PROYEK MINI LPG PLANT LAPANGAN JATA Document No. : DJM-MBA-PCS-CA-004B Rev.

MUSI BANYUASIN, SUMATRA SELATAN


A
DITJEN MIGAS KEMENTERIAN ESDM Tanggal : 30 Jan 2014

LIQUID LIQUID EQUALIZER


CALCULATION
F - 1201

A 30/01/14 Issued for Comment EH AGS


CHK APPR CHK APPR CHK APPR
REV. DATE DESCRIPTION BY
HOKASA PMC ESDM
1. INTRODUCTION
This calculation is intended to calculate Liquid Liquid Equalizer (F-1201)

2. DESIGN METHOD
The calculation according API 12 J, Specification for Oil and Gas Separator.
Calculated sufficient cross sectional area for gas phase to release or separate liquid.
Calculated sufficient liquid retention time for instrumetation spacing.

3. REFERENCES
API 12 J, Specification for Oil and Gas Separator
GPSA, Engineering Data Book, 11th Edition, 1998
Process Design Basis
Process Simulation

4. EQUATION
Mass rate
Volume rate 
Mass density

fluid total mass rate


m 
fluid total vol. rate
5. CALCULATION
BASIS

Vessel Tag Number F-1201


Vessel Description Liquid Liquid Equalizer
Pressure (Operating) 500 psig
Temperature (Operating) 120.00 o
F
Type Vertical, 2 Phase

(Properties based on HYSYS Report Data)


Data Gas Oil Liquid Unit
Volume Flowrate 0.00 - 50.00 MMSCFD, BPD
Mass Flowrate 0.0 - 410.66 lb/hr
Mass Density 0.87 - 35.11 lb/ft3
Molecular Weight 22.52 - -
Viscosity 0.01 - 0.14 cP
Compressibility Factor 0.94 - -
Slug Capacity required 0
CALCULATION

Safety Factor 10 %
Liquid volume rate 12.87 ft3/hr
0.214446
Nozzle

Nozzle Sizing Inlet Vapor Outlet Liquid Outlet


Nominal diameter, in 2 2 2
Actual velocity, ft/s 0.16 0.01 0.16
Actual rho-v2 0.94 0.00 0.94
Max. velocity, ft/s 4.37 60.00 6
Max. rho-v2 670 2500 -
Nozzle sizing criteria OK OK OK

Cartridge Filter Data (Vendor to Confirm)


Outside Diameter of element 2.5 in
Length 20 in
Flowrate per cartridge 5 USGPM
171.4 BPD

Cartridge Filter Required 0.32 ea


Cartridge Filter Selected 1 ea
Volume accumulated required 1.0 min
Accumulated volume required 0.03 BBLS
336.875 in3

Liquid accumulator volume  D 2
 H
4
Lower Section Filter (H) 6 in
Diameter minimum 8.46 in
Selected vessel diameter 10 in OK
Selected length, T/F 40 in