IMPACT-POWER HYDRAULICS SDN. BHD.

动 能 油 压 有 限 公 司 (Company No. : 280464-V)

IPH750 HYDRAULIC PILING HAMMER


AND RIG

Lot 15828, Jalan Bukit Kemuning, Batu 7, Bukit Kemuning, 42450 Shah Alam, Selangor Darul Ehsan, Malaysia.
Tel. No. : +603 – 5121 9293 Web : www.iph.com.my
Mobile No. : +6012 – 393 6593 Facebook : Impact-Power Hydraulics Sdn Bhd
Fax No. : +603 – 5121 9593 FB Page : IPH
E-mail : iphsb1993@hotmail.com GPS : N 03° 0.878', E 101° 31.056'
Waze : Impact-Power Hydraulics Sdn Bhd
IPH750 HYDRAULIC PILING HAMMER
Main Features
• Can handle pile length up to 12m.
• No heavy crane required during mobilization and demobilization.
• No dismantling of parts during transportation.
• Mounted on excavator type superstructure.
• Easy handling and flexibility.
• Hydraulic brakes for hammer and pile handling operations.
• Patent pending for ball joint, hammer cylinder, hammer ram and connectors, and hydraulic clutch.

Technical Data
Hydraulic Hammer Type 3.0 tons 4.0 tons 5.0 tons 5.5 tons 7.5 tons 8.0 tons 9.0 tons
Hammer Total Weight kg 4130 5130 7170 7720 9890 10370 11450
Ram Weight kg 3000 4000 5000 5500 7500 8000 9000
Drive Cap Weight kg 540
Max. Stroke mm 1000
Min. Stroke mm 100
Max. Energy (Stroke @ 1m) kNm 29 39 49 54 73 78 88
Blow Rate bpm 38+
Working Pressure bar 170 180 200 220 240 250 260

Piling Rig Technical Data


Hitachi EX / ZX200 or EX / ZX220 Hitachi EX / ZX300 or EX / ZX350 series,
Superstructure Type*
series Doosan DX300 series
Superstructure Weight kg 17400 17400 17400 35000 35000 35000 35000
Additional Counterweight kg 2000 3000 3000 3000 3500 4000
Total Weight kg 21530 24530 27570 45720 47890 48870 50450
Leader Mast Length (A) m 18 18 18 19.50 19.50 19.50 21.00
Total Height from Ground (B) m 19.28 19.28 19.28 20.70 20.70 20.70 22.20
Transportation Length (C)** m 15.54 15.54 15.54 15.60 15.60 15.60 15.60
Transportation Height (D)** m 3.88 3.88 3.88 4.08 4.08 4.08 4.08
Transportation Width (E)** m 2.99 2.99 2.99 3.19 3.19 3.19 3.19
* The superstructure mentioned is commonly used to fabricate, other equivalent superstructures can be used.
** Transportation dimensions are for reference only.
Hitachi EX / ZX300 or EX / ZX350 series, Doosan DX300 series

Hitachi EX / ZX200 or EX / ZX220 series


Hiley’s Formula for Driven Pile Set Calculation *

Pile Data
Type of Concrete Pile : R.C. R.C. R.C. Spun
Size of Concrete Pile mm : 250 x 250 300 x 300 350 x 350 Ø500
Pile Weight kg/m : 150 216 294 274
Pile Working Capacity tons : 70 100 140 200
Factor of Safety Allowed : 2 2 2 2
R = Ultimate Pile Capacity tons : 140 200 280 400

Equipment Data
Type of Hammer Used : IPH750 Hydraulic Hammer
Weight of Drive Cap kg : 540
H = Height of Free Fall mm : 400 500 600 700
Assumed Penetration m : 24.0
P = Total Pile Weight tons : 3.600 5.184 7.056 6.576
C = Temporary Elastic Compressions mm : 12.5 (assumed)
W = Weight of Hammer Ram tons : 4.00 5.50 7.50 9.00
e = Hammer Efficiency : 1.00 (for Hydraulic Hammer)
Coefficient of Restitution : 0.5
S = Set Penetration of the Pile per Blow mm

