Air Distribution Products

CAP-G
Multi-Nozzle Diffuser
Data Sheet
2 / 20 | Nozzle Diffusers

Table of Contents

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Product Parts . . . . . . . . . . . . . . . . . . . . . . . 4

Setup Possibilities . . . . . . . . . . . . . . . . . . . . . 5

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Ordering Code . . . . . . . . . . . . . . . . . . . . . . . . . 7

Accessory . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Quick Selection . . . . . . . . . . . . . . . . . . . . . . . . 10

Technical Parameters . . . . . . . . . . . . . . . . . . . . . 10

Installation, Maintenance & Operation . . . . . . . . . . . . 16

Transport & Storage . . . . . . . . . . . . . . . . . . . . . . 16

Supplement . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Related Products . . . . . . . . . . . . . . . . . . . . . . . . 17

Good to know
Current information on all products is
available at www.design.systemair.com
Nozzle Diffusers | 3 / 20

Description
CAP-G is a multi-nozzle diffuser with a backing box, mainly intended for air supply in comfort ventilation systems
for offices, shops, medical rooms, school classrooms, etc., installed in plaster board false ceiling.

Highlights
• Versatile adjustability of air discharge patterns
• Excellent air induction and mixing even with small air flow volumes, fit for VAV ventilation
• High air flow capacity with low noise and moderate pressure drop
• Compact design

Fig. 1: Air flow visualisation


4 / 20 | Nozzle Diffusers

Design
The CAP-G body is made from galvanized steel, composed of the backing box with a vertically oriented rubber gasket
sealed circular connection and diffuser plate with polymer nozzles, attached by spring clips.
The nozzles can be rotated by 360° in the plane of the diffuser plate. The proper directional adjustment
of the individual nozzles results in the desired air discharge pattern. For the installation of the diffuser, there are holes
in the backing frame for screws to fix in the false ceiling board

Product Parts

6
5

3 2 1

Fig. 2: Components of CAP-G

Legend

1 Backing box

2 Connection with rubber gasket

3 Spring clips for diffuser plate fixing (inside the backing box)

4 Diffuser plate

5 Nozzles

6 Safety cable (inside the backing box)


Nozzle Diffusers | 5 / 20

Setup Possibilities

1 2 3

4 5 6

Fig. 3: Nozzle adjustments and resulting air flow pattern

Legend

1 Tangential horizontal swirl discharge

2 Radial horizontal omnidirectional discharge

3 Horizontal discharge, single direction

4 Horizontal discharge, 2 directions

5 Horizontal discharge, 3 directions

6 Vertical discharge
6 / 20 | Nozzle Diffusers

Dimensions
A

øD
H1

H2

Fig. 4: Dimensions of the CAP-G

Tab. 1: Dimensions of the CAP-G

A C H1 H2 øD m
Name
(mm) (kg)

CAP-G-125-16* 326 360 119 248 124 2,0

CAP-G-160-25* 326 360 122 261 159 2,1

CAP-G-200-36* 426 460 122 296 199 3,3

CAP-G-250-49* 566 600 122 351 249 5,0

CAP-G-315-81* 566 600 119 398 314 5,0

NOTE: * Number of nozzles


Nozzle Diffusers | 7 / 20

Ordering Code
CAP-G- -

125-16

160-25

200-36

250-49

Nominal site (con. diameter) - Number of nozzles 315-81

(RAL9010) W

(RAL9003) SW

Surface and nozzle colour RALXXXX

Example of the Ordering Code

CAP-G-250-49-W

Diffuser CAP-G in white colour (RAL 9010) with connection diameter 250 mm and 49 nozzles.
8 / 20 | Nozzle Diffusers

Accessory
THOR
Plenum Box

Description
The THOR plenum box is used together with air diffusers for pressure reduction, airflow balancing and sound
attenuation as well as for measuring and adjusting the air flow. The standard air flow measurement accuracy
is preserved also when the straight duct length in front of the inlet is zero (directly behind Tee or Elbow piece
in the duct). The plenum box can be used for air inlet and extract.

Design
THOR plenum boxes are manufactured from hot-dip galvanized sheet steel with inlet connection sleeve fitted
with a rubber seal tested for air-tightness. The inlet is equipped by the ZEUS damper with impulse tubes for measuring
differential pressure for flow volume calculation, using a portable measuring device. It can be adjusted manually using
a cable gearing.
Nozzle Diffusers | 9 / 20

Dimensions E

57

øD1
A

Tab. 2: Dimensions of the THOR

Type
A B C øD1 øD2 E m
DN1 - DN2
C

(mm) (kg)

