Professional Documents
Culture Documents
Magbit 4: Reg. Owner: Boyaca Navigation Inc BV Reg. NR: 23939X Vessel Type: Special Service Date of Build: 30 Sep 2013
Magbit 4: Reg. Owner: Boyaca Navigation Inc BV Reg. NR: 23939X Vessel Type: Special Service Date of Build: 30 Sep 2013
Table of Contents
Ship Particulars
Owner / Manager Information
Class / Statutory Status
Planned Inspection Items
1-Year Survey Planner
Regulatory Information
Bureau Veritas Contacts
The latest published Rules of the Bureau Veritas Marine & Offshore and the Terms of use are applicable
La dernière édition des règlements de Bureau Veritas Marine & Offshore ainsi que les Conditions Générales d'utilisation sont applicables
The information entered on the classification certificate takes precedence over Les informations portées au certificat de classification font foi vis-à-vis des
the statements issued periodically, or on request, by the Society on class status informations émises périodiquement, ou sur demande, par la société, sur la
and surveys passed or due. It is the Owner's responsibility to apply for the position de la classe du bateau et les visites effectuées ou dues. Il incombe
surveys provided for in the rules to avoid any inconvenience which is liable to à l'Armateur de formuler une demande pour que soient effectuées les visites
result from the suspension or withdrawal of class. prescrites dans les Règlements pour éviter les inconvénients pouvant résulter
de la suspension ou du retrait de la classe.
VeriSTAR Info Survey Status Report
Vessel name: MAGBIT 4 BV Nr: 23939X
Ship Particulars
Identification
Vessel Type: Special service Flag: COLOMBIA
Port of Registry: BARRANQUILLA
Classification
Class Symbols: I 5 IN(1,2) (-)
Service Notations: Special service Product carrier -no propulsion
Navigation Not.: IN; Navigation on Magdalena river
Machinery: MC
Hull
Deadweight: 2452 ton Builder: 3.MAJ BRODOGRADILISTE d.d.
Overall Length: 59.48 m Country of build: CROATIA
LPP: 59.48 m Date of build: 30 Sep 2013
Breadth: 16 m Hull Material: Mild Steel
Depth: 4.6 m Hull Info: Double Hull
Draught: 3.35 m 1 continuous deck(s)
Machinery
Propelling type: Non-propelled Elec. installation: 1 Diesel generator
42 kVA (34 kW), 440 V, 60 Hz
1 Diesel generator
250 kVA (200 kW), 440 V, 60 Hz
1 Diesel generator
50 kVA (40 kW), 440 V, 60 Hz
Boiler(s): 2 Oil Fired Auxiliary boilers
19.90 m², 10 bar
Manager
Name: Impala Terminals Colombia S.A.S.
Company Number: 92692
Address: Impala Terminals Colombia S.A.S.
Carrera 55 No. 100 - 51 Piso 8
C. Comercial & Empresarial Blue Gardens
Barranquilla
COLOMBIA
Classification
Status: Active
Certificates
Certificate name Issued Expiry Extended Type Status
Classification
Class Certificate 29 Sep 2018 30 Sep 2019 Definitive
Legend:
Expired Expires in less than 1 month Expires in less than 3 months
Hull - Renewal 30 Sep 2013 30 Sep 2018 30 Sep 2019 30 Sep 2019 Within window
Hull - Intermediate 03 Aug 2017
Hull - Class Extension 29 Sep 2018
Bottom Survey in Dry Dock 30 Sep 2013 30 Sep 2018 30 Sep 2019 30 Sep 2019
Machinery - Renewal 30 Sep 2013 30 Sep 2018 30 Sep 2019 30 Sep 2019
Machinery - Class Extension 29 Sep 2018
Machinery - Intermediate 03 Aug 2017
Legend:
Overdue Overdue in less than 1 month Within the range
Legend:
Overdue Overdue in less than 1 month Limit date in less than 3 months
Legend:
Overdue Overdue in less than 1 month Limit date in less than 3 months
Memoranda
Issued Description of Memoranda
02 Oct 2013 The fixed firefighting system is not fitted on the deck. It is assumed that eventual fire on the deck will be extinguished by
pusher during navigation or by shore terminal facilities during cargo loading and discharging.
Statutory Items
None
* Verification Scheme:
1 Inspection/test/report by authorized person and confirmation of action taken through www.veristar.com by the indicated due
date. Documentary evidence to be kept on board. Verification/confirmation by BV Surveyor during next attendance onboard
2 Inspection by BV Surveyor by due date
Legend:
Recommendation overdue Observation overdue
Recommendation overdue in less than 1 month Observation overdue in less than 1 month
Recommendation with limit date in less than 3 months Observation with limit date in less than 3 months
Recommendation with action taken – To be confirmed Observation with action taken – To be confirmed
Hull - Renewal
Bottom Survey in Dry Dock
Machinery - Renewal
CTG0/2018/J5141-H6R - Underwater
parts of the hull should be inspected
closely from inside void spac (...)
Observations
Item desc. Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan
Observations
Item desc. Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan
CTG0/2018/J5141-M1O - Damaged
pressure gauge IWO. cargo line 1 Stbd,
located on the cargo manifold m (...)
CTG0/2018/J5141-M2O - C9 auxiliary
engine batteries storage box to be fitted
with cover.
Regulatory Information
Website:
URL: www.veristar.com
Contents: Ship status (complete or "to-do" list)
Ship status dashboard and graphic survey planner
Fleet status
Survey reports
Class & Statutory Certificates issued by BV
Other certificates (uploaded by the owner/manager)
Register of Ships
Full text of BV Rules
On-line request for attendance
On-line request for survey check-list
On-line request for class attestation
Class & Statutory news