1 General
The maintenance–free air ejector A25A serves for the According to the respective operating conditions, the
automatic ventilation of pumps and suction pipelines. It pressure switch must be set so as to switch the air ejec-
operates according to the ejector principle with a pres- tor off at approx. 80% of the lowest delivery pressure of
sure–dependent control and is adapted for clean, the pump switching it in again at approx. 30%.
chemically neutral water. The water–air mixture is drained through connection
Proper functioning is only assured if suction pipeline, Q3. The connection pipeline may be used for drainage,
fittings and pump are tight. Due to a force–controlled however, it must not be lockable.
shutoff valve in the suction pipeline, the device can also
be used in plants with temporary supply pressure.
5 Materials
2 Safety Lower–flow nozzle: Plastic
Connection of the power supply cables is to be effected Upper–flow nozzle: Plastic
by an electrical expert according to the circuit diagram. Inlet nozzle: G–CuZn l6Si4
In doing so, the current VDE regulations and the regula- Tubes in contact with the liquid: Cu
tions of the local power supply association are to be ob-
served.
Danger by electrical energy must be excluded. 6 Electric connection
Electric connection of the air ejector is to be effected ac-
3 Transportation and Intermediate Stor- cording to the following wiring diagram.
age
The graphical symbols provided on the packing are to
be observed.
During transportation and storage, all connections
must be closed with plugs. For installation, the plugs
are to be removed.
4 Functional Description
Through the venting pipeline, suction branch Q2 of the
air ejector is connected with the venting connection of
the pump. The compressed air required for the venting
process is supplied to the ejector at connection Q1.
To avoid dry running of the pump, the electrical circuit
(not included in the standard scope of supply) must be
designed so that the pump is put into operation only af-
ter the entire system is vented on the suction side
(please refer to Section 8.2 below).
As soon as a delivery pressure has been built up and
the specified pressure limit reached, the air ejector is Control voltage: 230 V, 50 Hz or 60 Hz (80% cyclic
switched off by means of the pressure switch. The duration), enclosure IP 54.
pulse is via the control pipeline connecting the pressure (Special voltages on request),
connection of the pump with connection Q4 at the pres-
sure switch. Power consumption: Start/operation = 22 VA/l5VA.
The delivery pressure dropping to below the specified
pressure limit, the air ejector is switched in again. Operating voltage and frequency must correspond to
the data on the type plate of the air ejector.