CB7 Systems LLC 200016 CBF Load System Specifications

200016
CBF
Water Cooled
AC Load System
Specifications

CB7 Systems LLC

Version 0.01 Page:1 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

© 2014 CB7 Systems LLC — All Rights Reserved.


The copyright laws of the United States and other countries protect this material. It may not
be reproduced, distributed, or altered in any fashion without the expressed written consent of
CB7 Systems LLC.

Disclaimer
The contents of this document, including all specifications, are subject to change without
notice.

Version 0.01 Page:2 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

Version 0.01 Page:3 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

200016 Technical Data


Size:

72 in x 40 in x 24 in

Weight:

850 lbs.

Voltage:

480 VAC 3Ph Delta 50/60Hz

Current:

303 A/Ph

Power:

252 KW

Maximum Flow Rate:

60 GPM

Maximum Fluid Pressure:

150 PSI

Maximum Outlet Temperature:

Adjustable to 95 degC

Load Connections:

Cam Lok

Fluid Connections:

2 inch type F

Coolant:

water or water/glycol

Version 0.01 Page:4 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

200016 Technical Data (cont)


Operation Modes:

Loadbank (fixed power load)


Delta T (fixed power)
Delta T (fixed flow rate)
Fixed T (fixed power)
Fixed T (fixed flow rate)

Measurement Capability:

Input Load Voltage


Load Current
Load Power
Inlet Temperature
Exhaust Temperature
Fluid Flow Rate
BTUs expended

Safety Features:

Over Temperature (sensor / thermal switch / relief valve)


Adjustable Limit On Exhaust Temperature
Over Pressure
Over Power
Over Voltage
Trapped Air
Phase Imbalance

Display:

7 inch Color Touch Screen

Version 0.01 Page:5 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

200016 Technical Data (cont)

Communication:

Ethernet
CAN bus
RS232
USB

Protocols:

HTTP (web)
TCP Sockets
Modbus TCP
SNMP v2c
Telnet
J1939 (CanBus)

External Control Power:

120VAC Single Ph (150 watt)8 channels

Extended Configuration:

Series connection higher power with extended Delta T


Parallel connection higher power with increased flow rate

Other:

Real Time Clock Calendar


1MB non volatile memory

Version 0.01 Page:6 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Windows Control

Version 0.01 Page:7 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Integrated Web Page

Version 0.01 Page:8 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Android Control

Version 0.01 Page:9 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Touch Screen Interface

Version 0.01 Page:10 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF ASCII Commands

SETP sets load bank fixed power level


DTF sets load bank delta t / fixed flow mode
DTP sets load bank delta t / fixed power mode
FTF sets load bank fixed t / fixed flow mode
FTP sets load bank fixed t / fixed power mode

VAB? returns measured AB phase voltage


VBC? returns measured BC phase voltage
VAC? returns measured AC phase voltage
IA? returns measured A phase current
IB? returns measured B phase current
IC? returns measured C phase current
V? returns composite measured phase voltage
I? returns composite measured phase current
P? returns load bank measured power
TIN? returns measured input temperature
TOUT? returns measured exhaust temperatures
FLOW? returns measured flow rate

ALARM? returns load bank alarm value


STATUS? returns load bank status value

BTU initializes BTU counter


BTU? returns BTUs expended

FAREN changes to fahrenheit units mode


CELSI changes to celsius units mode
CLRALRM clears the load bank latched alarms
CLRSTAT clears the load bank latched status

SETP? returns load bank programmed power


MODE? returns load bank programmed operation mode
DT? returns load bank programmed delta t
F? returns load bank programmed flow rate
MODEL? returns load bank model information

MAXP? returns load bank telemetry - maximum applied power


MAXV? returns load bank telemetry - maximum applied voltage
MAXI? returns load bank telemetry - maximum applied current
MINV? returns load bank telemetry - minimum applied voltage (under load)
MAXF? returns load bank telemetry – maximum flow rate
MINF? returns load bank telemetry – minimum flow rate

Version 0.01 Page:11 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF ASCII Commands (cont)

IP? returns Ethernet IP address


IP sets Ethernet IP address
NM? returns Ethernet Net Mask
NM sets Ethernet Net Mask
GWY? returns Ethernet Gateway address
GWY sets Ethernet Gateway address
PORT? returns Ethernet TCP port value
PORT sets Ethernet TCP port value
MAC? returns Ethernet MAC address