100-125 250 300 150 99 126 185 2,5

125-160 250 340 160 124 161 210 2,7

160-200 300 430 195 159 202 280 4,0


40

200-250 350 480 250 199 252 305 5,9

øD2 250-315 450 545 300 249 317 330 8,3

Fig. 5: Dimensions of the THOR

Ordering Code

THOR- -
Example of the Ordering Code

100 THOR-125-160
125
Plenum box THOR with 125 mm circular inlet
160 and 160 mm circular outlet (nominal dimensions).
200

Inlet DN1 (mm) 250

125

160

200

250

Outlet DN2 (mm) 315


10 / 20 | Nozzle Diffusers

Quick Selection
Air flow volume q and pressure drop ∆P at different sound power levels LWA

Type 25 dB 30 dB 35 dB

m /h
3
l/s m /h3
l/s m3/h l/s

CAP-G-125-16 81 23 109 30 137 38

CAP-G-160-25 97 27 132 37 178 49

CAP-G-200-36 131 36 180 50 239 66

CAP-G-250-49 161 45 243 68 318 88

CAP-G-315-81 225 63 342 95 483 134

NOTE: The working points were measured with THOR plenum box and open adjustment damper.

Technical Parameters
Legend

ps Pa Pressure drop

m3/h
qV Air flow volume
l/s

LWA dB(A) A-weighted total radiated sound power level

LpA dB(A) A-weighted total sound pressure level expressed for 10 m2 room absorption area

LW dB Non weighted total sound power level

L0,2 m Air throw length with terminal velocity 0,2 m/s

Lx m Air throw length calculated for specific terminal velocity

x m/s Terminal velocity in range of 0,1 m/s ... 1 m/s

20%, 40%, 60%, The plenum box damper positions in pressure drop/noise diagrams are represented as percentage.
80%, 100% 20% is fully closed damper. 100% is fully open damper.

Calculation of Air Throw for Different Terminal Velocities


Lx = L0,2 · 0,2/x
Nozzle Diffusers | 11 / 20

CAP-G-125-16 + THOR-100-125 CAP-G-160-25 + THOR-125-160


Pa 15 20 25 30 35 40 l/s Pa 15 20 25 30 35 40 45 50 55 60 65 l/s
350 20 % 40 % 200 20 % 40 % 60 %
50 dB(A) 50 dB(A)
45 dB(A)
45 dB(A) 180
300
160

250 140
40 dB(A)
40 dB(A)
120 80 %
200 60 %
100
35 dB(A)
150
80 35 dB(A)
30 dB(A) 80 %
100 60
30 dB(A)
25 dB(A) 100 %
40
25 dB(A)
50 100 %
20

40 60 80 100 120 140 160 m³/h 40 60 80 100 120 140 160 180 200 220 240 m³/h

Diagram 1: Pressure drop & A-weighted total sound power level, Diagram 3: Pressure drop & A-weighted total sound power level,
depending on air flow volume, measured with THOR plenum box depending on air flow volume, measured with THOR plenum box

m CAP-G-125-16 + THOR-100-125 m CAP-G-160-25 + THOR-125-160


4 5

4
3
Horizontal 3
2 Horizontal
2
1
1

40 60 80 100 120 140 160 m³/h 40 60 80 100 120 140 160 180 200 220 240 m³/h

Diagram 2: Isothermal air throw lengths for horizontal radial discharge Diagram 4: Isothermal air throw lengths for horizontal radial discharge
with terminal velocity 0,2 m/s, depending on air flow volume with terminal velocity 0,2 m/s, depending on air flow volume
12 / 20 | Nozzle Diffusers

CAP-G-200-36 + THOR-160-200 CAP-G-250-49 + THOR-200-250


Pa 30 40 50 60 70 80 90 100 110 l/s Pa 40 50 60 70 80 90 100 110 120 l/s
180 20 % 40 % 180 20 % 40 %
45 dB(A) 55 dB(A) 60 % 50 dB(A)
50 dB(A)
160 160 45 dB(A)

140 140
40 dB(A) 60 %
40 dB(A)
120 120
80 %

100 100
35 dB(A) 35 dB(A)
80 80
80 %
30 dB(A)
60 30 dB(A) 60
100 %

40 25 dB(A) 40 25 dB(A)
100 %
20 20

100 150 200 250 300 350 400 m³/h 150 200 250 300 350 400 450 m³/h

Diagram 5: Pressure drop & A-weighted total sound power level, Diagram 7: Pressure drop & A-weighted total sound power level,
depending on air flow volume, measured with THOR plenum box depending on air flow volume, measured with THOR plenum box

m CAP-G-200-36 + THOR-160-200 m CAP-G-250-49 + THOR-200-250


4 4

3 Horizontal 3

Horizontal
2 2

1 1

100 150 200 250 300 350 400 m³/h 150 200 250 300 350 400 450 m³/h

Diagram 6: Isothermal air throw lengths for horizontal radial discharge Diagram 8: Isothermal air throw lengths for horizontal radial discharge
with terminal velocity 0,2 m/s, depending on air flow volume with terminal velocity 0,2 m/s, depending on air flow volume
Nozzle Diffusers | 13 / 20

