Professional Documents
Culture Documents
SMU02B V500R002C20SPC005 One Key Upgrade Guide
SMU02B V500R002C20SPC005 One Key Upgrade Guide
Issue 1
Date 2014-06-24
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees
or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Purpose
This document describes how to upgrade SMU02B V2 version or Upgraded version of
SMU02B V2 version via Web/NetEco to SMU02B V500R002C20SPC005 and provides the
common-fault rectification methods, operations, and tool use guide.
Intended Audience
This document is intended for upgrade personnel. Upgrade personnel must:
Be familiar with the product networking and related SMU versions.
Have device maintenance experience and be familiar with device operation and
maintenance.
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol Conventions
Symbol Description
Symbol Description
Contents
Before upgrading, if using Upgrade Tool to upgrade, make sure that our customer promises us
to connect their power system with personal computer, otherwise don't upgrade software of
their power system.
Upgrade SMU02B By Upgrade Tool SMU02B V500R002C20SPC005 One Key Upgrade Guide
1.4 Precautions
After upgrading SMU02B by Upgrade Tool, its historical data and user-defined parameter
configurations will all be cleared.
If the source version before the upgrade is SMU02B V2 version or Upgraded version of
SMU02B V2 version via Web/NetEco, you need to obtain and feedback the current system
type of the site before the upgrade so that we can provide the corresponding system individual
configuration file, and after the software upgrade is completed must import the corresponding
system individual configuration file provided by us, and manually configure the basic
installation parameters and user-defined parameters according to the actual situation of the
site.
If unexpected issue occurs during upgrade, please re-upgrade or contact to the native TAC.
2.1 Obtain and feedback the current system type of the site
If the source version before the upgrade is SMU02B V2 version or Upgraded version of
SMU02B V2 version via Web/NetEco, you need to obtain and feedback the current system
type of the site before the upgrade so that we can provide the corresponding system individual
configuration file.
Methods:
a. Feedback the BOQ or contract number of the current power system.
b. Feedback the label of the current power system cabinet, for example:
c. Export and feedback the E-label of the current power system on SMU02B WebUI.
Step 2 Click “Sure”, and immediately simultaneously press and hold the “Enter” key and the
“Down” key on the monitor panel until the LCD displays language selection interface:
If the upgrade tool has been opened or the TFTP service of the PC is working, it will be failed
as shown in the below picture:
Solution:
a. Check whether the upgrade tool has been opened, if it does, close all the opened
windows and open the upgrade tool again.
b. If the upgrade tool hasn’t been opened, check whether the TFTP service of the PC
has been opened, if it does, close all the service and open the upgrade tool again.
This step will take 20mins, and the dialog message will pop up after upgrading successfully.
Expected Results
The current version information is consistent with software package.
Expected Results
The current version information is consistent with software package.
Troubleshooting
If no configuration information is displayed, please refresh the page.
Wait for the SMU02B restart, log in SMU02B WebUI again and verify the system type(take
ETP48200 as an example):