Professional Documents
Culture Documents
MA5800 V100R018C00SPH109 Patch Installation Guide 01 (From V100R018C00HP1102)
MA5800 V100R018C00SPH109 Patch Installation Guide 01 (From V100R018C00HP1102)
V100R018C00SPH109
Patch Installation Guide
Issue 01
Date 2018-06-12
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective
holders.
Notice
The purchased products, services and feat ures are stipulated by the contract made bet ween Huawei and
the customer. All or part of the products, services and features described in this document may not be
within the purchas e scope or the usage scope. Unless otherwis e specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.
The information in this document is subject to change without notice. E very effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
Website: http://www.huawei.com
Email: support@huawei.com
Change History
Contents
4 Patch rollback............................................................................................................................... 23
4.1 Rolling Back the System ................................................................................................................................................23
5 FAQs .............................................................................................................................................. 25
1 Pre-Installation Instructions
NOTE
Ensure that the patch is installed by qualified engineers.
Read the MA5800 V100R018C00SPH109 Release Notes 01 (for TDC) carefully before installing this
patch.
If any unknown problems occur during patch installation, stop installation and consult technical
support personnel.
The program patch package file of the control board must match the control board type.
Any mismatch may cause faults to the control board hardware.
Ensure that the combined package file is available in case of any necessary system
downgrade.
Table 2-1 File required for the patch installation of H901MPLB control board
SN File Description File Name Remarks
Procedure
Step 1 Choose Administration > NE Software Management > FTP Settings. Then, the FTP
Settings dialog box is displayed.
Step 2 On the System Information tab, select Single NIC Configuration and configure the IP
address of the U2000 server in System IP Address.
Step 3 On the Transfer Protocol tab, select MA5800-X7(V100) in NE type, and SFTP Password
in Protocol. Then, click OK.
----End
Context
Files can be imported in either of the following modes:
Using the OSS server
This mode is used if files required for the upgrade have been uploaded to the OSS server
by using file transfer tools, such as FTP/SFTP, or by copying.
CAUTION
The binary mode must be used when you upload files to the OSS server using file transfer
tools such as FTP/SFTP.
Prerequisite
The FTP/SFTP channel between the PC and OSS server is reachable.
Procedure
Step 1 Choose Administration > NE Software Management > NE Software Library
Management from the main menu.
Step 2 In the NE Software Library Management window, right-click and choose Import.
Step 3 In the Import dialog box, Access NE > MA5800-X7, and choose Patch in File Type, as
shown in the following figure.
Step 4 Click . In the Select File dialog box, select OSS Client.
Step 6 In the Information dialog box, click OK. After obtaining the file information, make sure that
the Patch Version is SPH109. Then, enter MA5800V100R018C00 to Version, click OK,
and click OK in the following figure.
Step 7 When all the required files are imported, the window shown in the following figure is
displayed.
----End
Procedure
Step 1 Choose Administration > NE Software Management > NE Data Backup/Restoration
from the main menu. The device information list is displayed.
Step 2 On the NE Data Backup/Restoration window, check whether the device to be upgraded is in
the device information list. If the device to be upgraded is not in the device information list,
click the button on the toolbar to refresh the list.
Step 5 Navigate back to the Main Topology window, select the device to be queried, right-click, and
then choose NE Explorer. Check status of the control board.
Click the M PLB control board and check the board details. Ensure that the Board Status of control board
is displayed as Normal. The patch can be installed by using the DC only when the control board is
functioning properly.
Step 6 Check status of the service boards in the same way. Ensure that the all the service boards are
functioning properly.
Step 7 Double-click a service board to display the port view. Verify that the ports with services
provisioned are in the activated state.
----End
Procedure
Step 1 Choose Administration > NE Software Management > NE Data Backup/Restoration
from the main menu. The device information list is displayed.
Step 2 In the device information list, select a device, right-click, and choose Backup, as shown in the
following figure.
Step 3 In the displayed dialog box, select OSS Server and click Start.
Step 4 In the device information list, select a device and select Backup Information in the lower
pane. The path for saving the backed up database is displayed, as shown in the following
figure.
NOTE
You can query the path of only one device at a time.
----End
Step 2 On the tab page that is displayed, right-click and choose New Task > Patch Update Task.
The Create Task [Patch Update] dialog box is displayed.
Step 3 In the Create Task [Patch Update] dialog box, use or change the task name assigned
automatically by the U2000 in Task Name (the task name must be unique), select NE Type,
NE Version, and Main Board Type. Select the devices to be upgraded. And then, click Next.