SNMPNME? returns SNMP name information


SNMPNME sets SNMP name information
SNMPCON? returns SNMP contact information
SNMPCON sets SNMP contact information
SNMPLOC? returns SNMP location information
SNMPLOC sets SNMP location information
TRAPADR? returns SNMP trap addresses
TRAPADR sets SNMP trap addresses
TRAPEN? returns SNMP enabled trap addresses
TRAPEN sets SNMP enabled trap addresses
TRAPCOM? returns SNMP trap community information
TRAPCOM sets SNMP trap community information
TRAPTEST sends a test trap to all enabled trap addresses

COMMCFG? returns active communication channels


COMMCFG sets active communication channels
TEMP? returns load bank internal processor temperature

Version 0.01 Page:12 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Modbus Register Map

Discrete Register 0x08 Voltage Phase Imbalance Alarm


Discrete Register 0x09 Current Phase Imbalance Alarm
Discrete Register 0x0A Trapped Air Alarm
Discrete Register 0x0B Over Temp Alarm

Input Register 0x01 AB Voltage


Input Register 0x02 BC Voltage
Input Register 0x03 AC Voltage
Input Register 0x04 A Current
Input Register 0x05 B Current
Input Register 0x06 C Current
Input Register 0x07 Measured Power
Input Register 0x08 Measured Voltage
Input Register 0x09 Measured Current
Input Register 0x1E Card Temperature
Input Register 0x22 AB BC Voltage Imbalance
Input Register 0x23 AB AC Voltage Imbalance
Input Register 0x24 BC AC Voltage Imbalance
Input Register 0x25 AB Current Imbalance
Input Register 0x26 AC Current Imbalance
Input Register 0x27 BC Current Imbalance
Input Register 0x28 Max Measured Power
Input Register 0x29 Max Measured Voltage
Input Register 0x2A Max Measured Current
Input Register 0x2B Min Measured Voltage Under Load
Input Register 0x2A 1000*VAB Gain Cal
Input Register 0x2B 1000*VBC Gain Cal
Input Register 0x2C 1000*VAC Gain Cal
Input Register 0x2D 1000*IA Gain Cal
Input Register 0x2E 1000*IB Gain Cal
Input Register 0x2F 1000*IC Gain Cal
Input Register 0x31 System Voltage
Input Register 0x32 System Current
Input Register 0x33 System Power
Input Register 0x34 SystemType
Input Register 0x35 INTEGER FIRMWARE VERSION
Input Register 0x36 INTEGER PART NUMBER
Input Register 0x37 IP 0
Input Register 0x38 IP 1
Input Register 0x39 IP 2
Input Register 0x3A IP 3
Input Register 0x3B NM 0
Input Register 0x3C NM 1
Input Register 0x3D NM 2
Input Register 0x3E NM 3
Input Register 0x40 GWY 0
Input Register 0x41 GWY 1
Input Register 0x42 GWY 2
Input Register 0x43 GWY 3
Input Register 0x44 MAC 0

Version 0.01 Page:13 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Modbus Register Map (cont)

Input Register 0x45 MAC 1


Input Register 0x46 MAC 2
Input Register 0x47 MAC 3
Input Register 0x48 MAC 4
Input Register 0x49 MAC 5
Input Register 0x4A DNS1 0
Input Register 0x4B DNS1 1
Input Register 0x4C DNS1 2
Input Register 0x4D DNS1 3
Input Register 0x4E DNS2 0
Input Register 0x4F DNS2 1
Input Register 0x50 DNS2 2
Input Register 0x51 DNS2 3
Input Register 0x52 DHCP 0
Input Register 0x53 DHCP 1
Input Register 0x54 DHCP 2
Input Register 0x55 DHCP 3
Input Register 0x56 SMTP 0
Input Register 0x57 SMTP 1
Input Register 0x58 SMTP 2
Input Register 0x59 SMTP 3
Input Register 0x5A SNMP Trap Address 00
Input Register 0x5B SNMP Trap Address 01
Input Register 0x5C SNMP Trap Address 02
Input Register 0x5D SNMP Trap Address 03
Input Register 0x5E SNMP Trap Address 10
Input Register 0x5F SNMP Trap Address 11
Input Register 0x60 SNMP Trap Address 12
Input Register 0x61 SNMP Trap Address 13
Input Register 0x62 SNMP Trap Address 20
Input Register 0x63 SNMP Trap Address 21
Input Register 0x64 SNMP Trap Address 22
Input Register 0x65 SNMP Trap Address 23
Input Register 0x66 SNMP Trap Address 30
Input Register 0x67 SNMP Trap Address 31
Input Register 0x68 SNMP Trap Address 32
Input Register 0x69 SNMP Trap Address 33
Input Register 0x6A TCP Port
Input Register 0x6B Communication Cfg
Input Register 0x6C CBF current mode
Input Register 0x6D CBF current status
Input Register 0x6E CBF current alarm
Input Register 0x6F CBF msrd power in KW
Input Register 0x70 CBF msrd inlet temp
Input Register 0x71 CBF msrd exhaust temp
Input Register 0x72 CBF msrd flow rate
Input Register 0x73 CBF msrd delta t
Input Register 0x74 CBF fahrenheit / celsius
Input Register 0x75 CBF set power
Input Register 0x76 CBF set delta t
Input Register 0x77 CBF set t exhaust