(𝑾𝒆𝒊𝒈𝒉𝒕 𝒐𝒇 𝑯𝒂𝒎𝒎𝒆𝒓 𝑹𝒂𝒎 × 𝒆) + (𝑪𝒐𝒆𝒇𝒇𝒊𝒄𝒊𝒆𝒏𝒕 𝒐𝒇 𝑹𝒆𝒔𝒕𝒊𝒕𝒖𝒕𝒊𝒐𝒏)𝟐 × (𝑻𝒐𝒕𝒂𝒍 𝑷𝒊𝒍𝒆 𝑾𝒆𝒊𝒈𝒉𝒕)


𝒁=
(𝑾𝒆𝒊𝒈𝒉𝒕 𝒐𝒇 𝑯𝒂𝒎𝒎𝒆𝒓 𝑹𝒂𝒎 × 𝒆) + 𝑻𝒐𝒕𝒂𝒍 𝑷𝒊𝒍𝒆 𝑾𝒆𝒊𝒈𝒉𝒕

250 x 250 300 x 300 350 x 350 Ø500


4.00 + (0.52 × 3.600) 5.50 + (0.52 × 5.184) 7.50 + (0.52 × 7.056) 9.00 + (0.52 × 6.576)
𝑍= 𝑍= 𝑍= 𝑍=
4.00 + 3.600 5.50 + 5.184 7.50 + 7.056 9.00 + 6.576

4.90 6.80 9.26 10.64


𝑍= 𝑍= 𝑍= 𝑍=
7.60 10.68 14.56 15.58

𝑍 = 0.64 𝑍 = 0.64 𝑍 = 0.64 𝑍 = 0.68

𝑾𝒆𝒊𝒈𝒉𝒕 𝒐𝒇 𝑯𝒂𝒎𝒎𝒆𝒓 𝑹𝒂𝒎 × 𝑯𝒆𝒊𝒈𝒉𝒕 𝒐𝒇 𝑭𝒓𝒆𝒆 𝑭𝒂𝒍𝒍 × 𝒁


𝑹=
𝑺𝒆𝒕 𝑷𝒆𝒏𝒆𝒕𝒓𝒂𝒕𝒊𝒐𝒏 𝒐𝒇 𝒕𝒉𝒆 𝑷𝒊𝒍𝒆 𝒑𝒆𝒓 𝑩𝒍𝒐𝒘 + (𝑻𝒆𝒎𝒑𝒐𝒓𝒂𝒓𝒚 𝑬𝒍𝒂𝒔𝒕𝒊𝒄 𝑪𝒐𝒎𝒑𝒓𝒆𝒔𝒔𝒊𝒐𝒏𝒔 ÷ 𝟐)
𝑾×𝑯×𝒁
𝑹=
𝑺 + (𝑪 ÷ 𝟐)
250 x 250 300 x 300 350 x 350 Ø500
4.00 × 400 × 0.64 5.50 × 500 × 0.64 7.50 × 600 × 0.64 9.00 × 700 × 0.68
140 = 200 = 280 = 400 =
𝑆 + (12.5 ÷ 2) 𝑆 + (12.5 ÷ 2) 𝑆 + (12.5 ÷ 2) 𝑆 + (12.5 ÷ 2)

𝑆 = 7.31 − 6.25 𝑆 = 8.80 − 6.25 𝑆 = 10.29 − 6.25 𝑆 = 10.71 − 6.25

𝑆 = 1.06 𝑆 = 2.55 𝑆 = 4.04 𝑆 = 4.46

We proposed S = 10.6 mm / 10 We proposed S = 25.5 mm / 10 We proposed S = 40.4 mm / 10 We proposed S = 44.6 mm / 10


blows blows blows blows
* Hiley’s formula is for reference only, it should be ascertained by on-site load test.