Proposed Pavilion Plan Technical Drawings
Proposed Pavilion Plan Technical Drawings
Proposed Pavilion Plan Technical Drawings
FLOOR PLAN
REFLECTED CEILING PLAN
ROOF PLAN
A-1 FRONT ELEVATION
District / City / Municipality
REAR ELEVATION
RIGHT ELEVATION
LEFT ELEVATION
SECTION THRU A
SECTION THRU B
1
CS
PERSPECTIVE
SCALE NTS
STRUCTURAL LAND USE AND ZONING
FOUNDATION PLAN
S-1 ROOF FRAMING LAYOUT
C-F DETAIL
W-F DETAIL
S-2 ROOF BEAM DETAIL
SLAB DETAIL
ROOF SECTION DETAIL
LINE AND GRADE
ELECTRICAL
LIGHTING LAYOUT
POWER LAYOUT
RISER DIAGRAM
STRUCTURAL
3
CS
SITE
SCALE
DEVELOPMENT PLAN
1:500M
2
CS
VICINITY
SCALE
MAP
NTS
SANITARY
ARCHITECT - OF - RECORD PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
IMPORTANT: PRC NO. 0043119 DESIGNED BY JLT
CS
DATE 01/23/2021
PROPOSED PAVILION PLAN CAD BY CJT
AR. JOHN LAWRENCE S. TING, UAP PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9266 Section 33 DESIGNER NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
ADDRESS Calapan City APPROVED DATE 17/NOV/2021
B
A
4
A1 SCALE
FRONT ELEVATION
1:200M
5 RIGHT ELEVATION
A1 SCALE 1:200M
1 FLOOR PLAN
A1 SCALE 1:200M 30cm x 60cm Wall Tiles 30cm x 60cm Wall Tiles
3
A1 SCALE
ROOF PLAN
1:250M
8
A1 SCALE
SECTION THRU1:200M
A 9 SECTION THRU B
A1 SCALE 1:200M
2 REFLECTED CEILING PLAN
A1 SCALE 1:200M
ARCHITECT - OF - RECORD PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
IMPORTANT: PRC NO. 0043119 DESIGNED BY JLT
A1
DATE 01/23/2021
PROPOSED PAVILION PLAN CAD BY CJT
AR. JOHN LAWRENCE S. TING, UAP PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
Republic Act No. 9266 Section 33 DESIGNER NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
ADDRESS Calapan City APPROVED DATE 17/NOV/2021
4-16mm VERTICAL BARS
W/ 10mm LATERAL TIES SPACED
@ 2-50,2-100,3-150 mm; REST
AT 200mm ON CENTER
TB-1
F.F.L. @ 2-50,2-100,3-150 mm; REST
AT 200mm ON CENTER
VERIFY
N.G.L.
100 mm THK CONCRETE SLAB
VARIES
4"THK CONCRETE SLAB WITH
12MM Ø REINFORCEMENT BARS
@ 400MM SPACING
TB-1
TB-1
8- 16mm TEMP. BARS
BOTH WAYS
250
TB-1
1.2mm x 50mm x 75m 1.2mm x 50mm x 75m
C-PURLINS SPACED
@600mm O.C.B.W.
C-CHANNEL RAFTERS 3 COLUMN 1 FOOTING 1 DETAILS
S1 SCALE 1:30M
VERIFY
GAUGE # 26 RIB TYPE ROOF CONCRETE SLAB
F.F.L.
1.2mm x 50mm x 100mm
N.G.L.
C-PURLINS 3 - 12 mm
VARIES
CONTINUOUS BARS
50mm x 50mm
ANGLE BAR 10 mm TRANSVERSE
200
BARS @ 300 mm O.C. B.W.
4
S1 SCALE
WALL FOOTING DETAIL
1:30M
L1
150 x 200mm L2 / 4
1000
1.2mm x 50mm x 50mm CONCRETE BEAM
ANGLE BAR WEB MEMBER
1.2mm x 50mm x 75mm
C-CHANNEL RAFTERS
ALL SLAB THICKNESS SHALL BE 125mm THK.
1119
UNLESS OTHERWISE STATED.
S1
DATE 01/23/2021
PROPOSED PAVILION PLAN CAD BY CJT
AR. JOHN LAWRENCE S. TING, UAP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
DESIGNER NAME & SIGNATURE NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
Republic Act No. 9266 Section 33 ADDRESS Calapan City APPROVED DATE 17/NOV/2021
1
E1
POWER
SCALE
LAYOUT PLAN
1:50M
2
E1
LIGHTING
SCALE
LAYOUT PLAN
1:50M
IMPORTANT: ARCHITECT - OF - RECORD PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
E1
DATE 01/23/2021
PROPOSED PAVILION PLAN CAD BY CJT
AR. JOHN LAWRENCE S. TING, UAP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
DESIGNER NAME & SIGNATURE P.E.E. NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
Republic Act No. 9266 Section 33 ADDRESS Calapan City APPROVED DATE 17/NOV/2021
GENERAL NOTES
1. THE ELECTRICAL INSTALLATION HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION
OF THE PHILIPPINE ELECTRICAL CODE, THE LOCAL RULES AND REGULATIONS AND THE REQUIREMENTS OF THE UTILITY
COMPANY.