CAP-G-315-81 + THOR-250-315 CAP-G-125-16


Pa 60 80 100 120 140 160 180 l/s Pa 25 30 35 40 45 50 55 60 65 l/s
160 20 % 40 % 18
45 dB(A) 50 dB(A)
140 16 45 dB(A)

120 14
40 dB(A) 60 %
100 12
40 dB(A)

80 35 dB(A)
10
80 %

60 30 dB(A) 8 35 dB(A)

40 25 dB(A) 100 % 6
30 dB(A)
20 4
25 dB(A)
200 250 300 350 400 450 500 550 600 650 700 m³/h 100 120 140 160 180 200 220 240 m³/h

Diagram 9: Pressure drop & A-weighted total sound power level, Diagram 11: Pressure drop & A-weighted total sound power level,
depending on air flow volume, measured with THOR plenum box depending on air flow volume, measured without plenum box

m CAP-G-315-81 + THOR-250-315 m CAP-G-125-16


4 8

3 6

Horizontal
2 4 Horizontal

1 2

200 250 300 350 400 450 500 550 600 650 700 m³/h 100 120 140 160 180 200 220 240 m³/h

Diagram 10: Isothermal air throw lengths for horizontal radial discharge Diagram 12: Isothermal air throw lengths for horizontal radial discharge
with terminal velocity 0,2 m/s, depending on air flow volume with terminal velocity 0,2 m/s, depending on air flow volume
14 / 20 | Nozzle Diffusers

CAP-G-160-25 CAP-G-200-36
Pa 40 45 50 55 60 65 70 75 80 85 90 95 l/s Pa 60 70 80 90 100 110 120 130 l/s
18 18

16 16
45 dB(A)
45 dB(A)
14 14

12 12
40 dB(A)
40 dB(A)
10 10

35 dB(A)
8 8
35 dB(A)

6 6 30 dB(A)
30 dB(A)
4 4
25 dB(A) 25 dB(A)
140 160 180 200 220 240 260 280 300 320 340 m³/h 200 250 300 350 400 450 500 m³/h

Diagram 13: Pressure drop & A-weighted total sound power level, Diagram 15: Pressure drop & A-weighted total sound power level,
depending on air flow volume, measured without plenum box depending on air flow volume, measured without plenum box

CAP-G-160-25 CAP-G-200-36
m m

6 6

4 4
Horizontal Horizontal

2 2

140 160 180 200 220 240 260 280 300 320 340 m³/h 200 250 300 350 400 450 500 m³/h

Diagram 14: Isothermal air throw lengths for horizontal radial discharge Diagram 16: Isothermal air throw lengths for horizontal radial discharge
with terminal velocity 0,2 m/s, depending on air flow volume with terminal velocity 0,2 m/s, depending on air flow volume
Nozzle Diffusers | 15 / 20

CAP-G-250-49 CAP-G-315-81
Pa 80 100 120 140 160 180 l/s Pa 100 120 140 160 180 200 220 240 260 l/s
14 16

14
12 45 dB(A)

45 dB(A) 12
10

10 40 dB(A)
8 40 dB(A)
8

6 35 dB(A)
35 dB(A)
6

4 30 dB(A) 30 dB(A)
4

25 dB(A) 25 dB(A)
2 2
250 300 350 400 450 500 550 600 650 700 m³/h 400 500 600 700 800 900 1000 m³/h

Diagram 17: Pressure drop & A-weighted total sound power level, Diagram 19: Pressure drop & A-weighted total sound power level,
depending on air flow volume, measured without plenum box depending on air flow volume, measured without plenum box

CAP-G-250-49 CAP-G-315-81
m m

6 6

4 4
Horizontal Horizontal

2 2

250 300 350 400 450 500 550 600 650 700 m³/h 400 500 600 700 800 900 1000 m³/h

Diagram 18: Isothermal air throw lengths for horizontal radial discharge Diagram 20: Isothermal air throw lengths for horizontal radial discharge
with terminal velocity 0,2 m/s, depending on air flow volume with terminal velocity 0,2 m/s, depending on air flow volume
16 / 20 | Nozzle Diffusers

Installation, Maintenance & Operation


Information about installation, maintenance and operation is available in the document “DataSheet_CAP-G”
or follow the instructions at Systemair DESIGN.

Operate in dry indoor conditions with an operation temperature range of -20 °C to +50 °C.

Transport & Storage


Dry indoor conditions with a temperature range of -40°C to +50°C.

Supplement
Any deviations from the technical specifications contained herein and the terms should be discussed
with the manufacturer. We reserve the right to make any changes to the product without prior notice,
provided that these changes do not affect the quality of the product and the required parameters.

Current information on all products is available at Systemair DESIGN.


Nozzle Diffusers | 17 / 20

Related Products
CAP-F
Multi-Nozzle Diffuser
Product information is available within the “UserManual_CAP-F” technical documentation
and at Systemair DESIGN.
18 / 20 | Nozzle Diffusers
Nozzle Diffusers | 19 / 20
www.systemair.com
Systemair Production a.s. · June 2019 · DataSheet_CAP-G