Tugas 2 - 01.2017.1.05432 - Bayu Afif Rachman

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

PERHITUNGAN KOLOM BAJA KOMPOSIT

BAYU AFIF RACHMAN


01.2017.1.05432

L Kolom = 5200 mm
Mutu Beton f'c = 30 MPa
Mutu Baja fy = 250 MPa
Mutu Tulangan = 240 MPa
Profil Baja IWF 400.200.8.13
As Baja = 8192 mm2
Dimensi Kolom 60x60cm
b = 600 mm
h = 600 mm
Ag Beton = 360000 mm2
Ec = 23500 MPa
Tulangan Utama = 4D 25
Tulangan Sengkang = ø10-250

A . PERENCANAAN KOLOM KOMPOSIT


Batasan Persyaratan :
1. Luasan Penampang
(As/Ag) x 100% = 2,28 %
2,28 > 1% (memenuhi)

2. Tulangan Sengkang
Diameter 10mm - Jarak sengkang 250mm < 300mm (memenuhi)

3. Rasio Tulangan
Ag = 360000 mm2
Asr (1/4*3,14*D2*4) = 1962,5 mm2
psr (Asr/Ag) = 0,00545
0,0055 > 0,004 (memenuhi)

Kuat tekan Ac (Ag-As-Asr) = 349846


Ec beton 300 Mpa = 23500 MPa
(As + Asr)
C1 = 0,25 + 3 = 0,09167
Ag
0,0917 < 0,7 (memenuhi)
Ic (1/12*500x5003) = 5,2E+09 mm4
C1*Ec*Ic = 1,1E+13
Is = 2,3E+08 mm4
Isr = [1/4xπx252 x(1/2*(500-(2x40)-(2x10)-22)2]
Isr = 3,4E+07 mm4
Es = 200000 MPa
Isr.Ec = 6,9E+12 Nmm2
Is.Ec = 4,6E+13 Nmm2
E Ieff = Es Is + Es Isr + C1 Ec Ic
E Ieff = 6,4E+13 Nmm2
K= 0,5
Lc (K*L) = 2600 mm
π2 E Ieff
Pe = = 9,3E+07 N
Lc2
KUAT TEKAN :

Pno = (Fy*As) + (Fysr*Asr) + (0,85*Fc’*Ac)


Pno = 3118250 N

(Pno/Pe) = 0,03338

Pn = 3074988 N
∅ Pn (0,75*Pn) = 2306241 N

KUAT TARIK :
Pn = (Fy*As) + (Fysr*Asr)
Pn = 2519000 N
∅ Pn(0,9*Pn) = 2267100 N

You might also like