2. ALL ELECTRICAL WORKS HEREIN SHALL BE EXECUTED BY EXPERIENCED MEN UNDER THE SUPERVISION OF A DULY
Ckt Size of
Load Description WATTS AMPS Volts AT Size of Wire REGISTERED ELECTRICAL ENGINEER. WORKS SHALL BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY
No. Conduits FINISHED.
1 COMMON AREAS & GENSET ROOM 2300 10.00 230 20AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 20mm Ø Conduit 3. SERVICE ENTRANCE SHALL BE SINGLE - PHASE, TWO - WIRE PLUS GROUND, 230V, 60Hz.
4. MATERIALS SHALL BE NEW AND SHALL CONFORM WITH THE PROVISIONS OF THE UNDERWRITERS LABORATORIES INC., IN
2 PP-WH 8466 36.81 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit
EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED.
3 PP-SH 6216 27.03 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit 5. ALL CONDUITS EMBEDDED IN CONCRETE SHALL BE PVC, WHILE CONDUITS ABOVE CEILING OR WOOD PARTITION SHALL
4 PP-SQ 2662 11.57 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit BE ELECTRIC METAL TUBING.(EMT)
6. ELECTRICAL TRADE SIZE SHALL BE USED, A MINIMUM OF 15mmØ FOR METALLIC CONDUITS, 20mmØ FOR NON-METALLIC
5 PP-PV 615 2.67 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit
CONDUITS AND IN NO CASE SHALL BE THERE BE MORE THAT THE EQUIVALENT OF FOUR QUARTER BENDS IN ANY ONE
6 PP-AD 12018 52.25 230 60AT/100AF 2P 2-14 mm² THHN Cu. WIRE 25mm Ø Conduit RUN.
7 SPARE 40AT/100AF 2P
7. CONDUITS SHALL BE PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. ALL ENDS OF CONDUITS SHALL BE
PLUGGED TO PREVENT THE ENTRANCE OF WATER, MOISTURE AND FOREIGN MATTER AFTER INSTALLATION.
8 SPARE 40AT/100AF 2P
8. SINGLE CONDUCTOR INSULATED THERMOPLASTIC, 600V WIRES SHALL BE USED IN CONDUIT, MINIMUM SIZE OF WIRES
TOTAL: 32277 140.33 SHALL BE 3.5mm² OR 2.0mmØ THW/TW FOR ALL LIGHTING AND POWER SYSTEM.
MAIN : 225 AMPS 2-POLE LUGS ONLY 2-125 mm² THHN Cu. WIRE IN 50mmØ CONDUIT
9. UPON COMPLETION OF ELECTRICAL CONSTRUCTION WORK, THE FOLLOWING TESTS SHALL BE PERFORMED BY THE
CONTRACTOR INCLUSIVE OF THE INSTALLATION TO BE REPORTED IN DETAILS ON FORM APPROVED BY THE OWNER'S
REPRESENTATIVE: A. INSULATION RESISTANCE TEST, 500VDC.
B. GROUND RESISTANCE TEST (5 OHMS)
C. OPERATIONAL TEST
10. COLOR CODING OF WIRES SHALL BE AS FOLLOWS:
Ckt Size of LINE 1 - BLACK GROUND - GREEN
Load Description WATTS AMPS Volts AT Size of Wire
No. Conduits LINE 2 - BLACK CONTROL 1 - WHITE
1 L.O.(3) & C.O. (3) 615 2.67 230 20AT/100AF 2P 2-3.5 mm² THHN Cu. WIRE 15mm Ø Conduit
CONTROL 2 - BLUE
2 SPACE 2P
3 SPACE 2P
LOAD COMPUTATION:
TOTAL LOAD CURRENT = LINE CURRENT x 1.25 x D.F
TOTAL LOAD CURRENT = 2.67A x 1.25 x 0.90 = 3.01A
USE 60AT/100AF 2P 230V MAIN CB
USE 2-14mm² THHN CU. WIRE IN 25mmØ PVC CONDUIT MAIN FEEDER 4
E1
SCHEDULE OF LOADS
5
E1
SINGLE LINE DIAGRAM 3 VICINITY MAP
E3 SCALE NTS
IMPORTANT: ARCHITECT - OF - RECORD PROFESSIONAL ELECTRICAL ENGINEER PROJECT TITLE OWNER NAME REVISIONS CHECKED BY: DATE SHEET CONTENT PAGE NO.
PRC NO. 0043119 DESIGNED BY JLT
E2
DATE 01/23/2021
PROPOSED PAVILION PLAN CAD BY CJT
AR. JOHN LAWRENCE S. TING, UAP
PLACE Calapan City GOOD HEART MARKETING INC. AS SHOWN
TIN NO. 447-767-640-000 MS. PERLITA N. DE MESA CHECKED BY JLT
DESIGNER NAME & SIGNATURE P.E.E. NAME & SIGNATURE Location: BRGY. PALHI, CALAPAN CITY, OR. MINDORO BRGY. PALHI, CALAPAN CITY
Republic Act No. 9266 Section 33 ADDRESS Calapan City APPROVED DATE 17/NOV/2021