Download as pdf
Download as pdf
You are on page 1of 6
HIDRAUTRONICA 118-160-R00 Lv i aT Nags Mechanical Pressure Switches MDS ‘Monitoring the oil pressure is essential in hydraulic systems and oil supply systems, The measurement of maximum or ‘minimum pressure has a direct effect on the safety of the system, the functionality or process reliability. ti important to monitor bath process-related pressure ranges as well as safety shutdowns, load limits or simply to determine ifthe lubricating pressure is adequate. MDS mechanical pressure switches serve system pressure ‘monitoring, They are available with adjustable switch points robust and compact unit, adjustable switch point high degree of accuracy ‘max. operating pressure up to 350 bars (thers upon request) electromechanical signal converter (Miz as well as M3 plug connector as per DIN EN 175301-803, changeover function Jong service life be130203 03/2018 page/6 Buhler Technologies GmbH, Harkortst. 29, -40880 Ratingen Tel. 49 (0) 2102 / 49 89.0, Fax: #49 (0)2102 /49 89-20 E-Mail: Muidcontrol@buehler-techologies com Internet: wivwrbuehler-technologies com ieon | 3 Technical Data MDS Mos Mediums Self-lubricating fluids hydraulic luid and lubricating oils, compressed air Process connection cys" cya Seal Based on DIN3852-E Torque 20NNm 25Nm Principle of Measurement ‘Membrane Piston springsloaded spring-loaded <16bar 210bar ‘max. working pressure 60 bar 350 bar Materials ‘Membrane: NBR Piston: Steel Seal PTFE, NBR Housing Steel, galvanised Steel, galvanised Switching output Changeover contact Quantity 1 Switching element Microswitch with silver-plated contacts ‘max. switching frequency 100/min Switching capacity using plug ma m2 Dcupto28V 28 2A AC up to 250 an ~ ‘Mounting position Any Response ‘min, rate of pressure rise 0.01 bar/s Switching point / accuracy Switching point / reproducibility ‘Ambient / operating temperature range Vibration resistance Shock resistance Switeh-back difference ‘Membrane version +£2% from end value at room temperature same as accuracy 20..480°C ‘AA0G /10-500 Hz 1006/6 ms Piston version 723456780 Setcin ete fait 12 196 15 16 70 Cy ‘0 40 » 0 o 10 4070 10) 190 160 190 220 260 200 310 ‘Satin pot Plug connection 'M3 (DIN EN 175301-803) ‘M2 (base) Somere on vetage zy av Pratt wes wer Caveitng 29 “hence 2 e4 binagmen ern PFN 2 Builer Technologies GmbH We reserve the right to amend specification, 1E130203 + 03/2019 I Dimensions MDS Ma version na version § ay pseel z Co Zp = 4 De Pst soa ys 1omm yA 2mm ‘Accessories: Item no.:9144050047 Connecting cable MI2x1, 4-pin plug, Item no, 9146100159 Electric line box MI2x1, 90° angle ‘Model key MDS Pressure ranges Switching point setting’ (optional) Fluid connection or Gla" Membrane switch 16: 1..16 bar Membrane switch 420: 10...120bar Piston pressure switch 250; 20...250bar Piston pressure switch 320: 30...320bar Piston pressure switch ® necessary, the switching point can be setat the factory. The switching point must be selected with the pressure rising or fal ‘ng, ie. switching point from 0 bar to switching point (rising) or from the max. operating pressure to the switching point (fall- ing). Please refer to the following example for the switching lagic: -MDS-M3-G1/4-120-80R (switching point 80 bar rising): in3-2 closed when switching point reached (MDS-M3-G1/4-120-80F (switching point 80 bar falling): Pin3-1 closed when switching point reached 1E130203 03/2019 (We reserve the right to amend specification, Buhler TechnologiesGmbH 3 kx ay Technical Data MDSM and MDSK Mediums Process connection ‘Mounting position Principle of Measurement ‘max. working pressure min, rate of pressure rise Switching point Accuracy/reproducibility Materials Measuring element Pressure connection Housing Switching output Quantity Switching element ‘max. switching frequency ‘max. switching capacity Mosm Neutral fluids, compressed air Gi/4" internal Any Spring-loaded membrane 60 bar 0.01 bar/s +£2% upper range value at room temp. ‘Membrane: NBR Zine diecasting (GI/ internal) Zine diecasting Changeover contact ‘adjustable with fastener Microswitch with silver-plated contacts 200 / min. Mosk Seif-lubricating fluids such as hydraulic fluids and lubricating oils 61/4" swivel, vertical flange, DIN ISO 16873, torque: 25 Nm any Spring-loaded piston 350 bar 0.01 bar/s +£2% upper range value at room temp. Piston: Stainless steel 1.4305 Galvanised steel (G1/4” swivel), zine diecasting (vertical flange) Zine diecasting Changeover contact 1, adjustable with fastener Microswitch with silver-plated contacts 200 / min. with plug a mz a mz Dc upto 28v BA 3A BA 3A ACupto250V 6A = 6A ~ Ambient conditions Ambient / operating temperature range -10°C.:+80°C -10°C..480°C Vibration resistance ‘A106 /10-500 Hz ‘106,/10-500 He Shock resistance 1006/6 ms {1006/6 ms Weight 03kg 033kg Switchback difference mos Mosk 140 2 10 pe —E_ co $ oa 020 000 T2easeTeswnn DNs © 101s) 200250 O ie snare c Seopa 4° Buhler Technologies mbit We reserve the right to amend specification ‘er30203- 03/2019 Plug connection Max. voltage IPrating Cable fitting Pin assignment (M3 (DIN EN 175301-803) Bepin + PE 250 P65, Pcs Sa Pp Dimensions MDSM and MDSK Dimensions MOSM M3 version Miz (base) apin 2eVv P67" “when connected Electric line box included —_= i ae © L io | = Rigid internal thread Rigid internal thread Dimensions MDSK (M3 version with thread (M3 version with vertical flange DIN ISO 16873 [ 1 = t@1 r eq ® L a 3 er 1 je @ Electric line box included can fa v4 82mm External thread 1130203 - 03/2019 (We reserve the right to amend specification, Buhler TechnologiesGmbH 5 2 version with thread ‘M2 version with vertical flange DIN 15016873, Swivel external thread Accessories: Item no,:9144050047 Connecting cable MI2x1,4-pin plug, L=5m em no:9146100189 Electric line box MT2x1, 90° angle tem no,: 9008429) Double nipple G/4, stainless steel ‘Model key MDSM and MDSK Mos Pressure ranges Switching point setting” Pressure ranges & 05..8bar MOSM 16: 1..18bar = MDSM 120: 10...120 bar MDSK 250: 20..250 bar MDSK 320: 30...320 bar__ MDSK Plug connection M3 or M12. ‘Thread / connection G 1/41 G 1/4" internal (only MOSM) G 114d. G 1/4" swivel (only MDSK) \VF _Vortca ange per ISO 1673 (only MOSK) ® necessary, the switching point can be set at the factory. The switching point must be selected with the pressure rising or fal ing, ie. switching point from 0 bar to switching point (rising) or from the max. operating pressure to the switching point (all- {ng). Please refer to the following example for the switching logic: -MDSK-M3-G1/4-120-80R (switching point 80 bar rising) PINT-3 closed when switching point reached MDSK-M3-G1/4-120-80F (switching point 80 bar falling) PINI-2 closed when switching point reached 6 Buhler Technologies GmbH ‘We reserve the right to amend specification, 1DE130203 - 03/2019

You might also like