Version 0.01 Page:14 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Modbus Register Map (cont)


Input Register 0x78 CBF set flow rate
Input Register 0x79 CBF pcr drive voltage
Input Register 0x7A CBF servo drive voltage
Input Register 0x7B CBF flow switch
Input Register 0x7C CBF max measured flow rate
Input Register 0x7D CBF min measured flow rate
Input Register 0x7E CBF max measured temp

Holding Register 0x01 Reset System


Holding Register 0x02 Restart System
Holding Register 0x1E Card Temperature
Holding Register 0x22 AB BC Voltage Imbalance
Holding Register 0x23 AB AC_Voltage Imbalance
Holding Register 0x24 BC AC_Voltage Imbalance
Holding Register 0x25 AB Current Imbalance
Holding Register 0x26 AC Current Imbalance
Holding Register 0x27 BC Current Imbalance
Holding Register 0x28 Max Measured Power
Holding Register 0x29 Max Measured Voltage
Holding Register 0x2A Max Measured Current
Holding Register 0x2B Min Measured Voltage Under Load
Holding Register 0x2A 1000*VAB Gain Cal
Holding Register 0x2B 1000*VBC Gain Cal
Holding Register 0x2C 1000*VAC Gain Cal
Holding Register 0x2D 1000*IA Gain Cal
Holding Register 0x2E 1000*IB Gain Cal
Holding Register 0x2F 1000*IC Gain Cal
Holding Register 0x31 System Voltage
Holding Register 0x32 System Current
Holding Register 0x33 System Power
Holding Register 0x34 System Type
Holding Register 0x35 INTEGER FIRMWARE VERSION
Holding Register 0x36 INTEGER PART NUMBER
Holding Register 0x37 IP0
Holding Register 0x38 IP1
Holding Register 0x39 IP2
Holding Register 0x3A IP3
Holding Register 0x3B NM0
Holding Register 0x3C NM1
Holding Register 0x3D NM2
Holding Register 0x3F NM3
Holding Register 0x40 GWY0
Holding Register 0x41 GWY1
Holding Register 0x42 GWY2
Holding Register 0x43 GWY3
Holding Register 0x44 MAC0
Holding Register 0x45 MAC1
Holding Register 0x46 MAC2
Holding Register 0x47 MAC3
Holding Register 0x48 MAC4
Holding Register 0x49 MAC5

Version 0.01 Page:15 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Modbus Register Map (cont)


Holding Register 0x4A DNS1 0
Holding Register 0x4B DNS1 1
Holding Register 0x4C DNS1 2
Holding Register 0x4D DNS1 3
Holding Register 0x4E DNS2 0
Holding Register 0x4F DNS2 1
Holding Register 0x50 DNS2 2
Holding Register 0x51 DNS2 3
Holding Register 0x52 DHCP0
Holding Register 0x53 DHCP1
Holding Register 0x54 DHCP2
Holding Register 0x55 DHCP3
Holding Register 0x56 SMTP0
Holding Register 0x57 SMTP1
Holding Register 0x58 SMTP2
Holding Register 0x59 SMTP3
Holding Register 0x5A SNMP Trap Address0 0
Holding Register 0x5B SNMP Trap Address0 1
Holding Register 0x5C SNMP Trap Address0 2
Holding Register 0x5D SNMP Trap Address0 3
Holding Register 0x5E SNMP Trap Address1 0
Holding Register 0x5F SNMP Trap Address1 1
Holding Register 0x60 SNMP Trap Address1 2
Holding Register 0x61 SNMP Trap Address1 3
Holding Register 0x62 SNMP Trap Address2 0
Holding Register 0x63 SNMP Trap Address2 1
Holding Register 0x64 SNMP Trap Address2 2
Holding Register 0x65 SNMP Trap Address2 3
Holding Register 0x66 SNMP Trap Address3 0
Holding Register 0x67 SNMP Trap Address3 1
Holding Register 0x68 SNMP Trap Address3 2
Holding Register 0x69 SNMP Trap Address3 3
Holding Register 0x6A TCP Port
Holding Register 0x6B Communication Cfg
Holding Register 0x6C CBF current mode
Holding Register 0x6D CBF current status
Holding Register 0x6E CBF current alarm
Holding Register 0x6F CBF msrd power in KW
Holding Register 0x70 CBF msrd inlet temp
Holding Register 0x71 CBF msrd exhaust temp
Holding Register 0x72 CBF msrd flow rate
Holding Register 0x73 CBF msrd delta t
Holding Register 0x74 CBF fahrenheit / celsius
Holding Register 0x75 CBF set power
Holding Register 0x76 CBF set delta t
Holding Register 0x77 CBF set t exhaust
Holding Register 0x78 CBF set flow rate
Holding Register 0x79 CBF pcr drive voltage
Holding Register 0x7A CBF servo drive voltage
Holding Register 0x7B CBF flow switch
Holding Register 0x7C CBF max measured flow rate

