FIRE FIGHTING UNIT

BRENTAS M. LTD
FIRE FIGHTING UNIT

All fire-fighting pumping units are delivered pre-assembled on a base plate,


mounted via vibration dampers.
They are ready for hydraulic and electrical installation.
The customer is required to perform the hydraulic connection of the manifolds
with the fire fighting piping network
and the electrical connection of the control panel of the unit.

35, New Monastiriou str.


56334 Thessaloniki - Greece
tel.: +30 2310 559.000 - 1 - 2
FAX: 2310 559.003
e-mail: info@brentas.gr
www.brentas.gr
DIAGRAM OF FIRE FIGHTING UNIT TECHNICAL DESCRIPTION

FIRE FIGHTING UNIT – CONFIGURATION 1 1. Diesel pumping unit


17 Centrifugal single or multistage pump, chosen according to required flow rate and pressure.
16
It is manufactured according to the highest standards and complies with C.E. directives.
18
Diesel engine models can be water or air-cooled, ranging up to 90 HP, and are chosen at 20%
15 more power than required for the given application. Electric starting via battery
of sufficient amperage.
2. Primary electric pumping unit
14 From fire hydrant 1. Water tank Centrifugal single or multistage pump, chosen according to required flow rate and pressure.
4 8 6 2. Mechanical float switch
3. Water tank gate valve It is manufactured according to the highest standards and complies with C.E. directives.
4. Primary pump suction gate valve
(ball valve upon request)
Electric engine at 2900 rpm, 380V, IP54, class F, Y-Δ starting. The engine is sized according
10
5. Intake manifold to pump specifications. The unit may be in MONOBLOC configuration or coupled.
From water mains supply 6. Primary pump discharge gate valve
or water bore 4 9 7 (ball valve upon request) 3. JOKEY electric pumping unit
7. Jokey pump discharge gate valve
(ball valve upon request) Centrifugal single or multistage pump, chosen according to required flow rate and pressure head.
2 8. Primary pump check valve
5 11 13 9. Jokey pump check valve Normally, the Jokey pump delivers small flow rate at higher pressure than the primary pump
10. Primary electric booster pump
11. Jokey electric booster pump and is used to keep the piping network pressurized. The pump may be horizontal or vertical,
3 4 8 6 12. Diesel engine driven booster pump
1
To fire fighting
13. Discharge manifold 220V or 380V. It is manufactured according to the highest standards and complies
piping network
14. Pressure tank valve
15. Pressure tank
with C.E. directives.
Note: Water tank, float switch and 12 16. Pressure control
water tank valve are not included
17. Manometer
4. Pressure vessel
in the supply of the pumping unit

Piping drainage 18. Control panel Equipped with EPDM membrane, which offers long product life and endurance.
The vessel is epoxy painted to ensure maximum protection against corrosion.
Capacity ranges from 100 to 500 lt.
5. Battery
FIRE FIGHTING UNIT – CONFIGURATION 2 Included in the supply and mounted on a special support on the unit’s base plate.
17
6. Control panel
16
Water proof, IP54 protection, constructed of DKP steel sheet. It includes all necessary electronic
18
and electric equipment for the fully automated operation of the fire fighting unit. A battery charger
15 is also included to keep the battery of the diesel engine charged continuously.
7. Controls and fittings, pressure switches, manometers, piping, valves, check valves,
1. Water tank
2. Mechanical float switch manifolds etc
14 From fire hydrant
3. Water tank gate valve
4. Primary pump suction gate valve TECHNICAL CHARACTERISTICS
4 8 6 (ball valve upon request)
5. Intake manifold POWER PRESSURE FLOW RATET PRESSURE DN WEIGHT DIMENSIONS
6. Primary pump discharge gate valve TYPE VESSEL(LIT) (m3/h) (mWC) (mm) (kgr.)
DIESEL (HP) ELECTRIC (HP) JOKEY (HP) W L H
(ball valve upon request) Χ Χ
10 7. Jokey pump discharge gate valve
(ball valve upon request) BR/10-7,5-1 10 7.5 1 200 15-27-40 52-44-30 90 260 1,1X1,4X1,7
From water mains supply 8. Primary pump check valve
or water bore 4 9 7 BR/12-10-2 12 10 2 200 37-46-52 55-42-27 100 295 1,1X1,4X1,7
9. Jokey pump check valve
10. Primary electric booster pump BR/16-15-2 16 15 2 200 17-39-48 78-60-59 100 355 1,15X1,6X1,7
2 11. Jokey electric booster pump
5 11 13 12. Diesel engine driven booster pump BR/22-20-2 22 20 2 300 40-60-80 70-63-55 100 580 1,5X1,8X1,7
13. Discharge manifold
14. Pressure tank valve BR/27-25-2 27 25 2 300 47-66-80 81-67-58 100 605 1,5X1,8X1,7
3 4 8 6 15. Pressure tank BR/42-30-3 42 30 3 300 51-70-83 81-78-62 100 712 1,5X1,85X1,7
To fire fighting 16. Pressure control
1 piping network 17. Manometer BR/45-40-3 45 40 3 500 62-86-90 87-80-71 100 812 1,6X1,9X1,9
18. Control panel
Note: Water tank, float switch and 12
12 BR/64-50-3 64 50 3 500 51-110-130 97-87-66 125 1100 1,9X2,2X1,9
water tank valve are not included
in the supply of the pumping unit BR/90-75-4 90 75 4 500 52-112-172 141-120-82 150 1212 2X2,3X2
Piping drainage BR/140-100-4 140 100 4 500 75-180-260 150-127-90 150 1525 2X2,6X2