PVSYST 7.0.11 GENERATION REPORT Page 1/5 SOLAR POWER PLANT IN PALANIYAPAPURAM 380Wp - Mono Crystalline modules Grid-Connected System: Simulation parameters Project : Palaniyappapuram Geographical Sit Palaniyappapuram Situation Latitude Time defined as Legal Time Albedo Meteo data: Palaniyappapuram Country India 854° N Longitude 77.86" E Time zone UT#5.5 Altitude 162m 0.20 Meteonorm 7.2 (1981-1990), Sat=43% - Synthetic Simulation variant: New simulation variant Simulation date 19/10/20 1102 Simulation parameters System type Collector Plane Orientation Tilt Sheds configuration Nb, of sheds. Sheds spacing Shading limit angle Limit profile angle Models used Transposition Horizon Free Horizon Near Shadings User's needs Linear shadings Unlimited load (grid) Sheds on ground e Azimuth 66 Identical arrays 6.00 m Collector width 4,04 m 15.7" — Ground Cov. Ratio (GCR) 67.3% Porez Diffuse Perez, Meteonorm Circumsolar separate PV Array Characteristics PV module Si-mono Model AXiblackpromium HC AC-380MH/144S, Original PVsyst database Manufacturer Axitec Energy Number of PV modules In series 20 modules In parallel 132 strings Total number of PV modules nb. modules 2640 Unit Nom. Power 380 Wp. Array global power Nominal (STC) 1003 kWp At operating cond. 1000 kWp (26°C) Array operating characteristics (50°C) Umpp 794V Impp 1259. Total area Module area $238 m? Cellarea 4671 m? Inverter Model _PVS800-57-1000kW-C_1 Custom parameters definition Manufacturer ABB Characteristics Unit Nom. Power 1000 kWac Oper. Voltage 570-850 V Inverter pack Total power 1000 kWac Prom ratio 1.00 Nb. of inverters 1 units Total Total power 1000 kWac Pnom ratio 1.00 PV Array loss factors Thermal Loss factor Uc (const) 20.0 Wim?K Uv (wind) 0.0 Wink J mis Wiring Ohmic Loss Global array res. 9.5 m2 Loss Fraction 1.5% at STC Module Quality Loss Loss Fraction -0.3 % Module mismatch losses Loss Fraction 2.0 % at MPP Strings Mismatch loss. Loss Fraction 0.10 % PVSYST 7.0.11 GENERATION REPORT Page 2/5 SOLAR POWER PLANT IN PALANIYAPAPURAM pai ae 380Wp - Mono Crystalline modules Grid-Connected System: Simulation parameters Incidence effect (IAM): Fresnel smooth glass, n = 1.526 oO 30" 50° eo" 70 7 a0" a 90° Zo00 | 6.908 | 0.981 | a.948 | 0.063 | 0.776 | 0.636 [0.403 | 0,000, PVSYST 7.0.11 GENERATION REPORT Page 3/5 SOLAR POWER PLANT IN PALANIYAPAPURAM. mercueiecanot 380Wp - Mono Crystalline modules Grid-Connected System: Near shading definition Project Palaniyappapuram Simulation variant: New simulation variant Main system parameters ‘System type Sheds on ground Near Shadings Linear shadings PV Field Orientation tilt 8° azimuth 0° PV modules AXiblackpremium HG AC-380MH/144S Prom 380 Wp PV Array Nb. of modules 2640 Pnom total 1003 kWp Inverter Mode! PVS800-57-1000KW-C_1 Prom 1000 kW ac User's needs Unlimited load (grid) Perspective of the PV-field and surrounding shading scene PVSYST 7.0.11 GENERATION REPORT Page 4/5 SOLAR POWER PLANT IN PALANIYAPAPURAM 380Wp - Mono Crystalline modules Grid-Connected System: Main results Palaniyappapuram New simulation variant Main system parameters Near Shadings PV Field