T300 technology board1)

The T300 technology board can be Á winders Á hoisting drives


used to create technological
Á coilers Á drive-related control functions.
functions for various applications
such as: Á synchronous and positioning
control
Á closed-loop tension and position
control

1) Attention!
Only for compact and chassis units.
SIMOVERT MASTERDRIVES Vector Control
Compact and Chassis Units
-
enta
p plem a
u r
Electronics options ch s d fo Compact and chassis units
whi eede
ecifies s are n s
e s p e nt on i
T300 technology board · Components tabl pon ncti in the
tion com e fu
s elec logical to r driv e listed .
e
Th chno sk. o ar ed
Ordering information lti-m hich quir Components required for the Components
ry te cific ta he mu ucts w n are re standard software package required for
spe mple: T ll prod colum self-generated
Exa ired. A r drive
requlti-moto application
mu software, using
Product description Comment Order No. Multi- Axial Angular syn- Posi- STRUC STRUC
motor winder chronous tioning L G
drive control control

T300 technology board with two SC58 and 6SE7090–0XX87–4AH0 Á Á Á Á Á Á


SC60 connecting cables, SE300 terminal
block and G/E hardware instruction manual German/English
T300 technology boards as spare part 6SE7090–0XX84–0AH2 Á Á Á Á Á Á
LBA local bus adapter for MASTERDRIVES Also used to install a 6SE7090–0XX84–4HA0 Á Á Á Á Á Á
electronics box communication board
Additional instruction manual for the T300 German/English 6SE7087–6CX84–0AH1
hardware French 6SE7087–7CX84–0AH1
Standard software package, multi-motor 6SE7098–6XX84–0AH0 Á
drive on an MS360 memory module without
manual
Manual, multi-motor drive2) German 6SE7080–0CX84–6AH1 Á
English 6SE7087–6CX84–6AH1
Multi-motor drive standard softw. package on 6SW1798–6XX84–0AH0
floppy disk in STRUC source code3) MD360
Standard software package, axial winder on 6SE7098–2XX84–0AH0 Á
an MS320 memory module, without manual
Manual, axial winder2) German 6SE7080–0CX84–2AH1 Á
English 6SE7087–6CX84–2AH1
Axial winder standard software package on 6SW1798–2XX84–0AH0
floppy disk in STRUC source code3) MD320
Standard software package, angular 6SE7098–4XX84–0AH0 Á
synchronous control 4) on an MS340
memory module without manual
Manual, angular synchronous German 6SE7080–0CX84–4AH1 Á
control2) English 6SE7087–6CX84–4AH1
French 6SE7087–7CX84–4AH1
Angular synchronous control standard software 6SW1798–4XX84–0AH0
package on floppy disk in STRUC source code3)
MD340
Standard software package, 6SE7098–8XX84–0AH0 Á
positioning control on an MS380 memory
module without manual
Manual, positioning control2) German 6SE7080–0CX84–8AH1 Á
English 6SE7087–6CX84–8AH1
Standard software package, positioning 6SW1798–8XX84–0AH0
control on floppy disk in STRUCr source
code3) MD380

Generation software and accessories for configuring (see Catalog ST DA)


STRUC G/L Version 4.2 on CD-ROM with the See the text
Service IBS start-up program
German/English 6DD1801–1DA2 Á
Configuring PC for STRUC G PT, installed See the text Á
ready to run
Empty MS300 memory module for T300, MS300 6SE7098–0XX84–0AH0 Á Á
8 Kbytes EEPROM or
Empty MS301 memory module for T300, MS301 6SE7098–0XX84–0AH1 Á Á
8 Kbytes EEPROM
Parallel programming unit PPX1, external The same for STRUC L PT 6DD1672–0AD0 Á Á
programming unit, for connection to a printer and G PT
port with power supply unit (for PC/PG) with
UP3 progr. Adapter
PG7x0 connecting cable to T300 Self-assembly according to – Á Á
if Service IBS start-up program is used1) the T300 instruction manual
PC-AT connecting cable to T300 Self-assembly according to – Á Á
if Service IBS start-up program is used1) the T300 instruction manual

1) Depending on whether a SIMATIC-PG or a 2) Order the required number of manuals in the 4) The standard software package is only required
standard PC is used for start-up only one of the desired language, irrespective of the number of for the slave drive(s). Example: Two drives
two cables is required. T300 standard software packages which have which operate in angular synchronism:
been ordered. One standard software package for angular
synchronous control is required.
3) Only required if the standard is to be changed;
requires STRUC configuring software.
SIMOVERT MASTERDRIVES Vector Control
Engineering Information
Compact and chassis units
Technology Cabinet units

Technology applications with the T300


The T300 can be used to pro- The serial connections can
vide additional technological be directly connected to ter-
functions for compact and minals on the T300. All other
chassis units (e.g. for closed- external signals can be con-
loop tension and position nected at the SE300 terminal
control, coilers, winders, block outside the base unit.
closed-loop synchronous 15 V / 100 mA for supplying
and positioning controls, pulses is available at SE300
transverse cutters, hoisting (see Fig. 6/78).
equipment and drive-related An external 24 V DC power
control functions). supply must be provided if
Supplementary technologi- binary inputs and outputs
cal functions which are often have to be controlled. The
requested are offered as base unit can also provide
standard software packages this voltage supply as long as
on pre-programmed memory the total current at terminals
modules. X101.13, 23 of the base unit
The T300 and SIMADYNâ D is < 150 mA.
are fully compatible with The software package is
each other. parameterized – irrespective
Users who wish to create of which software package is
special applications or who used – with the help of the
wish to market their own following:
technological know-how can
create their own technologi- Á a Drive ES or DriveMonitor Fig. 6/77
cal design on the T300 by PC T300 board with memory module
using the graphics-oriented
STRUCâ planning language Á the PMU operator control
known from the SIMADYN D and parameterizing unit
system.
Á the OP1S user-friendly
control unit
Fig. 6/78 shows the most im-
portant hardware functions Á an interface board (CBP,
of the T300. SCB1, SCB2)
The technological functions
are configured with STRUC Á via an interface of the T300
and cyclically executed by with the service start-up
the processor. The closed- program.
loop control sampling time
is a minimum of 1 ms (see Altered parameters can be
Catalog ST DA). stored in the EEPROM
An overview of the hardware (non-volatile).
and software components
of the T300 is provided in
Fig. 6/79.
An almost delay-free parallel
interface (dual-port RAM)
permits data transfer be-
tween the basic unit and
the T300.