Maintenance

[17815; 15.06.2011]

Summary This manual provides detailed instructions for maintaining the OLEO buffer.

Energy Dissipation Buffers OLEO may also be referred to as SA OLE.

Modification 01 02 03 04 05 06 Prepared 07.08.2012 zhanlexi


KA No. - 160471 159036 159141 159197 592308 Reviewed 10.08.2012 denglian
KA Date 9748 18.08.06 30.04.10 01.09.11 23.12.11 01.09.12 Norms Chkd 10.08.2012 helfensy
Released 01.09.2012 maojuey
OLEO Buffer
Format
Maintenance A4
Classification Lead Office
INVENTIO AG CH-6052 Hergiswil
11350 AP1
K 602848 EN
Copyright © 2012 INVENTIO AG All rights reserved.
INVENTIO AG, Seestrasse 55, CH-6052 Hergiswil, owns and retains all copyrights and other intellectual property rights in this manual. It shall only be used by
SCHINDLER personnel or authorized SCHINDLER agents for purposes which are in the interest of SCHINDLER. Any reproduction, translation, copying or storing
in data processing units in any form or by any means without prior permission of INVENTIO AG is regarded as infringement and will be prosecuted.

Page 1/9
Table of Contents

1 Safety Advice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2 * Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.2 * Preventive Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 4
3 Buffer Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1 Replace Entire Component . . . . . . . . . . . . . . . . . . . . . . . . 8
4.2 Replace Safety Switch . . . . . . . . . . . . . . . . . . . . . . . . . . 8
A1 * Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

OLEO Buffer
K 602848 06
Maintenance
Copyright © 2012 INVENTIO AG 2/9
1 Safety Advice

 Exclusively for competent professionals.


 Current version of the safety manual and any local safety requirements must be
consulted and followed before initiating works.

OLEO Buffer
K 602848 06
Maintenance
Copyright © 2012 INVENTIO AG 3/9
2 * Preventive Maintenance

2.1 Overview

Task List
Interval Description Details
[M = Month] Given In
12 M General check of buffers 1) Section 2.2
12 M Clean buffer 1) Section 2.2
12 M Check oil level 1) Section 2.2
12 M Check height of buffers 1) Section 2.2
12 M Check safety switch 1) Section 2.2
1) These tasks must be completed after a buffer impact.

2.2 * Preventive Maintenance

General Check
No Step
1 Check the buffer and its horizontal support (if available) for any damage.
2 Check that the buffer stands vertically in the hoistway.

Clean
1 Clean the buffer casing.
2 Clean the plunger and oil lightly.

Check the Oil


Level 1 Unscrew the oil filler screw (1).
2 Check the oil level using the dipstick (2). The minimum (B) and maximum (A) oil
levels allowed are marked on the dipstick.
3 If necessary, refill oil according to the procedure stated below. If the buffer is
leaking, it must be replaced.
HP H

A A
2
B B
1 3
HP

a) b)
Points of Maintenance (buffer type LB shown) [17802; 08.06.2011]
1 Oil filler screw a) Buffer standard version
2 Dipstick b) Buffer pre-filled with oil
3 Safety switch

OLEO Buffer
K 602848 06
Maintenance
Copyright © 2012 INVENTIO AG 4/9
Refill Oil
1 Unscrew the oil filler screw (1) and refill with the quantity of oil needed. The
maximum oil level must not be exceeded. For the oil type, refer to the note below.
2 Check the oil level using the dipstick (2).

Use HLP 68/ISO 6743/4 L-HM68, in accordance with DIN 51524. These are mineral oils
with additives for improvement of anti-corrosion properties, anti-aging and improved
performance under boundary lubrication conditions (anti-seize additives).

Check Buffer
1 Check the HP dimension against the following table when the buffer is fully
Height
extended.
2 If the dimension HP is in accordance with the value in the following table, the
buffer is ready for operation. If not, the unit must be replaced.

