CAR PARK
CAR PARK

property line property line


property line property line

1 2 3 4
E-1 GROUND FLOOR LIGHTING LAYOUT E-1 SECOND FLOOR LIGHTING LAYOUT E-1 GROUND FLOOR POWER LAYOUT E-1 SECOND FLOOR POWER LAYOUT

6
GENERAL NOTES
E-1
5 LEGEND MERALCO
E-1
GENERAL NOTES
PB
2 - 8.0 MM2 THWN
& 1 - 5.5 MM2 TW

LEGEND: 1.1. ALL ELECTRICAL WORKS SHALL BE IN ACCORDANCE WITH THE PROVISIONS OF THE LATEST EDITION OF (11)
THE PHILIPPINES ELECTRICAL CODE, THE LAWS AND ORDINANCES OF THE LOCAL CODE, ENFORCING
AUTHORITIES AND THE REQUIREMENTS OF THE LOCAL POWER AND TELEPHONE UTILITY COMPANIES.
DUPLEX CONVENIENCE OUTLET
2. THE CONTRACTOR SHALL SECURE ALL PERMITS AND PAY ALL FEES REQUIRED FOR THE WORK
(220 VOLTS) ON UNIVERSAL SOCKET AND SHALL FURNISHED THE OWNER THROUGHT THE ENGINEERS FINAL CERTIFICATE OF ELECTRIAL
INSPECTION AND APPROVAL FROM PROPER. (7)
WEATHERPROOF DUPLEX CONVENIENCE OUTLET
WP
(220 VOLTS),ON UNIVERSAL SOCKET
3. ALL MATERIAL TO BE USED SHALL BE NEW AND INSTALLED IN APPLICATIONS
FOR WHICH THEY ARE INTENDED.
PVC pipe is acceptable for (8)
LIGHTING 1 2 LIGHTING
SINGLE REFRIGERATOR OUTLET ON
4.
embedded installation. for
ALL CONDUIT PIPES SHALL BE INTERMIDIATE METALLIC CONDUIT (IMC) EXCEPT AS NOTED ON THE
PLANS AND SPECIFICATIONS REFER TO SPECIFICATION FOR INSTALLATION REQUIREMENT.
REF UNIVERSAL SOCKET C.OUTLET 3 4 C.OUTLET
5. MINIMUM SIZE OF CONDUIT SHALL BE 15MM DIAMETER.
cheaper cost
ELECTRICAL PANEL BOARD, REFER TO ELLECTRICAL LIGHTING 5 6 REF
6. ALL CONDUIT SHALL BE CONCEALED UNLESS SPECIALLY SHOWN OR NOTED OTHERWISE EXPOSED
CONSULTANT'S SPECS, TYP,
CONDUIT RUNS SHALL BE INSTALLED PARALLEL TO OR PERPENDICULAR WITH THE BUILDING LINE AND
RANGE 7 8 ACU
SUPPORTED BY THE CONDUIT CLAMPS.

SWITCH LOCATION 1 GANG SWITCH; C.OUTLET 9 10 ACU


S1 HEIGHT: 1.40 M
7. PROVIDE GALVANIZED PULLING WIRE G.A. 18 FOR ALL EMPTY CONDUITS.

8. PULL BOXES SHALL BE PROVIDED BY THE CONTRACTOR WHENEVER NECESSARY TO FACILITATE ACU 11 12 SPARE
WIRE PULLING EVEN IF THESE ARE NOT INDICATED ON THE PLANS.
SWITCH LOCATION 2 GANG SWITCH;
S2 HEIGHT: 1.40 M 9. FOR BOXES WITH MORE THAN FOUR WIRES ENTERING. USE 0.10 M X 0.10 M
SQUARE BOX WITH ONE ADAPTER RING (TYPICAL RECEPTACLE BOXES)

SWITCH LOCATION 3 GANG SWITCH;


S3 HEIGHT: 1.40 M
10. ALL LIGHTING AND CONVENIENCE OUTLET CIRCUITS SHALL BE 3 WIRES 3.5 SQ.
MM THHN UNLESS OTHERWISE NOTED. MINIMUM SIZE OF WIRE SHALL BE 3.5 SQ. MM THHN.

11. ALL DUPLEX RECEPTACLE OUTLET SHALL BEGROUNDING TYPE WITH PARALLEL
3-WAY SWICH LOCATION; 2GANG SWITCH; 1-30.0 MM2 THHN GW
3S HEIGHT: 1.40M
SLOTS FOR 220V.

12. ALL METALLIC CONDUIT, CABINETS, AND EQUIPMENT SHALL BE PROPERLY


GROUND
GROUNDED AND BONDED.
FLUORESCENT LIGHT
13. UNLESS OTHERWISE NOTED MOUNTING HEIGHT FOR WALL MOUNTED DEVICES
SHALL BE AS FOLLOWS:

RECEPTACLE OUTLET – 300 MM AFF.


WALL LAMP

14.
LIGHTING SWITCH – 1370 MM AFF.

INDENTIFICATION OF SYMBOLS APPROPRIATE FOR EACH OF PACKAGE IS NOT


7
PANEL BOARD DETAILS
NOTED TO ASSIST CONTRACTOR FOR QUICK DEVICE AND EQUIPMENT IDENTIFICATION AND E-1
REFERENCE ONLY. CONTRACTOR MUST BE FAMILIARIZE WITH ALL THE SYMBOLS FOR PROPER
EXCUTION OF WORK.

ENGINEER ENGINEER ENGINEER PROJECT TITLE: PROJECT OWNER: SHEET CONTENTS: DESIGNED BY: SHEET NO:

DRAWN BY:
PERSPECTIVE VIEW
PROPOSED 2-STOREY HOUSE

PRC NO. DATE PRC NO. DATE PRC NO. DATE


IMPROVEMENT
PH:2 BLK:1 LOT:11 SAN ANTONIO SOUTH
BRGY. LANGKIWA, BINAN, LAGUNA
VERNADETTE N. CABRILLAS
SAN VICENTE, BINAN, LAGUNA
VICINITY MAP

SITE DEVELOPEMENT PLAN


CHECKED BY:

APPROVED BY:
E-1
REVISION BY:
RTR NO. DATE RTR NO. DATE RTR NO. DATE
T.I.N. PLACE T.I.N. PLACE T.I.N. PLACE DATE REVISED: PROJECT NO: