SMC ZSE40F 01 62L Datasheet
SMC ZSE40F 01 62L Datasheet
A
ZSP
Piping specifications
ISA2
Bracket B (ZS-24-B)
01: R 1/8 (With M5 female threads) W1: Rc 1/8 IS
T1: NPT 1/8 (With M5 female threads)
M5 x 0.8
ø4, ø6 F
One-touch fitting
∗ Option
∗ When optional parts only are
required, order with the part
numbers inside ( ).
Input/Output specifications Unit specifications
22 NPN open collector 2 outputs + analog output Nil With unit switching function Note1)
30 ∗ NPN open collector 2 outputs + auto shift input M SI unit only Note 2)
62 ∗ PNP open collector 2 outputs + analog output Note 1) This will no longer be sold for use in
70 ∗ PNP open collector 2 outputs + auto shift input Japan after the new Weight and
∗ Option Measure Act is implemented
(October,1999).
Note Note 2) Fixed unit
When equipped with auto shift function, the following ranges can be set. For vacuum/compound pressure: kPa
Set pressure range Setting range For positive pressure: MPa
–100.0 to 100.0 kPa –100.0 to 100.0 kPa Lead wire length
10.0 to –101.3 kPa –101.3 to 101.3 kPa Nil 0.6 m
–0.1 to 1.000 MPa –1.000 to 1.000 MPa L 3m
16-2-17
Series ZSE40/ISE40
Specifications
Main circuit
(Gray) 1 kΩ (Gray)
Load
1 kΩ
OUT1 OUT1
(Black) 12 to 24 VDC (Black) 12 to 24 VDC
OUT2 OUT2
Load
(White)
Load
(White)
DC (–) DC (–)
(Blue) (Blue)
6.8 kΩ
Load
OUT1
OUT1
(Black) (Black) 12 to 24 VDC
OUT2 12 to 24 VDC
OUT2
Load
(White) (White)
Load
DC (–) DC (–)
(Blue) (Blue)
16-2-18
High Precision,
Digital Pressure Switch Series ZSE40/ISE40
Description
3 1/2-digit LED
Displays present pressure. kPa
Displays each mode.
Displays error mode.
LED (Red)
LED (Green)
Displays OUT2 output condition.
Displays OUT1 output condition OUT1 OUT2
When it is ON, the LED is
When it is ON, the LED is SET illuminated. ZSE
illuminated. ISE
DOWN button
UP button
Switches the mode and set value. PSE
Switching of the mode and set value
Z
SET button I SE3
Switches to each mode and fixes
the set value. PS
Z
I SE 12
ZSP
ISA2
IS
ZSM
Calibration Procedures
PF2
Setting procedure
IF
Manual Key lock
Zero clear Data
pressure setting mode
Enter the set value of the Adjusts the zero point of the Mode is not switched, even if
pressure to perform switch atmospheric pressure. the button is pressed during
output. operation.
Initial setting
Set “Output mode”, “Response
time” and “Auto or Manual
mode”.
Auto Manual
Normal operation
preset pressure setting
Automatically sets the pressure Allows fine-tuning of the Measured pressure is
for the adsorption confirmation data set automatically by displayed and the switch
or supply pressure auto preset. operation begins.
confirmation.
16-2-19
Series ZSE40/ISE40
Calibration Procedures
Initial Setting
1. Initial condition mode 2. Selection of output mode OUT1 3. Selection of output mode OUT2
SET
Press the “SET” button for more Select the “output mode” for Select the “output mode” for
than 2 seconds until “ ” is OUT1 by pressing either 쑿 but- OUT2 by pressing either 쑿
displayed. ton or 쑼 button. button or 쑼 button.
Release it when the display turns “ ” Normally open mode
“ ” Normally open mode
to “ ”.
“ ” Normally closed mode “ ” Normally closed mode
Unit mode: When using a product with
a unit switching function,
refer to the next page for
unit-setting (for overseas).
Press the “SET” button. Press the “SET” button. Press the “SET” button
to complete the setting.
1. Manual set mode 2. Input set point value for OUT1 (1) 3. Input set point value for OUT1 (2)
SET
Select the manual set mode in 쑿 button: Increases set value 쑿 button: Increases set value
the initial condition mode and 쑼 button: Decreases set value 쑼 button: Decreases set value
press the “SET” button until Displays the set values “ ” or Displays the set values “ ” or
“ ” or “ ” is displayed. “ ” alternately. “ ” alternately.
4. Input set point value for OUT2 (1) 5. Input set point value for OUT2 (2) 6. Display of setting auto shift
Press the “SET” button. Press the “SET” button. Press the “SET” button. Press the “SET” button
to complete the setting.
쑿 button: Increases set value 쑿 button: Increases set value ∗ Only for ZSE40(F)/ISE40--30/70(L)-M,
쑼 button: Decreases set value 쑼 button: Decreases set value displays the input mode “ ” and the
Displays the set values “ ” or Displays the set values “ ” or compensation value alternately.
“ ” alternately. “ ” alternately. If auto shift input is not complete, zero
is displayed.
16-2-20
High Precision,
Digital Pressure Switch Series ZSE40/ISE40
[P] 씮
≥ ZSE
H H H (Fixed hysteresis) = 3 digits
ISE
ON
NO OFF
P-1 P-2
Window comparator mode PSE
High pressure (for positive pressure/compound pressure)
High vacuum (for vacuum pressure) Z
Set the unit by either 쑿 button or 쑼 button. 씮 I SE3
: kPa or MPa, : kgf/cm2, OUT1 Output mode
: bar, : psi,
: inHg, : mmHg ∗ OUT2: Same as OUT1.
ON
PS
YES OFF Hysteresis mode
Z
n-2 n-1
High pressure (for positive pressure/compound pressure) I SE 12
High vacuum (for vacuum pressure)
씮
SET Press “SET” button. ≥ ZSP
[N] H H H (Fixed hysteresis) = 3 digits
ON
ISA2
OFF Window comparator mode
OUT1: Selection of the output mode NO n-1 n-2
High pressure (for positive pressure/compound pressure)
High vacuum (for vacuum pressure) IS
씮
ZSM
Auto Preset (For adsorption confirmation) PF2
1. Auto preset mode 2. Preparation for auto preset 3. Auto preset of OUT1
IF
Data
SET
Select the Auto preset mode in Prepare the equipment for use Repeat adsorption and non-
the initial setting mode and under operating conditions. adsorption release several times
press the “SET” button until When setting OUT1 is not in this state.
“ ” is displayed. required, press both the 쑿 The optimal set value is
button and 쑼 button determined automatically.
simultaneously in this state to
skip to “ ”.
High
Suction
Vacuum Workpiece 1 Workpiece 2 Workpiece n
Max. A
SET SET SET
ON
Press the “SET” button. Press the “SET” button. Press the “SET” button
to complete the setting.
OFF
Min. B
Supplies vacuum pressure, Repeat adsorption and non-
Released changing the condition of a adsorption several times in this
Workpiece 1 Workpiece 2 Workpiece n workpiece by adsorption nozzle, state.
Atmosphere
Max. A: Max. pressure value when a workpiece is adsorbed. ON = A –
A–B etc. When setting OUT2 is not The optimum set value is
4
required, press both the 쑿 determined automatically.
Min. B: Min. pressure value when a workpiece is not adsorbed. OFF = B + A – B
4 button and 쑼 button
simultaneously in this state to
skip to the measurement mode.
16-2-21
Series ZSE40/ISE40
Calibration Procedures
Auto Preset (In the case of confirming the supply pressure)
1. Auto preset mode 2. Preparation for auto preset 3. Auto preset of OUT1
SET
Select the Auto preset mode in Prepare the equipment for use The pressure is read and the
the initial setting mode and under operating conditions. optimal set value is determind
press the “SET” button until When setting OUT1 is not automatically.
“ ” is displayed. required, press both the 쑿
button and 쑼 button
simultaneously in this state to
skip to “ ”.
Press the “SET” button. Press the “SET” button. Press the “SET” button
to complete the setting.
Other Functions
Key lock mode Used to avoid a malfunction when buttons on the front part of the switch are pressed.
SET SET
Press the “SET” button for 4 Display “ ” by pressing 쑿 Press the “SET” button for 4 Display “ ” by pressing 쑿
seconds or longer. button or 쑼 button. seconds or longer. button or 쑼 button.
Release it when the display Release it when the display
turns to “ ”. turns to “ ”.
Peak mode Allows holding of the maximum pressure Bottom mode Allows holding of the minimum pressure
value on display under measurement. value on display under measurement.
While displayed, pressing the 쑿 button for 1 While displayed, pressing the 쑼 button for 1
second or longer causes the peak mode to second or longer causes the bottom mode to
display and blink. display and blink.
Pressing the 쑿 button once again for 1 second Pressing the 쑼 button once again for 1 second
or longer reinstates it. or longer reinstates it.
Note) Displaying the peak and the bottom Note) Displaying the peak and the bottom
display is not distinguished. display is not distinguished.
16-2-22
High Precision,
Digital Pressure Switch Series ZSE40/ISE40
Dimensions
ZSE40(F)/ISE40- 01
T1
30 20
M5 x 0.8 thread depth 5
MPa
ZSE
30
20
ISE
OUT1 OUT2
SET
PSE
tsa
12 ss fl
2-M3 x 0.5 thread depth 4
6.4
ro
Z
SE3
18.35
ac
Atmospheric I
dth
release port
Wi
PS
Lead wire length
600 (3000)
ø3.5 Z
I SE 12
ZSP
ISA2
.4
7.8
12
IS
2.5
2.6 ZSM
30
15.2
10.7
PF2
4.5
∗ For splash proof use (IP65), insert an air tube into the atmospheric release port.
IF
14
1.5
ZSE40(F)/ISE40-W1
2-M4 x 0.7 20
30 thread depth 4
Rc 1/8
MPa
7
20
30
OUT1 OUT2
SET
19
5
6.
R
6.4
18.35
Atmospheric
release port
Lead wire length
600 (3000)
ø3.5
.4
7.8
12
7
2.5
2.6
30
15.2
42
10.7
4
6
∗ For splash proof use (IP65), insert an air tube into the atmospheric
release port.
(Refer to “Precautions” on page 16-2-24 for details.)
12 Rc 1/8
16-2-23
Series ZSE40/ISE40
Dimensions
C4
ZSE40(F)/ISE40– C6
M5
32.3
30 5
4. 12.8
20 2-
8
28.15
22.15
MPa 44.3
30
OUT1 OUT2
SET
19
25.4
6.4
18.35
Atmospheric
release port
600 (3000)
Lead wire
length
ø3.5
7.8 For–M5
.4
12
2.5
2.6
30
15.2
43
10.7
8.5
7
12
One-touch fitting ø4, ø6 M5 x 0.8 thread depth 5
∗ For splash proof use (IP65), insert an air tube into the atmospheric release port.
(Refer to “Precautions” for details.)
Precautions
Caution
1. Immediately after supplying power, there is drift of about ±0.5% F.S. When used
with very low pressure, allow the unit to warm up for about 20 to 30 minutes. MPa
2. Do not use in locations where there is splashing or spraying of oils and solvents.
3. When using a commercially available switching regulator, be sure to ground the OUT1 OUT2
FG terminal. SET
4. In locations where the switch is exposed to water and dust, etc., these may
enter the switch from the atmospheric release port. Insert ø4 tubing (inside Atmospheric release port
diameter ø2.5) into the atmospheric release port, and extend the other end to a
safe area where water, etc., is not splashed or sprayed. Be sure that tubing is
not bent and holes are not blocked, etc., or it will become impossible to make Air tube
correct pressure measurements. Recommended tubing (SMC)
TU0425 (Polyurethane)
16-2-24