The Pentra C200 Clinical Chemistry Analyzer Provides A Continuous Throughput of 90 Colourimetric Tests

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

The Pentra C200 clinical chemistry analyzer provides a continuous throughput of 90 colourimetric

tests/hour with optional high throughput of 270 tests/hour (ISE module). It features the "Pentra"
cassette for reagent management and fully automatic cuvette management with two racks of 96 single-
use cuvettes.

Overview

• Fixed cycles provide continuous throughput of 90 colourimetric tests/hour

• Optional high throughput ISE module (270 tests/hour)

• Reagent management with unique "Pentra" cassette

• Fully automatic cuvette management - 2 racks of 96 single use cuvettes

• Dedicated waste compartment for used cuvettes and contaminated liquid

• Integrated computer and cooling unit (Peltier)

Product Description

• Analysis Method Types:

o Spectrophotometry: Colorimetry and Turbidimetry

o Potentiometry: Direct (Serum or Plasma) and Indirect (Urine)

• 15 parameters per reagent tray

• Optional ISE Module (Na+, K+, Cl-)

• Maximum Throughput: up to 360 test/h (140 tests/h in standard configuration)

• CE Marked

Sample Handling

• Sample Capacity: 15 positions in refrigerated compartment

• Dedicated stat position in Random access

• Positive Sample Identification: Integrated Barcode Reader

• Sampling Needle: Level, and Shock Detection

• Sample Collection Format: 2, 3, 4, 5, 7 and 10 mL (diameter: from 13 to 6mm)

• Sample Specimen: Serum, Plasma, Urine, CSF, Homogeneous Fluids

• Sample Volume: 2 to 45 µL (0.1 µl increment)

• Automatic Sample Dilution: from 1/2 to 1/30,625

• ISE: 20 µL (Indirect) or 93 µL (Direct)

• Automatic Post Concentration: from x2.0 to x 20.


• Automatic Re-run

Calibrator/Control Handling

• Calibrator/Controls Positioning on Sample Tray in the Refrigerated compartment

• Automatic Standard Dilution Series:

o Dilution Factors: Main Direct 1/2 - 1/175

o Dilution Factors: Main Indirect 1/176 - 1/30 6258

Reagent Handling

• 15 parameters on board in a closed refrigerated area (8-15°C)

• Positive Reagent Identification: Integrated Barcode Reader

• Reagent Needle: Level Detection and shock detection

• Reagent management with cassettes: Automated Reagent On-board Stability Check plus continuous
test countdown check by capacitive effect.

• Reagent Volume: from 20 to 350 µL

Reaction System

• Reaction Volume: 120 to 450 µL

• Reaction Temperature: Air bath at 37°C

• Photometer Reaction Cycle:20 seconds

• Homogenization with Stirring Paddle

• Reaction Time: 1 to 29 cycles

• Disposable Acrylic Cuvettes

• Automatic Cuvette Changer

• Cuvette Capacity: 192 cuvettes (2 racks of 96 cuvettes)

• 7 Integrated Calculation Algorithms