Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

MAGBIT 4

Reg. Owner: BOYACA NAVIGATION INC


BV Reg. Nr: 23939X
Vessel Type: Special service
Date of build: 30 Sep 2013
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Table of Contents

Ship Particulars
Owner / Manager Information
Class / Statutory Status
Planned Inspection Items
1-Year Survey Planner
Regulatory Information
Bureau Veritas Contacts

The latest published Rules of the Bureau Veritas Marine & Offshore and the Terms of use are applicable
La dernière édition des règlements de Bureau Veritas Marine & Offshore ainsi que les Conditions Générales d'utilisation sont applicables

The information entered on the classification certificate takes precedence over Les informations portées au certificat de classification font foi vis-à-vis des
the statements issued periodically, or on request, by the Society on class status informations émises périodiquement, ou sur demande, par la société, sur la
and surveys passed or due. It is the Owner's responsibility to apply for the position de la classe du bateau et les visites effectuées ou dues. Il incombe
surveys provided for in the rules to avoid any inconvenience which is liable to à l'Armateur de formuler une demande pour que soient effectuées les visites
result from the suspension or withdrawal of class. prescrites dans les Règlements pour éviter les inconvénients pouvant résulter
de la suspension ou du retrait de la classe.
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Ship Particulars
Identification
Vessel Type: Special service Flag: COLOMBIA
Port of Registry: BARRANQUILLA

Classification
Class Symbols: I 5 IN(1,2) (-)
Service Notations: Special service Product carrier -no propulsion
Navigation Not.: IN; Navigation on Magdalena river
Machinery: MC

Hull
Deadweight: 2452 ton Builder: 3.MAJ BRODOGRADILISTE d.d.
Overall Length: 59.48 m Country of build: CROATIA
LPP: 59.48 m Date of build: 30 Sep 2013
Breadth: 16 m Hull Material: Mild Steel
Depth: 4.6 m Hull Info: Double Hull
Draught: 3.35 m 1 continuous deck(s)

Machinery
Propelling type: Non-propelled Elec. installation: 1 Diesel generator
42 kVA (34 kW), 440 V, 60 Hz
1 Diesel generator
250 kVA (200 kW), 440 V, 60 Hz
1 Diesel generator
50 kVA (40 kW), 440 V, 60 Hz
Boiler(s): 2 Oil Fired Auxiliary boilers
19.90 m², 10 bar

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 1 / 1
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Owner / Manager Information


Registered Owner
Name: BOYACA NAVIGATION INC
Company Number: 94660
Address: BOYACA NAVIGATION INC
CALLE 53E- URBANIZACION MARBELLA
TORRE MMG, PISO16
Panama City
PANAMA

Manager
Name: Impala Terminals Colombia S.A.S.
Company Number: 92692
Address: Impala Terminals Colombia S.A.S.
Carrera 55 No. 100 - 51 Piso 8
C. Comercial & Empresarial Blue Gardens
Barranquilla
COLOMBIA

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 1 / 1
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Class / Statutory Status


The Class / Statutory Status below shows the information available in VeriSTAR Info database at the time the report is printed.
This may not indicate certificates issued, surveys carried out or recommendations issued but not yet reported to BV Head Office.

Classification
Status: Active

Certificates
Certificate name Issued Expiry Extended Type Status
Classification
Class Certificate 29 Sep 2018 30 Sep 2019 Definitive

Legend:
Expired Expires in less than 1 month Expires in less than 3 months

Surveys / Audits / Inspections


Classification Surveys
Survey name Last Due Date Range (from, to) Postponed Status

Hull - Renewal 30 Sep 2013 30 Sep 2018 30 Sep 2019 30 Sep 2019 Within window
Hull - Intermediate 03 Aug 2017
Hull - Class Extension 29 Sep 2018
Bottom Survey in Dry Dock 30 Sep 2013 30 Sep 2018 30 Sep 2019 30 Sep 2019

Machinery - Renewal 30 Sep 2013 30 Sep 2018 30 Sep 2019 30 Sep 2019
Machinery - Class Extension 29 Sep 2018
Machinery - Intermediate 03 Aug 2017