Version 0.01 Page:16 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF Modbus Register Map (cont)


Holding Register 0x7D CBF min measured flow rate
Holding Register 0x7E CBF max measured temp

Version 0.01 Page:17 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB

-- CBF control MIB.


--
-- Author Date Comment
-- ==================================================================
-- Lance Palatini 2/1/14 Initial
--

CB7SYSTEMS DEFINITIONS ::= BEGIN

IMPORTS
enterprises, IpAddress
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB;

on-off ::= INTEGER {


off (0),
on (1)
}

cb7systems OBJECT IDENTIFIER ::= { enterprises 43048 }


product OBJECT IDENTIFIER ::= { cb7systems 1 }
setup OBJECT IDENTIFIER ::= { cb7systems 2 }
control OBJECT IDENTIFIER ::= { cb7systems 3 }

productname OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { product 1 }

productversion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { product 2 }

Version 0.01 Page:18 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB (cont)


versiondate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { product 3 }

trapsTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Trap table"
::= { setup 1 }

trapsEntry OBJECT-TYPE
SYNTAX TrapsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Single trap entry containing trap receiver info."
INDEX { trapReceiverNumber }
::= { trapsTable 1 }

TrapsEntry ::= SEQUENCE {


trapReceiverNumber
INTEGER,
trapEnabled
INTEGER,
trapReceiverIPAddress
IpAddress,
trapCommunity
DisplayString
}

--

trapReceiverNumber OBJECT-TYPE
SYNTAX INTEGER (0..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index of trap receiver"
::= { trapsEntry 1 }

Version 0.01 Page:19 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB (cont)


trapEnabled OBJECT-TYPE
SYNTAX INTEGER {
no (0),
yes (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates if this trap entry is enabled or not."
::= { trapsEntry 2 }

trapReceiverIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap receiver IP address"
::= { trapsEntry 3 }

trapCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..7))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap community to be used by agent to send trap"
::= { trapsEntry 4 }

systemname OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { control 1 }

systemcontact OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { control 2 }

systemlocation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
""
::= { control 3 }

Version 0.01 Page:20 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB (cont)


systemtesttrap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 4 }

systemruntime OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 5 }

systemtemperature OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 6 }

cbftrappedairfail OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 7 }

cbfovertempfail OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 8 }

cbfvoltageimbalance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 9 }

Version 0.01 Page:21 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB (cont)


cbfcurrentimbalance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 10 }

cbfoperationmode OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 11 }

cbfstatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 12 }

cbfalarm OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 13 }

cbfmeasuredtin OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 14 }

cbfmeasuredtout OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 15 }

Version 0.01 Page:22 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB (cont)


cbfmeasuredflow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 16 }

cbfmeasureddeltat OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 17 }

cbfahrenheit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 18 }

cbfmeasuredvoltage OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 19 }

cbfmeasuredcurrent OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 20 }

cbfmeasuredpower OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 21 }

Version 0.01 Page:23 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB (cont)


cbfsetpower OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 22 }

cbfsetflow OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 23 }

cbfsetdeltat OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 24 }

cbfsettout OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 25 }

cbfsetmode OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { control 26 }

trapcbfairfail TRAP-TYPE
ENTERPRISE enterprises
VARIABLES { cbftrappedairfail }
DESCRIPTION
""
::= 1

Version 0.01 Page:24 of 25


CB7 Systems LLC 200016 CBF Load System Specifications

CBF SNMP MIB (cont)


trapcbfovertemp TRAP-TYPE
ENTERPRISE enterprises
VARIABLES { cbfovertempfail }
DESCRIPTION
""
::= 2

cbftrapphaseimbalance TRAP-TYPE
ENTERPRISE enterprises
VARIABLES { cbfphaseimbalance }
DESCRIPTION
""
::= 3

traptest TRAP-TYPE
ENTERPRISE enterprises
VARIABLES { systemtesttrap }
DESCRIPTION
""
::= 4
END

-- This MIB was created using NuDesign Technologies' Visual MIBuilder (Ver 5.2).

Version 0.01 Page:25 of 25