HPH

HP
Height of Buffer (Drawing with SEB type) [17801; 08.06.2011]

Type HPH [mm] 1) HP [mm] Oil [l]


LSB10.A 73.3 221 (-2, +2) 0.45
LSB16.B 173.7 483 (-2, +3) 0.88
LSB18.B 219.7 575 (-2, +3) 1.03
LSB20.B 279 767 (-5, +4) 2.18
LSB25.B 435 1158 (-4, +4) 3.32
MLB13.1 120 407 (-4, +4) 1.02
MLB16.1 173 529 (-4, +4) 1.41
MLB18.1 219 631 (-4, +4) 1.74
MLB20.1 279 779 (-4, +4) 2.18
MLB25.1 435 1161 (-4, +4) 3.32
MLB32.1 679 1725 (-5, +4) 5.19
MLB35.3 881 2104 (-5, +5) 24.5
MLB40.3 1141 2689 (-5, +5) 31.5
SEB16.2 173 537 (-5, +4) 1.45
SEB18.2 219 640 (-5, +4) 1.77
SEB20.2 279 774 (-5, +4) 2.20
SEB25.2 435 1123 (-5, +4) 3.30
LB16.003 203 613 (-5, +5) 4.62
LB18.001 249 719 (-5, +5) 5.58
LB20.001 300 835 (-5, +5) 6.64
LB23.001 387 1034 (-5, +5) 8.45
LB25.003 462 1207 (-5, +5) 10.00

OLEO Buffer
K 602848 06
Maintenance
Copyright © 2012 INVENTIO AG 5/9
Type HPH [mm] 1) HP [mm] Oil [l]
LB32.002 699 1702 (-5, +5) 20.00
LB35.001 881 2104 (-5, +5) 24.50
LB40.001 1141 2689 (-5, +5) 31.50
LB50.001 1740 4208 (-9, +8) 27.80
LB55.001 2109 5031 (-9, +8) 33.30
LB60.001 2504 6173 (-9, +8) 73.50
1) Minimum value

Check Safety
Switch 1 Check that the safety switch (3) KP operates smoothly and works correctly.

OLEO Buffer
K 602848 06
Maintenance
Copyright © 2012 INVENTIO AG 6/9
3 Buffer Test

 Buffer tests must be carried out periodically according to the local regulations.
 After the buffer tests have been carried out, check the height HP according to the table
above.
 If the top position height is no longer reached, or if leaks are found, the buffer must be
replaced.

OLEO Buffer
K 602848 06
Maintenance
Copyright © 2012 INVENTIO AG 7/9
4 Replacement

4.1 Replace Entire Component

Procedure
No Step
1 Remove old buffer and drain oil from buffer.
2 Install new buffer according to the installation procedure.

Waste Disposal Dispose of the oil according to the environmental standard.

Related
Document Title
Documents
K 602846 Technical Information and Configuration OLEO Buffer
K 602847 Installation OLEO Buffer
EJ 604722 SAIS Supporting Info Buffer
EJ 41348298 SAIS Information Buffer NA

4.2 Replace Safety Switch

Procedure
No Step
1 Remove wiring from terminals and remove old safety switch.
2 Install new safety switch at same position.
3 Connect wires to terminal of new safety switch.
4 Check function of new safety switch.

OLEO Buffer
K 602848 06
Maintenance
Copyright © 2012 INVENTIO AG 8/9
A1 * Spare Parts

Spare Parts
Pos. Image Description Stock Quantity ID. No.
Part 1)
1 - Oil DIN51524 - HLP68 Y - 293150
2 Switch for LSB Series,
MLB13.1 ... MLB32.1, SEB Series:
 IP67
N 1 59373267
 with roller plunger
 Impulse, 1 NC / 1 NO
 with gland
Switch for LSB Series,
MLB13.1 ... MLB32.1, SEB Series:
 IP67
N 1 59373268
 with roller plunger
 Impulse, 1 NC / 1 NO
 with adaptor
Switch for MLB35.3 ... MLB40.3,
LB16.003 ... LB40.001:
 IP67
N 1 59373394
 with angle roller lever
 Impulse, 1 NC / 1 NO
 with gland
Switch for MLB35.3 ... MLB40.3,
LB16.003 ... LB40.001:
 IP67
N 1 59373395
 with angle roller lever
 Impulse, 1 NC / 1 NO
 with adaptor
Switch for LB50.001 ... LB60.001:
 IP67
 with plunger N 1 59373392
 Impulse, 1 NC / 1 NO
 with gland
Switch for LB50.001 ... LB60.001:
 IP67
 with plunger N 1 59373393
 Impulse, 1 NC / 1 NO
 with adaptor
Switch EX for SEB Series:
 Ex-proof
 with roller plunger N 1 207942
 Impulse, 1 NC / 1 NO
 with cable
Switch EX for LB Series:
 Ex-proof
 with roller plunger N 1 217290
 Impulse, 1 NC / 1 NO
 with cable
1) Y = Must be available in given quantity in local stock at all times; O = Optional in local stock