS \"A\I• l(SX SC7< 10.75 73.2 9.406 9.25 na (" ) 12030 10010 2340
fLfPLG SfA\111 SS & ACCESSORIES
CSG. 11•.1 • • 712 pp~ P·l 10, PRLMIL\1 <T&.C) co' SPL
2
CL CPLG SEAMLESS & ACCESSORIES
CSG 10..31• ·. 712 PPF P-110. \"AM• l(SX SC15 10.75 73.2 9 .406 9. 25 na ( ' ) 12030 10010 2340
Please note that the data listed 1n the above ta~ e 1s given for ~nformatJon only.
Should there be an d1screpan between lhe above data and the CDS Connection Data Sheet data sent with the tech nical offer, the CDS data prevails
Page 1of2
RFQ• 2072853 Appendix - 20
Please note that the data listed in the aboYe tatje ls gNen tor 1nlorm1hon onty
Should there be an d.scre betv.een the above data and the COS Connection Data Sl'\eel dala 1en1 \Mlh lhe 1ecnr11cal otf~r. lhe COS dala evauls
Page 1ol1
SCOPE OF INSPECTION
(TO BE CARRIED OUT IN MANUFACTURER'S FACILITY)
(CASING & TUBING)
A Third Party Inspection Agency, whose fee will be for KOC's Account, will be appointed shortly after placement of
Order. KOC reserves the right for its appointed Inspection Agency to inspect material/equipment during and on
co mpletion of manufactur e. The manufacturer shal l allow KOC or its appointed Inspection Agency free entry at all
times and to all areas whi le work on this Order is being performed. The manufacturer shall afford th e inspector,
without charge, all reasonable facilities to satisfy him that the material/equipment is being manufactured in
accordance with the specification. All inspections should be made at the place of manufacture prior to shipment.
This will be so conducted as not to interfere unnecessarily w ith the operation of the works.
The manufacturer shall include a statement in al l sub-contract Orders to allow KOC or its appointed Inspection
Agency entry to the sub-contractors works. Al l requests for such inspection will be made through the main
manufactu rer.
1. The following tests w ill be performed or witnessed by the appointed Inspection Agency.
1.1 Witness rol ling of pipes and measurem ent of all dimensions including wall thickness
1.2 Perform in ternal/external, optical/visual inspection.
1.3 Wit ness manufacturer's hydrostatic test as per API 5CT. These tests shall be carried out on plain end
pipes on which connectors are to be w elded and on threaded pipes having integral or th readed and
cm. pied connection.
1.4 Review manufacturer's test certificates for analytical chemistry results.
1.5 Witness manufacturer's mechanical tests.
1.6 Perform thread inspection visual & gauge prior to fitting of th read protectors. Ensure that the gauges
are calibrated and certified by independent authority/ laboratory. All threads shall be cut by licensees
only. Vallourec proposes a witness review only. TPI not to perform gauging.
1. 7 Witness fitting of threads protectors by the manufacturer.
1.8 Check marking as per API 5CT, which shall include the type of th read.
1.9 Ensure mill's anti-rust coating/painting is applied externally.
1.10 Witness the tu bular performance tests (collapse pressure and burst pressure) and connection joint
strength test if required by the order. Please note that the wit ness of tubular tests (collapse test &
burst test) and connection joint strength test is not applicable for offered items.
1.11 In case of welded tu bular, verify the ca libration and adequacy of production weld monitoring
syst em. Not applicable for offered items.
1.12 Witness/ Perform full length MPI and End Area Inspection. Full length MPI is not applicable. Ends of
Pipes are either checked by MPI or cropped off as per specification.
2. General Notes:
2.1 Each item of the Purchase Order will be subjected to 100% inspection and testing unless
otherwise stat ed in the Order docu ments.
The frequency of products' testing and verifications is as per applicable specification dependent
of API 5CT grade and PSL.
2.2 It is the supplier's/manufacturer's responsibility to liaise with the Inspection Agency to arrange
mutua lly convenient inspection times. Should the supplier/ manufacturer be unable to contract
the Inspection Agency then the supplier should inform KOC and include precise details of their
attempts to make contact including copies of tele-faxes.
2.3 The manufacturer must not ship material without obtaining a written Release Note of
Accepta nce from the appoin ted Inspection Agency.
2.4 The issuing of a Release Note of Accepta nce by the appointed Inspection Agency does not
relieve the manufacturer/supplier of their responsi bility to provide materials in compliance w ith
the Order specification.
2.5 KOC w il l neither accept nor pay for any material which does not pass inspection and/ or shipped
without obtaining a written Release Note of Acceptance from inspectors.
2.6 The cost of re-inspection of an item or sub-item due to non-compliance w ith Order
specifications will be debited to supplier's account. Also, if the TPI agency cannot perform their
duties either due to disruption in production or breakdown of equipment, the inspector's fees
for the sta ndby time shall be debited to supplier's account
2.7 In case cancellation of an Order due to non-compliance with Order specifications, the whole
inspection fee/ Invoice wil l be debited to the supplier's account.
2.8 Bidders must submit a clear statement that 3rd Party Inspection to the Scope stated in the
Enquiry/Tender document is acceptable to the manufacturer. Offers without this statement will
be disqualified.
2.9 The manufacturer shall provide the Inspection Agency with three sets of tests.
Certificates covering all inspection activities carried out by the manufacturer.