Schedule 2 - 2021 10 06 10 20 23

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Schedule 2

Material Code M2697111100

Material Description EQUIPMENTS & SPARES:EQUIPMENT-PORTABLE PARTICLE COUNTER FOR


OIL:SPEC/SPA MP ASSY
LASER-BASED PARTICLE COUNTER
Laser Particle counter for testing oil cleanliness:
The instrument should be microprocessor-controlled, light-weight, portable,
advanced laser-based particle counter to count and size particles in oil [as per ISO
4406:1999, NAS 1638 and SAE AS 4059D
cleanliness standard] along with all necessary accessories for both
on-line and offline operation. Instrument should be water-proof and corrosion-
resistant.
(i) The instrument should be capable of particle sizing and counting
without dilution of oil sample.
(ii) Microprocessor-controlled multiple automated sampling, analysis,
reporting and data storage-upto 200 measurement data & automatic storage
upto 200 measurement data & automatic storage of analysis set up.
(iii) Sampling system- Automated sampling (preferably assisted by inbuilt
pump with controlled constant flow).
(iv) Sample requirement- 5 ml to 100 ml (max). The analyzer should
not require flushing after each sample run. There should be provision of
reuse of oil samples after run through the instrument.
(v) Viscosity range- upto 150 cst or better.
(vi) Fluid Temperature Range: 0 to 70 deg C
(vii) Count correction: Air bubble removal arrangement & counting
correction facility due to moisture particles & air bubbles.
(viii) Operation/measurement/display- operation using touch screen, with
LCD graphic display. Display should show particle numbers, cleanliness
classes, size etc.
Analyzer should create reports in PDF or Excel format for easy
interpretation and records. Further there should be standard USB port
available for data download.
A compatible software should be provided so that it can be be uploaded
LAPTOP/DESKTOP for smooth running of programme and data transfer
(ix) Integral printer- Inbuilt printer for instant printout or better
(x) Power source- Dual source of power for Lab as well as field
Use:220-250 V AC, 50Hz Rechargeable internal battery
(for 2 hour field operation)
Additional battery for memory back up as per requirement.
(xi) Fluid compatibility - For Standard Mineral Oils, Fire resistant
fluids (FRF)/control fluids etc.
(xii) Online application: Instrument shall be capable to measure NAS
value for real-time analysis, required accessories shall be part of the instrument.
(xiii)Off line application: Instrument shall be capable to analyse the
samples off line shall include all accessories for offline analysis.
(xiv) Memory- at least upto 200 measurement data storage and upto 10
automatic analysis set up, data transfer facility should be present.
(xv) Calibration – Instrument shall be factory calibrated & traceable to NIST.
Calibration certificates, in original, have to be supplied by the Bidder. Facility for
recalibration/calibration check option as & when required should be present in
system. Calibration standard traceable to NIST shall be supplied along with the
instrument for two years.
requirement.
Subsequent calibration of the instrument at NTPC laboratory is to be
ensured by supplier/authorized agent in coming year of its use.
(xvi)The instrument should be complete with adapter cable for recharging
and power cable, volatage stabilizer, suitable carry case, printer roll
(at least 10 Nos) and all other accessories as per requirement
(including sample preparation accessories viz. ultrasonic bath,
degassing unit etc).
(xvii)Operation cum maintenance/service manual copies (2 copies each)
(xviii)Installation/Commissioning/Training/Warrantee:
The instrument is to be installed and commissioned at NTPC Kawas
laboratory and all features of the instrument (including repeatability
and accuracy; calibration and/or internal checking) are to be demonstrat
(through analysis of MOT and other oil samples) through operation
by vendor at NTPC lab along with complete training to staff personnel.
Only oil sample shall be provided by site laboratory; rest of the
requirements are to be fulfilled by vendor / their authorized agent for
showing performance of the instrument.
one year on-site warrantee for smooth operation of instrument is to
provided by supplier/their authorized agent from the date of
commissioning of instrument at site.
The supplier shall be responsible to provide support for maintenance and
ensure availability of required spares for the instrument for a period
five years after completion of warranty period.