Step 4 In the Operation Configuration [Patch Update] dialog box, select Load Patch, Activate
Patch, and Confirm.
If you select Pause Before Current Operation for Operation (for example, Confirm), the task will
pause before this operation is performed. If you want to continue the task, right-click the task and choose
Continue Task.
Step 5 Select the target version from the Target Version drop-down combo box. In the Confirm
dialog box, click Yes.
Step 6 In the Select Patch File(s) dialog box, select patch file
V100R018C00SPH109_wholepatch_MPLB_TDC, add them to the right panel, and click
OK.
If unnecessary files exist in the window on the right, select them and click . Reserve only
V100R018C00SPH109_wholepatch_MPLB_TDC. Then, click OK.
Step 7 In the Operation Configuration [Patch Update] dialog box, click Next.
Step 8 In the Confirm [Patch Update] dialog box, confirm that the installation procedure is correct
and click OK.
Step 9 A loading task has now been created. To immediately start the loading task, right-click the
task and choose Start Task from the shortcut menu. Then, in the High Risk dialog box,
select I have read the message and fully understood the operation impacts on services,
and click Yes.
----End
Step 2 Verify that the control board patch file is successfully installed.
If the control board patch file is successfully installed, Running is displayed in the Patch
State column.
----End
Command:
display language
Local:
Description: CHINESE SIMPLIFIED (DEFAULT LANGUAGE)
Version: MA5800V100R018C00
Encoding: GBK
General:
Description: ENGLISH (DEFAULT LANGUAGE)
Version: MA5800V100R018C00
Encoding: ANSI
Command:
----End
Step 2 Check the device status to ensure that the device is working properly.
MA5800-X7(config)#display board 0
-------------------------------------------------------------------------
SlotID BoardName Status SubType0 SubType1 Online/Offline
-------------------------------------------------------------------------
0
1 H901XGHD Normal
2 H901XGHD Normal
3
4
5 H901CVEC Normal
6 H901CVEC Normal
7
8 H901MPLB Active_normal
9 H901MPLB Standby_normal
10 H901PILA Normal
11
-------------------------------------------------------------------------
----End
Prerequisite
The FTP/SFTP/TFTP channel between the PC and NMS server is reachable.
Procedure
Save and back up the database file and configuration file for system recovery and
troubleshooting in case the new patch does not work properly.
MA5800-X7(config)#save
Please save configuration file before backup, or the configuration file that
is backed up may not be the latest. Are you sure to continue? (y/n)[n]:y
----End
----End
Command:
display patch all
Software Version:MA5800V100R018C00
SPH109
HP1010
------------------------------------------------------------------------
Current Patch State:
------------------------------------------------------------------------
Patch Name Patch State Delivery Attribute Dependency
------------------------------------------------------------------------
SPH109 running common hot patch NO
HP1010 running common hot patch NO
------------------------------------------------------------------------
Total:2
Last Patch State:
------------------------------------------------------------------------
Patch Name Patch State Delivery Attribute Dependency
------------------------------------------------------------------------
SPH105 running common hot patch NO
HP1010 running common hot patch NO
HP1020 running common hot patch YES
------------------------------------------------------------------------
Total:3
----End
4 Patch rollback
Procedure
Step 1 Obtain the combined package file of the source version, and put the file to the SFTP directory.
Step 2 Obtain the database file that has been backed up before the upgrade, and put it to the SFTP
directory.
You must use the database file of the source version that is backed up before the upgrade.
Otherwise, configuration data may be lost.
Step 3 Load the combined package file, and database of the source version.
1. Run the load packetfile command to load the combined package file of the source
version.
You can run the display progress load command to query the loading progress. In the SFTP loading
mode, the loading progress remains unchanged for a period of time when it reaches 99%. The period
ranges from 20 minutes to 30 minutes, depending on the file size.
2. Run the load data command to load the backup database of the source version.
3. Run the upgrade command to reset the system.
Step 4 Verify the downgrade results. Ensure that the version information after the downgrade is
consistent with that before the upgrade. Pay attention to the patch version.
Example
For example, roll back the software version to the MA5800V100R018C00 version. In this
example:
The SFTP file transfer mode is used.
The IP address of the file transfer server is x.x.x.x.
MA5800-X7(config)#upgrade
{ <cr>|emergency-call-protect<K>|issu<K>|mpls<K> }:
Command:
upgrade
Software upgrades will lead to business interruption, continue? (y/n)[n]:y
----End
5 FAQs