Orientation PV modules PV Array Inverter User's needs ‘System type Sheds on ground Linear shadings tilt 8° azimuth AXiblackpremium HC AC-380MH/144S Pho Nb. of modules 2640 Prom total Model PVS800-57-1000KW-C_1 Prom Unlimited load (grid) of 380 Wp 1003 kWp 1000 kW ac Main simulation results ‘System Production Produced Energy Performance Ratio PR Specific prod. 1611 kWhikWplyear [Normalized productions (per Insaled KWp)” Nominal power 1003 MWe Pertormance Ratio PR New simulation variant Balances and main results GlobHor | Diftior | T_Amb | Globinc | Globe | EArray | E.crid | PR vewivm _|_kwevme | 2c | whime | iwnime | wh | wn ratio [aanuary is | 661s | 2699 | 1743 | ss | is | ans | ost February sis | 6457 | 2758 | 1692 | 1642 | 1301 | 1367 | 0805 March is | 7511 | 2853 | 1960 | 1905 | 1604 | i576 | 0802 April v9 | a298 | 2810 | 1747 | 1693 | 1442 | iai6 | 0.808 May iz | 645 | 2836 | 1660 | 1605 | 1379 | 1353 | oai2 June saz | 0530 | 2649 | 1391 | 1338 | aiz4 | asa | 0824 3uly 1s65 | 781 | 2652 | 1506 | 1953 | 1264 | 1238 | 0.219 August unz | 9189 | 2656 | 1684 | 1632 | as | 1388 | 082 September | 1742 | 7095 | 2638 | 1750 | 1699 | 1451 | 1423 | oi October asoa | 7aaz | 2666 | 1603 | 1593 | 1370 | asaa | 086 November 1362 | 6312 | 2628 | 1436 | 1393 | 1204 | i180 | osi9 December x39 | 6343 | 2690 | 601 | 1552 | 1331 | 1306 | 0813 Year sss6e | oiz21 | 2711 | i904 | iso | 16168 | s6i61 | 0.013 Legends: GlobHor Global horizontal kraclation GlobEF Effective Global, corr for IAM and shadings DiffHor Horizontal difuse irracation Earray Effective energy at the output of the array Tam Tamb. E_Grid Energy injected into grid Giobine Global incident in col. plane PR Performance Ratio PVSYST 7.0.11 GENERATION REPORT Page 5/5 SOLAR POWER PLANT IN PALANIYAPAPURAM '380Wp - Mono Crystalline modules Grid-Connected System: Loss diagram Project : Palaniyappapuram jimulation variant : New simulation variant Main system parameters System type Sheds on ground Near Shadings Linear shadings PV Field Orientation tit 8° azimuth 0° PV modules ‘AXibiackpremium HC AC-380MH/144S_Pnom 360 Wp PV Array Nb. of modules 2640 Pom total 1003 KWp Inverter Model PVS800-57-1000KW-C_1" Prom 1000 kW/ac User's needs Unlimited load (grid) Loss diagram over the whole year 1957 kWh? 1.3% 0.31% 2.05% 1919 kWhim®* 5238 meal officioncy at STC = 18.16% 1925 MWh b-0.56% 19.48% 2.10% 1647 wih 1.86% 0.00% 0.00% 0.00% No.o0% 0.00% 1616 Mvh 1616 MWh Global horizontal irradiation, Global incident in col. plane Near Shaaings: radiance loss IAM factor on global Effective frradiation on collectors PV conversion Array nominal energy (at STC offic.) PV loss due t radiance level PV loss due ta temperature Module quality oss Mismatch loss, modules and strings Obmic wiring loss ‘Array virtual energy at MPP Inverter Loss during eperation (efficiency) Inverter Loss over nominal inv. power Inverter Loss due to max. input current Inverter Loss over nominal inv. voltage Inverter Loss due to power threshots Inverter Loss due to vollage threshold ‘Available Energy at Inverter Output Energy Injected Into grid

You might also like