Legend:
Overdue Overdue in less than 1 month Within the range

Class / Statutory Recommendations


Class Recommendations - Hull
Rec. Nr Description of Recommendation Due Date Status
CTG0/2018/J5141-H1R BV approved drawings of the sight glasses installed on the cargo 29 Dec 2018 Overdue
tanks hatch covers to be presented.
CTG0/2018/J5141-H2R Indented starboard side shell plating IWO. sheerstrake & strake 30 Sep 2019
below sheerstrake and starboard main deck outboard strake
between Fr. 26-32, VS4S to be permanently repaired at the next
dry-dock.
CTG0/2018/J5141-H3R Indented starboard side shell plating IWO. sheerstrake and 30 Sep 2019
starboard main deck outboard strake between Fr. 23-26, VS4S to be
permanently repaired at the next dry-dock.
CTG0/2018/J5141-H4R Indented port side main deck outboard strake between Fr. 50 - 51, 30 Sep 2019
VS2P to be permanently repaired at the next dry-dock.
CTG0/2018/J5141-H5R Indented main deck port outboard strake between Fr. 72 - 74, VS1P 30 Sep 2019
to be permanently repaired at the next dry-dock.
CTG0/2018/J5141-H6R Underwater parts of the hull should be inspected closely from inside 29 Dec 2018 Overdue
void spaces.

Legend:
Overdue Overdue in less than 1 month Limit date in less than 3 months

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 1 / 2
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Class / Statutory Recommendations


Class Recommendations - Machinery
Rec. Nr Description of Recommendation Due Date Status
CTG0/2018/J5141-M1R Cargo tanks high level and overfill alarms lights and horn on deck 29 Dec 2018 Overdue
are not working. To be repaired and tested.
CTG0/2018/J5141-M2R Boilers No. 1 & 2 and thermal oil pumps No. 1 & 2 to be tested. 29 Dec 2018 Overdue

Legend:
Overdue Overdue in less than 1 month Limit date in less than 3 months

Memoranda
Issued Description of Memoranda
02 Oct 2013 The fixed firefighting system is not fitted on the deck. It is assumed that eventual fire on the deck will be extinguished by
pusher during navigation or by shore terminal facilities during cargo loading and discharging.

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 2 / 2
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Planned Inspection Items


Class Items
Hull
Item Nr Date Type VS* Inspection Item Due Date Action Date
CTG0/2018/J5141-H1O 29 Sep 2018 Obs 1 Damaged IMO symbols to be replaced as 29 Dec 2018
necessary.
CTG0/2018/J5141-H1R 29 Sep 2018 Rec 2 BV approved drawings of the sight glasses 29 Dec 2018
installed on the cargo tanks hatch covers to be
presented.
CTG0/2018/J5141-H2R 29 Sep 2018 Rec 2 Indented starboard side shell plating IWO. 30 Sep 2019
sheerstrake & strake below sheerstrake and
starboard main deck outboard strake between Fr.
26-32, VS4S to be permanently repaired at the
next dry-dock.
CTG0/2018/J5141-H3R 29 Sep 2018 Rec 2 Indented starboard side shell plating IWO. 30 Sep 2019
sheerstrake and starboard main deck outboard
strake between Fr. 23-26, VS4S to be permanently
repaired at the next dry-dock.
CTG0/2018/J5141-H4R 29 Sep 2018 Rec 2 Indented port side main deck outboard strake 30 Sep 2019
between Fr. 50 - 51, VS2P to be permanently
repaired at the next dry-dock.
CTG0/2018/J5141-H5R 29 Sep 2018 Rec 2 Indented main deck port outboard strake between 30 Sep 2019
Fr. 72 - 74, VS1P to be permanently repaired at
the next dry-dock.
CTG0/2018/J5141-H6R 29 Sep 2018 Rec 2 Underwater parts of the hull should be inspected 29 Dec 2018
closely from inside void spaces.
Machinery
Item Nr Date Type VS* Inspection Item Due Date Action Date
CTG0/2018/J5141-M1O 29 Sep 2018 Obs 1 Damaged pressure gauge IWO. cargo line 1 Stbd, 29 Dec 2018
located on the cargo manifold midships Stbd. to be
replaced.
CTG0/2018/J5141-M1R 29 Sep 2018 Rec 2 Cargo tanks high level and overfill alarms lights 29 Dec 2018
and horn on deck are not working. To be repaired
and tested.
CTG0/2018/J5141-M2O 29 Sep 2018 Obs 1 C9 auxiliary engine batteries storage box to be 29 Dec 2018
fitted with cover.
CTG0/2018/J5141-M2R 29 Sep 2018 Rec 2 Boilers No. 1 & 2 and thermal oil pumps No. 1 & 2 29 Dec 2018
to be tested.

Statutory Items
None

* Verification Scheme:
1 Inspection/test/report by authorized person and confirmation of action taken through www.veristar.com by the indicated due
date. Documentary evidence to be kept on board. Verification/confirmation by BV Surveyor during next attendance onboard
2 Inspection by BV Surveyor by due date

Legend:
Recommendation overdue Observation overdue
Recommendation overdue in less than 1 month Observation overdue in less than 1 month
Recommendation with limit date in less than 3 months Observation with limit date in less than 3 months
Recommendation with action taken – To be confirmed Observation with action taken – To be confirmed

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 1 / 1
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

1-Year Survey Planner


Class Surveys
Survey name Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan

Hull - Renewal
Bottom Survey in Dry Dock
Machinery - Renewal

Class / Statutory Recommendations


Recommendation desc. Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan

Class Recommendations - Hull


CTG0/2018/J5141-H1R - BV approved
drawings of the sight glasses installed
on the cargo tanks hatch c (...)

CTG0/2018/J5141-H2R - Indented starboard


side shell plating IWO. sheerstrake & strake
below sheerstr (...)

CTG0/2018/J5141-H3R - Indented starboard


side shell plating IWO. sheerstrake and
starboard main deck (...)

CTG0/2018/J5141-H4R - Indented port side


main deck outboard strake between Fr. 50 - 51,
VS2P to be p (...)

CTG0/2018/J5141-H5R - Indented main deck


port outboard strake between Fr. 72 - 74, VS1P
to be perma (...)

CTG0/2018/J5141-H6R - Underwater
parts of the hull should be inspected
closely from inside void spac (...)

Class Recommendations - Machinery


CTG0/2018/J5141-M1R - Cargo tanks
high level and overfill alarms lights and
horn on deck are not wor (...)

CTG0/2018/J5141-M2R - Boilers No. 1


& 2 and thermal oil pumps No. 1 & 2 to
be tested.

Observations
Item desc. Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan

Class Observations - Hull


CTG0/2018/J5141-H1O - Damaged
IMO symbols to be replaced as
necessary.
Class Observations - Machinery

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 1 / 2
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Observations
Item desc. Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan

CTG0/2018/J5141-M1O - Damaged
pressure gauge IWO. cargo line 1 Stbd,
located on the cargo manifold m (...)

CTG0/2018/J5141-M2O - C9 auxiliary
engine batteries storage box to be fitted
with cover.

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 2 / 2
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Regulatory Information

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 1 / 1
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X

Bureau Veritas Contacts


Connecting Office
Office: BV CARTAGENA DE INDIAS
Address: EDIFICIO CENTRO EJECUTIVO BOCAGRANDE
Cra 3a. N° 8-129 Oficina 12-04
CARTAGENA - COLOMBIA
COLOMBIA
Phone: (57-5) 665 2991
Fax: (57-5) 665 2956
Email: jose.chong@pa.bureauveritas.com

Website:
URL: www.veristar.com
Contents: Ship status (complete or "to-do" list)
Ship status dashboard and graphic survey planner
Fleet status
Survey reports
Class & Statutory Certificates issued by BV
Other certificates (uploaded by the owner/manager)
Register of Ships
Full text of BV Rules
On-line request for attendance
On-line request for survey check-list
On-line request for class attestation
Class & Statutory news

Bureau Veritas Marine & Offshore


Generated on 02 Jan 2019 Page 1 / 1
Bureau Veritas Marine & Offshore
Marine website: http://www.veristar.com
Email: veristarinfo@bureauveritas.com
INLAND NAVIGATION MANAGEMENT
Mechelsesteenweg 128-136
B-2018 Antwerp - Belgium
Tel: +32 (0) 3 247 94 00
Tel: +32 (0) 2 247 94 70
Email: dni.mo@bureauveritas.com

You might also like